Murdock H2O To Go BF15, H2O To Go BF16 Maintance Manual

Surface Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF15 & BF16 Series
Surface Mount Bottle Fillers
BF15 Series BF16 Series
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:
1.800.591.9360
NOTES TO INSTALLER:
1. Please leave this documentation with the owner of the fixture when finished.
2. Please read this entire booklet before beginning the installation.
3. Check your installation for compliance with plumbing, electrical and other applicable codes.
LIMITED WARRANTY - UNITED STATES & CANADA
Murdock warrants that its products are free from defects in material or workmanship under normal use and service for a period of one year from date of shipment from the factory. Murdocks’s liability under this warranty shall be discharged solely by repair or replacement of defective material, provided Murdock is notified in writing within the time periods described above.
This warranty does not cover installation or labor charges and does not apply to materials, which have been damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges caused by defects in the materials, or any delay in the repair or replacement thereof. This warranty is in lieu of all other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard or non-compliance with these instructions will constitute an abnormal use condition and void the warranty. Stainless steel must be protected on jobsite during construction and must be properly maintained after the water has been introduced into the water cooler or drinking fountain, or Murdock’s limited warranty is void.
LIMITED EXPORT WARRANTY - One year on parts only.
Murdock™ assumes no responsibility for use of void or superseded data. © Copyright Murdock Mfg., City of Industry, CA Member of Morris Group International. Please visit
www.murdockmfg.com for most current
specifications.
7020-957-001 Date: 08/02/19
COMPLIES WITH
Federal Public Law 111-380 (No Lead)
Member of
www.murdockmfg.com
MURDOCK
15125 Proctor Ave. City of Industry, CA
91746 U.S.A.
Phone 800-591-9360
626-336-4561
Fax 626-855-4894
Surface Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
PRIOR TO INSTALLATION
Important: Some options may slightly alter installation. To ensure proper installation, review the manual thoroughly and verify rough-ins before beginning any work. File this Manual with the owner or maintenance personnel upon completion of installation.
Fixture mounting requirements: Industry standard wall construction, adequate to support the fixture and (installer provided) wall
anchors sufficient to secure the fixture.
Fixture operates within water pressure range of 20 to 105 PSIG. Murdock will not warranty fixtures damaged when connected
to supply lines with flow pressure lower than 20 PSIG or higher than 105 PSIG.
Per UPC 609.10- All building water supply systems in which quick acting valves are installed shall be provided with devices to
absorb the hammer caused by high pressure resulting from the quick closing of the valve. These pressure-absorbing devices shall be approved mechanical devices. Water pressure-absorbing devices will be installed as close as possible to the quick closing valve.
Water supply inlet is 3/8” O.D. Copper Tube. Completely flush supply of all foreign debris before connecting to fixture. Bottle Filler is designed to provide trouble- free
drinking water unaffected by fixture connection tubing and fittings and not cause problems with taste, odor, color or sediment.
Electrical Receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth grounded per N.E.C. (National
Electrical Code).
DIMENSIONAL DRAWING
Prior to roughing in, consult with local, state, and federal codes for proper mounting height.
BF15/16 Surface Mounted Bottle Filler
3
7
"
8
(187)
OPTIONAL -BCD BOTTLE
COUNTER AND FILTER
REPLACEMENT DISPLAY
LED LIGHTING
WITH -BCD OPTION
ONLY
1
18
4
[464]
GENERAL OTES:
1. ALL DIMENSIONS ARE IN INCHES (MM)
"
7
4
"
8
[124]
5
12
"
8
29
1
"
2
[321]
[749]
1
5
"
1
34
2
[876]
A.F.F.
"
12
1
"
8
[308]
8
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-957-001
Page 2 of 13
Member of
Revised: 08/02/19
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
INSTALLATION INSTRUCTIONS:
Surface Mounted Bottle Fillers
Place unit onto a horizontal surface. Unscrew Top Screws with 1/8"
1
Allen Wrench (not included) and place in a secure location for later use. Open unit by swinging Mounting Panel down.
1
2
Remove Bottle Filler Housing from unit by removing one Screw from
2
the Hinge and sliding the Bottle Filler Housing out. Set aside for later use in the Manual.
1
Bottle Filler Housing
2
Mounting Panel
3
#10-32 x 3/4" Phillips Round Head Screw
1
#10-32 x 1" Allen Button Head Screw
2
Bottle Filler Housing
3
3
3
Mounting Panel
2
2
1
Locate and attach Mounting Panel to finished wall. Secure Mounting
3
Panel with Anchoring Hardware, provided by installer. See step four for rough-in layout.
1
2
3
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-957-001
2
Page 3 of 13
1
Finished Wall
2
Mounting Panel
3
Anchoring Hardware, by others
1
Member of
Revised: 08/02/19
Surface Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
INSTALLATION INSTRUCTIONS CONTINUED:
Provide wall openings as indicated in rough-in detail provided, ensuring to block out the electrical service rough and Waste
4
outlet for 1-1/2" P-Trap. Use Mounting Panel as template.
1
18
"
29
3
3
"
4
TYP.
7
4
"
8
TYP.
1
9
"
2
TYP.
1
"
2
12"
TYP.
X X X
4
7"
C
L
6
4
5
3
General Notes:
1. Dimension indicated with (*) is for 34-1/2" deck height. Adjust accordingly for preferred deck height.
2. Anchoring is required for holes marked with (X). Auxiliary holes available if required.
1
34
"
Deck Height Notch
2
A.F.F.
X X X
1
3
"
1
4"
1
*24
"
4
TYP.
A.F.F.
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-957-001
7
*27
8
A.F.F.
"
2
1
6
"
4
2
*26
A.F.F.
Page 4 of 13
1 4
*29
A.F.F.
"
1
"
8
110VAC Electrical Duplex1 Receptacle, by others
2
3/8" NCT Supply Inlet
3
Waste Outlet for 1-1/2" P-Trap
4
Mounting Panel
5
Ø1/4" Holes, for Anchoring Hardware, by others
6 Housing, Shown for Ref.
Member of
Revised: 08/02/19
Surface Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
INSTALLATION INSTRUCTIONS CONTINUED:
With the Mounting Panel secured to finished wall, install P-Trap Waste Outlet. P-Trap must not extend more than 4-1/4" from finished wall.
1
4
4
Max
Top View
Connect 3/8" O.D. "Y" Strainer to main water supply. Recommend using angle stop for easy maintenance. Angle stop must not extend more than 3-1/2" from finished wall.
1
Mounting Panel
2
Angle Stop Recommended, by others
3
"Y" Strainer
1
Mounting Panel
2
P-Trap
3
Drain Tray
"
1
3
"
2
Max
Re-mount Bottle Filler Housing by reversing steps taken in Step 2.
1
Bottle Filler Housing
2
Mounting Panel
3
#10-32 x 3/4" Phillips Round Head screw
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-957-001
Page 5 of 13
Member of
Revised: 08/02/19
Surface Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
INSTALLATION INSTRUCTIONS CONTINUED: (BF15)
With Bottle Filler Housing secured to unit, connect water supply line.
8A
Keep supply line within plastic cable holders to prevent supply line from getting pinched or damaged. If Fixture is BF16, see steps 8B-9B.
1
4
5
2
1
Mounting Panel
2
Bottle Filler Housing
3
Valve Water Supply Outlet Elbow
4
Bottle Filler Water Supply Inlet Tubing
5
Plastic Cable Holder
1/4"
Min.
3
1
Mounting Panel
2
Bottle Filler Housing
3
1/8" O.D. Polyethylene Air Line
4
Valve Air Line Inlet
5
Plastic Cable Holder
With Water Supply Line properly secured, connect 1/8" O.D.
9A
Polyethylene Air Line to valve. Keep Air Line within the plastic cable holders to prevent supply line from getting pinched or damaged. Turn on water and check for Leaks throughout the system.
1
5
2
3
4
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-957-001
Page 6 of 13
Member of
Revised: 08/02/19
Surface Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
INSTALLATION INSTRUCTIONS CONTINUED: (BF16)
With Bottle Filler Housing secured to unit, connect water supply line
8B
and electrical wiring as shown below. Keep supply line and wiring within plastic cable holders to prevent supply line and wiring from getting pinched or damaged. If fixture is BF15, see steps 8A-8B.
1
7
3
4
6
5
2
1
Mounting Panel
2
Bottle Filler Housing
3
Solenoid Valve Electrical Wiring
4
Bottle Counter Display / Sensor Wiring
5
Solenoid Valve Water Supply Outlet Elbow
6
Bottle Filler Water Supply Inlet Tubing
7
Plastic Cable Holder
1
Mounting Panel
2
Bottle Filler Housing
3
Power Supply
4
110VAC Duplex Receptacle
Plug-in power supply, turn on water and check for leaks
9B
throughout the system.
4
3
1
2
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-957-001
Page 7 of 13
Member of
Revised: 08/02/19
Surface Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
INSTALLATION INSTRUCTIONS CONTINUED:
With fixture tested, hook Lanyard from Bottle Filler Housing to
10
Mounting Panel and tighten Screw.
3
4
2
1
11
1
Bottle Filler Assembly
2
#10-32 x 1" Allen Button Head Screw
3
Bottle Filler Housing
4
Mounting Panel
1
Bottle Filler Housing
2
Lanyard
3
Mounting Panel
4
Lanyard Mounting Screw
2
Lift up from Fill Spout area to close the unit by swinging Bottle Filler Housing up and secure with Screws from step 1. Do not force closed. Address any interference if necessary. Do not over-tighten.
4
2
3
To open unit for maintenance purposes, remove Top Screws. Lift
12
Bottle Filler Housing up from Fill Spout area then pull away from wall.
2
1
3
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-957-001
Page 8 of 13
4
1
Bottle Filler Assembly
2
#10-32 x 1" Allen Button Head Screw
3
Bottle Filler Housing
4
Mounting Panel
1
Member of
Revised: 08/02/19
Surface Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
ELECTRICAL INSTALLATION:
NOTE: PLUG-IN POWER IS A STANDARD FEATURE FOR BF16.
1A. Plug-In Operation: Plug transformer provided into GFCI protected electrical service, used by the Bottle Filler.
2. Connect the Sensor Wires to either the Solenoid Valve or -BCD Bottle Counter Display (if equipped).
START UP:
1. Air within the Bottle Filler System or the structure supply piping will cause an irregular Spout outlet stream until purged out by incoming water. Hold cup (or similar object) directly below Filler Spout is recommended when first activating Bottle Filler to prevent excessive splashing. Activate sensor until steady water stream is achieved.
OPERATING INSTRUCTIONS:
Position container to be filled directly in front of the Sensor and centered under the Filler Spout. Water flow starts
automatically. When the container is almost filled, remove container. The water will stop flowing.
BOTTLE COUNTER ADJUSTING & RESETTING INSTRUCTIONS:
NOTE: Bottle Counter Has Multiple Functions
Reset/ Mode Button
• Counts refilled bottles
• Adjustable for units with and without Filters
• “REPLACEMENT FILTER” alert function
• Alert reset, when Filter is replaced
Description
Illuminated LCD Display counts bottles and has a Filter replacement alert function.
Bottle Counting Function
The software applies a flow volume of approximately 16.9 fl oz (volume in standard size plastic water bottle) to each bottle counted. If the flow volume is less than 16.9 fl oz, there will be no count but the volume will accumulate, so that part way through the next cycle the total bottle count will change.
-BCD Bottle Counter Display with Illuminated Display
Fill Spout
Sensor
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-957-001
Page 9 of 13
Member of
Revised: 08/02/19
Surface Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
FILTER REPLACEMENT FUNCTIONS:
NOTE: When the volume accumulates to programmed Filter volume, the “REPLACE FILTER” alert will
appear on the display every time the Bottle Filler is activated.
Counter Modes:
Located on the back of the Display you will find the Reset/Mode Button for the mode settings. The Reset/Mode Selection Button is accessible by removing the Housing, then locate the large hole in the back of the Display Mounting Bracket. Use your finger or nonconductive object to depress the Reset/Mode Selection Button.
CAUTION: DO NOT USE SHARP OR METAL OBJECTS!!!
With this Reset/Mode Button, you are able to indicate whether the unit has a Filter or does not have a Filter. The Reset/Mode Button is used to remove the “REPLACE FILER” alert after the Filter has been replaced.
Systems With or Without Filter:
•To reset “REPLACE FILTER” message:
-Press and hold Button until “3” is displayed, then release.
•To change display to match Filter capacity:
-Press and hold Button until the Display matches installed Filter type, then release.
“FILTER NONE” “FILTER 1500” “FILTER 3000”
RESET/MODE
BUTTON
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-957-001
Page 10 of 13
Member of
Revised: 08/02/19
Surface Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
PUSH-IN FITTING INSTALLATION
NOTE: FITTINGS AND TUBE SHOULD BE KEPT CLEAN, BAGGED AND UNDAMAGED PRIOR TO INSTALLATION.
TO CUT TUBE:
Cut to fit length of 1/4” PE Tubing and remove any burrs or sharp edges. Ensure that the outside diameter is free from score marks. Tube ends should be square.
INSERTING THE TUBE:
1. Firmly and fully insert the Tubing end into the Push-In Fitting up to the Tube Stop located approximately 1/2” deep.
2. Pull on the fitted Tubing to ensure it is secure. Tube
should not come free from the Fitting. Water test the connection assembly prior to leaving the site to ensure there are no leaks.
DISCONNECTING THE TUBE:
Prior to disconnecting the Tube from the Fitting, ensure that the water line is depressurized. Push Collet Square towards the Push-In Fitting Body and hold. While holding the Collet in, pull on the PE Tubing to remove from the Push-In Fitting.
O-RING
O-RING
COLLET
TUBE STOP
COLLET
COLLET
COLLET
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-957-001
Page 11 of 13
COLLET
Member of
Revised: 08/02/19
Surface Mounted Bottle Fillers
ITEM #
PART NUMBER DESCRIPTION ITEM # 1 7014-27 1-002 WALL MOUNTED FRAME ASSY., BF15/16 7 7012-055 -000 FOAM PIPE INSULATION 2 CONTACT FACTORY HOUSING ASSEMBLY, BF16-BCD 8 1895-709 -000 ELBOW, 1/4" PUSH-IN X 1/4" STEM 3 4970-26 5-000 P-TRAP 9 2150-005 -199 1/8" O.D. LLDPE TUBING, CLEAR 4 0116-12 3-000 #10-32 x 1" BUTTON HEAD SCREW 10 2566-16 0-001 PBH S/T SIDE OUTLET PUSHBUTTON 5 7000-02 1-001 "Y" STRAINER 11 7001-20 3-001 AIR-TROL VALVE & BRACKET ASSY 6 2169-00 0-000 1/4" O.D. LLDPE TUBING, BLUE
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF15 PARTS LIST BOTTLE FILLER PARTS BREAKDOWN
9
10
1
11
4
6
7
5
8
2
3
PART NUMBER DESCRIPTION
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-957-001
Page 12 of 13
Revised: 08/02/19
Member of
Surface Mounted Bottle Fillers
ITEM #
ITEM # 1 701 4-271-002 WALL MOUNTED FRAME ASSY., BF15/16 9 011 6-123-000 #10-32 x 1" BUTTON HEAD SCREW 2 701 4-270-001 HOUSING ASSEMBLY, BF16-BCD 10 7000 -021-001 "Y" STRAINER 3 497 0-265-000 P-TRAP 11 2169-000-000 1/4" O.D. LLDPE TUBING, BLU E 4 256 3-381-001 SEN SOR "A" ASSEMBLY 12 7012-055-000 FOAM PIPE INSULATION 5 011 0-012-000 #6 x 3/16 " TRUSS HEAD SCREW 13 7001-200-001 SOLENOID / VALVE MOUNTING ASSY 6 071 6-111-001 BOTTLE COUNTER WITH CONNECTORS 14 0710-731-001 POWER SUPPLY 7 011 0-011-000 #6 x 3/16 " PAN HEAD SCREW 15 1895-709-000 ELBOW, 1/4" PUSH -IN X 1/4" STEM 8 701 4-253-199 SPLASH GUARD
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF16 PARTS LIST BOTTLE FILLER PARTS BREAKDOWN
7
8
7
6
14
1
13
9
1211
10
5
4
2
PART NUMBER DESCRIPTION
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-957-001
Page 13 of 13
PART NUMBER DESCRIPTION
15
3
Member of
Revised: 08/02/19
Loading...