I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
M-OBR4-GRD Series
RECESSED OUTDOOR BOTTLE FILLER WITH
BI-LEVEL DRINKING FOUNTAIN
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:
1.800.591.9360
Technical Assistance Fax: 1.626.855.4894
NOTES TO INSTALLER:
1. Please leave this documentation with the owner of the fixture when finished.
2. Please read this entire booklet before beginning the installation.
3. Check your installation for compliance with plumbing, electrical and other applicable codes.
LIMITED WARRANTY - UNITED STATES & CANADA
Murdock warrants that its products are free from defects in material or workmanship under normal use and
service for a period of one year from date of install or for 18 months after the date of shipment from the factory,
whichever comes first. The sealed refrigeration system is warranted for five years. Murdock’s liability under this
warranty shall be discharged solely by replacement or repair of defective material, provided Murdock is notified in
writing within one year from date of shipment, F.O.B. Industry, California.
This warranty does not cover installation or labor charges and does not apply to materials, which have been
damaged by other causes such as mishandling, improper care or abnormal use. The repair or replacement of the
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this
warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges
caused by defects in the materials, or any delay in the repair or replacement thereof. This warranty is in lieu of all
other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard
or non-compliance with these instructions will constitute an abnormal use condition and void the warranty.
Stainless steel must be protected on job site during construction and must be properly maintained after the water
has been introduced into the water cooler or drinking fountain, or Murdock’s limited warranty is void.
Test rating conditions are
compliant with ARI 1010.
Federal
Public Law
111-380
(No Lead)
Member of
MURDOCK
15125 Proctor Ave.
City of Industry, CA
91746 U.S.A.
Phone 800-591-9360
626-336-4561
Fax 626-855-4894
www.murdockmfg.com
CONTEMPORARYWATER COOLERS
OUTDOOR BOTTLE FILLERS
INSTALLATION/MAINTENANCE INSTRUCTIONS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
IMPORTANT
This fixture is intended to dispense water that has been lowered in temperature, but otherwise remains
unchanged by the materials in the drinking fountain.
NOTICE
A dielectric coupling must be used to connect the drinking fountain to the water supply. A nonmetallic coupler is
furnished with this water cooler to meet this requirement.
DIMENSIONAL DRAWING
Prior to roughing in, consult with local, state, and federal codes for proper mounting height.
M-OBR4-GRD Recessed Outdoor Bottle Filler with Bi-Level Drinking Fountain
18"
[457]
5
32
8
[829]
3
24
4
[629]
8"
[203]
"
"
19" [483]
1
36
"
2
[927]
5
*37
"
8
[956]
8"
[203]
*29
[752]
SHOWN WITH
2x4 STUD WALL
General Notes:
13"
[330]
3
4
"
4
[121]
5
12
8
[320]
"
1. All dimensions are in inches [mm]
*2. Dimensions shown are for recommended adult height.
Adjust vertical dimensions as necessary to comply with
federal, state & local codes
3. Stop valve not provided
4"
[102]
3
1
8
[35]
"
20
3
"
4
[527]
8"
[203]
13
1
"
4
[337]
6"
[152]
5
"
8
3
*33
8
[848]
"
NOTES: Dimensions shown for Adult ADA compliant installation. For Child ADA compliant parallel approach installation,
decrease height of installation by 3 inches. Provide clear floor space as required. Adjust vertical dimensions as required to
comply with federal, state, and local codes.
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-960-001
Page 2 of 17
M-OBR4-GRD
Member of
New: 12/01/17
CONTEMPORARYWATER COOLERS
OUTDOOR BOTTLE FILLERS
INSTALLATION/MAINTENANCE INSTRUCTIONS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
IMPORTANT:
1.Water Supply Service Stop Valve, and Water Connections to be supplied by others in accordance with local
codes.
2.Waste is 1-1/4” Outer Diameter. Drinking Fountain water inlet is 1/4” outer diameter Push-In Fitting. Bottle
Filler water inlet is 1/4” Outer Diameter Push-In Fitting. Water line by others.
3.Completely flush supply lines of all foreign debris before connecting to fixture.
4.Do NOT solder tubes inserted into the chiller, bottle filler or the fountain strainer as damage to the o-rings on
the push-in fittings may result.
5.All burrs must be removed from outside of cut tubes before inserting into strainer or other components.
6.WARNING: Warranty is voided if installation is not made following current Murdock Mfg. installation
instructions and if components are assembled to the fixture that are not approved by Murdock Mfg.
7.Fixture operates within water pressure range of 25 PSIG (174 kPa) to 105 PSIG (724 kPa).
8.Per UPC 609.10-All building water supply systems in which quick acting valves are installed shall be
provided with devices to absorb the hammer caused by high pressure resulting from the quick closing of the
valve. These pressure-absorbing devices shall be approved mechanical devices. Water pressure-absorbing
devices shall be installed as close as possible to the quick closing valve
PRIOR TO INSTALLATION:
1. Read all installation instructions carefully, before proceeding.
2. Carefully remove all fixture components from packaging, preventing scratching or damage. Inspect fixture and
all parts from damages and all parts that are bolted on.
3. Provide mounting surface, adequate to support the fixture and loads on the fixture.
4. Provide rough-ins as shown on the roughing-in and dimensional drawing, including water supply, drain pipe
and gravel drain well. (See rough-in details)
5. Completely flush water supply lines of all foreign debris, before connecting to the fixture.
DRINKING FOUNTAIN START UP:
1.Before connecting power supply, but after thoroughly flushing the supply line and connecting it to the cooler,
turn on building water supply and check all connections for leaks.
2.Air within the drinking fountain system or the structure supply piping will cause an irregular bubbler outlet
stream until purged out by incoming water. Covering the bubbler with a clean cup (or similar object) is
recommended when first activating drinking fountain to prevent excessive splashing.
3.Depress front push pad until steady water stream is achieved.
4.If water flow requires adjustment, insert a slotted narrow blade screwdriver in the hole centered on the
underside of the fixture in the knee clearance area up to the flow regulator. Turning clockwise will increase
flow and turning counterclockwise will decrease flow.
5.Recheck all water connections with water flowing through system.
BOTTLE FILLER START UP:
1.Pushbutton Operated: Air within the bottle filler system or the structure supply piping will cause an irregular
spout outlet stream until purged out by incoming water. Press and hold pushbutton until steady water stream
is achieved
2.Sensor Operated: Hold container to be filled just below the sensor in the center of the filler spout and then
move the container upward and water flow will start automatically. When the container is almost filled, lower
the container below the sensor until the water stops flowing. (See label on the bottle filler.)
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-960-001
Page 3 of 17
M-OBR4-GRD
Member of
New: 12/01/17
CONTEMPORARYWATER COOLERS
OUTDOOR BOTTLE FILLERS
INSTALLATION/MAINTENANCE INSTRUCTIONS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
Mounting Installation
Provide wall opening as indicated in rough-in detail provided. Block-out for bottle filler box and provide structural support for
1
mounting plate ø1/4” anchoring holes provided.
7
4"
Note:
Electrical Service
Required for Plug-In
5
"
8
36"
14
1
"
2
3
"
8
1
"
2
7
19"8
1
3
"16"
13
1
16
4
"
2
Transformer; Transformer
does not sit inside Botle
Filler Box.
1
"
4
3
1
28
"
2
1
12
"
2
7
26
A.F.F.
1
1-1/4" O.D. Drinking Fountain Waste
2
1-1/4" O.D. Bottle Filler/Drinking Fountain Waste
3
1/4" O.D. Drinking Fountain Supply Inlet
4
Mounting Holes
4
"
8
1
Stud Frame
Wall Spacing
16"
7
5
8
5
21"
1
32
"
8
Ø1"
"
2"
3
2
16"
1
4
"
2
1
4
"
2
5
1/4" Anchoring Hardware, by others
6
5/16" Threaded Studs
7
2x6 Stud Wall, for reference only
8
GFCI Electrical Service Protected Circuit
for -SO Sensor Operated units, by others
6
8
NOTES: Dimensions shown for Adult ADA compliant installation. For Child ADA compliant parallel approach installation,
decrease height of installation by 3 inches. Provide clear floor space as required. Adjust vertical dimensions as required to
comply with federal, state, and local codes.
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-960-001
Page 4 of 17
M-OBR4-GRD
Member of
New: 12/01/17
CONTEMPORARYWATER COOLERS
OUTDOOR BOTTLE FILLERS
INSTALLATION/MAINTENANCE INSTRUCTIONS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
Mounting Installation (Continued)
Separate Fixture Panel, Bottle Filler Box, Mounting Plate and #10-32 x 1/4"
2
Screws from packaging careful to avoid damage to fixtures and fixture
sub-assemblies.
1
2
Bottle Filler Panel
1
Mounting Plate
2
Waste Outlet, Ref. only
3
(Plumbing may vary)
Bottle Filler Box
4
(4) #10-32 x 1/4" Phillps
5
Head Screws
4
3
Supporting Mounting Plate against wall, align Bottle Filler opening and
3
Mounting Plate Ø1/4" Anchoring holes with structural support before fixing to
wall with installer provided Anchoring Hardware.
5
36"
3
1
2
4
Mounting Plate
1
2x6 Stud Frame
2
Finish Wall, Ref. only
3
Anchoring Hardware,
4
provided by others
Finished
Floor
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-960-001
Page 5 of 17
M-OBR4-GRD
28
26
1
"
2
7
"
8
Member of
New: 12/01/17
CONTEMPORARYWATER COOLERS
OUTDOOR BOTTLE FILLERS
INSTALLATION/MAINTENANCE INSTRUCTIONS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
Bottle Filler Installation
Position Bottle Filler Box in the center of the Mounting Plate
1
opening and secure with #10-32 x 1/4" Phillips Head Screws.
Note: Cutoff 2-1/2" of material from the tailpiece. See Detail A.
1
4
3
5
2
1
2
3
4
3
Finished Wall
Mounting Plate
Bottle Filler Panel
10-32 x 1/2" Screws
2
Finished Wall1
Mounting Plate2
Bottle Filler Box3
4
10-32 x 1/4" Screws
5
1-1/4" OD Tailpiece
Detail A
1
2
"
2
Position Bottle Filler Panel and center to Mounting Plate and
2
secure with #10-32 x 1/2" Stainless Steel Flat Head Center
Reject Hex Screw.
2
3
1
Cutoff Material
4
3
With Bottle Filler Panel installed, to open Bottle Filler, remove
3
#10-32 x 3/4" Flat Head Center Reject Screws and swing open
Bottle Filler.
1
3
2
2
1
Bottle Filler Panel
2
1
2
Bottle Filler
3
#10-32 x 3/4" Screws
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-960-001
Page 6 of 17
M-OBR4-GRD
Member of
New: 12/01/17
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.