Murdock A152 8-BF4, A152408S-BF4 Maintance Manual

I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
DRINKING FOUNTAINS
A152.8-BF4 Series
Rounded Box Chilled Barrier Free Wall Mount Bi-Level
Drinking Fountain w/ Sensor Activated Bottle Filler
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:
1.800.591.9360
Technical Assistance Fax: 1.626.855.4894
NOTES TO INSTALLER:
1. Please leave this documentation with the owner of the fixture when finished.
2. Please read this entire booklet before beginning the installation.
3. Check your installation for compliance with plumbing, electrical and other applicable codes.
LIMITED WARRANTY - UNITED STATES & CANADA
Murdock warrants that every cooler, bottle filling station, packaged water chiller, fountain and accessory to be free from defects in material and workmanship under normal use for one (1) year from date of install or eighteen (18) months after the date of shipment from the factory, whichever comes first.
Murdock warrants the compressor and hermetically sealed refrigeration system, including cooling coil assembly when part of the hermetically sealed refrigeration system, to be free from defects in material and workmanship under normal use for an additional four (4) years from the end of the one (1) year period described above.
This warranty does not cover installation or labor charges and does not apply to materials, which have been damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges caused by defects in the materials, or any delay in the repair or replacement thereof. This warranty is in lieu of all other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard or non-compliance with these instructions will constitute an abnormal use condition and void the warranty. Stainless steel must be protected on job site during construction and must be properly maintained after the water has been introduced into the water cooler or drinking fountain, or Murdock’s limited warranty is void.
LIMITED EXPORT WARRANTY - One year on parts only.
Murdock assumes no responsibility for use of void or suspended data. © Copyright Murdock, City of Industry, CA Member of Morris Group International. Please visit www.murdockmfg.com for most current specifications.
7020-949-001 Date: 07/18/18
COMPLIES WITH
Federal Public Law 111-380 (No Lead)
Test rating conditions are compliant with ARI 1010.
Member of
MURDOCK
15125 Proctor Ave. City of Industry, CA
91746 U.S.A.
Phone 800-591-9360
626-336-4561
Fax 626-855-4894
www.murdockmfg.com
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
This fixture is intended to dispense water that has been lowered in temperature, but otherwise remains unchanged by the materials in the drinking fountain. It is common for electrical equipment to be grounded to water lines either within a structure or away from it. Every attempt should be made to prevent this kind of grounding from generating electrical feedback into the drinking fountain creating electrolysis. Electrolysis will cause a metallic taste or cause water metal content to increase.
A dielectric coupling must be used to connect the drinking fountain to the water supply. A nonmetallic coupler is furnished with this water cooler to meet this requirement.
Prior to roughing in, consult with local, state, and federal codes for proper mounting height.
A152408S-BF4 Refrigerated Bi-Level Wall Mounted Drinking Fountain with Bottle Filler
32"
3
14
"
4
12"
DRINKING FOUNTAINS
IMPORTANT
NOTICE
DIMENSIONAL DRAWING
11
1
"
23"
2
3
8
"
8
3
1
8
Typ.
"
1
51
"
2
*33"
Finished
General Notes:
1. All dimensions are in inches *2. Dimensions shown are for recommended adult height. Adjust vertical dimensions as necessary to comply with federal, state, & local codes
3. Water line from chiller to fountain should be covered with sponge foam rubber or ice water type insulation of adequate thickness
NOTES: Dimensions shown for Adult ADA compliant installation. For Child ADA compliant parallel approach installation, decrease height of installation by 3 inches. Provide clear floor space as required. Adjust vertical dimensions as required to comply with federal, state, and local codes.
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-949-001 Page 2 of 23
Floor
A152.8-BF4
6"
Member of
Revised: 07/18/18
10
1
1
"
4
3
"
4
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
A152408S-BF4 Refrigeratd Reverse Bi-Level Wall Mounted Drinking Fountain with Bottle Filler
32"
3
14
"
4
1
11
"
23"
2
DRINKING FOUNTAINS
3
1
"
8
Typ.
6"
51
3
8
"
8
1
"
2
1
1
"
4
*33"
Finished
Floor
General Notes:
1. All dimensions are in inches *2. Dimensions shown are for recommended adult height. Adjust vertical dimensions as necessary to comply with federal, state, & local codes
3. Water line from chiller to fountain should be covered with sponge foam rubber or ice water type insulation of adequate thickness
NOTES: Dimensions shown for Adult ADA compliant installation. For Child ADA compliant parallel approach installation, decrease height of installation by 3 inches. Provide clear floor space as required. Adjust vertical dimensions as required to comply with federal, state, and local codes.
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-949-001 Page 3 of 32
A152.8-BF4
Member of
Revised: 07/18/18
10
3
"
4
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
A152408S-BF4 Refrigerated Wall Mounted Drinking Fountain Inlet & Outlet Rough-Ins
Note: There are no mounting changes to be made for -SO models.
DRINKING FOUNTAINS
**56
50
BLOCKOUT
1
"
4
1
30
"
4
BLOCKOUT
C
L
General Notes:
1. Dimension indicated with (**) is for 33" drinking fountain discharge height. if discharge height differs, adjust accordingly.
2. Standard Bi-Level rough-ins shown. For -RBL Reverse Bi-Level, -RBL Mounting Frame
2
1
3
"
1
1
"
2
8"
2
rough-ins opposite.
4
3
3
TYP.
"
8
1
5 8
**35"
"
**38"
2
**29
16"
1-1/4" O.D. Drinking Fountain Waste Outlet
1
3/8" NCT Drinking Fountain Supply Inlet
2
Alternate 3/8" NCT Bottle Filler Supply Inlets
3
NOTES: Dimensions shown for Adult ADA compliant installation. For Child ADA compliant parallel approach installation, decrease height of installation by 3 inches. Provide clear floor space as required. Adjust vertical dimensions as required to comply with federal, state, and local codes.
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-949-001 Page 4 of 23
A152.8-BF4
4
5
TYP.
2"
Alternate 1-1/4" O.D. Bottle Filler Waste Outlet
Electrical Service Rough
Member of
Revised: 07/18/18
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
Prior to roughing in, consult with local, state, and federal codes for proper mounting height.
Notes: 1-Standard Bi-Level rough-ins shown. For -RBL Reverse Bi-Level, -RBL
Mounting Frame rough-ins opposite
2-Chiller installation is always on the right-hand side of the shelf
6
3
DRINKING FOUNTAINS
DIMENSIONAL DRAWING
1
5
30
16"
1
"
4
4
ANCHORING CLIP DETAIL
Anchoring Clip Detail
Installation Instructions:
A-Provide 30-1/4" wide x 50-1/2" tall wall opening at
appropriate height. Provide structural support around inside of the opening for frame anchoring.
B-Carefully remove Bi-Level Mounting Frame 1 , chiller
mounting frame 2 , panel, anchoring clips 3 , and screws 4 from packaging, preventing damage.
C-Center both frames within wall opening with side, top
and bottom lips overlapping outside the opening and up against finished wall face. Set chiller shelve in place, aligning anchoring holes with holes in frame bottom. secure to wall through the sides, top and bottom using hardware 5 by others, ensuring 16" centerline dimensions left-to-right.
D-Install two anchoring clips 3 at bottom on outer sides
of chiller mounting frame 2 align holes in clips with holes 6 in frame and use sheet metal screws 4 provided. See anchoring clip detail.
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-949-001 Page 5 of 23
A152.8-BF4
1
50
"
2
1
56
4
Member of
Revised: 07/18/18
"
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
IMPORTANT:
1. Water Supply Service Stop Valve, Water Connections and Electrical Connections to be supplied by others in accordance with local codes.
2. Provide 4” minimum clear space in front of bottom trim panel and above in-wall chiller to allow for proper ventilation.
3. Waste is 1-1/4” Outer Diameter. Chiller water inlet is 3/8” Outer Diameter copper tube. Chiller water outlet is 3/8” Outer Diameter copper tube. Drinking Fountain water inlet is 3/8” Outer Diameter copper tube. Bottle Filler water inlet is 3/8” Outer Diameter copper tube. Water line by others from in-wall chiller to drinking fountain must have adequate insulation.
4. Completely flush supply lines of all foreign debris before connecting to fixture. Water cooler designed to not cause problems with taste, odor, color, or sediment. Optional Water Filter (WF1), is available should any of these problems arise from the water supply.
5. Do NOT solder tubes inserted into the chiller, bottle filler or the fountain strainer as damage to the o-rings on the push-in fittings may result.
6. All burrs must be removed from outside of cut tubes before inserting into strainer or other components.
7. Power supply must be identical in voltage, cycle and phase to that specified on the chiller data plate. Refer to submittal.
8. This unit must be grounded per the requirements of applicable electrical codes.
9. WARNING: Warranty is voided if installation is not made following current Murdock Mfg. installation instructions and if components are assembled to the fixture that are not approved by Murdock Mfg.
10. Fixture operates within water pressure range of 174 kPa (25 psig) to 724 kPa (105 psig). Murdock Mfg. will not warranty chiller damaged when connected to supply lines with flow pressure lower than 174 kPa (25 psig) or higher than 724 kPa (105 psig). A pressure regulator must be furnished by others on supply line if inlet pressure is greater than 724 kPa (105 psig).
11. Due to cold waste water, Murdock Mfg. recommends that waste piping supplied by installer be insulated appropriately to prevent excessive condensation.
12. Per UPC 609.10-All building water supply systems in which quick acting valves are installed shall be
provided with devices to absorb the hammer caused by high pressure resulting from the quick closing of the valve. These pressure-absorbing devices shall be approved mechanical devices. Water pressure-absorbing devices shall be installed as close as possible to the quick closing valve
DRINKING FOUNTAINS
PRIOR TO INSTALLATION:
1. Read all installation instructions carefully, before proceeding.
2. Carefully remove all fixture components from packaging, preventing scratching or damage. Inspect fixture and
all parts from damages and all parts that are bolted on.
3. Provide mounting surface, adequate to support the fixture and loads on the fixture.
4. Provide rough-ins as shown on the roughing-in and dimensional drawing, including water supply, drain pipe
and gravel drain well. (See rough-in details)
5. It is common for electrical equipment to be grounded to water lines either within a structure or away; otherwise,
remains unchanged by the materials in the water cooler. Every attempt should be made to prevent this kind of grounding from generating feedback into the water cooler creating electrolysis. Electrolysis will cause a metallic taste or cause water content to increase.
6. Electrical Receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth grounded per NEC
(National Electrical Code).
7. Completely flush water supply lines of all foreign debris, before connecting to the fixture.
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-949-001 Page 6 of 23
A152.8-BF4
Member of
Revised: 07/18/18
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
DRINKING FOUNTAIN INSTALLATION:
1. Insert mounting frame into the rough-in block out and secure using 1/4”-20 UNC mounting hardware (Provided
by Others).
2. Place the Chiller Unit onto the basepan of the frame assembly.
3. Hang upper trim panel on mounting frame. Note: The included 1” brackets do not get used with this installation
and the plastic spacers are typically not required and can be discarded.
4. Install the four threaded studs into the Wall Mounting Frame
5. Remove the drinking fountain top by taking out the drain screw and lifting at the front while pulling forward.
Disconnect bubbler tube. Set top aside in a safe place where it will not be damaged. Place the screw in a secure location where it will not be lost.
6. Slide Fixture over studs and secure with nuts and washers.
7. Assemble P-trap to drain adapter and then assemble to unit with Phillips head screws.
8. Make-up 1-1/4” outer diameter waste connection.
9. After thoroughly flushing the 3/8” outer diameter supply line, connect water supply to in-wall chiller and provide
connection from chiller to ‘the multi-line “Y” strainer assembly. From multi-line “Y” strainer assembly, connect to drinking fountain bubbler.
10. Place drain gasket on drain adapter. Reconnect bubbler tube. Reassemble top to unit by engaging back clip
and securing with screw.
BOTTLE FILLER INSTALLATION:
1. With drinking fountain installed, connect water supply line from multi-line “Y” strainer assembly to bottle filler.
2. Loosen slip nuts to orientate P-trap to desired direction then tighten slip nuts and make up 1-1/4” O.D. waste
connection.
3. FOR -BF4 ONLY Make up power connections to the ground, neutral & hot within the electrical box.
NOTE: BEFORE PERFORMING STEP 4, REFER TO ELECTRICAL INSTALLATION.
4. Test for leaks and proper operation, and then install the bottle filler panel using the water filler bracket and
secure the bottle filler by tightening the screws under the bottle filler.
DRINKING FOUNTAINS
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
7020-949-001 Page 7 of 32
A152.8-BF4