Murphy OPLHACS, OPLH User Manual

OPLH-94122B page 1 of 4
OPLH / OPLHACS Series
Combination Level Indicating Gage and Critical Level Limit Switch
High and Low Level Limit Contacts Are Visible and Adjustable
Designed to Start and Stop Pumps to Maintain Specific Levels
Indication only Murphygage®instrument Available
Latching Control Relay Versions Available
Description
The OPLHC/OPLHACS Series Level Swichgage instruments are combination level indicating gages with adjustable low and high limit switches. Limit switches can be wired directly to electric pilot circuits to operate alarms, shutdown or start/stop pumps to maintain predetermined levels.
Surface mount or panel mount enclosure is available for both model series. All models feature a 4-1/2 in. (114 mm) dial for easy viewing. Adjustable limit switches are accessible from front of the Swichgage instrument.
Specialized models are available for specific applications involving engines or electric motors.
OPLHC/OPLHACS Series Swichgage instruments
include 2-adjustable, pilot duty, pointer type contacts. Contacts have self-cleaning motion to enhance electrical continuity. Models are available with a rugged bourdon-tube or 316 stainless steel bellows sensing element for greater accuracy and sensitivity in lower ranges.
A “freeze-proof” sensor of 316 stainless steel with Buna-N rolling diaphragm, is available. The “freeze-proof” sensor (OPLHAFP) inserts approx., 2 in. (52 mm) inside a tank.
OPLHBP/OPLHABPS
Internal latching control relays are available to provide ON/OFF automation for electric motor applications.
OPLHC and OPLHACS series are avail­able in indication only Murphygage models (OPLHAGS). See Page 2 to determine the model for your application.
Applications
Saltwater Disposal Systems
Waterflood Systems
Diesel Day Tanks
Oil Storage Tanks
Basic Operation
The OPLHC/OPLHACS series operate from static head pressure. Pressure is transmitted to the process connection of the Swichgage instrument. From here the pressure flexes the bourdon tube or operates the 316 stainless steel bel­lows (depending on which model you have). The bourdon tube/bellows oper­ates the stainless steel rotary geared movement which in turn operates the indicating pointer on the face of the dial. When the pointer (A) closes with the limit contact (B), a control circuit (C) is completed and signals an alarm and/or shutdown or starts/stops a pump.
Warranty
A limited warranty on materials and workmanship is given with this FW Murphy product. A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm
R
Selected configurations are third party listed. Consult FWMurphy for details.
OPLHFC
OPLHACS
A
Adjustment
Knob
B
C
OPLH-94122B
Revised 03-06
Catalog Section 15
4-1/2 in. (114 mm) Dial Level Swichgage
®
instrument
OPLH-94122B page 2 of 4
Specifications
Shipping Dimensions
Item Dimensions: 16 x 11 x 5-1/2 in. (406 x 279 x 140 mm).
Explosion-proof models:
12 x 12 x 9 in. (305 x 305 x 229 mm).
Shipping Weights
Item Weight: 8 lb. (3.6 kg) approximately.
Explosion-proof models: 22 lb. (10 kg) approximately.
OPLHFC
OPLHCE
OPLHC
Enclosure Type (die cast aluminum)
• Surface mount, square case
• Panel mount, round case
• Panel mount, square case
Limit Switch Ratings
• Pointer Contacts:
SPDT center off; 2 A, 30 VDC, 1 A, 125 VAC.
Latching Control Relay
• SPDT,10 A @ 120 VAC (standard)
• DPDT, 12 VDC (Optional)
• DPDT, 24 VAC (Optional)
• DPDT, 24 VDC (Optional)
Sensing Element
• Bourdon Tube, Bronze/Brass (standard)
• Bellows, 316 Stainless Steel (standard)
Process Connections
• 1/4 NPT Male
• 1/4 NPT Female
• 2 NPT Male
Geared Movement: 300 series stainless steel. Accuracy (standard calibration is for water)
±2% first/last quarters of scale, 1% middle half scale.
(1)
• 3% full scale.
OPTIONS AVAILABLE (specify when ordering)
• Environment sealed for isolation from the elements (ES).
(2)
• Explosion-proof case; Class I, Div. 2, Groups C & D (EX)
• Explosion-proof less case; internal gage mechanism without case (EL)
• Less case; internal gage mechanism without case (LC)
• Tickler contact (TA)
RANGES AVAILABLE (specify when ordering)
• 0–5 ft. (0–1.5 m) dual scale dial
• 0–10 ft. (0–3 m) dual scale dial
• 0–20 ft. (0–6 m) dual scale dial
• 0–30 ft. (0–9 m) dual scale dial
• 0–60 ft. (0–18 m) dual scale dial
• 0–120 ft. single scale dial
• 0–3.6 metres single scale dial
• 0–4 metres single scale dial
• 0–6 metres single scale dial
• 0–9 metres single scale dial
(1)
Bourdon tube (OPLHC) models in the 20 ft. (6 m) range have an accuracy of 3% full scale.
(2)
ES option available for the 20 ft. (6 m) range models and above.
NOTES:
Options may not be available in combination. Consult factory.
Over range is not to exceed 10% FS above full range.
Calibration is for water. Specify for other liquids.
Add TOTAL height of liquid above the pressure connection to determine correct range (dial scale).
For elevated tanks substract the tank elevation from gage reading to determine actual tank level.
OPLHACS
OPLH / OPLHA Series
OPLHBP
OPLHACES
OPLHABPS
OPLHBPE
OPLHABPES
OPLHFG
OPLHG
OPLHAGS
OPLHAGES
OPLHAFCS
OPLHAFGS
OPLH-94122B page 3 of 4
8 in.
(203 mm)
6-25/64 in.
(162 mm)
8 in.
(203 mm)
Rear mounting holes for surface mounting 3/8-16 UNC-2B 7/8 in. (22 mm) deep, 4 places.
Removable lid to access adjustable contact knobs.
6-3/4 in.
(171 mm)
6-3/4 in.
(171 mm)
Mounting Hole 7-35/64 in. (192 mm) diameter. Not required
for surface mounting.
1/2 NPT optional rear or side conduit
3/8-16 UNC-2B 7/8 in. (22 mm) deep, 4 places.
Process Connection 1/4 NPT Female
Explosion-proof Enclosure (“EX” Option)
8-7/16 in. (214 mm)
3-3/8 in. (86 mm)
7-7/8 in.
(200 mm)
3-15/16 in.
(100 mm)
4-1/32 in. (102 mm)
Mounting Holes 9/32 in. (7 mm) diameter 3 places. Not available on panel mount square case.
1/2 NPT conduit
Process Connection 1/4 NPT male on bourdon tube models and 1/4 NPT female on bellows models.
Surface
NOTE:
Panel mount square case models do not include mounting flange and include bolt circle shown in Panel Mount Enclosure versions (see below).
Dimensions
Surface / Panel Mount Enclosure (Square Case)
Panel Mount Enclosure
(Round Case)
Typical Applications
Above Ground Tank
Below Ground Tank
SWICHGAGE
®
Flow regulator (recommended)
Pressure regulator
Head Pressure
Air compressor
Tank
Tank
SWICHGAGE
®
Direct Mount
Remote SWICHGAGE
®
with Sensing Line Underground
Direct and Remote Tank
Flow regulator (recommended)
Pressure regulator
SWICHGAGE
®
1 foot
Ground surface
Air compressor
Underground tank (vented)
5-7/16 in. (138 mm)
1/4 in. (6 mm) dia. holes (3 places.) on 5-13/64 in. (132 mm) b.c. (bolt circle),120 apart, clocking as shown
Mounting Hole 4-3/4 in. (121 mm) diameter.
120
120
Process Connection 1/4 NPT Male.
120
Panel
2-57/64 in.
(73 mm)
OPLH-94122B page 4 of 4
How to Order
Base Part Numbers
Latching Control Relay Voltage (applies to “BP” models only)
Blank = 120 VAC 2 = 12 VDC 4 = 24 VDC
Bourdon Tube/Bellows
OPLHC Standard=Bronze/Brass OPLHACS Standard=316 Stainless Steel
Range/Scale (specify in feet)*
Bellows Tube
05 = 0-5 ft. X 10 = 0-10 ft. X 20 = 0-20 ft. X X 30 = 0-30 ft. X X 60 = 0-60 ft. X 120 = 0-120 ft. X
*Standard calibration is for water–specify
for other.
Options (see Specifications on page 2
for availability)
ES = Environmentally sealed EX = Explosion-proof EL = (EXLC) Explosion-proof less case LC = Less case TA = (TCA) Tickler contact
Internal Wiring
Contact Ratings: SPDT center off;
2 A, 30 VDC, 1 A, 125 VAC pilot duty.
Contact Ratings: SPDT dry relay contacts,
10 A, 125 VAC.
OPLHC, OPLHACS,
and OPLHAFP
Series
OPLHCE, OPLHFC,
OPLHACES and OPLHAFCS
Series
OPLHBP, and
OPLHABPS Series
Specify model number. NOTE: No designator is required for Standard configurations.
Also, list options in alphabetical order (A to Z). Place a dash (–) between each option. See example below.
OPLHBP – – 2 – 30 – TA
OPLHG OPLHGE OPLHC OPLHBP OPLHAGS OPLHACS OPLHABPS OPLHAFCS OPLHAFGS OPLHFG
OPLHFC OPLHCE OPLHABPGS OPLHBPE OPLHAGES OPLHACES
45LHE 45LHEF 45LHEBP
Tamperproof Contact Accessory
Knob Lock
Limit Switch Knobs
Order 05000610
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time. MURPHY, the Murphy logo, Swichgage®and Murphygage®are registered and/or common law trademarks of Murphy Industries, Inc. This document, including textual matter and illustra­tions, is copyright protected by Murphy Industries, Inc., with all rights reserved. (c) 2006 Murphy Industries, Inc.
www.fwmurphy.com
918.317.4100 Email: sales@fwmurphy.com
Red White
Black
Red White Black
BLUE
LINE
4
1
120 VAC
= 18 GA.
= 16 GA.
2
WHITE
BLACK
7
9
A
LOW
(RESET)
COMMON
NEUTRAL
RED
YELLOW
3
BROWN
6
5
ORANGE
HIGH (SET)
RESET
SET
1
4
3
6
8
B