mundoclima ALL IN ONE Type Air-source Heat Pump Water Heater, RSJ-35/300RDN3-B Owner's Manual

Thank you very much for purchasing our product,
Before using your unit , please read this manual carefully and keep it for future reference.
INSTALLATION & OWNER’S MANUAL
ALL IN ONE Type Air-source Heat Pump Water Heater
WARNING
Please ask skilled service persons for reliable earthing connection
Your safety is the most important thing we concerned !
PARTS NAMES
NOTE
All the picture in this manual are for explanation purpose only. They may be slightly different from the heat pump water heaterr you purchased (depand on model).The actual shaped shall prevail.
Front Cover
Electronic Control Box
Compressor
Display
Cove r
Front Decorative Board
Cove r (Electric Heater)
T CO
Electric Heater
TOD
P T V alve
W ater Outlet
Rear Cover
Junction Box
Junction Box Cover
Top Cover
Air Inlet
Fan Assy
Evaporator
Filter
Air Outlet
Water Inlet
Anode Rod
Drain Pipe
Solar Sensor
Solar Water Inlet
Solar Water Outlet
1
Installation & Owner‘s Manual
CONTENTS PAGE
1. PRECAUTIONS
To prevent injury to the user or other people and property damage the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
WARNING
WARNING
CAUTION
Failure to observe a caution may result in injury or damage to the equipment.
Failure to observe a warning may result in death or serious Injury .
The water heating unit must be earthed effectively
.
A creepage breaker
must
be
installed near the power
supply
Do not tear off the labels on the units for the purpose of warning or reminding
The safety precautions listed here are divided into two categories. In either case, important safety instructions are listed to which
close
attention must be paid.
W ARNING
Ask the professional installer for installation of the air source heat pump water heating unitsimproper installation may result in water leakage, electric shock, or fire.
Ask the professional service person for the repair and maintenance. Improper repair and maintenance may result in water leakage, electric shock or fire.
In order to avoid electric shock,fire or injury,if any abnormality is detected,such as smell of fire,turn off the power supply and call your service agent for instructions.
Never use the wire and fuse with wrong rated current.. Use of wrong wire or fuse may cause the unit to break down or a fire.
Do not insert fingers, rods or other objects into the air inlet or outlet. When the fan is rotating at high speed, it will cause injury.
Never use a flammable spray such as hair spray, lacquer paint near the unit. It may cause a fire.
Never touch the air outlet or the horizontal blades while the swing flap is in operation. Fingers may become caught or the unit may break down.
Never put any objects into the air inlet or outlet. Objects touching the fan of high speed can be dangerous.
Do not dispose this product as unsorted municipal waste.Collection of such waste separately for special treatment is necessary.
The appliance shall be installed in accordance national wiring regulations.
The appliance should not be used by children without supervision.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
An all-pole disconnection device which has at least 3mm separation distance in all pole and a residual current device(RCD)with the rating of above 10mA shall be incorpo­rated in the fixed wiring according to the national rule.
DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact you local government for information regarding the collection systems available.
If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.
1
2
2
3
4
5
6
8
1 4
1
PRECAUTIONS......................................................................................
ACCESSORIES......................................................................................
INSTALLATION LOCATION.....................................................................
INSTALLATION .....................................................................................
PIPELINE CONNECTION .......................................................................
DUCT CONNECTION WAY.......................................................................
ELECTRIC CONNECTION.......................................................................
OPERATING INSTRUCTION...................................................................
RUNNING AND CAPABILITY...................................................................
MAINTENANCE......................................................................................
SPECIFICATIONS...................................................................................
2
Installation & Owner‘s Manual
CAUTION
The earth pole of terminal must be earthed,and the rated current should be more than 10A. Make sure that power supply terminal and power supply plug are dry enough and have a good connection. Method: Turn on power supply run the unit for half a hour then turn it off and check whether the power supply plug is hot or nor.If it’s hot (more than 50),please change it with a new and eligible one, or it may result in an electric shock or fire.
Do not use the air-source water heater for other purposes.
Before cleaning,be sure to stop the operation and turn the breaker off or pull out the power cord. Otherwise, an electric shock and injury may be caused.
The hot water probable need to mix with cold water too hot water (over 50) in the heating unit may could injury.
In order to avoid injury, do not remove the fan guard on the outdoor unit.
Do not operate the air-source water heater with a wet hand. An electric shock may be caused.
The installation height of power supply should be over 1.8m, if any water may spatter. And safe from water.
In the water inlet side, the One Way valve must be installed.
It’s normal if some water drops from the hole of PT valve during operation.Bit, if the water is in a great amount, call your service agent for instructions.
After a long term use, check the unit stand and fittings. If damaged, the unit may fall and result in injury.
Arrange the drain hose to ensure smooth drainpipe. Improper drainpipe may cause wetting of the building, furniture etc.
Do not touch the inner parts of the controller. Do not remove the front panel. Some parts inside are dangerous to touch, and a machine malfunction may be caused.
Do not turn off the power supply. System will stop or restart heating automatically. A continuous power supply for water heating is necessary, except service and maintenance.
Prevent water from flowing back
2. ACCESSORIES
T able . 2-1
1
1
Accessory Name
Qty.
Sharp
Purpose
Y -shaped Filter
Owner’s & Installation Manual
Installation and use instruction This manual
T o filtrate inlet water
1
One Way Valve
3. INSTALLATION LOCATION
Enough space is installation and maintenance shall be preserved.
The air inlet and outlet should be free from obstacles and strong wind.
The bearing surface should be flat able to bear weight of the unit and suitable for installing the unit without increasing noise or vibration.
The operation noise and air flow expelled shall not affect neighbors.
No flammable gas is leaked nearby.
It is convenient for piping and wiring.
If it is installed in indoor space,it might cause indoor temp declined and noise disturbance, Please take preventive measures for this.
If the unit need to be installed on a metal holder, make sure they are insulated well and in accordance with local standard.
CAUTION
Installing the equipment in any of the following places may lead to malfunction of the equipment (if it is inevitable, consult the supplier).
The site contains mineral oils such as cutting lubricant.
Seaside where the air contains much salt.
Hot spring area where corrosive gases exist, e.g., sulfide gas.
Factories where the power voltage fluctuates seriously.
Inside a car or cabin.
Drain condensate water
1
Adaptor
3
Installation & Owner‘s Manual
Place like kitchen where oil permeates.
Place where strong electromagnetic waves exist.
Place where flammable gases or materials exist.
Place where acid or alkali gases evaporate.
Other special environments.
Precautions before installation
Decide the correct way of conveying the equipment.
Decide the correct way of conveying the equipment.
If the unit has to be installed on a metal part of the building, electric insulation must be installed, and the installation must meet the relevant technical standards for electric devices.
Installation space Before installing the unit, reserve the space of maintenance shown in the following figure.
Fig.3-1
Fig.4-1
Display
Fig.3-2
WARNING
4. INSTALLATION
Ask your
supplier to install the air source heat pump water heating units. Incomplete installation performed by yourself may result in a water leakage, electric shock, or fire.
The place without direct sunlight and other heat supplies. If there’s no way to avoid these, please install a covering.
The unit must be securely fixed, or else, noise and shaking will be resulted.
Make sure that there’s no remora around the unit.
In the place where there is strong wind like seashore, fix the unit in the location protected from the wind.
Carry the unit onto the site
In order to avoid scratch or deformation of the unit surface, apply guard boards to the contacting surface.
No contact of fingers and other things with the vanes.
Don’t incline the unit more than 45° in moving, and keep it vertical when installing.
This system is very heavy, it need to be carried by 2 or more persons, othewise might cause injury and damage.
Install the unit.
The circulating air for every unit should be more than 700m
3
/h.
Make sure there is enough Installation space. Outline dimensional drawing(see Fig.4-1,Fig.4-2)
Air outlet
Barrier
600mm
600mm
600mm
600mm
800mm
600mm
1920 mm
Air inlet
650 mm
Loading...