Murphy SHD45, SHD30 User Manual

Normally Open and Normally Closed Overspeed Alarm or Shutdown Switch
(Standard)
RPM Data and Power Supplied by Magnetic Pickup or Capacitor Discharge (CD) Ignition
Accurate to ±0.5% of Display Reading
Hours Can Be Preset and Reset to Zero
SHD30 and SHD30-45 Models
Description
The SHD30 and SHD30-45 are microprocessor­based tachometers with hourmeter and an over­speed trip point. The trip point can be connected as either a form “c ” relay output or as a normally open SCR output for alarm or shutdown on over­speed.
The SHD30 features a panel-mounting design, plas­tic enclosure that is 5-1/16 (129 mm) long and 4-1/4 in. (108 mm) high.
The SHD30-45 has the same enclosure, but it also has a backplate with studs to mount like a SHD­45, OPLFC.
The SHD30 models power and RPM data are supplied by either a magnetic pickup or a capacitor discharge (CD) ignition. The hourmeter is adjustable to a preset time and resettable to zero. Should power be lost, on-board batteries maintain the run hours display and allow for resetting the overspeed relay output.
Basic Operation
When a tach signal is present the SHD30 models display rpm. When a tach signal is not present, the display is blank unless the Read Hours membrane key, on the faceplate is pressed and held.
The five-digit, liquid crystal display is updated every second. The run hours, overspeed set point and current pulses per engine revolution can be dis­played by manipulating the membrane switches. Run hours can be displayed even after power is lost. The run hours display can be configured to alternate with the RPM display.
Applications
Easy-to-Calibrate
The SHD30 models calibration is done by enter­ing the number of pulses per engine revolution using the Pulses per Revolution and Overspeed Setpoint membrane keys, on the faceplate. The number of pulses is determined by the number of cylinders, cycles and ignition features. It is also determined by the number of ring gear teeth of the engine’s flywheel on a magnetic pickup sys­tem.
Presetting and resetting running hours is done from the back and front of the SHD30 models.
Specifications
Power input:
CD ignition: 90 to 350 VDC.
150 µA typical @ 90 VDC; 300 µA @ 350 VDC.
Magnetic Pickup: 5 to 120 Vrms.
325 µA typical @ 5 Vrms, 100 Hz; 450 µA typical @ 5 Vrms, 1 kHz; 1 mA typical @ 5 Vrms, 5 kHz; 2 mA typical @ 5 Vrms, 10 kHz; 15 mW max. @ 5 Vrms, 10 kHz;
2.8 W max. @ 120 Vrms, 10 kHz.
Backup Batteries: 2 replaceable, long life
Lithium batteries, Panasonic CR2032 or equivalent, 3 V, 220 mAh power. Shelf life expectancy 10 years.
Operating Temperature:
-4° to 158°F (-20° to 70°C).
Storage Temperature:
-40° to 300°F (-40° to 150°C).
Case Material: Plastic. Ignition Frequency Range: 3 to 666 Hz. Magnetic Pickup Frequency Range: 1 to 10 kHz. Overspeed Output:
Connected to S.C.R. (Silicon Controlled
Rectifier) terminals:
0.5 A, 350 VDC continuous.
Connected to Form “C” Relay terminals:
Relay Contact, 0.5 A, 30 VDC, 125 VAC resistive.
Tachometer Accuracy: ±0.5% of the display reading or ±1 RPM whichever is greater.
Hourmeter Range: 0 to 65535 hrs. Hourmeter Accuracy: ±15 minutes per year. Laboratory Approvals: CSA (Canadian
Standards Association) approved for Class I, Division 2, Groups C & D hazardous areas.
Shipping Weight : 1 lb ( 0.5 kg). Shipping Dimensions: 9-1/4 x 8-1/4 x 5-1/4 in.
(235 x 210 x 133 mm).
Gas Compressors
Oil Field Equipment
Industrial Engines
Generators
When installed per Murphy Drawing 20-08-0258
C US
SHD3-97050B
Revised 07-04
Replaces SHD-95064B
Catalog Section 20
(00-02-0287)
Digital Tachometer and Hourmeter with Adjustable Overspeed Trip Point
Typical Wiring Diagram
SHD-30 Model Dimensions
Front View Side View
SHD-30-45 Model Dimensions
Mounting Hole
How to Order
Specify model number:
SHD30
= Tach/hourmeter w/overspeed
SHD30-45
= Tach/hourmeter w/overspeed to
mount like SHD45 or OPLFC
00-00-9389
= Panasonic CR2032 or equivalent
backup battery (2 required)
WARNING: In hazardous areas the overspeed relay contact
is certified for use ONLY with Murphy non-incendive or intrin­sically safe products. In non-hazardous areas overspeed relay
contact may be used to switch electromechanical Tattletale
®
or Magnetic Switches that do not exceed the relay contact rating: 1 A, 30 VDC; 0.3 A, 110 VDC; 0.5 A, 125 VAC. However, the preferred output to switch electromechanical Tattletale
®
or Magnetic Switches is the N.O. SCR.
Refer to SHD3-97051N for more details.
SHD3-97050B page 2 of 2
A,
Vd
Vd
YP:
A
@
Vd
@
Vd
PU
Va
YP
A
A@
Va
X
AX
@
Va
A
@
Va
A
EL
AY
Vd
Vd
Warranty
A limited warranty on materials and workmanship is given with this FW Murphy product. A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm
CONTROL SYSTEMS & SERVICES DIVISION
P.O. Box 1819; Rosenberg, Texas 77471; USA +1 281 633 4500 fax +1 281 633 4588
e-mail sales@fwmurphy.com
MURPHY DE MEXICO, S.A. DE C.V.
Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje San Luis Potosí, S.L.P.; México 78384 +52 444 8206264 fax +52 444 8206336 Villahermosa Office +52 993 3162117 e-mail ventas@murphymex.com.mx www.murphymex.com.mx
FRANK W. MURPHY, LTD.
Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K. +44 1722 410055 fax +44 1722 410088 e-mail sales@fwmurphy.co.uk www.fwmurphy.co.uk
MURPHY SWITCH OF CALIFORNIA
41343 12th Street West Palmdale, California 93551-1442; USA +1 661 272 4700 fax +1 661 947 7570 e-mail sales@murphyswitch.com www.murphyswitch.com
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.
MACQUARRIE CORPORATION
1620 Hume Highway Campbellfield, Vic 3061; Australia +61 3 9358 5555 fax +61 3 9358 5558
e-mail murphy@macquarrie.com.au
FW Murphy
P.O. Box 470248 Tulsa, Oklahoma 74147 USA +1 918 317 4100
fax +1 918 317 4266 e-mail sales@fwmurphy.com
www.fwmurphy.com
R
E
G
I
S
T
E
R
E
D
USA–ISO 9001:2000 FM 28221
UK–ISO 9001:2000 FM 29422
Printed in U.S.A.
5-1/16 in. (129 mm)
2 in.
(51 mm)
3-1/8 in. (79 mm)
diameter
3/16 in (5 mm)
diameter,
4 places
4-1/4 in.
(108 mm)
2 in.
(51 mm)
2 in.
(51 mm)
1-1/2 in. (38 mm)
1-9/32 in.
(33 mm)
panel
5-13/16 in. (148 mm )
TB2
1 NO
TB1
1 MPU +
5-120Vrms
2 MPU – 3 NEG 90-300vdc 4 POS 90-300vdc
C.
N.O.
TB2
1234
TB1
+
5-120Vrms
Shield
ground
Magnetic Pickup
5 - 120Vrms
2 C 3 NC 4 +Overspeed SCR 5 –Overspeed SCR 6
Reset Hourmeter
7
+
N.C.
567
1234
IGN
+
CD Ignition 90-350VDC
OR
5-13/16 in. (148 mm )
5-1/16 in. (129 mm)
4-1/4 in.
(108 mm)
Ø6-1/2 in.
c 1kHz;
c
c, 10kHz
5Va
c
300Vd
120Va
@
300Vd
SCR = 0.5A,
c; 600uA @
@ 5Vac,10kHz;
c res
@ 5Vac,100Hz; 450uA@
90Vd @
c, 125Vd
: 325uA
c,5kHz; 2mA
@ 5Vac,10kHz; 2.8W MAX
150uA
5Va @
c TYP:
= 0.5A, 30Vd
INSTALLE CONFORMEMENT MURPHY 20-08-0258
MUST BE INSTALLED PER MURPHY DWG. 20-08-0258
1mA
15mw MAX
AY
c-120Vac TYP
5Va
MPU
OUTPUT REL
CD IGN 90-300Vd
1/4 in. (6 mm ) dia. holes
(3 places)
1-5/16 in. (33 mm )
Side View
KEPS Nuts
(3 Supplied)
1/2 in.
(12 mm )
Ø5-13/64 in.
Front View
Rear View
Loading...