Munters MK200 Operating Manual

Operation Manual
Dehumidifier MK200
Valid from 15.10.2018
Table of content
1. Important user information ................................................................................... 3
1.1 Intended use of equipment ................................................................................... 3
1.2 Warranty and obligations ...................................................................................... 3
1.2.1 Note ................................................................................................................... 3
1.2.2 Safety ................................................................................................................ 3
2. Installation ............................................................................................................ 4
2.1 Electrical connection ............................................................................................. 4
2.2 Operation .............................................................................................................. 5
2.3 Disposal ................................................................................................................ 5
3. Placement of dehumidifier .................................................................................... 5
3.1 Operation of dehumidifier ..................................................................................... 5
3.2 Automatic shut off and float switch ....................................................................... 6
3.3 Drainage of water ................................................................................................. 6
3.3.1 Using the hose: .................................................................................................. 6
3.3.2 Without hose, directly to a drain outlet: .............................................................. 6
3.4 Humidity Control ................................................................................................... 7
3.5 Air filter ................................................................................................................. 7
3.6 Automatic defrosting ............................................................................................. 7
3.7 Fan ....................................................................................................................... 7
4. Operation principle ............................................................................................... 8
4.1 Maintenance and cleaning .................................................................................... 8
4.2 Trouble shooting ................................................................................................... 9
5. Technical data ansd warranty ............................................................................ 10
5.1 Technical data .................................................................................................... 10
5.2 Warranty ......................................................................................................... 10
6. Wiring diagram ................................................................................................... 11
7. Explosion drawing .............................................................................................. 12
8. Spare parts list ................................................................................................... 13
9. CE Certificate ..................................................................................................... 14
1. Important user information
1.1 Intended use of equipment
Munters dehumidifiers are intended to be used for the dehumidification of air. All other uses of the equipment, or use which is contrary to the instructions given in this manual, can cause personal injury and/or machine damage.
1.2 Warranty and obligations
The warranty period is valid from the date the equipment left our factory, unless otherwise advised in writing. The warranty is limited to a free exchange including free freight to delivery address of the faulty unit or components, which have failed as a result of faulty quality or defects in manufacture. Munters guarantees that the unit supplied has undergone thorough testing to ensure that it meets the specifications given here. All warranty claims must include proof that the fault has occurred within the warranty period and that the unit has been used in accordance with the specifications. All claims must specify the unit type and manufacturing number. This information is stamped on the unit identification plate, see the section Marking. It is a condition of the warranty that the unit for the full warranty period is serviced and maintained by a qualified Munters engineer or Munters approved engineer. Access to specific and calibrated test equipment is necessary. The service and maintenance must be documented for the warranty to be valid. Always contact Munters for service or repair. Operating faults can occur if the unit is maintained insufficiently or incorrectly.
1.2.1 Note
The contents of this publication can be changed without prior notice. This publication contains information which is protected by copyright laws. No part of this publication may be reproduced, stored in a system for information retrieval or be transmitted in any form, in any manner without Munters’ written consent.
1.2.2 Safety
In this publication hazardous activities are indicated and preceded by the common hazard symbol.
WARNING!
is used in this publication to indicate a possible danger that could lead to personal injury. An instruction is normally given, followed by a short explanation, plus the possible effects if the instruction is not followed.
CAUTION!
is used in this publication to indicate a possible danger that could lead to damage to the machine or other equipment and/or cause environmental damage. An instruction is normally given, followed by a short explanation, plus the possible environmental effect if the instruction is not followed.
2. Installation
Before the installation and use of the appliance, carefully read the supplied instructions. The manufacturer is not responsible if an incorrect installation and use causes injuries and damages. Always keep the instructions with the appliance for future reference.
WARNING!
Flammable material. This appliance contains R290/Propane a flammable refrigerant.
Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer. The appliance shall not be stored in a room with continously operating ignition sources (for example; open flames, an operating gas appliance or an operation electric heater). Do not pierce or burn. Be aware that refrigerants may not contain an odour. Do not use water spray and steam to clean the appliance. Clean the appliance with a moist soft cloth. Only use neutral detergents. Do not use abrasive products, abrasive cleaning pads, solvents or metal objects. If the supply cord is damaged, it must be replaced by the manufacturer, Munters Service or similarly qualified persons in order to avoid a hazard.
CAUTION!
Only a qualified person must install this appliance. Remove all the packaging. Do not install or use a damaged appliance.
The appliance shall be installed, operated and stored in a room with a floor area larger than 4m². Obey the installation instruction supplied with the appliance. Always be careful when you move the appliance because it is heavy. Always wear safety gloves. Make sure the air can circulate around the appliance. Wait at least 4 hours before connecting the appliance to the power supply. This is to allow the oil to flow back in the compressor. Do not install the appliance close to radiators or other heat sources. Do not install the appliance where there is direct sunlight.
2.1 Electrical connection
WARNING!
Risk of fire and electrical shock. The appliance must be connected to a grounded outlet.
Make sure that the electrical information on the rating plate agrees with the power supply. If not, contact an electrician. Always use a correctly installed shockproof socket and make sure that the power supply is sufficiently fused. Do not use multi-plug adapters and extension cables. Make sure not to cause damage to the electrical components (e.g. mains plug, mains cable). Contact the Munters Service or an electrician to change the electrical components. The mains cable must stay below the level of the mains plug. Connect the mains plug to the mains socket only at the end of the installation. Make sure that there is access to the mains plug after the installation. Do not pull the mains cable to disconnect the appliance. Always pull at the mains plug.
2.2 Operation
WARNING!
Risk of injury, burns, electrical shock or fire. Do not change the specification of this appliance.
Be careful not to cause damage to the refrigerant circuit. It contains propane (R290), a natural gas with a high level of environmental compatibility. This gas is flammable. If damage occurs to the refrigerant circuit, make sure that there are no flames and sources of ignition in the room. Ventilate the room. Do not put flammable products or items that are wet with flammable products near or on the appliance.
2.3 Disposal
WARNING!
Risk of injury. Disconnect the appliance from the mains supply. Cut off the mains cable and discard it.
The refrigerant circuit of this appliance is ozone-friendly. Contact your municipal authority for information on how to discard the appliance correctly. Do not cause damage to the part of the cooling unit that is near the heat exchanger.
3. Placement of dehumidifier
MK200 dehumidifiers are easy to move around, all you need to have is a power source for 220/240V, but bear in mind the following:
- The dehumidifier should not be placed near radiators or other heat sources or exposed to direct sunlight, as it will reduce performance.
- It is beneficial to use a radiator or heating fan to keep the temperature above +2˚C.
- The dehumidifier should stand at least 25cm from a wall or other obstruction, for maximum air flow.
- Ideal is to put it in the center of the room / area.
3.1 Operation of dehumidifier
If the dehumidifier is transported horizontally, oil may have run out of the compressor and into the closed piping system. In such a case, let the dehumidifier stand for a few hours before being used. It is very important that the oil runs back into the compressor, otherwise the dehumidifier may be seriously damaged.
1. Check that the water reservoir is correctly placed and the float moves freely in the reservoir.
2. Connect the dehumidifier to a grounded power source.
3. Select fan speed.
4. Set the desired humidity level by means of the humidity control. See the section on the humidity
control.