I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF12 Series
Bottle Filler, Sensor Operated
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:
1.800.591.9360
Technical Assistance Fax: 1.626.855.4894
NOTES TO INSTALLER:
1. Please leave this documentation with the owner of the fixture when finished.
2. Please read this entire booklet before beginning the installation.
3. Check your installation for compliance with plumbing, electrical and other applicable codes.
LIMITED WARRANTY - UNITED STATES & CANADA
Murdock warrants that its products are free from defects in material or workmanship under normal use and
service for a period of one year from date of shipment from the factory. Murdocks’s liability under this warranty
shall be discharged solely by repair or replacement of defective material, provided Murdock is notified in writing
within the time periods described above.
This warranty does not cover installation or labor charges and does not apply to materials, which have been
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of
the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this
warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges
caused by defects in the materials, or any delay in the repair or replacement thereof. This warranty is in lieu of
all other warranties expressed or implied. Product maintenance instructions are issued with each unit and
disregard or non-compliance with these instructions will constitute an abnormal use condition and void the
warranty. Stainless steel must be protected on jobsite during construction and must be properly maintained
after the water has been introduced into the water cooler or drinking fountain, or Murdocks’s limited warranty is
void.
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
DIMENSIONAL DRAWING
Prior to roughing in, consult with local, state, and federal codes for proper mounting height.
BF12 Sensor Operated Bottle Filler
1
3
"
8
[79]
1
18
"
4
[464]
14"
[356]
A
6"
[152]
Optional -BCD
Bottle Counter
and Filter
Status Display
Existing Fixture
1
19
"
8
[486]
General Note:
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
5
12
"
8
[321]
1. All dimensions are in inches [MM]
7020-956-001
3
10
[264]
15"
"
8
[381]
Existing Fixture
Existing Fixture
A.Ø1/4" Holes, 10 Places for Anchoring
Hardware, provided by others
Page 2 of 15
Member of
Date: 11/29/17
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
PRIOR TO INSTALLATION
Important: Some options may slightly alter installation. To ensure proper installation, review the Manual thoroughly
and verify rough-ins before beginning any work. File this Manual with the owner or maintenance personnel upon
completion of installation.
— Fixture mounting requirements: Industry standard wall construction, adequate to support the fixture and (installer
provided) wall anchors sufficient to secure the fixture.
— Fixture operates within water pressure range of 20 to 105 PSIG. Murdock will not warranty fixtures damaged when
connected to supply lines with flow pressure lower than 20 PSIG or higher than 105 PSIG.
— Per UPC 609.10- All building water supply systems in which quick acting valves are installed shall be provided with
devices to absorb the hammer caused by high pressure resulting from the quick closing of the valve. These
pressure-absorbing devices shall be approved mechanical devices. Water pressure-absorbing devices will be
installed as close as possible to the quick closing valve.
— Water supply inlet is 3/8” O.D. Copper Tube.
— Completely flush supply of all foreign debris before connecting to fixture. Bottle Filler is designed to provide trouble
free drinking water unaffected by fixture connection tubing and fittings and not cause problems with taste, odor,
color or sediment.
— It is common for electrical equipment to be grounded to water lines either within a structure or away from it.
Because this fixture is intended to dispense water that has been lowered in temperature, but otherwise remains
unchanged by the materials in the water cooler, every attempt should be made to prevent this kind of grounding
from generating feedback into the water cooler creating electrolysis. Electrolysis will cause a metallic taste or cause
water metal content to increase.
— Electrical Receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth grounded per N.E.C.
(National Electrical Code).
INSTALLATION INSTRUCTIONS:
Remove Water Cooler Access Panel and shut-off water supply, then actuate Valve to relieve pressure. Place Screws
and Panel in secure location for further use in Manual.
1
Water Cooler
2
Water Cooler Access Panel
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 3 of 15
Member of
Date: 11/29/17
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
INSTALLATION INSTRUCTIONS CONTINUED:
Unscrew #8 x 3/8" Phillips Head Screws from Drinking Fountain
Deck as well as Drain Screw and place in a secure location for later
use in Manual.
Slightly lift Water Cooler Deck without damaging Bubbler Tubing.
Remove Tubing from Bubbler.
1
Water Cooler
2
Water Cooler Deck
3
Drinking Fountain Bubbler
4
1/4" OD PE Tubing
1
Water Cooler
2
Water Cooler Deck
3
#8 x 3/8" Phillips Head Screw
4
Drain Screw
RetroFit Water Cooler Deck by removing Bubbler from existing
Water Cooler Deck and place onto factory provided Deck. If unit is
not being Retrofit, skip to step 5.
1
Existing Water Cooler Deck
2
Factory Provided Water Cooler Deck
3
Drinking Fountain Bubbler
4
Locking Grommet
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 4 of 15
Member of
Date: 11/29/17
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
INSTALLATION INSTRUCTIONS CONTINUED:
Connect the Water Supply Tubing and Insulation to the 1/4" Push-In
Tee located on the Evaporator. The Evaporator is located within the
Water Cooler Assembly. If existing unit differs, refer to page 9 for
specific unit connections.
With the Water Supply Tubing connected to Tee, place the other end
of Tubing through the Grommet extending 4-1/2" to 5" from the Deck
as shown. Run the Power Supply Wires up through the Grommet.
1
Water Cooler Assembly
2
Water Cooler Deck
3
Evaporator
4
1/4" Push-In Tee
5
1/4" OD PE Tubing & Insulation
6
Locking Grommet
7
Power Supply
1
Water Cooler Assembly
2
Evaporator
3
1/4" OD PE Tubing & Insulation
(To Bottle Filler)
4
1/4" Push-In Tee
5
Water Supply Tubing
(To Cooler Valve Inlet)
6
Supply Inlet
4
1
" - 5"
2
Re-connect 1/4" Tubing to Bubbler and mount the Deck to the
Water Cooler. Make sure to keep the 4-1/2" to 5" from the Deck.
1
Water Cooler Assembly
2
Water Cooler Deck
3
Drinking Fountain Bubbler
4
Supply Line, Pushbutton to Bubbler
5
Locking Grommet
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 6 of 15
Member of
Date: 11/29/17
Loading...
+ 10 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.