Murata Electronics North America 2100 Users Manual

Page 1
SN2100
Bluetooth Class 1 Module
And Datasheet
Version: 0.62
April 10, 2012
Note: SyChip, L.L.C. reserves the right to make changes in specifications at any time and without notice. The information furnished in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by SyChip for its use, nor any infringements of patents or other rights of third parties resulting from its use. No license is generated under any rights of SyChip or its supporters unless specifically agreed.
Page 2
Revision
Date
Author
Change Description
0.1
Jul-07-2011
Release the first datasheet.
0.5
Nov-15-2011
N. Nagayama
Update the block diagram / BT IC product number Update the SyChip Part Number
0.6
Jan-05-2012
Viet H.
Update the spec table
0.61
Jan-31-2012
Yong Fang
Added disclaimer
0.62
Apr-10-2012
JAG
Added packaging, labeling and regulatory information
Revision History
SyChip/Murata Confidential Page 2 of 27 SN2100 Datasheet V0.62
Page 3
Table of Contents
1 SYSTEM DESCRIPTIONS ......................................................................................................................... 5
1.1 APPLICATIONS .......................................................................................................................................... 5
1.2 MODULE SUMMARY .................................................................................................................................. 5
1.3 BLOCK DIAGRAM ...................................................................................................................................... 6
2 MECHANICAL SPECIFICATIONS ............................................................................................................ 7
2.1 MODULE DIMENSION ................................................................................................................................. 7
2.2 MODULE TOP AND SIDE VIEW ..................................................................................................................... 7
2.3 MODULE BOTTOM VIEW ............................................................................................................................. 8
2.4 DETAILED MECHANICAL DATA (TOP VIEW) ................................................................................................... 9
2.5 MODULE PIN-OUT ................................................................................................................................... 10
3 DC ELECTRICAL SPECIFICATIONS ..................................................................................................... 12
3.1 TYPICAL POWER CONSUMPTION .............................................................................................................. 12
3.2 DIGITAL IO SPECIFICATION ...................................................................................................................... 12
4 RF SPECIFICATIONS .............................................................................................................................. 13
4.1 BLUETOOTH SPECIFICATION .................................................................................................................... 13
4.2 RF CHARACTERISTICS (TX) .................................................................................................................... 13
4.3 RF CHARACTERISTICS (RX) .................................................................................................................... 15
5 ENVIRONMENTAL SPECIFICATIONS ................................................................................................... 16
5.1 ABSOLUTE MAXIMUM RATINGS ................................................................................................................. 16
5.2 OPERATION CONDITIONS ......................................................................................................................... 16
6 APPLICATION INFORMATION ............................................................................................................... 17
6.1 HOST PCB LAYOUT RECOMMENDATIONS ................................................................................................. 17
6.2 MODULE LOCATION ................................................................................................................................ 18
6.2.1 Location in x-y plane .................................................................................................................... 18
6.2.2 Location in z-plane ...................................................................................................................... 19
7 ASSEMBLY INFORMATION ................................................................................................................... 20
7.1 LEAD-FREE SOLDERING REFLOW PROFILE ................................................................................................ 20
8 PACKAGE INFORMATION ..................................................................................................................... 21
8.1 TAPE AND REEL SPECIFICATION ............................................................... ERROR! BOOKMARK NOT DEFINED.
8.2 MODULE MARKING .................................................................................. ERROR! BOOKMARK NOT DEFINED.
9 ORDERING INFORMATION .................................................................................................................... 22
10 ROHS DECLARATION ............................................................................................................................ 22
11 TECHNICAL SUPPORT CONTACT ........................................................................................................ 22
12 DISCLAIMER .................................................................................ERROR! BOOKMARK NOT DEFINED.
SyChip/Murata Confidential Page 3 of 27 SN2100 Datasheet V0.62
Page 4
LIST OF FIGURES
FIGURE 1 SN2100 MODULE BLOCK DIAGRAM .................................................................................................................. 6
FIGURE 2 MODULE TOP AND SIDE VIEW ............................................................................................................................ 7
FIGURE 3 MODULE BOTTOM VIEW ..................................................................................................................................... 8
FIGURE 4 DETAILED MECHANICAL DATA (TOP VIEW) ......................................................................................................... 9
FIGURE 5 RECOMMENDED HOST CIRCUIT BOARD DESIGN UNDERNEATH THE MODULE ................................................ 17
FIGURE 6 RECOMMENDED LOCATIONS IN XY-PLANE ....................................................................................................... 18
FIGURE 7 LOCATIONS NOT RECOMMENDED IN XY-PLANE ............................................................................................... 18
FIGURE 8 RECOMMENDED LOCATIONS IN Z-PLANE .......................................................................................................... 19
FIGURE 9 LOCATIONS NOT RECOMMENDED IN XY-PLANE ............................................................................................... 19
FIGURE 10 REFLOW PROFILE PATTERN .......................................................................................................................... 20
FIGURE 11 CARRIER TAPE DIMENSIONS .......................................................................................................................... 21
FIGURE 12 MODULE MARKING DETAIL ............................................................................................................................. 21
LIST OF TABLES
TABLE 1 MODULE CONNECTOR SIGNAL DESCRIPTION .................................................................................................... 10
TABLE 2 TYPICAL POWER CONSUMPTION ........................................................................................................................ 12
TABLE 3 DIGITAL IO SPECIFICATION ................................................................................................................................ 12
TABLE 4 RF SPECIFICATIONS ........................................................................................................................................... 13
TABLE 5 RF SPECIFICATIONS ........................................................................................................................................... 15
TABLE 6 ABSOLUTE MAXIMUM RATING ............................................................................................................................ 16
TABLE 7 RECOMMENDED OPERATING CONDITIONS ........................................................................................................ 16
TABLE 8 REFLOW PROFILE RECOMMENDATION .............................................................................................................. 20
TABLE 9 ORDERING INFORMATION ................................................................................................................................ ... 22
SyChip/Murata Confidential Page 4 of 27 SN2100 Datasheet V0.62
Page 5
System Descriptions
1.1 Applications
SN2100 is a complete industrial grade high power (class 1) Bluetooth® module with on­board antenna for M2M application. It integrates Bluetooth® IC, PA, RF front end, TCXO and chip antenna into a small LGA form factor and can be simply dropped into the OEM’s design. The SN2100 offers total 110 dB link budget, which is significantly better than most of the Bluetooth® modules do in the market. This makes it a good fit for industrial control application that usually requires longer distance coverage. The module offers extended product life and industrial standard operating temperature range to fit the industrial usage. The SN2100 offers standard HCI interface to the host CPU.
1.2 Module Summary
Bluetooth V4.0 Power Grade: Class 1 Dimensions: 17.5mm x 16.0mm x 2.0 mm Supply voltage: 2.2V to 3.3V Antenna: on-module 32kHz clock circuit : on-module Host Interface : UART/PCM RoHS compliant MSL JEDEC level 3 FCC/IC certified; CE compliant
SyChip/Murata Confidential Page 5 of 27 SN2100 Datasheet V0.62
Page 6
1.3 Block Diagram
Figure 1 SN2100 Module Block Diagram
SyChip/Murata Confidential Page 6 of 27 SN2100 Datasheet V0.62
Page 7
Parameter
Typical
Unit
Dimension (LxWxH)
17.5 x 16.0 x 2.0
mm
Dimension tolerances (LxWxH)
+/- 0.2 mm
mm
2 Mechanical Specifications
2.1 Module Dimension
2.2 Module top and side view
SyChip/Murata Confidential Page 7 of 27 SN2100 Datasheet V0.62
UNIT : mm
Figure 2 Module Top and Side View
Page 8
2.3 Module bottom view
Figure 3 Module Bottom View
SyChip/Murata Confidential Page 8 of 27 SN2100 Datasheet V0.62
Page 9
2.4 Detailed mechanical data (top view)
Figure 4 Detailed Mechanical Data (top view)
SyChip/Murata Confidential Page 9 of 27 SN2100 Datasheet V0.62
Page 10
Pin #
Pin name
I/O
Description
1
GND
-
Ground
2
VIN I Module Power Supply
3
Reserved
O
Internal for debugging use only
4
HCI_CTS
I
HCI UART Clear-To-Send. Module is allowed to send data when HCI_CTS is low.
5
HCI_TX
O
HCI UART data transmit
6
HCI_RTS
O
HCI UART Request-To-Send Host is allowed to send data when RTS is low.
7
HCI_RX
I
HCI UART data receive
8
nRESET
I
Shutdown input (Active Low)
9
GND
-
Ground
10
AUD_IN
I
PCM Data Input
11
AUD_OUT
O
PCM Data Output
12
AUD_CLK
I/O
PCM Clock
13
AUD_SYNC
I/O
PCM Frame Sync
14
GND
-
Ground
15
GND
-
Ground
16
GND
-
Ground
17
GND
-
Ground
18
GND
-
Ground
19
GND
-
Ground
20
GND
-
Ground
21
GND
-
Ground
22
GND
-
Ground
23
GND
-
Ground
24
GND
-
Ground
25
GND
-
Ground
26
Reserved
-
Internal use only
27
GND
-
Ground
28
GND
-
Ground
2.5 Module Pin-out
Table 1 Module Connector Signal Description
SyChip/Murata Confidential Page 10 of 27 SN2100 Datasheet V0.62
Page 11
Pin #
Pin name
I/O
Description
29
GND
-
Ground
30
GND
-
Ground
31
GND
-
Ground
32
GND
-
Ground
SyChip/Murata Confidential Page 11 of 27 SN2100 Datasheet V0.62
Page 12
Item
Condition
Values
Units
Min
Typ
Max
Standby mode (after send script)
VIN = 3.0V, TEMP = 25°C
-
3.5
-
mA
DH1 Packet 50% Rx/Tx slot duty 1 cycle Average
VIN = 3.0V, TEMP = 25°C
-
60 - mA
DH5 Packet 50% Rx/Tx slot duty 1 cycle Average
VIN = 3.0V, TEMP = 25°C
-
87 - mA
TX maximum current
VIN = 3.0V, TEMP = 25°C
-
150 - mA
RX maximum current
VIN = 3.0V, TEMP = 25°C
-
50 - mA
Item
Condition
Symbol
Min
Max
UNIT
High Level Input Voltage
VIH
0.65 x VDD
VDD
V
Low Level Input Voltage
VIL
0
0.35 x VDD
V
High Level Output Voltage
At 2/4/8 mA
VOH
0.8 x VDD
VDD
V
At 0.1 mA
VDD – 0.2
VDD
V
Low Level output Voltage
At 2/4/8 mA
VOL
0
0.2 x VDD
V
At 0.1 mA
0
0.2
V
3 DC Electrical Specifications
3.1 Typical Power Consumption
Table 2 Typical Power Consumption
3.2 Digital IO Specification
VIN = 3.0V, TEMP = 25°C, unless otherwise stated
VDD : 1.8V
Table 3 Digital IO Specification
SyChip/Murata Confidential Page 12 of 27 SN2100 Datasheet V0.62
Page 13
Parameter
Contents
Bluetooth Specification
Ver.4.0
Channel Spacing
1 MHz
The number of channel
79
Power Class
1
Parameter
Min
Typ
Max
BT Spec
Units
Output Power
-
18 - 20
(1)
dBm
Operation Frequency range (RX/TX)
2402
-
2480
-
MHz
-20 dB bandwidth
-
0.928 - 1
MHz
Adjacent Channel Power
[M-N] = 2
-
-40 - <-20
dBm
[M-N] >= 3
-
-43 - <-40
dBm
Modulation Characteristics
Modulation delta f1 avg
-
159
-
140< <175
kHz
Modulation delta f2 max
-
136 - 115<
kHz
Modulation delta f2 avg/delta f1 avg
-
0.9 - 0.8<
-
Initial Carrier Frequency Tolerance
-
-2
-
-75< <75
kHz
Carrier Frequency Drift
1 slot
-25 2 -
-25< <25
kHz
3 slot
-40 1 -
-40< <40
kHz
5 slot
-40 1 -
-40< <40
kHz
Maximum drift rate
-20
0.5
-
-20< <20
kHz/50 us
Out of Band Spurious Emissions
30 – 1000 MHz (Operation Mode)
-
-50 - <-36
dBm
1000 – 12750 MHz (Operation Mode)
-
-52 - <-30
dBm
1800 – 1900 MHz (Operation Mode)
-
-54 - <-47
dBm
4 RF Specifications
4.1 Bluetooth Specification
4.2 RF Characteristics (TX)
VIN = 3.0V, TEMP = 25°C, at 50Ω terminal load connected to the RF connector
Table 4 RF Specifications
SyChip/Murata Confidential Page 13 of 27 SN2100 Datasheet V0.62
Page 14
5150 – 5300 MHz (Operation Mode)
-
-54 - <-47
dBm
SyChip/Murata Confidential Page 14 of 27 SN2100 Datasheet V0.62
Page 15
Parameter
Min
Typ
Max
BT Spec
Units
Sensitivity (BER <= 0.1%)
-
-92 - < -70
dBm
C/I Performance (BER <= 0.1%)
Co-channel ratio (-60 dBm input)
-
10 - < 11
dB
1MHz ratio (-60dBm input)
-
-7 - < 0
dB
2MHz ratio (-60dBm input)
-
-21 - < -30
dB
3MHz ratio (-67dBm input)
-
-44 - < -40
dB
Blocking Performance (BER <= 0.1%)
30MHz – 2000MHz
-5 - -
-10<
dBm
2000MHz – 2400MHz
-5 - -
-27<
dBm
2500MHz – 3000MHz
-5 - -
-27<
dBm
3000MHz – 12750MHz
-5 - -
-10<
dBm
Intermodulation Performance (BER <= 0.1%, -64 dBm input)
-
-36 - -39<
dBm
Maximum Input Level
-4 - -
-20<
dBm
4.3 RF Characteristics (RX)
VIN = 3.0V, TEMP = 25°C, at 50Ω terminal load connected to the RF connector
Table 5 RF Specifications
(1) It is EIRP.
SyChip/Murata Confidential Page 15 of 27 SN2100 Datasheet V0.62
Page 16
Symbol
Description
Min
Max
Units
Top
Operating temperature
-40
85
C
Tst
Storage temperature
-40
85
C
VIN
Power supply
-0.3
5.0
V
MSL
Moisture Sensitivity Level
3
RoHS
Restriction of Hazardous Substances
Compliant
Symbol
Parameter
Min
Typ
Max
Units
VIN
Power supply
2.2
3.0
3.3
V
Top
Operating temperature
-40
-
85
C
5 Environmental Specifications
5.1 Absolute maximum ratings
Table 6 Absolute Maximum Rating
5.2 Operation conditions
Table 7 Recommended Operating Conditions
SyChip/Murata Confidential Page 16 of 27 SN2100 Datasheet V0.62
Page 17
Zone 1
Zone 2
6 Application Information
6.1 Host PCB layout recommendations
The SN3020 module has an onboard antenna therefore it requires some special host PCB layout underneath the module such that the radio can achieve its best RF performance. Refer to Figure 5 for the requirements.
Figure 5 Recommended Host Circuit Board Design underneath the Module
Notes:
1. Due to the surface mount antenna on the module, the area in ‘Zone1’ on all layers of the customer circuit board should be free of any metal objects. Specifically, there should be no ground plane, traces, or metal shield case.
2. The area in ‘Zone2’ on the top layer of the customer circuit board should have ground only with no signal traces.
SyChip/Murata Confidential Page 17 of 27 SN2100 Datasheet V0.62
Page 18
Antenna Connector
Antenna
Shield Case
No GND in this area (See Fig.8)
6.2 Module Location
For optimum EIRP, customer is advised to use the recommended module location on their respective PCB.
6.2.1 Location in x-y plane
Figure 6 Recommended Locations in xy-plane
Figure 7 Locations Not Recommended in xy-plane
SyChip/Murata Confidential Page 18 of 27 SN2100 Datasheet V0.62
Page 19
Antenna Connector
Antenna
Metal
Module
Mother Board
Metal
Metal
Metal
Metal
6.2.2 Location in z-plane
Figure 9 Locations Not Recommended in xy-plane
Figure 8 Recommended Locations in z-plane
SyChip/Murata Confidential Page 19 of 27 SN2100 Datasheet V0.62
Page 20
Ramp up rate
3oC/second max
Maximum time maintained above 217oC
120 seconds
Peak temperature
250oC
Maximum time within 5oC of peak temperature
20 seconds
Ramp down rate
6oC/second max
Reflow Profile
0
50
100
150
200
250
Time, seconds
Temperature, C
7 Assembly Information
7.1 Lead-free soldering reflow profile
The lead-free solder reflow profile is recommended in the table & graph below. The profile is used to attach the module to its host PCB.
The module is designed to withstand 2 reflows. Opposite side reflow is prohibited due to the module weight.
Table 8 Reflow Profile Recommendation
Figure 10 Reflow Profile Pattern
SyChip/Murata Confidential Page 20 of 27 SN2100 Datasheet V0.62
Page 21
8 Packaging and Marking Information
8.1 Carrier Tape Dimensions
Figure 11 Carrier Tape Dimensions
8.2 Module Marking Information
The following marking information may be printed on a permanent label affixed to the module shield or permanently laser written into the module shield itself. The 2D barcode is used for internal purposes. A pin 1 ID is stamped into the shield.
Figure 12 Module Marking Detail
SyChip/Murata Confidential Page 21 of 27 SN2100 Datasheet V0.62
Page 22
Product
SyChip Model
Number
SyChip Part
Number
Standard Order
Increment
Evaluation/Development Kit
SN2100EVK
88-0150-85
1 pc
Module in Tape and Reel
SN2100
88-0150-00
500 pcs
9 Ordering Information
Table 9 Ordering Information
10 RoHS Declaration
Given supplier declarations, this product does not contain substances that are banned by Directive 2002/95/EC or contains a maximum concentration of 0.1% by weight in homogeneous materials for
Lead and lead compounds Mercury and mercury compounds Chromium (VI) PBB (polybrominated biphenyl) PBDE (polybrominated biphenyl ether)
And a maximum concentration of 0.01% by weight in homogeneous materials for
Cadmium and cadmium compounds
11 Regulatory Information
SN2100 has obtained the certifications described below.
11.1 FCC Notice (USA)
This device using the integrated antenna has been tested to comply with FCC CFR Part
15. The device meets the requirements for modular transmitter approval as detailed in the FCC public notice DA00.1407. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
The FCC requires the OEM (original equipment manufacturer) to be notified that any
changes or modifications not expressly approved by SyChip, L.L.C may void the user’s
authority to operate the equipment. While an application of the SN2100 module in a product is not required to obtain a new FCC authorization for the module, this does not preclude the possibility that some other form of authorization or testing may be required for that end product.
SyChip/Murata Confidential Page 22 of 27 SN2100 Datasheet V0.62
Page 23
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: reorient or relocate the receiving antenna, increase the separation between the equipment and receiver, connect the equipment into an outlet on a circuit different from that to which the receiver is connected, or consult the dealer or an experienced radio/TV technician for help.
11.2 FCC Labeling Requirements
When integrating the SN2100 into a product, the FCC labeling requirements must be met by the OEM. This includes placing a clearly visible label on the outside of the finished product specifying the SN2100 FCC identifier (FCC ID:QPU2100) as well as the underlined FCC Notice above. The exterior label can use wording such as “Contains Transmitter
Module FCC ID:QPU2100” or “Contains FCC ID:QPU2100” although any similar wording
that expresses the same meaning may be used.
11.3 RF Exposure
This module has been certified for remote and base radio applications and is not intended to be operated within 20cm of the body. If the module will be used for portable applications, the device must undergo SAR testing.
The following statement must be included as a CAUTION statement in manuals for the products to alert users on FCC RF exposure compliance:
“WARNING: To satisfy FCC RF exposure requirements for mobile transmitting devices, a
separation distance of 20cm or more should be maintained between the antenna of this device and persons during operation. To ensure compliance, operations at closer distances than this are not recommended.”
11.4 IC Notice (Canada)
The term “IC” before the certification/registration number only signifies that the Industry Canada technical specifications were met.
Le terme “IC” devant le numéro de certification /d’enregistrement signifie seulement que les
spécifications techniques Industrie Canada ont été respectées.
SyChip/Murata Confidential Page 23 of 27 SN2100 Datasheet V0.62
Page 24
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Cet appareil est conforme avec Industrie Canada RSS standard exempts de licence (s). Son utilisation est soumise à Les deux conditions suivantes: (1) cet appareil ne peut pas provoquer d'interférences et (2) cet appareil doit accepter Toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif.
This device complies with Health Canada’s Safety Code 6 / IC RSS-210. The installer of
this device should ensure that RF radiation is not emitted in excess of the Health Canada’s
requirement. Information can be obtained at: http://www.hc-sc.gc.ca/ewh-
semt/pubs/radiation/radio_guide-lignes_direct-eng.php
Cet appareil est conforme avec Santé Canada Code de sécurité 6 / IC RSS-210. Le programme d'installation de cet appareil doit s'assurer que les rayonnements RF n'est pas émis au-delà de l'exigence de Santé Canada. Les informations peuvent être obtenues: http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct-eng.php
11.5 IC Labeling Requirements
The host device should be properly labeled to identify the module within the host device. The Industry Canada certification label of a module shall be clearly visible at all times when installed in the host device, otherwise the host device must be labeled to display the
Industry Canada certification number of the module, preceded by the words “Contains transmitter module”, or the word “Contains”, or similar wording expressing the same
meaning, as follows: Contains transmitter module IC:4523A-SN2100,
where 4523A-SN2100 is the module’s certification number.
11.6 CE Notice (Europe)
This device has been tested and certified for use in the European Union. If this device is used in a product, the OEM has responsibility to verify compliance of the
final product to the EU standards. A Declaration of Conformity must be issued and kept on file as described in Annex II of the Radio and Telecommunications Terminal Equipment Directive.
11.7 CE Labeling Requirements
The ‘CE’ mark must be placed on the OEM product per the labeling requirements of the Directive. Given that the operating frequency band is not harmonized by a few European
countries, the restriction or alert sign must be placed alongside the ‘CE’ mark as shown
below. The restriction is that, if the radio is operated outdoors in the 2450-2483.5 MHz
SyChip/Murata Confidential Page 24 of 27 SN2100 Datasheet V0.62
Page 25
band, the power must be limited to 10 mW instead of 100 mW. The OEM must account for this and the product must have the alert mark. It does not require country notifications, however.
12 Technical Support Contact
SyChip, LLC 2805 Dallas Parkway, Suite 400 Plano, TX 75093 USA Tel: (972) 202-8900 Fax: (972) 633-0327
Note: SyChip, LLC is an operating unit within Murata Wireless Solutions
13 Disclaimer
Please read this notice before using the SN2100 product.
1. Please note that the only warranty that SyChip LLC (“SyChip”) provides regarding the products is its conformance to the specifications provided herein. Accordingly, SyChip shall not be responsible for any defects in products or equipment incorporating such products, which are caused under the conditions other than those specified in this specification.
SYCHIP HEREBY DISCLAIMS ALL OTHER WARRANTIES REGARDING THE PRODUCTS, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, THAT THEY ARE DEFECT­FREE, OR AGAINST INFRINGEMENT OF INTELLECTUAL PROPERTY RIGHTS. YOU AGREE TO INDEMNIFY AND DEFEND SYCHIP AND ITS AFFILIATES AGAINST ALL CLAIMS, DAMAGES, COSTS AND EXPENSES THAT MAY BE INCURRED, INCLUDING WITHOUT LIMITATION, ATTORNEY FEES AND COSTS, DUE TO THE USE OF PRODUCTS.
2. The product is designed and manufactured for general applications, and not for any particular application, so testing and use of the product shall be conducted at your own risk and responsibility. Specifically, please observe the following:
SyChip/Murata Confidential Page 25 of 27 SN2100 Datasheet V0.62
Page 26
i) Please conduct validation and verification of the products in actual
condition of mounting and operating environment before commercial shipment of the equipment.
ii) Please pay attention to minimize any mechanical vibration or shock, not to
drop the product or a substrate that contains the product during transportation.
iii) Since the application of static electricity or overvoltage may cause a
defect in the product or deterioration of its reliability, caution must be taken against exposure to any static electricity generated by electrified items such as work benches, soldering irons, tools, carrying containers, etc.
iv) Caution shall be taken to avoid overstress to the product during and after
the soldering process.
v) Since the applied soldering method may deteriorate the reliability,
thorough evaluation is recommended.
vi) In case the product is to be used in equipment or electric circuit that
requires high safety or reliability function or performance, sufficient reliability evaluation checks for safety shall be performed before commercial shipment and moreover, due consideration to install a protective circuit is strongly recommended at customer's design stage. Please provide an appropriate fail-safe function on your product to prevent any damages that may be caused by the abnormal function or the failure of our product.
Notwithstanding the foregoing, the product shall not be used in any application listed below which requires especially high reliability for the prevention of such defect as may directly cause damage to the third party's life, body or property.
- Aircraft equipment
- Aerospace equipment
- Undersea equipment
- Power plant control equipment
- Medical equipment
- Transportation equipment (vehicles, trains, ships, etc.)
- Traffic signal equipment
- Disaster prevention / crime prevention equipment
- Application of similar complexity and/or reliability requirements to the applications listed in the above.
3. SyChip’s warranty as provided in Clause 1 above that the products comply with descriptions expressly specified in the specifications shall be effective for a period of six (6) months from the date of delivery. SyChip shall not be liable for any defects that occur in dry packed products that are installed more than six (6) months after shipment.
SyChip/Murata Confidential Page 26 of 27 SN2100 Datasheet V0.62
Page 27
SyChip’s liability under this warranty shall be limited to products that are returned during the warranty period to the address designated by SyChip and that are determined by SyChip not to conform to such warranty. If SyChip elects to repair or replace such products, SyChip shall have reasonable time to repair such products or provide replacements. Repaired products shall be warranted for the remainder of the original warranty period. Replaced products shall be warranted for a new full warranty period.
For avoidance of doubt, SyChip shall not be liable for any defects that are caused by neglect, misuse or mistreatment by an entity other than SyChip including improper installation or testing, or for any products that have been altered or modified in any way by an entity other than SyChip. Moreover, SyChip shall not be liable for any defects that result from your or third party’s design, specifications or instructions for such products.
4. Testing and other quality control techniques are used to the extent SyChip deems necessary. Unless mandated by government requirements, SyChip does not necessarily test all parameters of each product.
5. End of Life - Please note that we may discontinue the manufacture of products, due to reasons such as, but not limited to, end of supply of materials and/or components from our suppliers.
SyChip/Murata Confidential Page 27 of 27 SN2100 Datasheet V0.62
Loading...