Efficiency can be up to 90%. Contrast with the AC fan motor, the power consumption of DC fan motor can
reduce up to 30%.
:
Air Flow:CFM
1.3 Convenient for installation
1.3.1 The ceiling type can be easily installed into a corner of the ceiling even if the ceiling is very narrow.
1.3.2 It is especially useful when installation of an air conditioner in the center of the ceiling is impossible
due to a structure such as one lighting.
1.3.3 The EXV is built-in the indoor unit, compact size, and convenient for the installation.
1.3.4 Reserved the socket on main control board for water pump and PCB can be customized if you need
water pump function.
1.4 Three air flow speed: high/middle/low, double air guides.
1.5 Two direction auto swing (vertical & horizontal) and wide
angle air flow
1.6 Low noise, creates quiet and comfortable environment.
1.6.1Adoption of the Fujikoki brand electronic expansion valve,
ensures precise flow control, as well as lower modulation
noise when EXV operating.
1.6.2 Smoother airflow with less turbulence. Owing to the
multiple-blade fan and the air guide design, the airflow is
getting smoother and more comfortable
Service manualMVD DC Indoor units
3
1.7 Wired control compatible
RM05/BG(T)E-A remote wireless controller which can set the indoor unit address is standard, and wired
controller is optional.
1.8 Auto restart
When the indoor unit is powered off, it will auto restart when powered on again after 3 minutes and
operate in the original state.
Notes: 1. Nominal cooling capacities are based on the following conditions: return air temperature: 27°CDB, 19°CWB,
outdoor temperature:35°CDB,equivalent ref. Piping: 8m(horizontal)
2. Nominal heating capacities are based on the following conditions: return air temperature: 20°CDB, outdoor temperature:
7°CDB,6°CWB,equivalent ref. Piping: 8m(horizontal)
Notes: 1. Nominal cooling capacities are based on the following conditions: return air temperature: 27°CDB, 19°CWB,
outdoor temperature:35°CDB,equivalent ref. Piping: 8m(horizontal)
2. Nominal heating capacities are based on the following conditions: return air temperature: 20°CDB, outdoor temperature:
7°CDB,6°CWB,equivalent ref. Piping: 8m(horizontal)
Model
A B C D E F G
36-71
990
660
203
505
506
907
200
80-90
1280
660
203
795
506
1195
200
112-140
1670
680
244
1070
450
1542
200
Model
I(Gas pipe)
J(Liquid pipe)
36-45
Ф12.7
Ф6.35
56-140
Ф15.9
Ф9.52
Service manualMVD DC Indoor units
6
3. Dimensions
3.1 Outline dimension
3.2 Refrigerant piping size
Air Outlet
Obstacle
Piping connection
Obstacle
Drop ceiling
Air Outlet
Service manualMVD DC Indoor units
7
4. Service Spaces
0 0mm
6
>
Keep more than 600mm clearance between the unit and left/right side wall.
As well 600mm and up between the front panel and wall. For well ventilation.
>20
Keep 20mm up between the rear and wall if standing installed. As well 20mm between top and the drop
ceiling if under ceiling installed
Note:
This indoor unit may be installed on ceilings up to 3.5 m in height. However, if the ceiling is higher
than 2.7m, the remote control with follow me function should be customized.
600mm