CONTENT
Read before operation ...................................................................................................
Safety precautions .........................................................................................................
Names of parts ...............................................................................................................
Operating instructions ....................................................................................................
Care and maintenance .................................................................................................
Troubleshooting ............................................................................................................
INSTALLATION MANUAL ............................................................................................
Safety precautions ........................................................................................................
Installation ....................................................................................................................
Indoor unit installation ..................................................................................................
Outdoor unit installation ...............................................................................................
REMOTE CONTROLLER ............................................................................................
3 4 5 7 8
11
13
15
16 17
18 21
24
IMPORTANT:
Thank you for selectiong super quality Air Conditiones. To ensure satisfactory operation for many ears to come, this manual should be read carefully before the installation and before using the air conditioner. After reading, store it a safe place. Please refer to the manual for questions on use or in the event that any irregularities occur.
This Air Conditioner should be used for hosehold use.
This unit must be installed by a professional according CE 795/2010.
WARNING:
The power supply must be SINGLE-PHASE (one phase (L) and one neutral (N)) with his grounded power (GND)
and his manual switch. Any breach of these specifications involve a breach of the warranty conditions provided by the manufacturer.
NOTE:
In line with the company's policy of continual product improvement, the aesthetic and dimensional characteristics, technical data and accessories of this appliance may be changed without notice.
2
OWNER´S MANUAL
Before using your air conditioner, please read this manual carefully and keep it for future reference..
INVERTER SPLIT-TYPE
ROOM AIR CONDITIONER
The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.
Read This Manual:
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find manyanswers to common problems in the chart of troubleshooting tips. If you review the chart of Troubleshooting Tips first, you may not need to call for service.
3
CAUTION
READ BEFORE OPERATION
Contact an authorised Contact the authinstaller for installation of this unit. This appliance is not intended for use by persons(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Young children should be supervised to ensure that they do not play with the
air conditioner. If the power cord is to be replaced, replacement work shall be performed by authorised personnel only. Installation work must be performed in accordance with the national wiring standards by authorised personnel only.
service technician for repair or maintenance of this unit.
When using this air conditioner in the European countries, the following informations must be followed:
DISPOSAL: Do not dispose
this product as unsorted municipal waste. Collection
of such waste separately for special treatment is necessary.
It is prohibited
to dispose of this appliance in domestic household waste. For disposal, there are several possibilities: A) The municipality has established collection systems, where electronic waste can
be disposed of at least free of charge to the user.
B) When buying a new product, the retailer will take back the old product at least
free of charge.
C) The manufacture will take back the old appliance for disposal at least free of
charge to the user.
D) As old products contain valuable resources, they can be sold to scrap metal
dealers. Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground-water and find their way into the food chain.
4
SAFETY PRECAUTIONS
To prevent
injury to the user or other people and property damage, the following instructions
must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
The seriousness is classified by the following indications.
WARNING
CAUTION
This symbol indicates
This symbol indicates
the possibility of death or serious injury.
the possibility of injury or damage to property.
Meanings of symbols used in this manual are as shown below.
Never do this.
Always do this.
WARNING
!
Connect
with the power
properly.
Otherwise, it may shock or fire due to heat generation.
Do not modify
cause electric
excess
power cord length or share the outlet with other appliances
It
may
cause
electric shock
or fire due to heat generation.
!
Always ensure eective earthing.
No earthing may
cause
electric shock.
!
Disconnect the power
if strange sounds, smell, or smoke comes from it.
It may cause fire and electric shock.
!
Use the correctly
rated
breaker or fuse.
Do not operate unit by switching on or o the power.
cause
It may due to heat generation.
Do not operate hands or in damp environment.
It may cause
Do not allow water to run into electric parts.
It may cause failure of machine or electric shock.
Do not drink from air conditioner.
It contains contaminants and could make you sick.
Do not use close to heating appliances.
or stop the
electric shock or fire
with wet
electric shock.
water drained
the power cord
Do not damage
or use an
unspecied power cord.
It may cause electric shock or fire.
Do not direct airow at room occupants only.
This could damage your health.
!
Always install circuit breaker and a dedicated power circuit.
No installation may cause fire and electric shock.
Do not open the unit during operation.
It may cause electric shock.
Do not disassemble or modify unit.
There is risk of fire or electric shock.
!
V
entilate
room
before operating air
It may cause fire and electric shock.
conditioner if there is a gas leakage from another appliance.
It may cause explosion, fire and, burns.
It may cause failure and electric shock.
Do not use the power cord near ammable gas or combustibles, such as gasoline, benzene, thinner, etc.
It may cause an explosion or fire.
5
When
the air filter is to be removed, do not touch the metal parts of the unit.
SAFETY PRECAUTIONS
CAUTION
Do not clean the air conditioner with water.
!
Ventilate the room well when used together with a stove, etc.
It may cause an injury.
!
When the unit is to be cleaned, switch off, and turn off the circuit breaker.
Do not clean unit when power is on as it may cause fire and electric shock, it may cause an injury.
!
Stop operation and close the window in storm or hurricane.
Operation with windows opened may cause wetting of indoor and soaking of household furniture.
Do not use strong detergent such as wax or thinner. Use a soft cloth for cleaning.
Appearance may be deteriorated due to change of product color or scratching of its surface.
Water may enter the unit and degrade the insulation. It may cause an electric shock.
Do not put a pet or house plant where it will be exposed to direct air flow.
This could injure the pet or plant.
Do not place obstacles around air-inlets or inside of air-outlet.
may cause
It
failure of
appliance or accident.
!
Ensure that the
installation bracket of the outdoor appliance is not damaged due to prolonged exposure.
If bracket is damaged, there is concern of damage due to falling of unit.
An oxygen shortage may occur.
Do not use for special purposes.
Do
not use
this air cond­itioner to preserve preci­sion devices, food, pets, plants, and art objects. It may cause deterioration of quality, etc.
!
Turn of
f the main power
switch when not sing
u
the unit for a long time.
may cause
It
failure of
product or fire.
!
Always insert the filters securely. Clean filter once every two weeks.
Operation without filters may
cause failure.
Do not place
heavy object on the power cord and take care so that the cord is not compressed.
There is danger of fire or electric shock.
!
Use caution when unpacking and installing. Sharp edges could cause injury.
6
If water enters
!
the unit, turn the unit off and disconnect the power , contact a qualified service technician.
IndoorUnit
NAMES OF PARTS
Air outlet
Outdoor Unit
Ai r inlet
Ai r inl et
7
1 2
4
Indoor Unit
3
5
6
9
1 F r on t panel
2 A ir filt er
3
Auto button
4 L o uv er
5 S ign al recep t or
6 S upp l y cord
7 R emote cont rolle r
8 D rain hose
9 R efri gerant gas/
Outdoor Un it
10 Cut -off val v e
11 Air outle t cover
liqui d pip e
11
Ai r outlet
8
10
NOTE:
All the pictures
in this manual are for explanation purpose only. Your air conditioner may be slightly different.
The actual shape shall prevail.
7
Operating temperature
OPERATING INSTRUCTIONS
Cooling
Heatin g
Manual
Manul operation can maintenance necessary.
operation
be used temporarily in case the remote controller is disable or
Outdoor
Indoor
Outdoor
Indoor
AUTO
47
18
<℃-12
30
NOTE: The unit must operating the manual control button. If the unit is operational, continue pressing the manual control button until the unit is off.
Open and lift
1
until it remains fixed with a clicking sound. One press of the manual control button will
2
lead to the forced AUTO operation.
a) As the unit is stopping, you can press the
"Auto button" to start operating.
b) As the unit is operating, you can press the
"Auto button" to stop operating.
3
Close the panel firmly to its original position.
be turned off before
the front panel up to an angle
8
Airow direction control
OPERATING INSTRUCTIONS
Adjust the air
flow direction properly otherwise, it might cause discomfort or cause uneven room temperatures. Adjust the horizontal louver using the remote controller. Adjust the vertical louver manually.
To set the vertical air ow(Up--Down) direction
Perform this function while the unit is in operation. Use the remote controller to adjust the air flow direction. The horizontal louver can be moved at
a range for each press, or swing up and down
automatically. Please refer to the REMOTE CONTROLLER OPERATION MANUAL for details.
,,
,,
To set the horizontal air ow direction (left - right)
Move the vertical
louver manually to adjust the air flow
in the direction you prefer.
IMPORTANT
:Beforeadjustingtheverticallouvers,the supply power must be disconnected. For some models, the vertical louver can be adjusted by using the remote controller. Please refer to the
,,
REMOTE CONTROLLER OPERATION MANUAL
for details.
,,
CAUTION
Do not operate the air flow direction set downward in cooling or dehumidifying mode. Otherwise, condensation may occur on the surface of the horizontal louver causing moisture to drop on to the floor or on furnishings. Do not move the horizontal louver manually unless it is necessary. Always use the remote controller.
When the air conditioner is started immediately after it was stopped, the horizontal louver might not move for approximately 10 seconds. Open angle of the horizontal louver should not be set too small, as COOLING or HEATING performance may be impaired due to too restricted air flow area. Do not operate unit with horizontal louver in closed position. When the air conditioner is connected to power (initial power), the horizontal louver may generate a sound for 10 seconds, this is a normal operation.
the air conditioner for long periods with
9
OPERATING INSTRUCTIONS
How
the air conditioner works
O operation
AUT
When you set the air conditioner in AUTO mode, it will
automatically select cooling, heating(cooling/heating
models only), or fan only operation depending on what
temperature you have selected and the room
temperature.
The air conditioner will control room temperature
automatically round the temperature point set by you.
If the AUTO mode is uncomfortable, you can select
desired conditions manually.
Optimal operation
To achieve optimal performance, please note the following: Adjust the air flow direction correctly so that it is not directed on people. Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessiv levels. Close doors and windows on COOL or HEAT modes, or performance may be reduced. Use TIMER ON button on the remote controller to select a time you want to start your air conditioner. Do not put any object near air inlet or air outlet, as the efficiency of the air conditioner may be reduced and the air conditioner may stop running. Clean the air filter periodically, otherwise cooling or heating performance may be reduced. Do not operate unit with horizontal louvre in closed position.
e temperature
Special functions
Auto-restart function (Optional)
In event of power interruption such as a blackout, the air conditioner stops once. But it restarts automatically and performs previous operation when the power supply is resumed.
10
Care and maintenance
CARE AND MANTENANCE
Cleaning the Grille,
Turn the
system off before cleaning. To clean, wipe with
Case and Remote Controller
a soft, dry cloth. Do not use bleach or abrasives.
NOTE: Supply power
must be disconnectd before
cleaning the indoor unit.
CAUTIONS
A cloth dampened with cold water may be used on the indoor unit if it is very dirty. Then wipe it with a dry cloth. Do not use a chemically treated cloth or duster to clean the unit. Do not use benzine, thinner, polishing powder, or similar solvents for cleaning. These may cause
the plastic surface to crack or deform. Never use water hotter than 40 C/104 F to clean
OO
the front panel, it could cause deformation of discoloration.
Cleaning the air lter
A clogged air filter reduces the cooling efficiency of this unit. Please clean the filter once every 2 weeks.
1. Lift the indoor unit panel up to an angle until it stops with a clicking sound.
2. Take hold of the handle of the air filter and lift it
up slightly to take it out from the filter holder, then pull it downwards.
3. Remove the AIR FILTER from the indoor unit.
Clean the AIR FILTER once two weeks. Clean the AIR FILTER with a vacuum cleaner or water, then dry it up in cool place.
Filter Tab
Air freshening filter
4. Remove the
Air Freshening Filter from its support
frame (on some models).
Clean the air freshening filter at least once a
month, and replace it every 4-5 months.
Clean it with vacuum cleaner, then dry it in cool
place.
5. Install the air freshening filter back into position.
6. Insert the upper portion of air filter back into the unit, taking care that the left and right edges line up correctly and place filter into position.