Murphy LM300 User Manual

LM-92164N
Revised 10-03
Section 15
(00-02-0176)
Installation Instructions for Level Maintainers
Model Series LM300
LM300: Level Maintainer only (no switches). LM301: Low switch contacts for low level shutdown or
DPST, wired N.O. in normal operating ranges. LM303: Two switches for low and high level shutdown or alarm. Four wires,
DPST, wired N.C. in normal operating ranges. LM304: Two switches. Alarm before shutdown on low level and shutdown on
low-low level. Four wires, DPST, wired N.O. in normal operating ranges. LM305: Two switches. Alarm before shutdown on low level and shutdown on low-
low level. Four wires, DPST, wired N.C. in normal operating ranges.
Specifications
Case/Cover: Die cast aluminum. Switch Housing: Aluminum. Approval Rating: LM301 thru LM305 : CSA certified††for non hazardous
locations. Enclosure Type 4 certified. LM301-EX thru LM305-EX: CSA certified††for Class I, Groups C and D; Class II, Groups F and G hazardous locations. Enclosure Type 4 certified.
Float: Rigid polyurethane foam. Polyurethane coated. Maximum Ambient Temperature: 250°F (121°C) Oil Inlet Connection: Top entry 1/2-14 NPT with built-in filter screen (removable
for cleaning).
Inlet Orifices: 1/4 in. (6 mm) standard. 1/8 in. (3 mm) available. Wire (switch models): 18 AWG x 13 in. (1.0 mm2x 330 mm). Maximum Inlet Pressure (MIP):
Max. Differential: 2 in. (51 mm) between running and stationary oil level.
30 psi (207 kPa) [2.07 bar].
with 1/8 in. (3 mm) orifice.
15 ft. oil (4.6 m oil)
with 1/4 in. (6 mm) orifice.
Maximum Case Pressure (MCP): 15 psi (103 kPa) [1.03 bar]. Orifice Seal†: Buna-N Thumb-Valve™ Switch Contact: Silver, SPDT snap acting, 10A @ 125, 250VAC; 10A @ 30VDC.
(1 only for low level; 2 only for high & low; or 2 only for low with alarm before shutdown)
Outlet Connection: 3/4-14 NPT left side, right side, and bottom. Crankcase Balance Vent Fitting: 1/2-14 NPT. Mounting: Accepts Murphy pipe mounting or universal mounting brackets. Lens: Clear “Frog Eye” non-staining, high impact, high temperature nylon; UV
and heat stabilized.
Dial: High visibility white background with green and white “index” lines for
normal level indication.
Test Knob: Rotate to test switch operation. Turn clockwise for low level test
and turn counterclockwise for high level test.
Flow Rate Test: Using SAE 30 @ 32°F (0°C).
Optional Hose Kit:
15000355
Quantity Description
1 1/2 in. (13 mm) I.D. x
3 ft. (914 mm) long hose
1 1 in. (25 mm) I.D. x
3 ft. (914 mm) long hose 2 1/2 in. (13 mm) worm gear clamp 2 1 in. (25 mm) worm gear clamp 2 1/2 NPT x 1/2 in. (13 mm) barbed fitting 2 3/4 NPT x 1 in. (25 mm) barbed fitting
††
CSA certified with switch contacts rated at 10 A @ 250 VAC (standard).
** Products covered by this bulletin comply with EMC Council directive
89/336/EEC regarding electromagnetic compatibility except as noted.
GENERAL INFORMATION
Read the following instructions before installing. A visual inspection of this product for damage during shipping is recommended before mounting. These installation instructions are intended for all LM300 series models.
Patent 5493086
LM301-EX
Shown with optional hose kit fittings
BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT
Disconnect all electrical power to the machine.Make sure the machine cannot operate during installation.Follow all safety warnings of the machine manufacturer.Read and follow all installation instructions.
**
Orifice
Diameter
1/4 in.
*
(6 mm)
1/8 in.
(3 mm)
Pressure
4 ft. oil – 15 ft. oil
(1.2 m oil – 4.6 m oil)
10 psig – 30 psig
(68.9 kPa – 207 kPa)
[.69 – 2.07 bar]
Flow Rates
4.7 GPH - 31.0 GPH
(17.8 LPH - 117.3 LPH)
16.9 GPH - 32.1 GPH
(63.7 LPH - 121.5 LPH)
*
Standard NOTE: Friction losses due to piping NOT considered.
LM-92164N page 1 of 4
WARNING
LM-92164N page 2 of 4
DIMENSIONS
TYPICAL INSTALLATION
LM300 Series Enclosures
Mounting Brackets with Hardware
)
.
(
)
(
.
.
(
)
15000371 pipe bracket
15000370 universal bracket
The dimensions below are for the optional -EX model enclosure. The standard model enclosure dimensions are the same except the height and width which are: 7 in. (178 mm) H, 7-7/8 in. (200 mm) W.
Mounting (all LM300 Series models)
NOTE: Mount the LM300 series level maintainers as close as possible to the crankcase. Also, excessive vibration can cause overfill. Be sure mounting brackets are supported.
The following instructions are based on the usage of the pipe and universal mounting brackets shown above.
Pipe Bracket Mounting
1. Mount a nominal 1/2 inch (21 mm) diameter pipe to the deck of the engine.
2. Install the pipe bracket to the LM300 using two 3/8-16 UNC x 1 inch
bolts supplied. See Figure 1A.
3. Slip the LM300 onto the pipe and install the two adjustment bolts. Each
adjustment bolt consists of a 3/8-16 UNC x 1 inch bolt and two nuts. See Figure 1B. DO NOT tighten the adjustment screws too tightly because you will have to adjust the LM300 later in the installation process.
Mounting with Universal Bracket
The universal bracket has two mounting methods: deck mounting and pan mounting.
Deck Mounting
1. Install the universal bracket to the deck as shown in Figure 2A with two
flat washers and two 3/8 inch (10 mm) diameter bolts (not supplied).
2. Mount the LM300 to the universal bracket using two 3/8-16 UNC x 1 inch (25 mm) bolts supplied (Figure 2B). DO NOT tighten the adjustment screws too tightly. You will have to adjust the LM300 later in the installation process.
Pipe
Crankcase
Adjustment Bolts
Figure 1B
LM300
Pipe Bracket
Figure 1A
Adjustment Bolts
Figure 2B
Crankcase
Deck
Universal Bracket
Threaded hole
Figure 2A
Additional Hardware Supplied
(4) 3/8-16 UNC x 1 inch
(25 mm) screws
(4) 3/8-16 nut
(4) 3/8 I.D. lock washer
(2) 3/8 I.D. flat washer
Additional Hardware Supplied
(2) 3/8-16 UNC x 1 inch
(25 mm) screws
(4) 3/8 I.D. flat washer
(2) 3/8 I.D. lock washer
(2) 3/8-16 nut
Oil Inlet Connection*
Crankcase
1/2-14 NPT
Test
Knob
8-1/4 in.
(210 mm)
*
Applies to level maintaining models only.
Snap Switch Case Assembly
5-15/16 in.
(151 mm)
2-3/4 in. (70 mm)
with removable
Vent
7-3/16 in. (183 mm)
1/2-14 NPT
screen
Monitoring Port Connection
3 places, 3/4-14 NPT
5-3/16 in. (132 mm)
(152 mm)
3/8-16 UNC-2B Mounting Holes, 2 places
6 in.
Electrical
Conduit
1/2-14
NPT
4.50 in.
(114 mm
.376 in
10 mm minimum bottom surface 2 places
1/4-20 NC
2 places
Slot, .390 in. (10 mm) x 2 in. (51 mm) 4 places
Slot, .390 in. (10 mm) x 4.71 in. (120 mm) 3 places
4.50 in.
(114 mm)
5.19 in.
(132 mm)
5.20 in.
(132 mm)
Hole .88 in.
22 mm) dia
6.69 in.
(170 mm)
7.50 in. (191 mm)
2.50 in 64 mm
1.75 in.
(44 mm)
LM-92164N page 3 of 4
TYPICAL INSTALLATION continued
Crankcase (Oil Pan) Mounting
1. Install the universal bracket to the crankcase using the existing
crankcase bolts (Figure 3A). Crankcase bolt diameter must be no larger than 7/16 inch (11 mm).
NOTE: Check clearance between crankcase and mounting bracket before installing the mounting bracket. If space between the crankcase and mounting bracket does not allow installation and access to the adjustment bolts advance to Step 3.
2. Mount the LM300 to the universal bracket using two 3/8-16 UNC x 1
inch bolts supplied. DO NOT tighten the adjustment bolts too tight. You will have to adjust the LM300 later in the installation process.
3. If space between the crankcase and mounting bracket is narrow, install
the universal mounting bracket to the LM300 before installing to the crankcase oil pan.
Connecting Fittings and Hoses
The following instructions are for all LM300 series level maintainers. All steps that reference oil inlet or oil supply tank DO NOT apply to non-level-maintaining models. Also, these instructions are based on the Murphy optional hose kit described on page 1. If you did not order the optional hose kit, gather the hoses, clamps and fittings as specified in the optional hose kit.
1. Install the LM300 fittings in their proper locations. NOTE: Apply a
sealant such as teflon, to all threaded connections.
2. Attach the 1 inch (25 mm) diameter, flexible monitoring hose to the
crankcase and the monitoring port on the LM300. See Figure 4. CAUTION: The hose must slope slightly downward from the LM300 and MUST NOT have any droop or low spots.
NOTE: If the drain plug on the crankcase is used for the connection, we recommend installation of a tee to allow draining of the crankcase for service.
3. Install the 1/2 inch (13 mm)
I.D. x 3 ft. (914 mm) hose to the vent connection on the LM300 to the vent connection on the crankcase. See Figure 4.
The vent connection on the crankcase must be well above the regulated oil level. All hoses must
be clear of obstructions.
BEFORE CONTINUING, VERIFY THAT ALL HOSE CLAMPS ARE TIGHT.
4. Fill the crankcase to the proper oil levels. With the engine running and
warm, loosen the mounting bracket adjustment bolts and adjust the LM300 so that the oil level in the sight gauge is aligned with the white “index line” on the dial (Figure 4). Tighten the adjustment bolts securely.
Connecting the LM300 to an Oil Supply Tank (level maintaining models only)
1. Remove the caplug from the oil inlet connection. Be sure the filter, inside
the connection, is clear of debris. Install the oil inlet connection.
2. Connect a 1/2 inch I.D. (13 mm) or larger hose
to oil inlet fitting on the LM300 and to the shutoff valve on the oil supply tank. See Figure 5. For models LM300 thru LM305 recommended minimum mounting of the oil supply tank above the LM is 4 ft. (1.2m); maximum 15 ft. (4.6m). The hose must maintain a downward slope and not have low spots or droops. Maximum head pressure rating using standard 1/4 in. (6 mm) orifice is 15 ft. (4.6 meters). See Flow Rate test on page 1 for additional orifice pressure ratings.
3. Before filling the supply tank with
oil, be sure the tank is clean and dry andthe shutoff valve is closed. Also, be sure all hoses and clamps are tight. Fill the tank with CLEAN oil.
4. After oil supply tank is full, open the shutoff valve.
Next, make the proper electrical connections for the application. See contact ratings on page 1 and schematics on page 4.
Switch Test
(switch models only)
To test the shutdown and/or alarm functions perform the following:
1. Unscrew protective boot from test knob. IMPORTANT: Always replace boot after
testing.
2. Turn the test knob 1/4 turn to the right (clockwise), for low test indication (Figure 6).
3. Turn the knob 1/4 turn to the left (counterclockwise), for high test indication. DO NOT FORCE
THE TEST KNOB TO TURN.
NOTE: After the engine shuts down, you will notice that the oil in the
sight gauge glass will rise above normal running level, possibly showing an overfill condition. This is a result of “drain-back” to the engine crankcase and it is normal. Therefore, on models LM302 and LM303 it may be necessary to wire the high level shutdowns into a class “B” or “C” (bypass until first time safe) lockout, so as to allow a permissive start. After the engine is re-started the level will pull down to the normal running level and the shutdown features will be active. A modulating valve (Thumb-Valve) in the level maintaining models will allow oil usage to be made-up continuously during operation.
Adjustment Bolt
Figure 3B
Crankcase
Universal Bracket
Crankcase Bolt
Note Clearance before mounting
Figure 3A
Viewing Lens
Monitoring Hose
Crankcase
Oil Level
Running Engine
Vent Hose
Oil Inlet Hose
Figure 4
Oil Inlet Hose
Oil Supply Tank
Figure 5
Figure 6
WARNING: Overfill condition can be caused by excessive
inlet pressure, (maximum inlet pressure depends on orifice), and/or improper “vent to crankcase” installation. See Flow Rate Test on page 1 for maximum pressure.
LM-92164N page 4 of 4
OPERATING RANGES OF SWITCHES
SWITCH WIRING DIAGRAMS
LM301
SPDT
LM302
High/Low N.O.
DPST
LM303
High/Low N.C.
DPST
LM304
Alarm before
shutdown N.O.
DPST
LM305
Alarm before
shutdown N.C.
DPST
Figure 7: LM301
Figure 9: LM304/LM305
Figure 8: LM302/LM303
This section applies only to models that have built-in switches. The illustrations below and to the right show the dials and their operating ranges of the switches. If levels are within the designated zones the switch(es) will activate. Notice that a switch is capable of activating approximately 3/8 in. (10 mm) from the top of the high zone and 3/8 in. (10 mm) from the bottom of the low zone. The dial in Figure 9 shows that if level continues to drop into the low-low zone, a shutdown will occur.
NOTE: Color zones on dial face show approximate normal operating zones. Actual conditions may vary depending upon operating characteristics of the engine. Placement of the LM300 according to the above instructions will compensate for these conditions.
WARNING: DISCONNECT ALL ELECTRICAL POWER BEFORE CONNECTING ANY WIRES.
CONTROL SYSTEMS & SERVICES DIVISION
P.O. Box 1819; Rosenberg, Texas 77471; USA +1 281 633 4500 fax +1 281 633 4588
e-mail sales@fwmurphy.com
MURPHY DE MEXICO, S.A. DE C.V.
Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje San Luis Potosí, S.L.P.; México 78384 +52 444 8206264 fax +52 444 8206336 Villahermosa Office +52 993 3162117 e-mail ventas@murphymex.com.mx www.murphymex.com.mx
FRANK W. MURPHY, LTD.
Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K. +44 1722 410055 fax +44 1722 410088 e-mail sales@fwmurphy.co.uk www.fwmurphy.co.uk
MURPHY SWITCH OF CALIFORNIA
41343 12th Street West Palmdale, California 93551-1442; USA +1 661 272 4700 fax +1 661 947 7570 e-mail sales@murphyswitch.com www.murphyswitch.com
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.
MACQUARRIE CORPORATION
1620 Hume Highway Campbellfield, Vic 3061; Australia +61 3 9358 5555 fax +61 3 9358 5558
e-mail murphy@macquarrie.com.au
FW Murphy
P.O. Box 470248 Tulsa, Oklahoma 74147 USA +1 918 317 4100
fax +1 918 317 4266 e-mail sales@fwmurphy.com
www.fwmurphy.com
R
E
G
I
S
T
E
R
E
D
USA–ISO 9001:2000 FM 28221 UK–ISO 9001:2000 FM 29422
Printed in U.S.A.
Warranty
A limited warranty on materials and workmanship is given with this FW Murphy product.
A copy of the warranty may be viewed or printed by going to www
.fwmurphy.com/support/warranty.htm
Yellow
Normal
Low
Float
Green
Black
Red
Yellow
Green
Black
High
Normal
Low
High
Normal
Red
Low
Float
Blue
High
Normal
Low
High
Normal
Low
Float
Green
Brown
Orange
3/4 in.
(19 mm)
3/4 in.
(19 mm)
Yellow
Float
3/8 in.
(10 mm)
3/8 in.
(10 mm)
Normal
Low
Low-Low
Normal
Low
Low-Low
Green
Black
Red
Blue
Normal Operating Range
Low Zone Shutdown or Alarm
Float
High Zone Shutdown or Alarm
Normal Low
Low-Low
Normal
Low
Low-Low
Green
Brown
Orange
(19 mm)
3/4 in.
Normal Operating Range
Low Zone Alarm Low-Low Zone Shutdown
3/8 in.
(10 mm)
Normal Operating Range
Low Zone Shutdown or Alarm
3/4 in.
(19 mm)
3/8 in.
(10 mm)
1/4 in.
(6 mm)