MURATA POWER SOLUTIONS MTU2S0524MC Datasheet

www.murata-ps.com
MTU2 Series
Isolated 2W Single & Dual Output SM DC/DC Converters
FEATURES
Patent Protected
UL 60950 Recognised
Footprint over pins 0.69cm
2
Single & dual isolated output
1kVDC Isolation “Hi Pot Test”
Efficiency up to 85% (Typ.)
MSL Level 1
Power density 3.403W/cm
3
3.3V, 5V, 12V & 24V Input
5V,12V & 24V single & dual outputs
Custom solutions available
Multi-layer ceramic capacitors
PRODUCT OVERVIEW
The MTU2 series is a new range of miniature sur­face mount, high performance 2W DC/DC convert­ers. With a footprint reduction of over 50% from the previous generations of 2W SMD DC/DC, the MTU2 series offers 2W of available output power over a wide temperature range. The MTU2 series is more efficient and offers improved regulation performance for applications where a wide output voltage variation can not be tolerated. The MTU2 series is pin compatible with the MTU2 series.
3
3
Order Code
1
Output
Voltage
Voltage
Nominal Input
VVmA
MTU2S0305MC 3.3 5 400 12.5 15 53 75 740 74 79 15 2650 MTU2S0505MC 5 5 400 9.5 12 47 65 480 78 82 17 2763 MTU2S0524MC 5 24 83 9 11 14 30 460 79 85 18 3060 MTU2S1205MC 12 5 400 7.5 10 40 60 200 72 80 20 2207 MTU2S2405MC 24 5 400 8 10 30 50 100 73 80 21 2314 MTU2D0505MC 5 ±5 ±200 10.5 13 30 55 480 77 82 19 2898 MTU2D0512MC 5 ±12 ±83 8.5 11 15 35 460 79 85 19 2697 MTU2D1212MC 12 ±12 ±83 6.5 8 15 35 190 77 83 24 2452
(Typ.)
Output Current
Load Regulation
% mVp-p
(Max)
Load Regulation
(Typ.)
(Max.)
Ripple & Noise
Ripple & Noise
Full Load
Efficiency (Min.)
Efficiency (Typ.)
Input Current at
mA % % pF kHrs
Isolation
Capacitance
2
MTTF
INPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Continuous operation, 3.3V input types 2.97 3.3 3.63
Voltage range
Reflected ripple current All variants 10 mA p-p
Continuous operation, 5V input types 4.5 5.0 5.5 Continuous operation, 12V input types 10.8 12.0 13.2 Continuous operation, 24V input types 21.6 24 26.4
V
ISOLATION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Isolation voltage Flash tested for 1 minute 1000 VDC Resistance Viso= 1000VDC 10 GΩ
OUTPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Rated power TA=-40°C to 85°C 2.0 W
Voltage set point accuracy
Line regulation High V
See tolerance envelope
IN to low VIN
MTU2S0305MC 1.0 1.3 All other variants 1.0 1.2
%/%
GENERAL CHARACTERISTICS
Parameter
Switching frequency
Conditions Min. Typ. Max.
MTU2D0505MC 50
All other variants 70
Units
kHz
The devices are suitable for all applications where high volume production is envisaged.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
ABSOLUTE MAXIMUM RATINGS
Input voltage VIN, MTU2S03 types 5.5V Input voltage V Input voltage V Input voltage V
1. If components are required in tape and reel format suffix order code with -R, e.g. MTU20505MC-R.
2. Calculated using MIL-HDBK-217 FN2 calculation model with nominal input voltage at full load.
3. See ripple & noise characterisation method. All specifications typical at T
IN, MTU2S05 types 7V IN, MTU2S12 types 15V IN, MTU2S24 types 28V
A=25°C, nominal input voltage and rated output current unless otherwise specified.
KDC_MTU2.C02 Page 1 of 9
MTU2 Series
Isolated 2W Single & Dual Output SM DC/DC Converters
TEMPERATURE CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Specification All output types -40 85 Storage -50 125
Case temperature rise above ambient
Cooling Free air convection
1 . Measured after 1 hour continuous operation at nominal VIN full load at the center of each PCB.
1
TECHNICAL NOTES
0305, 1205, 2405 30 45 All other variants
25 35
°C
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Volt­age’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions MTU2 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The MTU2 has been recognized by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the bar­rier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materi­als, construction and environment. The MTU2 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation test­ing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than func­tional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers.
SAFETY APPROVAL
The MTU2 series has been recognized by Underwriters Laboratory (UL) to UL 60950 for functional insulation to a maximum product PCB temperature of 120°C. Forced air cooling may be used to maintain this temperature requirement. File number E151252 applies.
The MTU2 Series of converters are not internally fused so to meet the requirements of UL 60950 an anti-surge input line fuse should always be used with ratings as defined below.
MTU2S03xxxC: 1.5A MTU2S05xxxC: 0.63A MTU2S12xxxC: 0.3A MTU2S24xxxC: 0.25A
All fuses should be UL approved and rated to at least the maximum allowable DC input voltage.
www.murata-ps.com/support
KDC_MTU2.C02 Page 2 of 9
MTU2 Series
Isolated 2W Single & Dual Output SM DC/DC Converters
RoHS COMPLIANCE INFORMATION
This series is compatible with RoHS soldering systems with a peak reflow solder temperature of 245ºC as per J-STD-020D.1.
The pin termination finish on this product series is Matte Tin over Nickel Preplate. The series is backward compatible with Sn/Pb soldering systems. The series has a Moisture Sensitivity Level (MSL) 1.
Samples of the product series were tested in accordance with the conditioning described for MSL level 1 in IPS/J-STD-020D.1. The product series passed electrical tests and visual inspection criteria.
For further information, please visit: www.murata-ps.com/rohs
TOLERANCE ENVELOPES
The voltage tolerance envelopes show typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to changes in output loading and set point accuracy.
MTU2D1212MC, MTU2S2405MC & MTU2D0512MC MTU2D0505MC, MTU2S0505MC & MTU2S1205MC
Output Voltage
13.7%
Output Voltage
8.9%
2.5%
5.7%
10
10.2%
4%
Output Voltage
25 10
Output Load Current (%)
5025 10
Output Load Current (%)
1.5%
-3.9%
75
100
MTU2S0305MC MTU2S0524MC
9.4%
4%
Output Voltage
25 10
Output Load Current (%)
25
Output Load Current (%)
1007550
2.2%
-7.6%
1.8%
-4.4%
7550
50
100
0.4%
-5.1%
10075
www.murata-ps.com/support
KDC_MTU2.C02 Page 3 of 9
MTU2 Series
Isolated 2W Single & Dual Output SM DC/DC Converters
APPLICATION NOTES
Minimum load
The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%.
Capacitive loading and start up
Typical start up times for this series, with a typical input voltage rise time of 2.2µs and output capacitance of 10µF, are shown in the table below. The product series will start into a capacitance of 47µF with an increased start time, however, the maximum recommended output capacitance is 10µF.
Start-up time
Typical Start-Up Wave Form
µs
MTU2S0305MC 225 MTU2S0505MC 165 MTU2S0524MC 3900 MTU2S1205MC 90 MTU2S2405MC 90 MTU2D0505MC 200 MTU2D0512MC 880 MTU2D1212MC
390
Ripple & Noise Characterisation Method
Ripple and noise measurements are performed with the following test configuration.
C1 1µF X7R m ultilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter
C2
10µF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less
than 100m at 100 kHz C3 100nF multilayer ceramic capacitor, general purpose R1 450 resistor, carbon film, ±1% tolerance R2 50 BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires Measured values are multiplied by 10 to obtain the specified values.
Differential Mode Noise Test Schematic
DC/DC Converter
SUPPLY
+
+
Input Output
-
-
C1 C2 C3 R1 T1
R2
OSCILLOSCOPE
Y INPUT
www.murata-ps.com/support
R LOAD
KDC_MTU2.C02 Page 4 of 9
APPLICATION NOTES CONTINUED
Output Ripple Reduction
By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max.
Component selection
Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended. The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC/DC converter.
Inductor: The rated current of the inductor should not be less than that of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF (Self Resonant Frequency) should be >20MHz.
L
Power
Source
DC
DC
MTU2 Series
Isolated 2W Single & Dual Output SM DC/DC Converters
MTU2S0305MC 4.7 82472C 11R472C 22 MTU2S0505MC 4.7 82472C 11R472C 22 MTU2S0524MC 47 82473C 11R473C 4.7 MTU2S1205MC 4.7 82472C 11R472C 22 MTU2S2405MC 4.7 82472C 11R472C 10 MTU2D0505MC 4.7 82472C 11R472C 22 MTU2D0512MC 47 82473C 11R473C 4.7 MTU2D1212MC 47 82473C 11R473C 4.7
C
Load
L, µH SMD Through Hole C, µF
Inductor Capacitor
www.murata-ps.com/support
KDC_MTU2.C02 Page 5 of 9
Isolated 2W Single & Dual Output SM DC/DC Converters
EFFICIENCY VS LOAD
3.3V INPUT 5V INPUT
90
80
70
60
50
40
Efficiency (%)
30
20
10
0
0 102030405060708090100
12V INPUT 24V INPUT
90
80
70
60
50
40
Efficiency (%)
30
20
10
0
0 102030405060708090100
Load (%)
MTU2S1205MC
MTU2D1212MC
Load (%)
MTU2 Series
90
80
70
60
50
40
Efficiency (%)
30
20
10
0
0 102030405060708090100
90
80
70
60
50
40
Efficiency (%)
30
20
10
0
0 102030405060708090100
Load (%)
Load (%)
MTU2D0505MC MTU2D0512MC MTU2S0505MC MTU2S0524MC
www.murata-ps.com/support
KDC_MTU2.C02 Page 6 of 9
TEMPERATURE DERATING
MTU2 Series
Isolated 2W Single & Dual Output SM DC/DC Converters
MTU2S0305MC MTU2S0505MC
100
95
90
85
80
Load (%)
75
70
65
60
55
45 50 55 60 65 70 75 80 85
Ambient Temperature OC
100
99
98
Load (%)
97
96
95
45 50 55 60 65 70 75 80 85
MTU2S0524MC MTU2S1205MC
100
95
90
Load (%)
85
80
45 50 55 60 65 70 75 80 85
Ambient Temperature OC
100
90
80
70
Load (%)
60
50
40
30
45 50 55 60 65 70 75 80 85
Ambient Temperature OC
Ambient Temperature OC
MTU2S2405MC MTU2D0505MC
100
95
90
85
80
75
70
65
Load (%)
60
55
50
45
40
35
45 50 55 60 65 70 75 80 85
Ambient Temperature OC
100
98
96
Load (%)
94
92
90
45 50 55 60 65 70 75 80 85
MTU2D0512MC MTU2D1212MC
100
80
60
Load (%)
40
20
0
45 50 55 60 65 70 75 80 85
Ambient Temperature OC
100
90
80
Load (%)
70
60
50
45 50 55 60 65 70 75 80 85
Ambient Temperature OC
Ambient Temperature OC
www.murata-ps.com/support
KDC_MTU2.C02 Page 7 of 9
PACKAGE SPECIFICATIONS
MTU2 Series
Isolated 2W Single & Dual Output SM DC/DC Converters
MECHANICAL DIMENSIONS PIN CONNECTIONS
2.54±0.10 [0.100±0.004]
6
4
5
Single Output Types
Pin Function
1+V 3-V 4 NC 5OV 6+V
1.56 [0.061]
1
8.20 [0.323]
3
5.08±0.10 [0.200±0.004]
8.40±0.45 [0.331±0.018]
Dual Output Types
Pin Function
1+V 3-V 4-V 5OV 6+V
8.50 MAX [0.335]
S
(0.35 [0.014])
0.60 [0.024]
All dimensions in mm (inches) ±0.05mm (0.002”). Controlling dimension is mm. All pins on a 2.54mm (0.100”) pitch. Weight: 0.79g, typ.
0.25 [0.010]
x5 PINS
0.10 [0.004]
1.80±0.20 [0
S
.071±0.008]
SEATING PLANE
1.80±0.20 [0.071±0.008]
IN
IN
OUT
IN
IN
OUT
OUT
RECOMMENDED FOOTPRINT DETAILS
6.50 (0.256)
1.00 (0.039)
2.54 (0.100)
2.54 (0.100)
2.60 (0.102)
TUBE OUTLINE DIMENSIONS
12.25 (0.482) MAX
0.75±0.15 (0.030±0.006)
12.25 (0.482) MAX
Unless otherwise stated all dimensions in mm±0.25mm (inches). Tube length: 520mm ±2.00
Tube Quantity: 60
www.murata-ps.com/support
KDC_MTU2.C02 Page 8 of 9
Isolated 2W Single & Dual Output SM DC/DC Converters
TAPE & REEL SPECIFICATIONS
REEL OUTLINE DIMENSIONS TAPE OUTLINE DIMENSIONS
330
(12.99) MAX
100
Ø
(3.94) MIN
+0.10 (0.059
-0.00
2.00±0.1 (0.079)
+0.004
-0.000
)
(AT HUB SECTION)
13.00±0.25
Ø
(0.51±0.009)
1.50
8.70±0.1 (0.343)
MTU2 Series
0.50±0.05 (0.020)
16.00±0.10 (0.630)
DIRECTION OF UNREELING
-0.00 (0.00)
2.00(+0.08)
24.40 (0.96)
REEL PACKAGING DETAILS
TRAILER SECTION
Product Orientation
Pin 1, located nearest to carrier drive sprocket.
Reel Quantity: 400 pcs.
160 (6.30) MIN
30.40 (1.20) MAX
MTU2S
0505
XWWYY
MTU2S
0505
XWWYY
GOODS
ENCLOSURE
SECTION
4.00±0.1 (0.157)
MTU2S
0505
XWWYY
1.75±0.1 (0.069)
11.50±0.1 (0.453)
24.00±0.30 (0.945±0.012)
CARRIER TAPE START
100 (3.94) MIN
8.50±0.1 (0.335)
9.00±0.1
LEADER SECTION
400 (15.75) MIN
Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
www.murata-ps.com/support
This product is subject to the following operating requirements
Life and Safety Critical Application Sales Policy:
and the Refer to:
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2015 Murata Power Solutions, Inc.
http://www.murata-ps.com/requirements/
KDC_MTU2.C02 Page 9 of 9