Munters MK30D, MK45D, MK60D, MK90D User Manual

Originalinstructions
User´sManual
MK30D,MK45D,M
K60D,MK90D
Dehumidier
Coolingunit
190TEN-1071-C1304 ©MuntersEuropeAB2013
Importantuserinformation
Munters dehumidiers are intended to be used for the dehumidication of air. All other uses of the equipment, or use which is contrar y to the instructionsgiven in this manual, can cause personal injury and/or machine damage.
Warrantyandobl
Thewarrantyper equipment left o in writing. The including fre whichhave fai manufacture. has undergon the specica include pro warranty pe accordance specify th informati see the se
It is a condition of the warranty that the unit for the full warranty period is serviced and maintained bya qualied Munters engineer or Munters approvedengineer. Access to specic and calibrated test equipment is necessary. The service and maintenance must be documented for the warranty to be valid.
Always faults incor
e unit type and manufacturing number. This on is stamped on the unit identicationplate,
ction Marking.
contact Munters for service or repair. Operating
can occur if the unit is maintained insufciently or
rectly.
iod is valid from the date the
ur factory,unless otherwise advised
warranty is limited to a free exchange
e freight of the faulty unit or components,
led as a result of faulty quality or defects in
Munters guarantees that the unit supplied
e thorough testing to ensure that it meets
tions given here. All warranty claims must
of that the fault has occurred within the
riod and that the unit has been used in with the specications. All claims must
igations
Note!
The contents of this publication can be changed without prior notice. This publication contains information
which is protected by copyright laws. No part of this publication may be reproduced,stored in a system for information retrieval or be transmitted in any form, in any manner without Munters’ written consent. Please send any comments regarding the contents of this publication to:
Munters Europe AB
Technical Documentation
P O Box 1150
SE - 164 26 KISTASweden
e-mail: t-doc@munters.se
Safety
In this publication h azardous activities are indicated and preceded by the common hazard symbol.
WARNING!
isused inthispublicationto indicateapossibledangerthat couldlead topersonalinjury.Aninstruction isnormallygiven, followedby ashortexplanation,plus thepossibleeffectsif theinstruction isnotfoll owed.
CAUTION!
isused inthispublicationto indicateapossibledangerthat couldlead todamagetothemachineorother equipment and/orcause environmentaldamage. Aninstruction isnormallygiven,followedbyashortexplanation,plus thepossible environmentaleffectif theinstructionisnot followed.
NOTE! Usedtoaccentuatesu pplementaryinformation
thatis requiredforproblem-freeuseoroptimaluseofthe unit.
ii Importantuserinformation 190TEN-1071-C1304
Tableofcontents
Importantuserinfor
Intendeduseofequi
Warrantyandobligations .............
Note! ...................................
Safety ..................................
Tableofconten
1 Introduction ................................. 1
1.1 General ................................
1.2 UnpackingoftheunitsMK30D-
MK60D .................................
1.3 Unpackingof theunit (MK90D) .......
1.4 Marking ................................
1.5 Transportofthedehumidier .........
1.6 Stacking ................................
1.7 Operationprinciple ....................
1.8 Mainc
1.9 Watertank (MK30D-MK60D) .........
1.10 Driptray(MK90D) .....................
2 Installation ................................... 6
2.1 Electrical connection ..................
2.2Co
2.3 Remotesignals .......................
3 Operation .................................... 8
3.1 Control panel ..........................
3.2 Switchingon/off .......................
3.3 Internalhygrostatoperation ..........
omponents .....................
nnectionof humidistat .............
mation ...............
pment ...........
ts ...........................
10
ii ii ii
ii ii
iii
1
1 1 2 3 3 3 4 4 5
6 7
7
8 9
3.4 Externalhygrostato
3.5 Hourcounter ...........................
3.6 Display texts ...........................
3.7 Textdisplayswhennotconnectedto
mains ...................................
3.8 Replacingthememory battery .......
3.9 Error messages .......................
3.9.1 MK30D-MK60D ................
3.9.2 MK90D .........................
4 MaintenanceandService ................. 17
4.1 Monthlypreventivemaintenance
(MK30D-MK60D) .....................
4.2 Monthlypreventivemaintenance
(MK90D) ...............................
4.3 Annualpreventivemaintenance
(MK30D-MK90D) .....................
5 Troubleshooting ........................... 19
6 TechnicalSpecication .................... 20
6.1 DimensionsMK30D-MK60D .........
6.2 DimensionsMK90D ..................
6.3 Tec
7 Wiring diagrams ............................ 22
7.1 MK30D-MK60D .......................
7.2 MK90D .................................
parepart lists ..............................
8S
.1MK30D-MK60D .......................
8
8.2 MK90D ................................
h
nical data .........................
peration .........
10
11
12
13 14 15
15 16
17
17
18
20 20 21
22 2 2 26 28
4 6
190TEN-1071-C1304 Table ofcontents iii
1Introduction
1.1 General
Dehumidier MKD-series
The Munters MKD-series dehumidi
to locations where d ehumidicati
ers are available in four (4) different sizes and they can easily be moved
on of air is required.
WARNING!
Itis the resp onsibilityoftheoperatortoreadandunderstandthisservice manualandotherinformatio n prov ided, andtousethecorrectoperatingprocedures.
Read the entire manual before the initial start-up of the dehumidier. Awareness of the correct operating
procedure for the machineand its safety devices is important, to avoid damage or injury.
1.2 UnpackingoftheunitsMK30D-MK60D
WARNING!
Ifthedehumidierha
least1hourbeforepu
Followthese steps to unwrap the unit and make it ready for use
1 Open the cardboard boxin the top
2 Tilt the box with the handle and wheels towards the oor
sbeenlaiddownduringtransport,itisimperativethatyouplaceitinuprightpositionforat
tintoservice!
3 Pull the handle of the dehumidier and wheel the dehumidier out of the boxstill lying down
4 Tilt the dehumidier to an upright position
5 Loosen the knobs, pull the handle up to the desired height and retighten the knobs
6 Removethe protective foil on the control panel
1.3 Unpacki
ngoftheunit(MK90D)
WARNING!
Ifthedehumidierhasbeenlaiddownduringtransport,itisimperativethatyouplaceitinuprightpositionforat least1hourbeforeputintoservice!
1Unwr
2Li
3C
ap and lift the boxfrom the dehumidier
ft the dehumidier clear of the pallet
onnect the drain outlet stub which is supplied with the dehumidier
1 Introduction 190TEN-1071-C1304
Dehumidier MKD-series
1.4 Marking
MK30D-MK60D: The identication plate is placed behind the bucket inside the dehumidier.
MK90D:The identication plate is placed at the side of the dehumidier
D
D
3-32
190TEN-1071-C1304 Introduction 2
1.5 Transportofthedehumidier
NOTE! Observelocalworkingenvironmentrulesasregardsheavylifting
Twopeopleoracranecanmovethedehumidifier. See the instructions below
2 people Hoist/crane
Lift as shown below Lifting using a c argo strap
Dehumidier MKD-series
The wheels are positioned such that the machine can be pulled upstairs without damage to the cabinet or stairs.
1.6 Stacking
Max. two dehumidiers should be stacked on top of eachother. Press the handle of the lower dehumidier
to the bottom before stacking. The handle then ts a notch on the upper dehumidier.
1.7 Operationprinciple
The following describes the air ow through the dehumidier:
1. A fan draws in humid air through a lter to the dehumidier
2. The air is cooled down and humidity/water drops are led down to the water tank
3. The air is reheated by the operation of the dehumidier (approx. increase in temperature is +5 °C)
3 Introduction 190TEN-1071-C1304
Dehumidier MKD-series
Due to the repeated air circulation thr
whereby achieving rapid but gentle d sensor is connected.
1.8 Maincomponents
ough the dehumidier, the air humidity is continuously reduced
rying. The dehumidier will operate continuously if not a humidity
1Handle
2 Supply air inlet with PPI lter behind the grill
3 Water tank (MK30D-MK60D)
4 Control panel
5 Powercable
6Dryairoutlet
7Wheels
1.9 Watertank(MK30D-MK60D)
Water is collected in the water tank. Alternatively, you can also setup the dehumidier for permanent drainage with the adapter for hose connection . When the water tank is full, the dehumidier shuts off
automatically. Operationof the unit is not possible while the water tank is removed.
190TEN-1071-C1304 Introduction 4
Dehumidier MKD-series
1.10 Driptray(MK90D)
The drip tray catches condensation and is tted with an outlet branch that has a 1/2" tapping (enclosed)
5 Introduction 190TEN-1071-C1304
Dehumidier MKD-series
2Installation
Place the dehumidier
in the middle of a room if possible to ensure good air circulation
where air can be sucked in freely through the lter and blownout on the opposite side
with a minimum distance on the supply air side from a wall of about 600 mm. The minimum distance on
the dry air side should be 3 m
away from any source of heat e.g. a radiator
In addition, ensure that windows and doors are closed in the room to be dehumidied.
2.1 Electricalconnection
The dehumi 10A fuse o
190TEN-1071-C1304 Installation 6
dier is complete with cable and plug and ready for connection to a 230V/50Hz socket with a
r a 16A circuit breaker.
Dehumidier MKD-series
2.2 Connectionofhumidistat
The connection socket for the humidistat is located at the power cable entry. The humidistat shall be mounted 1–1.5 m. above the oor and positioned so that it is not exposed directly to
dry air from the unit or incoming moist air from opening and closing doors. It may not be placed close to a heat source or so that it is exposed to direct sunlight. The humidistat shall be a single stage humidistat and connected so that the controlling circuit closes as relative humidity increases. The connecting cable shall be screened and have copper conductors with a minimum cross-section area of 2 x 0.75 mm2.
2.3 Remotesignals
If an external alarm or run signal is required use terminal 24 and 25 which are connected by an electronic relay. The run signal to be connected at terminal 22 and 23. If an error occurs there is no longer connection and the alarm will start. Max 24V DC and 1,5mA.
7 Installation 190TEN-1071-C1304
Dehumidier MKD-series
3 Operation
3.1 Controlpanel
All functions are controlled from the integrated control panel.
1Display
2 Function keys
3 Status indicators
1
2
4 Main switch
3
4
Main functions
Manual or auto operation (built-in adjustable hygrostat).
External hygrostat socket.
.Display of temperature, relative air humidity, hours and kWh consumption
Hour counter and kWh consumed without 230V connection.
Adjustable service interval counter.
Operation described in the user guide in this manual.
190TEN-1071-C1304 Operation 8