Murphy L-5937B User Manual

L-5937B page 1 of 2
For Small Engines and Pumps
See Oil Level and Condition Without Shutting Down
Shutdown or Alarm on Low Lube Level
Adjustable Limit Switch for Alarm and/or Shutdown
Simple Installation
Description
These float actuated Oil Level Swichgage instru­ments are a combination oil level sight gage and adjustable, low and/or high limit switch. The limit switches are normally open during opera­tion–yet close if the level drops or rises to where the float contacts the limit screw. The contact completes a circuit to ground a magneto or trip a Murphy magnetic switch. The magnetic switch can be used to activate alarms and/or shutdown. Models are also available without limit switches.
Application
The level instruments described above can be used on a variety of crankcases, pump gearcases, or oil reservoirs–primarily on small engines and pumps. The following list displays the model and its typical application:
L100
: Small engines and pumps with
non-vented crankcase.
L100W
: Small engines and pumps with
vented crankcase.
L120†: Machined surface on crankcase such as
Witte, National-Oilwell/Garland.
L127: Machined surface on crankcase, specifi-
cally, Fairbanks-Morse ZC Series and Bell Engines.
L128: Machined surface on crankcase, specifical-
ly, Arrow and Continental Emsco/Climax.
Specifications
Maximum Pressure Rating (all models):
30 psi (207 kPa) [2.07 bar]
L100 and L100W Case: Die cast aluminum Float: Brass Rating: 2 A @ 30 VAC/DC Vent Fitting:
1
/4 in. (6 mm) tube x 1/8 NPT
Inlet Fitting: Hex Nipple
1
/4 NPT
Hardware (shipped loose)
L100:
Copper Tubing: 1/4 x 48 in. dia.
(6 mm x 1.2 m)
Reducer Bushing: 1/2 NPT x 1/4 NPT
Close Nipple: 1/2 NPT
Tee: 1/2 NPT, black pipe
Wire: 16 AWG x 24 in. (1.5 mm2x 610
mm)
L100W:
Vent Tube: 1/4 x 3-3/8 in. (6 x 86 mm)
Reducer Bushing: 3/4 NPT x 1/4 NPT
Close Nipple: 3/4 NPT
Tee: 3/4 NPT, black pipe
Wire: 16 AWG x 24 in. (1.5 mm2x 610
mm)
L120 Case: Cast Aluminum Float: Brass Rating: 2 A @ 30 VAC/DC Mounting Bolts:
1
/4-20 UNC–2A (4 req'd)
L127 and L128 Case: TROGAMID
®
Nylon
Float: Brass Rating: 2 A @ 30 VAC/DC Wire: 16 AWG x 48 in. (1.5 mm
2
x 1.2 m)
Mounting Bolts:
L127:1/4-20 NC x 2 in. (4 required)
L128:3/8-16 NC x 3/4 in. (2 required)
Warranty
A limited warranty on materials and workmanship is given with this FW Murphy product. A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm
L100
L120
L127/L128
Models available with high and low options. See How to
Order on reverse side.
**Products covered by this bulletin comply with EMC
Council directive 89/336/EEC regarding electromagnetic
compatibility except as noted.
**
L-5937B
Revised 06-06
Catalog Section 15
Float Actuated Oil Level Swichgage
®
instrument
L-5937B page 2 of 2
Typical Wiring Diagram
How to Order
Specify base model designator and options in sequence shown below. Example: L100-HL.
Specify part number when ordering Repair Parts or Kit. Example: 15000181
Repair Kit L100 and L100W:
15000103: Consists of glass, gasket, 4 screws, contact assembly, and float assembly.
Repair Parts L120 :
15010186: Contact screw assembly. 15010234: Float assembly.
Repair Kits L127 and L128:
15000180: Includes case, contact, 4 mounting bolts, and 2 gaskets. 15000181 (L127 only): Includes 4 mounting bolts, 2 gaskets, float assembly, ground strip, wire, and mounting plate. 15000188 (L128 only): L128 less case assembly.
Dimensions
L100 and L100W
L120
L127 and L128
C
L
27/32 in. (21 mm)
3-1/8 in. (79 mm)
2-1/8 in. (54 mm)
2-1/8 in. (54 mm)
4-5/16 in. (110 mm)
3-3/8 in. (86 mm)
2-7/32 in.
(56 mm)
Mounting Holes 4 places,  5/16 in. (8 mm) diameter
2-7/32 in.
(56 mm)
2-3/4 in. (70 mm)
2 in.
* *
(51 mm)
2-1/2 in.*
(64 mm)
2-15/64 in.
(57 mm)
Mounting
**
holes 4 places 5/16 in. (8 mm) diameter
2-15/64 in.
(57 mm)
** Applies to L127 only
* Applies to L128 only
47/64 in.
(19 mm)
3/8 in.
(10 mm)
17/32 in. (13 mm)
1-17/32 in.
(39 mm)
Mounting
holes 2 places
5/16 in. (8 mm)
Oil inlet  holes
L128 Mounting Dimensions
Base Model (refer to “Application” section)
L100: Sight gage with low limit switch. L100W: Same as L100 except fittings. L120: Sight gage with low limit switch. L127: Sight gage with low limit switch. L128: Sight gage with low limit switch.
____ - ____
Shipping Weight:
L127: 8 oz (0.23 kg)
L128: 10 oz (0.36 kg)
Shipping Dimensions (L127 and L128):
4-3/4 x 4-3/4 x 3-1/4 in. (121 x 121 x 83 mm)
Shipping Weight: 1 lb 8 oz (0.68 kg) Shipping Dimensions: 4-3/4 x 4-3/4 x 3-1/4 in. (121 x 121 x 83 mm)
Shipping Dimensions:
L100: 5-1/4 x 5-1/4 x 5-1/2 in.
(133 x 133 x 140 mm)
L100W: 4-3/4 x 4-3/4 x 3-1/4 in.
(121 x 121 x 83 mm)
Shipping Weight:
L100: 2 lbs. (0.91 kg)
L100W: 2 lbs. (0.91 kg)
Option
Blank: Low contact. LF: Less fittings and hardware.
Printed in U.S.A. 06 8 789
Below is a typical wiring diagram for a level Swichgage instrument. A Swichgage instru­ment can be connected to a Murphy magnetic switch or magneto. Switch Contact Rating is 2 A @ 30 VAC/DC resistive.
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time. MURPHY, the Murphy logo, and Swichgage®are registered and/or common law trademarks of Murphy Industries, Inc. This document, including textual matter and illustrations, is copyright protected by Murphy Industries, Inc., with all rights reserved. (c) 2006 Murphy Industries, Inc.
www.fwmurphy.com
918.317.4100 Email: sales@fwmurphy.com
Murphy 
Float
magnetic  switch
OR
Magneto
Loading...