Murdock BF11, BF12 Maintance Manual

Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF11 & BF12 Bottle Filler Series
Pushbutton Actuated
Sensor
Operated
BF11
Please visit www.murdockmfg.com for most current specifications.
BF12
TABLE OF CONTENTS
Dimensional Data/Rough-Ins. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Prior to Installation Information
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Push-In Fitting Installation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11BF11/BF12 Bottle Filler Installation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12BF11/BF12 Water Supply Tubing Diagram
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-14Optional -BCD Bottle Filler Counter Display
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Troubleshooting
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-18BF11/BF12 Repair Parts
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Warranty Information
Murdock™ assumes no responsibility for use of void or superseded data. © Copyright Murdock Mfg., City of Industry, CA Member of Morris Group International. Please visit
specifications.
7020-956-001
Date: 12/11/18
COMPLIES WITH
Federal Public Law 111-380 (No Lead)
Member of
www.murdockmfg.com
MURDOCK
15125 Proctor Ave. City of Industry, CA
91746 U.S.A.
Phone 800-591-9360
626-336-4561
Fax 626-855-4894
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
DIMENSIONAL DRAWING
Prior to roughing in, consult with local, state, and federal codes for proper mounting height.
Note: Rough-Ins are the same for BF11 & BF12
1
3
"
8
[79]
1
18
"
2
[470]
14"
[356]
6"
[152]
1
19
8
[486]
2
"
5
12
"
8
[321]
General Notes:
1. All dimensions are in inches [MM]
Optional -BCD Bottle Counter and Filter Status Display
3
10
[264]
15"
"
8
[381]
Existing Fixture
Existing Fixture
Existing Fixture
2. Ø1/4" Holes, 10 Places for Anchoring Hardware, provided by others
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 2 of 19
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
PRIOR TO INSTALLATION:
1. Some options may slightly alter installation. To ensure proper installation, review the Manual thoroughly and verify rough-ins before beginning any work. File this Manual with the owner or maintenance personnel upon completion of installation.
2. Carefully remove all fixture components from packaging, preventing scratching or damage. Inspect fixture and all parts for damage.
3. Provide rough-ins as shown on the roughing-in and dimensional drawing. (See rough-in details)
4. Water Supply Service Stop Valve, Water Connections and Electrical Connections to be supplied and installed by others in accordance with local codes.
5. Fixture mounting requirements: Industry standard wall construction, adequate to support the fixture and wall anchors (installer provided) sufficient to secure the fixture.
6. Fixture operates within water pressure range of 20 to 105 PSIG. Murdock will not warranty fixtures damaged when connected to supply lines with flow pressure lower than 20 PSIG or higher than 105 PSIG.
7. Water Supply inlet is 1/4” OD Polyethylene (PE) Tube.
8. Per UPC 609.10-All building water supply systems in which quick-closing Valves are installed shall be provided with devices to absorb the hammer caused by high pressure resulting from the quick-closing of the Valve. These pressure-absorbing devices shall be approved mechanical devices. Water pressure-absorbing devices shall be installed as close as possible to the quick-closing Valve.
9. Completely flush supply of all foreign debris before connecting to fixture. Bottle Filler is designed to provide trouble free drinking water unaffected by fixture connection tubing and fittings and will not cause problems with taste, odor, color or sediment.
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 3 of 19
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
PUSH-IN FITTING INSTALLATION
NOTE: FITTINGS AND TUBE SHOULD BE KEPT CLEAN, BAGGED AND UNDAMAGED PRIOR TO INSTALLATION.
TO CUT TUBE:
Cut to fit length of 1/4” PE Tubing and remove any burrs or sharp edges. Ensure that the outside diameter is free from score marks. Tube ends should be square.
INSERTING THE TUBE:
1. Firmly and fully insert the Tubing end into the Push-In Fitting up to the Tube Stop located approximately 1/2” deep.
2. Pull on the fitted Tubing to ensure it is secure. Tube
should not come free from the Fitting. Water test the connection assembly prior to leaving the site to ensure there are no leaks.
DISCONNECTING THE TUBE:
Prior to disconnecting the Tube from the Fitting, ensure that the Water Line is depressurized. Push Collet Square towards the Push-In Fitting Body and hold. While holding the Collet in, pull on the PE Tubing to remove from the Push-In Fitting.
O-RING
O-RING
COLLET
TUBE STOP
COLLET
COLLET
COLLET
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 4 of 19
COLLET
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF11/BF12 INSTALLATION INSTRUCTIONS
Install the newly obtained Water Cooler per the Installation Manual
1
provided with the unit. Do not install Access Panel at this time. Shut-off water supply, then actuate Valve to relieve pressure. Place Screws and Panel in secure location for further use in Manual.
4
2
3
1
1
Water Cooler Assembly
2
Access Panel
3
#8 x 3/8" Hex Washer Head Screw
4
Water Cooler Installation Manual
Remove Bottle Filler Assembly, Power Supply and Grommet from
2
packaging, careful to avoid damage to Fixture and Fixture Sub
Assemblies. Set Power Supply aside in a secure location.
1
1
Bottle Filler Assembly
2
Power Supply (Not provided with BF11)
3
Locking Grommet
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 5 of 19
2
3
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF11/BF12 INSTALLATION INSTRUCTIONS (CONTINUED)
Unfasten Screws that hold the Bottle Filler Housing to the Mounting
3
Panel. Place Bottle Filler Panel and Screws in a secure location.
3
2
3
1
1
Bottle Filler Housing
2
Mounting Panel
3
#10-32 x 1" Button Head Screw
2
Disconnect the Water Supply Insulation and Tubing from 1/4" Shut-Off
4
Valve that is located on the Mounting Panel.
2
3
1
Mounting Panel
2
Shut-Off Valve
3
1/4" OD Tubing & Insulation
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 6 of 19
3
1
Member of
Revised: 12/11/18
1
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF11/BF12 INSTALLATION INSTRUCTIONS (CONTINUED)
Connect the Bottle Filler Supply Tubing to the 1/4" Push-In Tee located
5
on the Evaporator. The Evaporator is located within the Water Cooler Assembly. If fixture differs from layout, refer to page 12 for specific unit connections.
6
5
6
5
3
1
7
3
4
1
Water Cooler Assembly
2
Evaporator
3
1/4" OD Tubing & Insulation (Bottle Filler Supply Tube)
4
7
2
1/4" Push-In Tee
5
Water Supply Tubing (To Pushbutton Valve Inlet)
6
Water Supply Tubing (To Bubbler)
7
Supply Inlet
Center Mounting Panel on top of Deck to finished wall and Secure with
6
Anchoring Hardware, by others, for Ø1/4" Mounting Holes.
7"
TYP. (A)
2
5
1
Water Cooler Assembly
2
Mounting Plate
3
Anchoring Hardware, by others
4
6x Ø1/4" Mounting Holes (A)
5
Auxiliary Ø1/4" Mounting Holes (B) (If replacing BF2)
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
1
Page 7 of 19
14" TYP. (A)
(B)
(B)
(B)
(B)
2
15"
TYP.
(A)
3
4
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF11/BF12 INSTALLATION INSTRUCTIONS (CONTINUED)
Push Tubing with Insulation and Power Wires up through hole in Basin.
7
Install Grommet.
2
4
1
4
" - 5"
2
3
1
Water Cooler Deck
2
1/4" OD Tubing & Insulation
3
Grommet
4
Power to Bottle Filler (Not required with BF11)
1
1
Water Cooler Deck
2
Mounting Plate
3
1/4" OD Tubing & Insulation
4
Shut-Off Valve
Connect Water Supply Tube to the 1/4" Shut-Off Valve that is located
8
on the Mounting Panel. Refer to page 4 for proper connection.
4
1
4
" - 5"
2
3
1
2
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 8 of 19
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF11/BF12 INSTALLATION INSTRUCTIONS (CONTINUED)
BF11 SERIES
With Mounting Panel secured, place Bottle Filler Housing on top of
9A
the Water Cooler and connect water supply line from Bottle Filler to Pneumatic Valve Outlet. Connect 1/8" Air-Line to Pushbutton and Pneumatic Valve Inlet.
3
1/4" Min.
5
1
1
Bottle Filler Housing
2
Water Cooler Assembly
3
1/4" O.D. Polyethylene Supply Line
4
Pneumatic Valve
5
Mounting Panel
6
Valve Water Supply Outlet Elbow
7
Valve Air-Line Supply Inlet
8
1/8" O.D. Polyethylene Supply Line
9
Pushbutton
4
8
7
6
9
2
1/4" Min.
8
!
IMPORTANT
FOR BF11 SERIES, FOLLOW STEP 9A FOR BF12 SERIES, FOLLOW STEP 9B
BF12 SERIES
With Mounting Panel secured, place Bottle Filler Housing on top
9B
of the Water Cooler and connect water supply line from Bottle Filler to Solenoid Valve Outlet.
3
1/4" Min.
5
1
1
Bottle Filler Housing
2
Water Cooler Assembly
3
1/4" O.D. Polyethylene Supply Line
4
Solenoid Valve
5
Mounting Panel
6
Valve Water Supply Outlet Elbow
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
4
Page 9 of 19
6
2
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF11/BF12 INSTALLATION INSTRUCTIONS (CONTINUED)
BF12-BCD SERIES
10A
Connect Electrical wiring as shown in diagram. If unit does not have
-BCD Bottle Count Display, skip to step 10B.
3
1
1
-BCD Bottle Count Display
2
Sensor
3
Solenoid Valve
4
Power Supply
5
Black Wire - BCD
2
4
5
4
BF12 SERIES
Connect Electrical wiring as shown in diagram. If unit has -BCD
10B
Bottle Count Display, see step 10A before continuing.
2
3
1
Sensor
2
Solenoid Valve
3
Power Supply
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 10 of 19
1
3
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF11/BF12 INSTALLATION INSTRUCTIONS (CONTINUED)
Connect Power Supply, turn on water and check for leaks
11
throughout the system.
3
4
1
Bottle Filler Housing
2
Mounting Panel
3
#10-32 x 1" Button Head Screw
4
Housing Bottom Flange
5
Mounting Panel Flange
1
Mounting Panel
2
Water Cooler Assembly
5
1
2
With fixture tested, install Housing to Mounting Panel. Angle
12
Housing and engage Housing Bottom Flange to Mounting Panel Flange and close unit. Secure with Screws from step 3.
3
Bottle Filler Housing
4
Power Supply
5
Solenoid Valve
3
4
2
2
1
Mount Water Cooler Access Panel to Water Cooler.
13
2
1
3
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 11 of 19
5
1
2
3
Water Cooler
Bottle Filler
Access Panel
1
2
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
ELECTRICAL INSTALLATION:
NOTE: PLUG-IN POWER IS A STANDARD FEATURE.
1A. Plug-In Operation: Plug Transformer provided into GFCI protected electrical service, used by the Bottle Filler.
2. Connect the Power Supply Wires to either the Sensor or -BCD Bottle Counter Display (if equipped).
START UP:
1. Air within the Bottle Filler System or the structure supply Piping will cause an irregular Spout outlet stream until purged out by incoming water. Hold cup (or similar object) directly below Filler Spout is recommended when first activating Bottle Filler to prevent excessive splashing. Activate Sensor until steady water stream is achieved.
OPERATING INSTRUCTIONS:
Position container to be filled directly in front of the Sensor and centered under the Filler Spout. Water flow starts
automatically. When the container is almost filled, remove container. The water will stop flowing.
BOTTLE COUNTER ADJUSTING & RESETTING INSTRUCTIONS:
NOTE: Bottle Counter Has Multiple Functions
Reset/ Mode Button
• Counts refilled bottles
• Adjustable for units with and without Filters
• “REPLACEMENT FILTER” alert function
• Alert reset, when Filter is replaced
Description
Illuminated LCD Display counts bottles and has a Filter replacement alert function.
Bottle Counting Function
The software applies a flow volume of approximately 16.9 fl oz (volume in standard size plastic water bottle) to each bottle counted. If the flow volume is less than 16.9 fl oz, there will be no count but the volume will accumulate, so that part way through the next cycle the total bottle count will change.
-BCD Bottle Counter Display with Illuminated Display
Fill Spout
Sensor
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 12 of 19
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF11/BF12 Water Supply Tubing Diagram
Install Tubing as shown below to add Bottle Filler to Fixture
Non-Refrigerated Unit
(Drinking Fountain)
Non-Pressurized Unit
(Water Cooler)
Pressurized Unit
(Water Cooler)
2 5
3
1
Water Supply Line, to Bubbler
2
Water Supply Line, to Bottle Filler
3
1/4" O.D. Push-In Tee
4
Water Supply Line, Inlet
5
Foam Insulation
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 13 of 19
Pressurized with Bottle Filler
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
FILTER REPLACEMENT FUNCTIONS:
NOTE: When the volume accumulates to Filter capacity, the “REPLACE FILTER SOON” alert will appear on
the display every time the Bottle Filler is activated.
Counter Modes
Located on the back of the display you will find the Reset/Mode button for the mode settings. The Reset/Mode Selection Button is accessible by removing the Housing, then locate the large hole in the back of the Display Mounting Bracket. Use your finger or nonconductive object to depress the Reset/Mode Selection Button.
CAUTION: DO NOT USE SHARP OR METAL OBJECTS
With this Reset/Mode Button, you are able to indicate whether or not the unit has a Filter or does not have a Filter. The Reset/Mode Button is used to remove the “REPLACE FILTER” alert after the Filter has been replaced.
Systems With or Without Filter:
•To reset “REPLACE FILTER” message:
-Press and hold Button until “3” is displayed, then release.
•To change display to match Filter capacity:
-Press and hold Button until the display matches installed Filter type, then release.
“FILTER NONE” “FILTER 1500” “FILTER 3000”
RESET/MODE
BUTTON
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 14 of 19
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
TROUBLE-SHOOTING:
1. IF LIGHT WITHIN SENSOR DOES NOT FLASH ONCE WHEN USER IS WITHIN RANGE:
a. Verify 120VAC input & 9VDC output of Transformer. b. Replace defective Transformer. c. Sensor in “Security Mode” after 20 seconds of constant detection. Remove source of detection and wait 30 seconds before checking. d. Sensor is picking up a highly reflective surface. Eliminate cause of reflection and wait 30 seconds before checking. e. Replace defective sensor.
2. IF LIGHT WITHIN SENSOR LENS FLASHES ONCE WHEN THE USER IS WITHIN RANGE:
a. Repair bad connection from Sensor to Solenoid. b. There is debris or scale in the Solenoid assembly. Remove Solenoid, pull out Plunger and Spring. Clean with scale remover solution. c. There is debris or scale in center or two holes in convolution of the water diaphragm. Remove and clean.
3. RESTRICTED OR NO WATER FLOW
a. Ensure Water Supply service stop valve is fully open. b. Verify minimum 20 PSIG supply line flow pressure. c. Check for twist or kinks in Spout Tubing. d. Check the water inlet “Y’’ Strainer. Sediment from the main supply can get trapped in the Screen along with installation materials such as pipe dope and flux. The Screen should be cleaned and checked on a regular basis and replace if needed. e. Flow Control in spout clogged, remove & clean. f. The Water Cooler may also develop a freezing condition in which the water will become frozen inside the Evaporator coil. This indicates a refrigeration problem or Thermostat failure in which case the Water Cooler needs to be checked by a qualified technician. g. No power to Transformer connections loose or wires cut.
CLEANING & MAINTENANCE GUIDE:
1. To remove water spots or rust spots, stainless steel cleaner/polish on a cloth is recommended.
2. If there are stubborn spots or if you wish to treat a scratch, synthetic abrasive general purpose pads such as Scotch-Brite is recommended.
3. Apply stainless steel cleaner/polish to the synthetic abrasive pads and carefully rub the panel with the grain.
4. Do NOT use harsh chemicals, abrasive or petroleum based cleaners. Use of these will void the Murdock warranty. DO NOT use abrasives on powder coated units.
5. Stainless steel should be kept clean at all times. If a coating of stainless steel cleaner/ polish is maintained, stainless steel surfaces will retain their new, clean, polished appearance indefinitely. Use clean mild soapy water for powder coated units.
6. Periodically remove Panels and clean out inline “Y’’ Strainer.
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
®
Page 15 of 19
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
ITEM # PART NUMBER DESCRIPTION ITEM # PART NUMBER DESCRIPTION
1 CONTACT FACTORY HOUSING ASSEMBLY, BF11 12 2150-003-199 1/8" OD LDPE TUBE, NATURAL, 3' LONG 2 7014-257-000 BOTTOM TRIM, H202GO 13 7100-441-000 LOCKING GROMMET,1.188 DIA HOLE 3 0116-123-000 #10-32 x 1" BUTTON HEAD SCREW 14 2566-160-001 (-PBH) SIDE OUTLET PUSHBUTTON 4 1895-710-000 1/4" PUSH-IN UNION TEE 15 4005-030-199 AIR-TROL PUSHBTN ESCUTCHEON S/S 5 2169-000-000 1/4" O.D. LLDPE TUBING, BLUE 16 4005-031-199 AIR-TROL PUSHBUTTON 6 7012-055-000 FOAM PIPE INSULATION 17 2566-025-002 SIDE OUTLET PUSHBUTTON SUB-ASSY 7 7000-420-000 1/4 TURN SHUT-OFF VALVE 18 2566-022-000 ESCUTCHEON RETAINER 8 7013-210-001 "Y" STRAINER, BOTTLE FILLER 19 2566-001-000 AIR DIAPHRAGM
9 7014-290-005 PNEUMATIC VALVE MOUNTING ASSY 20 2566-055-199 DIAPHRAGM RETAINER SIDE OUTLET 10 0302-011-000 #6-32 UNC HEX NUT 21 1895-450-000 1/8" O.D. NYLON COMPRESSION NUT 11 1895-709-000 ELBOW, 1/4" PUSH-IN x 1/4" STEM 22 7013-119-000 NEOPERL LAMINAR NOZZLE
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF11 PARTS LIST BOTTLE FILLER PARTS BREAKDOWN
9
65
8
22
15
10
14
12
13
16
18
17
21
20
19
65
7
3
65
4
1
2
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 16 of 19
11
Revised: 12/11/18
Member of
Cooler Mounted Bottle Fillers
ITEM # PART NUMBER DESCRIPTION ITEM # PART NUMBER DESCRIPTION
1 CONTACT FACTORY HOUSING ASSEMBLY, BF11/12 11 7012-055-000 FOAM PIPE INSULATION
2 7014-257-000 BOTTOM TRIM, H202GO 12 7000-420-000 1/4 TURN SHUT-OFF VALVE
3 2563-381-001 SENSOR "A" ASSEMBLY 13 7013-210-001 "Y" STRAINER, BOTTLE FILLER
4 0110-012-000 #6 x 3/16" TRUSS HEAD SCREW 14 7014-293-001 SOLENOID/VALVE MOUNTING ASSY
5 0716-111-001 BOTTLE COUNTER WITH CONNECTORS 15 0302-011-000 #6-32 UNC HEX NUT
6 0110-011-000 #6 x 3/16" PAN HEAD SCREW 16 0710-731-001 POWER SUPPLY
7 7014-253-199 SPLASH GUARD 17 1895-709-000 ELBOW, 1/4" PUSH-IN x 1/4" STEM
8 0116-123-000 #10-32 x 1" BUTTON HEAD SCREW 18 7100-441-000 LOCKING GROMMET,1.188 DIA HOLE
9 1895-710-000 1/4" PUSH-IN UNION TEE 19 7013-119-000 NEOPERL LAMINAR NOZZLE
10 2169-000-000 1/4" O.D. LLDPE TUBING, BLUE
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF12 PARTS LIST BOTTLE FILLER PARTS BREAKDOWN
17
19
10
11
14
13
15
10
11
12
6
8
10
11
16
18
7
6
9
5
4
3
1
2
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 17 of 19
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
ITEM # PART NUMBER DESCRIPTION
1 2563-000-002 DIRECT ACTING ASSEMBLY 2 0116-012-000 #8-32 x 1-1/4" PHILLIPS ROUND HEAD 3 0331-003-000
#8 LOCKWASHERS
4 1895-450-000
1/8" PLASTIC COMPRESSION NUT
5 2563-000-001
DIRECT ACTING MOTOR ASSEMBLY
6 2563-008-000 PILOT ORIFICE PLATE SPRING 7 2563-019-001
PILOT ORIFICE PLATE ASSEMBLY
8 2563-010-001
WATER DIAPHRAM ASSEMBLY
9 2563-007-000
DIRECT ACTING COVER PLATE
10 2563-004-001
DIRECT ACTING DIAPHRAM ASSEMBLY
11 2563-003-000
ACTUATOR SPRING
12 2563-001-000
MOTOR HOUSING
13 0401-026-000
SEPERATOR CUP O-RING
14 2563-002-199
SEPERATOR CUP
15 2563-000-000
VALVE BODY
16 2800-108-001
1/4" INLET ADAPTER ASSEMBLY
17 2570-051-001
1/4" OD PLASTIC ELBOW ASSEMBLY
18 1895-461-000
1/4" OD NYLON NUT
19 0326-100-000
RETAINING CLIP
20 0124-010-000
#10 X 1/2" PHILLIPS TRUSS HEAD
21 7014-1293-199
BF11/12 VALVE MOUNTING BRACKET
ITEM # PART NUMBER DESCRIPTION
1 2570-140-001 9-12 VDC SOLENOID OP VALVE ASSY 2 6502-043-000 #8-32 UNC x 1/2" PHILLIPS SCREW 3 0331-003-000
#8 LOCKWASHERS
4 2570-061-000
SOLENOID BONNET
5 2563-010-001
WATER DIAPHRAGM ASSEMBLY
6 2570-027-000 VALVE BODY 7 2563-326-001
9VDC LATCHING SOLENOID ASSEMBLY
8 2800-108-001
1/4" INLET ADDAPTER
9 2570-051-001
1/4" OD PLASTIC ELBOW ASSEMBLY
10 1895-461-000
1/4" OD NYLON NUT
11 0326-100-000
RETAINING CLIP
12 0124-010-000
#10 X 1/2" PHILLIPS TRUSS HEAD
13 7014-1293-199
BF11/12 VALVE MOUNTING BRACKET
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF11 VALVE BREAK DOWN
2
3
4
9
10
1
11
5
12
19
15
13
14
6
7
8
20
17
16
18
21
BF12 VALVE BREAK DOWN
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 18 of 19
10
2
3
7
11
8
4
1
5
6
9
13
12
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
M A I L A D D R E S S
C I T Y O F I N D U S T R Y, C A 91 7 4 4 U . S . A .
P H Y S I C A L AD D R E S S
1 5 1 2 5 P R O C T O R AV E N U E
C I T Y O F I N D U S T R Y, C A 91 7 4 6 U . S . A .
T O L L F R E E 8 0 0 - 5 9 1 - 9 3 6 0 • L O C A L 6 2 6 - 3 3 6 - 4 5 6 1
FA X 6 2 6 - 8 5 5 - 4 8 9 4 • W E B w w w. m u r d o c k m f g . c o m
P. O . B O X 3 5 2 7
NOTES TO INSTALLER:
1. Please leave this documentation with the owner of the fixture when finished.
2. Please read this entire booklet before beginning the installation.
3. Check your installation for compliance with plumbing, electrical and other applicable codes.
LIMITED WARRANTY - UNITED STATES & CANADA
Murdock warrants that its products are free from defects in material or workmanship under normal use and service for a period of one year from date of install or for 18 months after the date of shipment from the factory, whichever comes first. The sealed refrigeration system is warranted for five years. Murdock’s liability under this warranty shall be discharged solely by replacement or repair of defective material, provided Murdock is notified in writing within one year from date of shipment, F.O.B. Industry, California.
This warranty does not cover installation or labor charges and does not apply to materials, which have been damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges caused by defects in the materials, or any delay in the repair or replacement thereof. This warranty is in lieu of all other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard or non-compliance with these instructions will constitute an abnormal use condition and void the warranty. Stainless steel must be protected on job site during construction and must be properly maintained after the water has been introduced into the water cooler or drinking fountain, or Mudock’s limited warranty is void.
LIMITED EXPORT WARRANTY - One year on parts only.
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 19 of 19
Member of
Revised: 12/11/18
Loading...