![](/html/2c/2c47/2c4768ead45304b3cf80ff001959727eb56d74e8911ffdd8a6e9c59f99c37919/bg1.png)
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
DRINKING FOUNTAINS
A181CUSP Series
Barrier Free, Fully Recessed, ADA Fountain & Cuspidor
A181400S-CUSP / A181400F-CUSP / A18040000-CUSP / A181400S / A181400F
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:
1.800.591.9360
Technical Assistance Fax: 1.626.855.4894
NOTES TO INSTALLER:
1. Please leave this documentation with the owner of the fixture when finished.
2. Please read this entire booklet before beginning the installation.
3. Check your installation for compliance with plumbing, electrical and other applicable codes.
LIMITED WARRANTY - UNITED STATES & CANADA
Murdock warrants that its products are free from defects in material or workmanship under normal use and
service for a period of one year from date of original shipment or for 18 months after the date of shipment from the
factory, whichever comes first. Murdock’s liability under this warranty shall be discharged solely by replacement
or repair of defective material, provided Murdock is notified in writing within one year from date of shipment,
F.O.B. Industry, California.
This warranty does not cover installation or labor charges and does not apply to materials, which have been
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this
warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges
caused by defects in the materials, or any delay in the repair or replacement thereof. This warranty is in lieu of all
other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard
or non-compliance with these instructions will constitute an abnormal use condition and void the warranty.
Stainless steel must be protected on job site during construction and must be properly maintained after the water
has been introduced into the water cooler or drinking fountain, or Mudock’s limited warranty is void.
LIMITED EXPORT WARRANTY - One year on parts only.
Murdock assumes no responsibility for use of void or
suspended data. © Copyright Murdock, City of
Industry, CA Member of Morris Group International.
Please visit www.murdockmfg.com for most
current specifications.
Federal
7020-003-001 Date: 02/26/16
COMPLIES WITH
Public Law
111-380
(No Lead)
Test rating conditions are
compliant with ARI 1010.
Member of
MURDOCK
15125 Proctor Ave.
City of Industry, CA
91746 U.S.A.
Phone 800-591-9360
626-336-4561
Fax 626-855-4894
www.murdockmfg.com
![](/html/2c/2c47/2c4768ead45304b3cf80ff001959727eb56d74e8911ffdd8a6e9c59f99c37919/bg2.png)
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
DRINKING FOUNTAINS
NOTICE
A dielectric coupling must be used to connect the drinking fountains to the water supply. A nonmetallic
coupler is furnished with this drinking fountain to meet this requirement.
ROUGHING-IN AND DIMENSIONAL DRAWING
Prior to roughing consult with local, state, and federal codes for proper mounting height.
A181CUSP SERIES FULLY RECESSED ADA FOUNTAIN & CUSPIDOR
17"
WALL
OPENING
12"
WALL
OPENING
25
*33"
1
9
"
2
3
"
8
3
1
"
8
6"
15" MIN 15" MIN
GENERAL NOTES:
1. ALL DIMENSIONS ARE IN INCHES.
*2. DIMENSIONS SHOWN ARE FOR RECOMMENDED ADULT HEIGHT. ADJUST VERTICAL
DIMENSIONS AS NECESSARY TO COMPLY WITH FEDERAL, STATE & LOCAL CODES.
3. STOP VALVE NOT PROVIDED.
22" - 40"
ACCESS
PANEL
72" MIN
WALL
OPENING
6"
2"
(4) Ø
HOLES
1
" MTG
8
OPENING
3
30
4
27"
WALL
"
1-1/4" OD SLIP
JOINT WASTE
CONNECTION
17" MIN
WALL
OPENING
3
1
"
8
30"
NOTES:
Adjust vertical dimensions as required to comply with federal, state, and local codes.
Dimensions indicated are for ADA frontal approach installation. For Child ADA-ABA compliant parallel
approach installation, decrease height of installation for spout to be 30” maximum above finished floor.
Provide clear floor space as required. Adjust vertical dimensions as required to comply with federal,
state, and local codes.
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-003-001
Page 2 of 9
A181-CUSP
Member of
02/26/16
![](/html/2c/2c47/2c4768ead45304b3cf80ff001959727eb56d74e8911ffdd8a6e9c59f99c37919/bg3.png)
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
DRINKING FOUNTAINS
IMPORTANT:
1. Waste P-Trap and Water Supply Service Stop Valve to be supplied by other in accordance with local
codes.
2. Water supply is 3/8” copper tube (Fountain) & ½” male NPSM (Cuspidor). See Figure “E”. Waste is 11/4” OD female slip joint connection.
3. Completely flush supply lines of all foreign debris before connecting to fixture. Optional water filter is
available should there be problems from the water supply with taste, odor, color or sediment.
4. WARNING: Warranty is voided if installation is not made following current Acorn Engineering
Company installation instructions and if components are assembled to the fixture that are not
approved by Acorn Engineering Company .
5. Fixtures operates within water pressure range of 20 to 105 psig. Acorn Engineering Company will not
™
™
™
warranty fixtures damaged when connected to supply lines with flow pressure lower than 20 psig or
higher than 105 psig. A pressure regulator must be furnished by others on supply line if inlet pressure
is greater than 105 psig.
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-003-001
Page 3 of 9
A181-CUSP
Member of
02/26/16