Murphy PXT-01041B User Manual

PXT-01041B page 1 of 2
Description
The PXT Series pressure transmitter is a state-of­the-art instruments providing 4 to 20 mA outputs. It features a precision micro-machined silicon diaphragm with fully welded stainless steel pressure port for greater accuracy, stability and a wide range of compatibility.
The enclosure is made of 316 stainless steel and all wetted parts are 316L stainless steel or HASTELLOY C276.
Applications
The PXT can be used in applications such as Compressors, Engines, Process Control, Liquid Level and Pumps.
Specifications
Accuracy (Full Scale, Best Straight Line):
±0.25% including non-linearity, hysteresis and repeatability. Long term stability better than
0.2% FS over twelve (12) months.
Zero Setting: ±0.5% of full scale (0.25% typical). Span Setting: ±0.5% of full scale BSL (RSS). Overpressure/Proof Pressure: 400% for up to
500 psi (3.45 MPa) [34 Bar]. 200% for higher ranges.
Burst Pressure:
Ranges 0-1000 psi = 600% of full scale or 4000 psi whichever is lower. Ranges 2000 psi 13.79 MPa) [137 Bar]= 20,000 psi (27.5 MPa) [275 Bar].
Response Time: Frequency response better than
2 kHz.
Storage Temperature: -65 to 200°F (-54 to
93°C).
Operating Temperature: -40 to 180°F (-40 to
82°C).
Compensated Temperature: -20 to 160°F (-29
to 71°C).
Total Thermal Effects Over Compensated Range: ±2% FS TEB.
Physical:
Enclosure: Weather Resistant. Body: 316 stainless steel. Meets NACE
MR01-75. Wetted Parts: 316L stainless steel or HASTELLOY C276.
Process Connection: 1/4 NPT female. Electrical Cable: Integral; 60 in. (914 mm);
vented. 1/2 in. NPT male conduit connection
Environmental Effect:
Humidity: No effect. Mounting: Position/orientation has
negligible effect.
Reverse polarity protected
Shock: 1000g 1ms Half sine Pulse in each of 3
mutually perpendicular axis will not affect performance.
Vibration: Effect on output response is less than
0.05% FS/g at 30g Peak 10Hz to 2kHz, limited by 0.05 in double amplitude. (MIL STD 810C Proc. 514.2-2 curve L).
PXT Power Requirements: Typically 24 VDC
is required, using the Loop Resistance Graph, 9-30 VDC.
PXT Series Transmitter Output: 4–20 mA,
2-wire.
Insulation: Greater than 10 Mohms @ 500 VDC.
RFI Protection: To the European standards of
BS EN 50082-2:1991 in accordance with IEC 801 parts 1 to 6 for suspectibility to EMC and to BS EN 50081-1992 for emissions.
Voltage Surge/Spike: Protected against a 600 V
spike to IEC 60-2. Reverse polarity protected.
Sealed: Sealed at one atmosphere at sea level for
ranges > 1000 psi (6.89 MPa) [68 Bar].
Vented: Vented for ranges < = 1000 psi
(6.89 MPa) [68 Bar].
UL Certification: Class I, Division 2, Groups A,
B, C and D; Class II, Groups E, F and G. Pressure transmitter, Model PXT. Intrinsically safe when installed per system, Diagram No. 05-08-0754. UL File #E169675
Shipping Weigh: 0.90 lb. (408 g).
Shipping Dimensions: 5 x 5 x 5 inches
(127 x 127 x 127 mm).
Warranty
A limited warranty on materials and workmanship is given with this FW Murphy product. A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm
PXT Series
0.25% Accuracy
4-20 mA Output Signal
Precision Etched Silicon Sensor
Corrosion Resistant Construction
High Stability
R
C
R
PXT
PXT-01041B
Revised 06-06
Catalog Section 05
Pressure Transmitters
PXT-01041B page 2 of 2
How to Order
To order, please use the part number designation below. Part number example:
PXT-100
_____ – _____
Pressure Range†:
Specify For this range
30V30WC -30” H20 to +30” H20 (-76 cm H20 to +76 cm H20) [+/-0.075 Bar]
30V30 -30” Hg to +30 psig (-76 cm Hg to 207 kPa) [2.07 Bar] 30V100 -30” Hg to +100 psig (-76 cm Hg to 689 kPa) [6.89 Bar]
15 0-15 psi (103.4 kPa) [1.03 Bar]
60 0-60 psi (413.7 kPa) [4.13 Bar]
100 0-100 psi (689 kPa) [6.89 Bar]
200 0-200 psi (1.38 kPa) [13.78 Bar]
300 0-300 psi (2.07 kPa) [20.67 Bar]
400 0-400 psi (2.75 MPa) [27.56 Bar] 600 0-600 psi (4.14 kPa) [41.34 Bar]
1000 0-1,000 psi (6.89 MPa) [68.9 Bar] 2000 0-2,000 psi (13.79 MPa) [137.8 Bar] 3000 0-3,000 psi (20.69 MPa) [206.7 Bar] 5000 0-5,000 psi (34.48 MPa) [344.5 Bar] 6000 0-6,000 psi (41.37 MPa) [413.4 Bar]
NOTE: Conversions are approximate.
Model
PXT =
Loop Resistance Graph
Supply voltage for the PXMS must be within range of 9-30 VDC. The Graph below shows the minimum supply voltage (VDC) required for a given load resistance (RL).
Total Load Resistance (RL)*
(OHMS)
Power Supply Voltage (VDC)
*NOTE: Cable resistance effect included in RL.
19V, 500
29V, 1000
Under
Voltage
Area
Operating
Area
Over
Voltage
Area
PXT Series Dimensions
Low Pressure Units
1/4 NPTF
2.08 in.
(53 mm)
7/8 Hex
316 Stainless
Steel Housing
2 in.
(51 mm)
2.30 in. (58 mm)
2.30 in. (58 mm)
.86 in. (22 mm)
.866 A/F
1/2 NPTM
7/8 Hex
316 Stainless
Steel Housing
60 in. (1524 mm) long cable-std.
.86 in. (22 mm)
1.18 in. Dia. (30 mm)
1/4 NPTF
1.18 in. Dia. (30 mm)
.866 A/F
1/2 NPTM
60 in. (1524 mm) long cable-std.
High Pressure Units
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time. MURPHY, the Murphy logo, are registered and/or common law trademarks of Murphy Industries, Inc. This document, including textual matter and illustrations, is copyright protected by Murphy Industries, Inc., with all rights reserved. (c) 2006 Murphy Industries, Inc.
www.fwmurphy.com
918.317.4100 Email: sales@fwmurphy .com
1500
250ohm
2
0
1000
500
2
50
0
10
3
0
4
0 5014V @