Multi-Tech Systems FR2201 User Manual

Router/Two-Port Frame Relay Access Device
MultiFRAD 200-Series
Model FR2201
User Guide
User Guide
8831 1500 Revision A
MultiFRAD II (Model FR2201)
This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-Tech Systems, Inc. All rights reserved.
Copyright © 1998, by Multi-Tech Systems, Inc.
Multi-Tech Systems, Inc. makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.
Record of Revisions
Revision Description
A Manual released; covers software revision 1.50. All pages at revision A. (10/26/98)
P ATENTS
This Product is covered by one or more of the following U.S. Patent Numbers:
5.355.365; 5.355.653; 5.452.289; 5.453.986
Trademark of Multi-Tech Systems, Inc. are MultiFRAD and the Multi-Tech logo. Windows is a registered trademark of Microsoft.
. Other Patents Pending.
TRADEMARK
Multi-Tech Systems, Inc.
2205 Woodale Drive
Mounds View , Minnesota 55112
(612) 785-3500 or (800) 328-9717
Fax 612-785-9874
Tech Support (800) 972-2439
Internet: http://www.multitech.com
5.301.274; 5.309.562
;
Contents
Chapter 1 - Introduction and Description
Introduction ................................................................................................................................................ 6
Preview of this Guide ................................................................................................................................. 7
Front Panel Description.............................................................................................................................. 8
Back Panel Description .............................................................................................................................. 9
Shunts ..................................................................................................................................................... 10
T echnical Specifications............................................................................................................................1 1
Chapter 2 - Installation
Introduction .............................................................................................................................................. 14
Unpacking your MultiFRAD ...................................................................................................................... 14
Cabling your MultiFRAD........................................................................................................................... 15
Chapter 3 - Software Loading and Configuration
Installing your Software ............................................................................................................................ 18
Chapter 4 - MultiFRAD Software
Introduction .............................................................................................................................................. 26
Before Y ou Begin............................................................................................................................... 26
MultiFRAD Configuration.......................................................................................................................... 28
Setup Menu.............................................................................................................................................. 28
IP Setup ................................................................................................................................................... 29
IPX Setup ................................................................................................................................................. 31
Spanning Tree Setup................................................................................................................................ 33
Statistics................................................................................................................................................... 34
IP Statistics ........................................................................................................................................ 35
IPX Port Statistics.............................................................................................................................. 36
STP (Spanning T ree) Port Statistics.................................................................................................. 36
SNMP Statistics ................................................................................................................................. 37
WAN Statistics................................................................................................................................... 38
Frame Relay Statistics....................................................................................................................... 38
WAN Port Setup....................................................................................................................................... 40
Point to Point Setup ................................................................................................................................. 41
Frame Relay Setup .................................................................................................................................. 42
Data Port Configuration............................................................................................................................ 46
Chapter 5 - Remote Configuration and Management
Introduction .............................................................................................................................................. 48
Modem-Based Remote Configuration Procedure..................................................................................... 48
LAN-Based Remote Configuration ........................................................................................................... 50
Windows Sockets Compliant TCP/IP Stack....................................................................................... 50
Telnet........................................................................................................................................................ 51
MultiFRAD Management ........................................................................................................... ............... 52
MultiFRAD Configuration.......................................................................................................................... 52
Remote User Database........................................................................................................... ................. 53
Web Browser Management...................................................................................................................... 54
iii
Chapter 6 - Warranty, Service and Tech Support
Introduction .............................................................................................................................................. 56
Limited Warranty ...................................................................................................................................... 56
On-line Warranty Registration............................................................................................................ 56
Tech Support ............................................................................................................................................ 57
Recording MultiFRAD Information ..................................................................................................... 57
Contacting Tech Support via E-mail ................................................................................................... 57
Service ..................................................................................................................................................... 58
The Multi-Tech BBS ................................................................................................................................. 59
To log on to the Multi-Tech BBS......................................................................................................... 59
To Download a file.............................................................................................................................. 59
About CompuServe.................................................................................................................................. 60
About the Internet..................................................................................................................................... 60
About the Multi-Tech Fax-Back Service ................................................................................................... 60
Appendixes
Appendix A - Cabling Diagrams................................................................................................................ 62
Appendix B - Regulatory Information ....................................................................................................... 65
Appendix C - Network Overview .............................................................................................................. 66
Glossary Index
iv
Router/Two-Port Frame Relay Access Device

Chapter 1 - Introduction and Description

MultiFRAD II User Guide

Introduction

Welcome to Multi-Tech's new MultiFRAD II™, model FR2201, a Router/ Two-Port Frame Relay
Access Device (FRAD) that encapsulates non-packetized data streams from serial and LAN devices
into frame relay frames and frames that data with header and trailer information prior to sending it to
the frame relay network. The MultiFRAD (Figure 1-1) enables non-frame relay devices to connect to
a common carrier frame relay network service or private frame relay network. This unit has a trunk
interface to a Frame Relay network, an Ethernet LAN connection for IP or IPX routing or bridging,
and two data channels that can be connected to non-frame-relay devices. On receiving a
communication over the frame relay network, the MultiFRAD strips away the frame relay control
information so the target device receives the data packaged in its original form.
Since frame relay networks use shared resources, they typically are more reliable and less
expensive per month than equivalent leased lines. Depending on the location and distances between
points, simple point-to-point networks can cost less per month than leased lines. The cost savings
are even greater when multiple leased lines are replaced with frame relay .
The trunk connection links to a synchronous Data Communications Equipment (DCE) device that
accesses the Frame Relay network. The Ethernet LAN connection handles IP or IPX routing and
Media Access Control (MAC) layer bridging for all other protocols on either a 10Base-T or AUI port
connection. The two data ports are for asynchronous or HDLC synchronous Data Terminal
Equipment (DTE) devices.
®
h
c
e
T
Systems
Figure 1-1. MultiFRAD II
6

Preview of this Guide

This User Guide describes the MultiFRAD and details how to install and configure it. The information contained in each chapter is as follows:
Chapter 1 - Introduction and Description
Chapter 1 describes the MultiFRAD and includes front panel descriptions, back panel connectors, and relevant technical specifications.
Chapter 2 - Installation
This chapter provides information on unpacking and cabling your MultiFRAD. Safety Warnings are detailed, followed by the installation procedure in which each cable is connected to the MultiFRAD and the unit is powered on.
Chapter 3 - Software Loading and Configuration
Chapter 3 details the software loading and configuration procedures. The MultiFRAD software is windows based; numerous configuration options are available and are described in this chapter.
Chapter 4 - MultiFRAD Software
Chapter 1 - Introduction and Description
Chapter 4 describes the MultiFRAD software from an applications approach, and includes examples of possible uses.
Chapter 5 - Remote Configuration and Management
Chapter 5 provides procedures for changing the configuration of a remote MultiFRAD. Remote configuration enables you to change the configuration of a unit by simply connecting a PC with communications software to a remote MultiFRAD that has communications software and a modem connected to the command port. You can then configure the unit. Chapter 5 also describes a typical Telnet Client application and a Web browser application.
Chapter 6 - Warranty, Service and Tech Support
Chapter 6 provides instructions on getting service for your MultiFRAD at the factory , a statement of the limited warranty , information about our user bulletin board service, and space for recording information about your MultiFRAD prior to calling Multi-Tech’s Technical Support personnel.
7
MultiFRAD II User Guide

Front Panel Description

The front panel has three groups of LEDs that provide the status of the LAN connection, trunk and
data channel activity , and general status of the MultiFRAD. The Ethernet LAN LEDs display LAN
activity; i.e., they show whether the MultiFRAD is connected to the LAN, transmitting or receiving
packets, and if a data collision is occurring. The trunk LEDs display the trunk status, whether a trunk
is ready to transmit or receive serial data, and if an external communications device with a V.35
interface is connected to the MultiFRAD. The data channel 1 and data channel 2 LEDs display the
status of the two data channels, including whether the data channel or the attached device is ready to
transmit or receive data and if the data channel is configured for a V.35 serial interface. The last
group of LEDs indicates whether the self test passed or failed and if the power On/Off switch on the
back of the MultiFRAD is switched On.
Figure 1-1. Front Panel
RCV Receive indicator blinks when packets are being received from the local area network.
LNK Link indicator lights indicating that the MultiFRAD is connected to the local area network.
XMT Transmit indicator blinks when packets are being transmitted to the local area network.
COL Collision indicator lights when a collision is in progress, that is, when two nodes are
transmitting packets at the same time.
RCV Receive indicator blinks when the trunk is receiving data.
CTS Clear To Send indicator lights when the trunk is ready to transmit data.
CD Carrier Detect indicator lights when the MultiFRAD detects a carrier signal.
XMT Transmit indicator blinks when the trunk is transmitting data.
RTS Request to Send indicator lights then the trunk is ready to receive data.
V35 The V35 indicator lights when the trunk is configured for a V.35 interface; i.e., the shunt for
the trunk is in the V.35 position.
Router/Two-Port Frame Relay Access Device
ETHERNET
TRUNK
DATA CHANNELS
XMT Transmit indicator blinks when the channel is transmitting data.
RTS Request to Send indicator lights when the attached device is ready to receive data from the
channel.
DTR Data T erminal Ready indicator lights when the attached device provides the DTR signal.
RCV Receive indicator blinks when the channel is receiving data.
CTS Clear To Send indicator lights when the channel is ready to transmit data.
V35 The V35 indicator lights when the channel is configured for a V.35 interface; i.e., the channel
shunt is in the V.35 position.
FAIL Fail indicator lights when a self test fails to complete as expected.
POWER The power indicator lights when the On/Off Switch is in the ON position.
8

Back Panel Description

All the cable connections to the MultiFRAD are made at the back panel. Four categories of cables are used on the MultiFRAD: Ethernet, Channels, Command Port, and Trunk (RS232/V.35). The back panel connectors are shown in Figure 1-2 and described in the following groups.
Chapter 1 - Introduction and Description
10BASE T
Ethernet 10Base-T Connector
The Ethernet 10Base-T connector is used to connect the MultiFRAD to a LAN using unshielded twisted cable. This connector is an RJ-45 jack.
Ethernet AUI Connector
The Ethernet AUI (Attachment Unit Interface) connector is used to connect the MultiFRAD to a LAN using thickwire Ethernet cable. This connector is a 15-pin D-shell female connector .
Channels 1 and 2 Connectors
The two Channel connectors are used to connect data devices to the MultiFRAD. A data device can be a synchronous device such as a multiplexer or an asynchronous device such as a PC. The data channels can be either RS232C or V.35 . If a V.35 connection is desired, then the internal shunt for that channel must be physically moved from its default RS232 position to the V.35 position. Back-to­back cables are supplied with the MultiFRAD to connect the RS232C data devices to the back panel DB25 male channel connectors.
Command Port Connector
The Command Port connector is used to configure the MultiFRAD using a PC with a serial port or terminal emulation. The Command Port connector has a DCE physical interface with a DB25 female connector.
ETHERNET
CHANNEL 2
AUI
CHANNEL 1
COMMAND PORT
TRUNK (RS232/V.35)
Figure 1-2. Back Panel
POWER
TRUNK (RS232/V.35) Connector
The RS232/V.35 trunk connector is used to connect the MultiFRAD to a Frame Relay Network. The trunk connection is to a synchronous communications device such as a modem, DSU, or ISDN. This connection can be either RS232C or V.35. If the connection is V.35, then the shunt for that link must be moved from the default RS232 position to the V.35 position. This connector is a DB25 male connector.
Power Connector
The Power connector is used to connect the external power supply to the MultiFRAD. The Power connector is a 6-pin circular DIN connector. A separate power cord connects the power supply to a live AC grounded outlet.
9
MultiFRAD II User Guide

Shunts

There are three shunts (Figure 1-3) on the printed circuit board for the trunk and the data channels.
The MultiFRAD has separate shunts for the trunk and both data channels. Both the default RS232
Shunt Position and the V.35 position for the Trunk are identified. The V.35 positions for the Channel
shunts are also shown. To change the position of a shunt, refer to the V .35 Shunt procedure in
Chapter 2.
Trunk RS232 Shunt Position
Trunk V.35 Shunt Position
Channel 1 V.35 Shunt Position
Channel 2 V.35 Shunt Position
Figure 1-3. Shunts
10

Technical Specifications

The MultiFRAD conforms to the following specifications:
Provides access to Frame Relay Networks for IP, IPX, bridged LAN traffic, Async and HDLC Sync devices
Trunk and data ports can be configured as either EIA-232 or V.35
Trunk speeds up to T1/E1, synchronous
Command Port - 19.2 Kbps, asynchronous
4 MB DRAM
1MB of Flash memory
Data Ports
Supports 2 data ports
Data port speeds from 300 bps to 115.2 Kbps asynchronous and 4800 bps to 128 Kbps synchronous
Asynchronous data format parameters: 5, 6, 7, 8 data bits; Even, Odd, None parity; 1,
1.5, 2 stop bits
Async Data port options: local echo, hardware or software flow control, pacing, Xon pass­thru, ENQ/ACK spoofing
Sync channel parameters: internal/external clocking, flag or mark idle, NRZ/NRZI encoding, interframe timer
Special APSM mode to allow Data port and LAN traffic muxing over a single PVC
Chapter 1 - Introduction and Description
Ethernet Port
Routing Protocols - IP and IPX and bridging all others
Ethernet Interface - 10Base-T (twisted pair) RJ-45 connector or 10Base5 (Thicknet) 15-pin D-shell female connector (AUI)
Special APSM mode to allow LAN traffic and Data port muxing over a single PVC
Command Port
Single 19.2K bps asynchronous Command Port with DB25 female connector.
Trunk Port
T1/E1 (1.544M/2.048 Mbps) sync link using DB25 male connector. Optional ITU-T V.35 interface using a V.35 adapter cable.
Supports over 900 concurrent PVCs. DLCI values from 16 to 1007
ANSI Annex D, Annex A, or LMI link management protocols
Electrical/Physical
Power Supply Input: 100 to 250V AC ~ 50 to 60 HZ, 0.9A
Power Supply Output: +5V DC @ 3.0A, +12V DC @ 0.5A, -12V DC @ 0.2A
Power Consumption: 10 Watts
Dimensions - 2.25" high x 9" wide x 12.875" deep
Weight - 4.5 pounds (1.7 kg)
Requirement
PC with one serial COM port to connect to the Command Port of the MultiFRAD for configuration
11
MultiFRAD II User Guide
12
Router/Two-Port Frame Relay Access Device

Chapter 2 - Installation

MultiFRAD II User Guide

Introduction

This chapter will guide you through the unpacking and installation of your MultiFRAD. The installation procedure, which is preceded by important safety warnings, provides step-by-step instructions on cabling and powering-on the MultiFRAD. Chapter 3 provides instructions on installing and configuring the MultiFRAD software.

Unpacking your MultiFRAD

Remove all items from the box. Your shipping box should contain the MultiFRAD, a power supply, various cables, software and manual disks, and a MultiFRAD Model FR2201 Quick Start Guide. Inspect all items (Figure 2-1) before proceeding with the installation. If any item appears to be damaged, do not power up the unit; contact Multi-Tech’s Technical Support personnel for advice (Refer to Chapter 6). If no damage is observed, configure the MultiFRAD using the information in the rest of this chapter.
®
h
c
e
T
Systems
MADE IN U.S.A
MADE IN U.S.A
Figure 2-1. Unpacking
14

Cabling your MultiFRAD

Cabling your MultiFRAD involves making the proper Power, Command Port, Ethernet, and Channel connections. Figure 2-2 shows the back panel connectors and the associated cable connections. Table 2-1 details the procedures for connecting the cables to your MultiFRAD.
T able 2-1. Cabling Procedure
Step Procedure
1 Connect one end of a (supplied) DB25 back-to-back cable to each of the data channel
connectors on the back of your MultiFRAD (labeled CHANNEL 1-2). See Figure 2-2. Connect the other end of each cable to a channel device.
NOTE: Both channels support the RS232/V.35 protocols, and either asynchronous or HDLC synchronous RS232 data equipment such as multiplexers.
Chapter 2 - Installation
Ethernet Connection
Back-to-Back Cables to Channel Devices
10BASE T
ETHERNET
CHANNEL 2
AUI
CHANNEL 1
COMMAND PORT
TRUNK (RS232/V.35)
POWER
Power Connection
T1 CSU/DSU or Comparable Link Device
Command Port Connection
Figure 2-2. Cable Connections
2 Connect one end of an DB25 (female) cable to the Trunk connector (Figure 2-2). Connect the
other cable end to your T1 CSU/DSU or compatible link device.
3 To make the network connection, connect an RJ-45 (UTP) cable to the 10 BASE-T Ethernet
connector or the male connector for a 10Base5 cable to the AUI Ethernet connector (shown in Figure 2-2). Connect the other end of the cable to your LAN.
4 Connect the MultiFRAD to your PC with a standard RS232 cable. Plug the male end of the
cable into the Command Port (Figure 2-2) and the other end into the PC’s serial port.
5 Connect one end of the power supply to a live AC outlet, then connect the other end to the
MultiFRAD as shown in Figure 2-2. The Power connector is a 7-pin circular DIN connector.
6 Apply power to the MultiFRAD by setting the Power switch (Figure 2-2) to the “1” (on)
position.
At this time your MultiFRAD is completely cabled. Proceed to the next section to install your software.
15
MultiFRAD II User Guide
16
Router/Two-Port Frame Relay Access Device

Chapter 3 - Software Loading and Configuration

MultiFRAD II User Guide

Installing your Software

The following procedure does not provide every screen or option used in the process of installing the MultiFRAD software. The assumption is that a technical person with a thorough knowledge of Windows and the software loading process is doing the installation. Additional information on the MultiFRAD software is provided in the User Guide supplied with your MultiFRAD II.
1. Run Windows on the PC that is connected to the Command Port.
2. Insert the MultiFRAD II disk 1 into the disk drive on the PC that is connected to the Command Port.
3. Win3.1 users - access Run by clicking the File menu in Program Manager and then click Run. In the Run dialog box, type a:\setup or b:\setup (depending on the letter of your disk drive) in the Command Line field and then click OK.
Win95/NT users - click the Start box and then click Run. In the Run dialog box click the down arrow and choose a:\setup.exe or b:\setup.exe (depending on the letter of your disk drive) in the Command Line field and then click OK.
4. Click Next> to continue, then follow the on-screen instructions to install your MultiFRAD software.
5. The Choose Destination Location screen is displayed.
Accept the default (MF2000) by clicking Next> (or pressing the Enter key); otherwise, click Browse to select a different folder for your MultiFRAD software.
6. The Select Program Folder screen is displayed. Click Next> to continue.
18
Chapter 3 - Software Loading and Configuration
After all the program files from both disks are loaded, the Setup dialog box is displayed, enabling you to designate the COM port of the PC that is connected to your MultiFRAD. On the Select Port field, click the down arrow and choose the COM port of your PC (COM1 -- COM4) that is connected to your MultiFRAD. Click OK to continue.
7. The Setup Complete screen is displayed.
8. Click Finish to continue configuring your MultiFRAD. The Do you want to download default
setup? dialog box is displayed.
9. Click Yes to continue. A series of five Setup and Configuration dialog boxes will now be displayed.
The On-Line Help system provides detailed explanations of each dialog box and option. To access Help, click the ? button on the dialog box for which you need additional information.
If your network protocol is IPX, continue with the following steps. If your network protocol is IP, click the IPX Routing Enable check box to clear it and disable IPX, then click OK and proceed to step 14.
10. Router Name: You can either use the default Router Name (MultiFRAD 2000) or assign a new
Router Name in this field. The Router Name must be a printable ASCII string of a maximum of 47 characters. The MultiFRAD uses this name to advertise its service throughout the IPX internetwork.
11. Ethernet: You can enable or disable Auto Learn Ethernet Network Numbers by clicking Auto Learn
Ethernet Network Numbers to check or uncheck the box.
19
MultiFRAD II User Guide
If your network DOES NOT include a file server, we recommend disabling Auto Learn; the MultiFRAD or the network administrator can assign the network numbers.
If your network DOES include a file server, we recommend enabling Auto Learn and allowing the MultiFRAD to learn the IPX network numbers from the file server. WARNING: If the file server and MultiFRAD lose power, the MultiFRAD may reboot quicker than the server and assign the network numbers before the file server can; the MultiFRAD polls the server 20 times and if it receives no response it will assign the network numbers.
If you select No for Auto Learn, record the network numbers assigned by the network file server for each of the four frame types (Raw (802.3), LLC (802.2), EthernetII (Type II), SNAP) in the space provided below.
RAW (802.3) Frames Network Number _____________ LCC (802.2) Frames Network Number ______________ TYPE_II Frames Network Number _________________ SNAP Frames Network Number ___________________ WAN Network Number __________________________
When you manually assign network numbers, you must make sure they match the network numbers assigned to your local file server (if any).
12. WAN: Enter the WAN network number for the Frame Relay WAN Port by clicking the Network Number box, backspacing through the default number, and entering your new W AN Number. Make sure the WAN network number is the same as the MultiFRAD on the other end of the link.
The WAN network number has to be assigned by the Network Administrator and must be unique throughout the entire internetwork.
Note: The WAN port does not have the capability of learning the network number, unlike the LAN port (i.e., the WAN port does not have a file server).
13. Click OK when you are satisfied with your selections.
14. If you clicked OK from the IPX Protocol Default Setup dialog box (step 9), the IP Protocol Default Setup dialog box is displayed.
15. To change the IP parameters, proceed to the next step. Clicking OK advances to the WAN Ports Default Setup dialog box. The WAN Ports Default Setup starts at step 21.
16. The default Ethernet IP Address has to be changed to your unique LAN address. Enter an acceptable, unique IP address in the Ethernet port IP Address field.
17. Change the default Subnet Mask and Frame Type to the values you have assigned to your LAN port.
18. The default WAN Address has to be changed to your unique WAN address. Assign an acceptable unique WAN Address to the W AN port.
19. Change the default Subnet Mask and Remote Address for WAN to the values you have assigned to your WAN.
20. Click OK when you are satisfied with your selections.
21. The WAN Ports Default Setup dialog box is displayed. The WAN Port is enabled in this dialog box. Frame Relay is also enabled. If your WAN port is going to be used in Point-to-point protocol, click Enable PPP. When PPP is enabled, the Modem Command Setup field becomes active and either Asynchronous or Direct Connect needs to be checked (enabled).
20
Chapter 3 - Software Loading and Configuration
The WAN port can be further configured (after the software installation is completed) by clicking the MultiFRAD Configuration icon and then clicking the WAN button.
22. Click OK on the WAN Ports Default Setup dialog box.
23. The Data Port Configuration dialog box enables you to individually configure the two data channels
(Port 1 and Port 2).
If you are connecting a given port to a synchronous device, ensure that the Clocking type and Speed (for Internal clock only) settings are correct. Also, check that the Encoding Scheme, Between Frames, and InterFrame Timer settings are correct for your channel device. Refer to user documentation for the channel device parameters.
If you are connecting to an Asynchronous data device, select Asynchronous, then select the appropriate maximum Speed from the drop-down list. Refer to the user documentation for the parameters of the data device.
24. If your MultiFRAD is going to be connected in a Point-to-Point configuration, then Data Port Mode
defaults to APSM and all other modes are inactive. The APSM option is recommended when LAN traffic and both data channels are mapped to a single
frame relay DLCI. The Encapsulated option is recommended when a synchronous data channel and LAN traffic are
combined on a single frame relay DLCI. The Raw option can be used when there is no LAN traffic and each data channel is mapped to an
individual DLCI. This option is also recommended for use when a 3rd party FRAD is interpreting data. In the Raw data mode, the MultiFRAD adds two bytes of header information before sending data from the data channel out on the frame relay network.
21
MultiFRAD II User Guide
25. If your data device is an asynchronous device, click Asynchronous to enable it, then set the Speed (for Internal Clocking) in the drop-down list. Also select the Word Length, Parity, Stop Bits, etc. for your device. Refer to the user documentation for the parameters of the data device.
If your data device is a synchronous device, ensure that the clocking is correct, also the Speed if an internal clock is used. Also check that the Encoding Scheme, Between Frames, and InterFrame Timer settings are correct for your channel device, per user documentation.
26. Click OK when you are satisfied with the configurations for both data ports. If you enabled PPP in the WAN Ports Default Setup dialog box, proceed to step 28.
27. If you enabled Frame Relay in the WAN Ports Default Setup dialog box, the Frame Relay DLCI Default Setup dialog box is displayed with all the groups inactive. Click OK to continue.
When your MultiFRAD is connected to an active frame relay network service, it can detect DLCIs and the frame relay management type. However, at this point your MultiFRAD is not yet communicating with the frame relay network. We recommend that you finish loading the software and then access the frame relay dialog box from the main Setup dialog box.
28. The Checking MultiFRAD dialog box is displayed.
The Setup utility is "Ready to Download default setup Choose OK to proceed." Click OK to proceed.
29. Writing Setup dialog box is displayed as the setup configuration is written to the MultiFRAD.
30. After the setup is written to the MultiFRAD, the unit reboots.
31. During reboot, the Fail LED on the MultiFRAD is On. Wait for the Fail LED to go Off.
22
Chapter 3 - Software Loading and Configuration
32. Win3.1 users - you are returned to your Program Manager where the MultiFRAD Program Group
and Program Item (Windows icons) have been created. Win95/NT users - you are returned to your MultiFRAD 2000 folder which will be visible on your
desktop. Your MultiFRAD is operational at this time.
33. To map the detected DLCIs to your data ports and protocols, proceed with the following steps:
Win3.1 users - from the Program Manager, click the MultiFRAD Configuration icon in the MultiFRAD 2000 Program Group. The main Setup dialog box is displayed.
Win95/NT users - from your desktop, click Programs, MultiFRAD 2000, then MultiFRAD Configuration. The main Setup dialog box is displayed.
34. On the main Setup dialog box, click Frame Relay.
35. A Frame Relay dialog box stating “MultiFRAD has detected and added following DLCIs.” is displayed.
Click OK.
36. A second Frame Relay dialog box is displayed, stating “MultiFRAD has detected Management Type
to be Annex D. Hence it has set Management type to Annex D from LMI”. The Management Types are Annex A, Annex D, or LMI. Any one of them could appear in this dialog box.
Click OK and the Frame Relay DLCI dialog box is displayed.
23
MultiFRAD II User Guide
37. Click the DLCI you want to map. The Protocol Mappings, Port Mappings, and all the other groups become active.
38. To map this DLCI to one or more data ports, click (in the Port Mappings group) the desired Data Port number(s) (1 and/or 2) that you want to associate with this DLCI.
39. Ensure that Throttle Up and Down is selected in the Congestion Management group.
40. Ensure that Adhere to CIR + Be is selected in the Mode group. Multi-T ech recommends using this setting initially .
41. Double-click the Committed Information Rate text box in the Settings (in Bits/second) group and enter the CIR value your service provider supplied for this DLCI.
42. Double-click the Excess Burst Rate (Be) text box in the Settings (in Bits/second) group and enter the Be value your service provider supplied for this DLCI.
The Compression option may be useful at low link speeds; however, do not use this feature with a high speed link.
The Management Type is assigned by your frame relay service provider. Do not change this assignment for any detected DLCI.
43. Repeat steps 33 through 42 for each new DLCI.
44. Click OK when you are satisfied with all your selections.
45. The Writing Setup dialog box is displayed as the setup configuration is written to the MultiFRAD.
46. After the setup is written to the MultiFRAD, the unit reboots.
47. During reboot, the Fail LED on the MultiFRAD is On. Wait for the Fail LED to go Off.
48. Win3.1 users - you are returned to your Program Manager where the MultiFRAD 2000 Program Group and Program Item (Windows icons) have been created.
Win95/NT users - you are returned to your MultiFRAD 2000 folder which will be visible on your desktop.
Your MultiFRAD is operational at this time.
24
Router/Two-Port Frame Relay Access Device

Chapter 4 - MultiFRAD Software

MultiFRAD II User Guide

Introduction

This chapter describes the MultiFRAD 2000 software from an applications approach in how the configuration can be changed with recommendations on the impact of that change. The major configuration parameters were set during your loading of the software and downloading of your configuration at the end of the software installation. The MultiFRAD 2000 software is designed for the Microsoft ® Windows ® environment.
Recommendations are provided in some case that if you change this parameter or that parameter, it may af fect your unit in this way. The approach in this chapter is not to cover every dialog box and describe every option, your new Help menu system provides that information. The Help menus define each button, option, field, and recommend values where applicable. The Help menus are a dynamic help system in that information is presented corresponding to the active dialog box. You do not have to scan through unrelated information in order to find the Help menu you are looking for.

Before You Begin

To view or change your MultiFRAD configuration in Windows 95/NT, click the Start button, point to Programs, then MultiFRAD 2000, and click MultiFRAD Configuration. You may also start the MultiFRAD Configuration from My Computer by selecting the mf2000 folder and double-clicking on the Fradcon.exe file in the file list.
26
MultiFRAD Configuration is discussed in detail later in this chapter. A brief description of the other components is provided here:
Download User Defaults
This feature allows you to download the user default settings, configured during installation, to the MultiFRAD. If you have made changes to the MultiFRAD configuration and wish to revert to the default setup, you can do so through the MultiFRAD 2000 program group.
Download Factory Defaults
Choose Download Factory Defaults to download the factory default settings. If the MultiFRAD is running, you will be queried to reboot. Click Yes to continue with the download. Y ou will then be presented with a dialog for IP Setup. These screens will contain the original setup information. Click OK on each to accept the default settings, or make any necessary changes and then click OK. When prompted, click OK again to proceed with the download. The default setup will be written to the MultiFRAD. This process may take a few minutes. When it is finished, you will be returned to Windows.
Loading...
+ 59 hidden pages