I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
DIMENSIONAL DRAWING
Prior to roughing in, consult with local, state, and federal codes for proper mounting height.
Note: Rough-Ins are the same for BF11 & BF12
1
3
"
8
[79]
1
18
"
2
[470]
14"
[356]
6"
[152]
1
19
8
[486]
2
"
5
12
"
8
[321]
General Notes:
1. All dimensions are in inches [MM]
Optional -BCD
Bottle Counter
and Filter
Status Display
3
10
[264]
15"
"
8
[381]
Existing Fixture
Existing Fixture
Existing Fixture
2. Ø1/4" Holes, 10 Places for Anchoring Hardware,
provided by others
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 2 of 19
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
PRIOR TO INSTALLATION:
1. Some options may slightly alter installation. To ensure proper installation, review the Manual thoroughly and verify
rough-ins before beginning any work. File this Manual with the owner or maintenance personnel upon completion
of installation.
2. Carefully remove all fixture components from packaging, preventing scratching or damage. Inspect fixture and all
parts for damage.
3. Provide rough-ins as shown on the roughing-in and dimensional drawing. (See rough-in details)
4. Water Supply Service Stop Valve, Water Connections and Electrical Connections to be supplied and installed by
others in accordance with local codes.
5. Fixture mounting requirements: Industry standard wall construction, adequate to support the fixture and wall
anchors (installer provided) sufficient to secure the fixture.
6. Fixture operates within water pressure range of 20 to 105 PSIG. Murdock will not warranty fixtures damaged
when connected to supply lines with flow pressure lower than 20 PSIG or higher than 105 PSIG.
7. Water Supply inlet is 1/4” OD Polyethylene (PE) Tube.
8. Per UPC 609.10-All building water supply systems in which quick-closing Valves are installed shall be provided
with devices to absorb the hammer caused by high pressure resulting from the quick-closing of the Valve. These
pressure-absorbing devices shall be approved mechanical devices. Water pressure-absorbing devices shall be
installed as close as possible to the quick-closing Valve.
9. Completely flush supply of all foreign debris before connecting to fixture. Bottle Filler is designed to provide
trouble free drinking water unaffected by fixture connection tubing and fittings and will not cause problems with
taste, odor, color or sediment.
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 3 of 19
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
PUSH-IN FITTING INSTALLATION
NOTE: FITTINGS AND TUBE SHOULD BE KEPT
CLEAN, BAGGED AND UNDAMAGED PRIOR TO
INSTALLATION.
TO CUT TUBE:
Cut to fit length of 1/4” PE Tubing and remove any
burrs or sharp edges. Ensure that the outside diameter
is free from score marks. Tube ends should be square.
INSERTING THE TUBE:
1. Firmly and fully insert the Tubing end into the Push-In
Fitting up to the Tube Stop located approximately 1/2”
deep.
2. Pull on the fitted Tubing to ensure it is secure. Tube
should not come free from the Fitting. Water test the
connection assembly prior to leaving the site to ensure
there are no leaks.
DISCONNECTING THE TUBE:
Prior to disconnecting the Tube from the Fitting, ensure
that the Water Line is depressurized. Push Collet Square
towards the Push-In Fitting Body and hold. While holding
the Collet in, pull on the PE Tubing to remove from the
Push-In Fitting.
O-RING
O-RING
COLLET
TUBE STOP
COLLET
COLLET
COLLET
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 4 of 19
COLLET
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF11/BF12 INSTALLATION INSTRUCTIONS
Install the newly obtained Water Cooler per the Installation Manual
1
provided with the unit. Do not install Access Panel at this time. Shut-off
water supply, then actuate Valve to relieve pressure. Place Screws and
Panel in secure location for further use in Manual.
4
2
3
1
1
Water Cooler Assembly
2
Access Panel
3
#8 x 3/8" Hex Washer Head Screw
4
Water Cooler Installation Manual
Remove Bottle Filler Assembly, Power Supply and Grommet from
2
packaging, careful to avoid damage to Fixture and Fixture Sub
Assemblies. Set Power Supply aside in a secure location.
1
1
Bottle Filler Assembly
2
Power Supply (Not provided with BF11)
3
Locking Grommet
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 5 of 19
2
3
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF11/BF12 INSTALLATION INSTRUCTIONS (CONTINUED)
Unfasten Screws that hold the Bottle Filler Housing to the Mounting
3
Panel. Place Bottle Filler Panel and Screws in a secure location.
3
2
3
1
1
Bottle Filler Housing
2
Mounting Panel
3
#10-32 x 1" Button Head Screw
2
Disconnect the Water Supply Insulation and Tubing from 1/4" Shut-Off
4
Valve that is located on the Mounting Panel.
2
3
1
Mounting Panel
2
Shut-Off Valve
3
1/4" OD Tubing & Insulation
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 6 of 19
3
1
Member of
Revised: 12/11/18
1
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF11/BF12 INSTALLATION INSTRUCTIONS (CONTINUED)
Connect the Bottle Filler Supply Tubing to the 1/4" Push-In Tee located
5
on the Evaporator. The Evaporator is located within the Water Cooler
Assembly. If fixture differs from layout, refer to page 12 for specific unit
connections.
6
5
6
5
3
1
7
3
4
1
Water Cooler Assembly
2
Evaporator
3
1/4" OD Tubing & Insulation
(Bottle Filler Supply Tube)
4
7
2
1/4" Push-In Tee
5
Water Supply Tubing
(To Pushbutton Valve Inlet)
6
Water Supply Tubing
(To Bubbler)
7
Supply Inlet
Center Mounting Panel on top of Deck to finished wall and Secure with
6
Anchoring Hardware, by others, for Ø1/4" Mounting Holes.
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
1
Page 7 of 19
14" TYP. (A)
(B)
(B)
(B)
(B)
2
15"
TYP.
(A)
3
4
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF11/BF12 INSTALLATION INSTRUCTIONS (CONTINUED)
Push Tubing with Insulation and Power Wires up through hole in Basin.
7
Install Grommet.
2
4
1
4
" - 5"
2
3
1
Water Cooler Deck
2
1/4" OD Tubing & Insulation
3
Grommet
4
Power to Bottle Filler
(Not required with BF11)
1
1
Water Cooler Deck
2
Mounting Plate
3
1/4" OD Tubing & Insulation
4
Shut-Off Valve
Connect Water Supply Tube to the 1/4" Shut-Off Valve that is located
8
on the Mounting Panel. Refer to page 4 for proper connection.
4
1
4
" - 5"
2
3
1
2
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 8 of 19
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF11/BF12 INSTALLATION INSTRUCTIONS (CONTINUED)
BF11 SERIES
With Mounting Panel secured, place Bottle Filler Housing on top of
9A
the Water Cooler and connect water supply line from Bottle Filler to
Pneumatic Valve Outlet. Connect 1/8" Air-Line to Pushbutton and
Pneumatic Valve Inlet.
3
1/4"
Min.
5
1
1
Bottle Filler Housing
2
Water Cooler Assembly
3
1/4" O.D. Polyethylene Supply Line
4
Pneumatic Valve
5
Mounting Panel
6
Valve Water Supply Outlet Elbow
7
Valve Air-Line Supply Inlet
8
1/8" O.D. Polyethylene Supply Line
9
Pushbutton
4
8
7
6
9
2
1/4"
Min.
8
!
IMPORTANT
FOR BF11 SERIES, FOLLOW STEP 9A
FOR BF12 SERIES, FOLLOW STEP 9B
BF12 SERIES
With Mounting Panel secured, place Bottle Filler Housing on top
9B
of the Water Cooler and connect water supply line from Bottle
Filler to Solenoid Valve Outlet.
3
1/4"
Min.
5
1
1
Bottle Filler Housing
2
Water Cooler Assembly
3
1/4" O.D. Polyethylene Supply Line
4
Solenoid Valve
5
Mounting Panel
6
Valve Water Supply Outlet Elbow
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
4
Page 9 of 19
6
2
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF11/BF12 INSTALLATION INSTRUCTIONS (CONTINUED)
BF12-BCD SERIES
10A
Connect Electrical wiring as shown in diagram. If unit does not have
-BCD Bottle Count Display, skip to step 10B.
3
1
1
-BCD Bottle Count Display
2
Sensor
3
Solenoid Valve
4
Power Supply
5
Black Wire - BCD
2
4
5
4
BF12 SERIES
Connect Electrical wiring as shown in diagram. If unit has -BCD
10B
Bottle Count Display, see step 10A before continuing.
2
3
1
Sensor
2
Solenoid Valve
3
Power Supply
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 10 of 19
1
3
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF11/BF12 INSTALLATION INSTRUCTIONS (CONTINUED)
Connect Power Supply, turn on water and check for leaks
11
throughout the system.
3
4
1
Bottle Filler Housing
2
Mounting Panel
3
#10-32 x 1" Button Head Screw
4
Housing Bottom Flange
5
Mounting Panel Flange
1
Mounting Panel
2
Water Cooler Assembly
5
1
2
With fixture tested, install Housing to Mounting Panel. Angle
12
Housing and engage Housing Bottom Flange to Mounting Panel
Flange and close unit. Secure with Screws from step 3.
3
Bottle Filler Housing
4
Power Supply
5
Solenoid Valve
3
4
2
2
1
Mount Water Cooler Access Panel to Water Cooler.
13
2
1
3
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 11 of 19
5
1
2
3
Water Cooler
Bottle Filler
Access Panel
1
2
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
ELECTRICAL INSTALLATION:
NOTE: PLUG-IN POWER IS A STANDARD FEATURE.
1A. Plug-In Operation: Plug Transformer provided into GFCI protected electrical service, used by the Bottle Filler.
2. Connect the Power Supply Wires to either the Sensor or -BCD Bottle Counter Display (if equipped).
START UP:
1. Air within the Bottle Filler System or the structure supply Piping will cause an irregular Spout outlet stream until
purged out by incoming water. Hold cup (or similar object) directly below Filler Spout is recommended when first
activating Bottle Filler to prevent excessive splashing. Activate Sensor until steady water stream is achieved.
OPERATING INSTRUCTIONS:
Position container to be filled directly in front of the Sensor and centered under the Filler Spout. Water flow starts
automatically. When the container is almost filled, remove container. The water will stop flowing.
Illuminated LCD Display counts bottles and has a Filter replacement alert function.
Bottle Counting Function
The software applies a flow volume of approximately 16.9 fl oz (volume in standard size plastic water bottle) to
each bottle counted. If the flow volume is less than 16.9 fl oz, there will be no count but the volume will
accumulate, so that part way through the next cycle the total bottle count will change.
-BCD Bottle Counter Display
with Illuminated Display
Fill Spout
Sensor
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 12 of 19
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF11/BF12 Water Supply Tubing Diagram
Install Tubing as shown below to add Bottle Filler to Fixture
Non-Refrigerated Unit
(Drinking Fountain)
Non-Pressurized Unit
(Water Cooler)
Pressurized Unit
(Water Cooler)
2 5
3
1
Water Supply Line, to Bubbler
2
Water Supply Line, to Bottle Filler
3
1/4" O.D. Push-In Tee
4
Water Supply Line, Inlet
5
Foam Insulation
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 13 of 19
Pressurized with Bottle Filler
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
FILTER REPLACEMENT FUNCTIONS:
NOTE: When the volume accumulates to Filter capacity, the “REPLACE FILTER SOON” alert will appear on
the display every time the Bottle Filler is activated.
Counter Modes
Located on the back of the display you will find the Reset/Mode button for the mode settings. The Reset/Mode
Selection Button is accessible by removing the Housing, then locate the large hole in the back of the Display
Mounting Bracket. Use your finger or nonconductive object to depress the Reset/Mode Selection Button.
CAUTION: DO NOT USE SHARP OR METAL OBJECTS
With this Reset/Mode Button, you are able to indicate whether or not the unit has a Filter or does not have a Filter.
The Reset/Mode Button is used to remove the “REPLACE FILTER” alert after the Filter has been replaced.
Systems With or Without Filter:
•To reset “REPLACE FILTER” message:
-Press and hold Button until “3” is displayed, then release.
•To change display to match Filter capacity:
-Press and hold Button until the display matches installed Filter type, then release.
“FILTER NONE”
“FILTER 1500”
“FILTER 3000”
RESET/MODE
BUTTON
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 14 of 19
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
TROUBLE-SHOOTING:
1. IF LIGHT WITHIN SENSOR DOES NOT FLASH ONCE WHEN USER IS WITHIN RANGE:
a. Verify 120VAC input & 9VDC output of Transformer.
b. Replace defective Transformer.
c. Sensor in “Security Mode” after 20 seconds of constant detection. Remove source of detection
and wait 30 seconds before checking.
d. Sensor is picking up a highly reflective surface. Eliminate cause of reflection and wait 30 seconds
before checking.
e. Replace defective sensor.
2. IF LIGHT WITHIN SENSOR LENS FLASHES ONCE WHEN THE USER IS WITHIN RANGE:
a. Repair bad connection from Sensor to Solenoid.
b. There is debris or scale in the Solenoid assembly. Remove Solenoid, pull out Plunger and Spring.
Clean with scale remover solution.
c. There is debris or scale in center or two holes in convolution of the water diaphragm. Remove and
clean.
3. RESTRICTED OR NO WATER FLOW
a. Ensure Water Supply service stop valve is fully open.
b. Verify minimum 20 PSIG supply line flow pressure.
c. Check for twist or kinks in Spout Tubing.
d. Check the water inlet “Y’’ Strainer. Sediment from the main supply can get trapped in the Screen
along with installation materials such as pipe dope and flux. The Screen should be cleaned and
checked on a regular basis and replace if needed.
e. Flow Control in spout clogged, remove & clean.
f. The Water Cooler may also develop a freezing condition in which the water will become frozen inside
the Evaporator coil. This indicates a refrigeration problem or Thermostat failure in which case the
Water Cooler needs to be checked by a qualified technician.
g. No power to Transformer connections loose or wires cut.
CLEANING & MAINTENANCE GUIDE:
1. To remove water spots or rust spots, stainless steel cleaner/polish on a cloth is recommended.
2. If there are stubborn spots or if you wish to treat a scratch, synthetic abrasive general purpose pads
such as Scotch-Brite is recommended.
3. Apply stainless steel cleaner/polish to the synthetic abrasive pads and carefully rub the panel with
the grain.
4. Do NOT use harsh chemicals, abrasive or petroleum based cleaners. Use of these will
void the Murdock warranty. DO NOT use abrasives on powder coated units.
5. Stainless steel should be kept clean at all times. If a coating of stainless steel cleaner/
polish is maintained, stainless steel surfaces will retain their new, clean, polished appearance
indefinitely. Use clean mild soapy water for powder coated units.
6. Periodically remove Panels and clean out inline “Y’’ Strainer.
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
®
Page 15 of 19
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
ITEM #PART NUMBERDESCRIPTIONITEM # PART NUMBER DESCRIPTION
1CONTACT FACTORY HOUSING ASSEMBLY, BF11122150-003-199 1/8" OD LDPE TUBE, NATURAL, 3' LONG
27014-257-000BOTTOM TRIM, H202GO137100-441-000 LOCKING GROMMET,1.188 DIA HOLE
30116-123-000#10-32 x 1" BUTTON HEAD SCREW142566-160-001 (-PBH) SIDE OUTLET PUSHBUTTON
41895-710-0001/4" PUSH-IN UNION TEE154005-030-199 AIR-TROL PUSHBTN ESCUTCHEON S/S
52169-000-0001/4" O.D. LLDPE TUBING, BLUE164005-031-199 AIR-TROL PUSHBUTTON
67012-055-000FOAM PIPE INSULATION172566-025-002 SIDE OUTLET PUSHBUTTON SUB-ASSY
77000-420-0001/4 TURN SHUT-OFF VALVE182566-022-000 ESCUTCHEON RETAINER
87013-210-001"Y" STRAINER, BOTTLE FILLER192566-001-000 AIR DIAPHRAGM
32563-381-001SENSOR "A" ASSEMBLY137013-210-001"Y" STRAINER, BOTTLE FILLER
40110-012-000#6 x 3/16" TRUSS HEAD SCREW147014-293-001SOLENOID/VALVE MOUNTING ASSY
50716-111-001BOTTLE COUNTER WITH CONNECTORS150302-011-000#6-32 UNC HEX NUT
60110-011-000#6 x 3/16" PAN HEAD SCREW160710-731-001POWER SUPPLY
77014-253-199SPLASH GUARD171895-709-000ELBOW, 1/4" PUSH-IN x 1/4" STEM
80116-123-000#10-32 x 1" BUTTON HEAD SCREW187100-441-000LOCKING GROMMET,1.188 DIA HOLE
91895-710-0001/4" PUSH-IN UNION TEE197013-119-000NEOPERL LAMINAR NOZZLE
102169-000-0001/4" O.D. LLDPE TUBING, BLUE
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF12 PARTS LIST BOTTLE FILLER PARTS BREAKDOWN
17
19
10
11
14
13
15
10
11
12
6
8
10
11
16
18
7
6
9
5
4
3
1
2
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 17 of 19
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
ITEM # PART NUMBER DESCRIPTION
12563-000-002 DIRECT ACTING ASSEMBLY
20116-012-000 #8-32 x 1-1/4" PHILLIPS ROUND HEAD
30331-003-000
#8 LOCKWASHERS
41895-450-000
1/8" PLASTIC COMPRESSION NUT
52563-000-001
DIRECT ACTING MOTOR ASSEMBLY
62563-008-000 PILOT ORIFICE PLATE SPRING
72563-019-001
PILOT ORIFICE PLATE ASSEMBLY
82563-010-001
WATER DIAPHRAM ASSEMBLY
92563-007-000
DIRECT ACTING COVER PLATE
102563-004-001
DIRECT ACTING DIAPHRAM ASSEMBLY
112563-003-000
ACTUATOR SPRING
122563-001-000
MOTOR HOUSING
130401-026-000
SEPERATOR CUP O-RING
142563-002-199
SEPERATOR CUP
152563-000-000
VALVE BODY
162800-108-001
1/4" INLET ADAPTER ASSEMBLY
172570-051-001
1/4" OD PLASTIC ELBOW ASSEMBLY
181895-461-000
1/4" OD NYLON NUT
190326-100-000
RETAINING CLIP
200124-010-000
#10 X 1/2" PHILLIPS TRUSS HEAD
217014-1293-199
BF11/12 VALVE MOUNTING BRACKET
ITEM # PART NUMBER DESCRIPTION
12570-140-001 9-12 VDC SOLENOID OP VALVE ASSY
26502-043-000 #8-32 UNC x 1/2" PHILLIPS SCREW
30331-003-000
#8 LOCKWASHERS
42570-061-000
SOLENOID BONNET
52563-010-001
WATER DIAPHRAGM ASSEMBLY
62570-027-000 VALVE BODY
72563-326-001
9VDC LATCHING SOLENOID ASSEMBLY
82800-108-001
1/4" INLET ADDAPTER
92570-051-001
1/4" OD PLASTIC ELBOW ASSEMBLY
101895-461-000
1/4" OD NYLON NUT
110326-100-000
RETAINING CLIP
120124-010-000
#10 X 1/2" PHILLIPS TRUSS HEAD
137014-1293-199
BF11/12 VALVE MOUNTING BRACKET
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
BF11 VALVE BREAK DOWN
2
3
4
9
10
1
11
5
12
19
15
13
14
6
7
8
20
17
16
18
21
BF12 VALVE BREAK DOWN
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 18 of 19
10
2
3
7
11
8
4
1
5
6
9
13
12
Member of
Revised: 12/11/18
Cooler Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
M A I L A D D R E S S
C I T Y O F I N D U S T R Y, C A 91 7 4 4 U . S . A .
P H Y S I C A L AD D R E S S
1 5 1 2 5 P R O C T O R AV E N U E
C I T Y O F I N D U S T R Y, C A 91 7 4 6 U . S . A .
T O L L F R E E 8 0 0 - 5 9 1 - 9 3 6 0 • L O C A L 6 2 6 - 3 3 6 - 4 5 6 1
FA X 6 2 6 - 8 5 5 - 4 8 9 4 • W E B w w w. m u r d o c k m f g . c o m
P. O . B O X 3 5 2 7
NOTES TO INSTALLER:
1. Please leave this documentation with the owner of the fixture when finished.
2. Please read this entire booklet before beginning the installation.
3. Check your installation for compliance with plumbing, electrical and other applicable codes.
LIMITED WARRANTY - UNITED STATES & CANADA
Murdock warrants that its products are free from defects in material or workmanship under normal use and
service for a period of one year from date of install or for 18 months after the date of shipment from the factory,
whichever comes first. The sealed refrigeration system is warranted for five years. Murdock’s liability under this
warranty shall be discharged solely by replacement or repair of defective material, provided Murdock is notified in
writing within one year from date of shipment, F.O.B. Industry, California.
This warranty does not cover installation or labor charges and does not apply to materials, which have been
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this
warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges
caused by defects in the materials, or any delay in the repair or replacement thereof. This warranty is in lieu of all
other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard
or non-compliance with these instructions will constitute an abnormal use condition and void the warranty.
Stainless steel must be protected on job site during construction and must be properly maintained after the water
has been introduced into the water cooler or drinking fountain, or Mudock’s limited warranty is void.
LIMITED EXPORT WARRANTY - One year on parts only.
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-956-001
Page 19 of 19
Member of
Revised: 12/11/18
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.