Murphy AS730 User Manual

AUTOSTART 730 (AS730 series)
The Generator Controls Division of
R
(MS5261)
gen. frequency measurement range
PROGRAMMABLE GENERATOR CONTROLLER
The Autostart 730 provides for the fully automatic or manual control of a standby generator. The unit has similar control and instrumentation features to the Autostart 710, but with the addition of 3 phase generator voltage and current measurement, display and fault tripping.
Key features
front facia push button keys
32 character, back-lit liquid crystal display (LCD)
Fully programmable generator control options, timers,
inputs, outputs and fault protections
Monitoring, display and programmable fault trips for
generator speed/frequency, 3 phase voltage and 3 phase current with IDMT response.
Comprehensive automatic fault protection system:–
up to 5 programmable fault inputs, overspeed, charge fail, emergency stop, and high and low battery volts
6 programmable outputs, each with over 40 different
function (or ‘action’) types.
Operation
Control of the Autostart is via 4 front facia keys:­ON/MODE Turns on the Autostart and allows selection
of Auto or Manual modes.
PAGE Used to scroll through measured generator
parameters, such as 3 phase voltage and current, engine oil pressure and temperature, hours run and battery voltage.
SELECT Used in the programming of Autostart OFF Turns the Autostart off, disabling the
generator and resetting any fault condition.
These keys are also labelled with used in the programming of each Autostart (see overleaf). Two front facia LEDs indicate the selected operating mode: green for Auto, amber for Manual.
Control Outputs
Dedicated relay outputs are used for engine fuel and starter motor control. The AS730 has 6 programmable outputs, each of which may be set up for use as one of over 40 function types, e.g. preheat (4 types), engine running, individual faults (e.g. overspeed, overcurrent, start fail, oil pressure, etc.), energised to stop fuel, etc.
Fault Protection and Alarm System
The Autostart 730 has a comprehensive fault detection, warning and automatic response system:-
Dedicated inputs for low oil pressure and high engine temperature sensors, either switch or analogue type. The use of analogue sensors allows for pre-warning as well as shutdown alarms, and real-time display of oil pressure and engine temperature.
Three programmable inputs for use with remote fault switches. The inputs can be set to give a warning only, generator load release or shutdown response.
User set trip levels and response for generator speed/ frequency, 3 phase voltage and 3 phase current.
symbols,
Issue 4, revised 06/99
M011001
Catalogue section 75
Product Specification
Power supply:
Operating voltage: steady state range crank brown-out Current consumption typically 200 mA
Inputs:
DC inputs:-
positive input defined as: 80% to 100% of battery +ve negative input defined as: –1V to +2V w.r.t. battery –ve
Input 1 (oil pressure) and Input 2 (engine temperature)
Inputs 3 - 5 switch (open or closed),
Generator AC inputs:-
operating voltage range 90 – 300 V AC rms L–N gen. frequency display accuracy <= 2% of full scale
gen. frequency display resolution 1 Hz.
Magnetic pickup:
operating voltage range 7 – 80 V AC rms frequency measurement range 0 – 10 kHz. generator RPM display accuracy <= 2% of full scale generator RPM display resolution 10 RPM
AC current sensing inputs:
operating range designed for use with 5 Amp CT's
Outputs: (all ratings for resistive load)
Start and fuel relays SPNO contacts (switched +ve) Programmable outputs 1 – 3 – ve DC (open collector transistor) Programmable output 4 – ve DC (switched relay) Programmable output 5
(default setting: Common Alarm) Programmable output 6 (default setting: Gen. Contactor)
Physical:
Overall dimensions (W x H x D) 144 x 96 x 162 mm Panel cut-out size (W x H) DIN standard 140 x 92 mm Weight approx. 720 g Operating ambient temperature –10 to +55 oC
In order to consistently bring you the highest quality,
full featured products, we reserve the right to change our
specifications and designs at any time.
5 – 40 V DC continuous
to 0 V for >=100mS
switch (open or closed) or analogue
(Murphy, Datcon, VDO 5 or 7 bar),
wired to –ve DC
wired to +ve or –ve DC
0 – 99 Hz.
primary ratings 10 to 5000 Amps
rated 16 A max. @ 24 V DC
250 mA max. @ 33 V DC
5 A max. @ 24 V DC
+ ve DC (switched relay)
5 A max. @ 24 V DC
volt free SPNO relay
5 A max. @ 240 V AC
Additional fault alarms:-
+ ve DC power supply
+ ve DC (relays)/Emerg. stop
Communications Port
–ve DC
Frank W. Murphy Manufacturer Frank W. Murphy Southern Division
Frank W. Murphy Ltd.
Macquarrie Corporation
email: murphy@macquarrie.com.au
Murphy Switch of California
Murphy de Mexico S.A. de C.V.
Frank W. Murphy Pte, Ltd. Frank W. Murphy Ltd. en France
Warnings: low and high battery voltage, charge fail
and magnetic pickup fault
Shutdowns: emergency stop, start fail and system fail.
Programmable functions
The AS730 has all the programmable functions found on the Autostart 710 – timers, alarm configurations, trip levels and programmable inputs/outputs – plus the following:-
Generator under voltage trip, under voltage reset,
over voltage trip levels.
Generator full load current, IDMT response constant
and instant trip level.
The Autostart may be programmed by use of the front facia keys: to prevent end-user tampering, entry to program mode is restricted by use of a code number.
The addition of a small RS232 interface allows the AS730 to be connected to a remote (IBM compatible) computer, either directly or over a modem link; Murphy Modex communication software allows a PC operator to program, monitor and control the Autostart from a remote location.
When ordering, please specify:-
a) Unit type (Autostart 730S)
Accessories:-
AS7CA 9 way (interface) to 9 way (PC) comms lead AS7CB 9 way (interface) to 25 way (PC) comms lead AS7CC Local communications interface AS7CD Modem communications interface AS7CK AS7xx communication and programming software
Rear Facia & Electrical Connection
Generator
L1
70
L2 L3
0 - 300 VAC
N
Line - Neutral L1 L1 return L2 L2 return L3 L3 return
voltage
Generator
current
0 - 5 Amp
CT's
5 – 40 VDC
– ve DC < 250 mA
70 71 72 73 74 75 76 77 78 79
16
Input 1: low oil pressure
17
Input 2: high engine temp.
18
Input 3: programmable
19
Input 4: programmable
20
Input 5: programmable
Index Pin21
22
Fuel output
23
Starter output
24
Output 5 (alarm): + ve, < 5A
25
NO
26
CO
27
Man. Start
28 29
Live
30
Neutral
71 72 73 74 75 76 77 78 79
1
–ve DC supply
2
Charge fail input 3 4 5
Magnetic pickup input 6
Output 1 7
Output 2 8
A800 enable output 9
Output 3: – ve, < 250mA
10
Output 4: – ve DC, < 5 A
11
Remote start/mains fail input
12
- No connection -
13
- No connection -
14
- No connection -
15
- No connection -
10 11 12 13 14 15
1 2 3 4 5 6 7 8 9
16 17 18 19 20
21
22 23 24 25 26 27 28 29 30
+ ve DC < 16 A
Output 6 (gen. contctr) volt free, < 5 A
Man. Stop
– ve
Generator AC 300 VAC max.
Typical Connection
M
L1
A
L2
I
L3
N
N
S
L1
UVR500
1 2 3 4 5 6
+ve DC
fuse
+
WL
A
magnetic
pickup
Autostart
5A
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15
L1
LOAD
L2
730
generator
L3
N
contactor
70 71 72 73 74 75 76 77 78 79
16 17 18 19 20
21
22 23 24 25 26 27 28 29 30
GCR1
1A
1A
MCCB
GCR
1A
HET
inputs
RFL
start
manual
stop
manual
RST
RAL
fuel
starter
alarm
IP3
IP4
IP5
LOP
G
L1
E
L2
N
L3
E
N
R A T O R
mains
contactor
L2
L3
N
MCR
RPO1
RPO2
RPO3
RPO4
MCR1
Emergency
Stop
Incorporating Modex Automation
Church Road, Laverstock, Salisbury U.K.
Since 1939
PO Box 470248, Tulsa, Oklahoma 74147, USA Tel: + 1 918 627 3550 Fax: + 1 918 664 6146 email: sales@fwmurphy.com web: http://www.fwmurphy.com
Tel: + 44 1722 410055 Fax + 44 1722 410088 Pour service en Français, tél: + 44 1722 410697 email: sales@fwmurphy.co.uk web: http://www.fwmurphy.co.uk
Tel: +33 (1) 30 76 26 26 Fax: +33 (1) 30 76 39 89 Direct usine Tel: + 44 1722 410697 email: sales@fwmurphy.co.uk
No. 2 Tuas South Street 2, Sprintecs Building 02-01/02, Singapore 637895 Tel: + 65 863 1398 Fax: + 65 863 0208 email: fwmsales@fwmurphy.com.sg
PO Box 1819, Rosenberg, Texas 77471, USA Tel: + 1 281 342 0297 Fax: + 1 281 341 6006 email: sales@fwmurphy.com
41343 12th Street West, Palmdale, CA 93551, USA Tel: + 1 661 272 4700 Fax: + 1 661 947 7570 email: sales@murphyswitch.com web: http://www.murphyswitch.com
1620 Hume Highway, Campbellfield, Vic. 3061 Australia Tel: + 61 3 9358 5555 Fax: + 61 3 9358 5558
Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje San Luis Potosí, S.L.P. México 78384 Tel: + 52 48 206264 Fax: + 52 48 206336 email: murmexsl@sanluis.podernet.com.mx
Loading...