Intelligent Wireless Router
MTCBA-Xx-EN3
S000508A, Revision A
Copyright
This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-Tech
Systems, Inc. All rights reserved.
Multi-Tech Systems, Inc. makes no representation or warranties with respect to the contents hereof and specifically disclaims
any implied warranties of merchantability or fitness for any particular purpose.
Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in
the content hereof without obligation of Multi-Tech Systems, Inc., to notify any person or organization of such revisions or
changes. Check Multi-Tech’s Web site or product CD for current versions of our product documentation.
Trademarks and registered trademarks of Multi-Tech Systems, Inc. include MultiModem, the Multi-Tech logo, and MultiTech. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. All other products
or technologies referenced in this manual are the trademarks or registered trademarks of their respective holders.
Contacting Multi-Tech Support
Online Support Portal: https://support.multitech.com
In order to better serve our customers, manage support requests and shorten resolution times, we have created the online web
portal allowing you to submit questions regarding Multi-Tech products directly to our technical support team. Get answers to
your most complex questions, ranging from implementation, troubleshooting, product configuration, firmware upgrades and
much mor e .
To create an account and submit a Support Case on the Portal, visit
https://support.multitech.com.
Knowledge Base and Support Services:www.multitech.com/support.go
The Knowledge Base provides immediate answers to your questions and gives you access to support resolutions for all MultiTech products. Visit our support area on the website for other support services.
World Headquarters
Multi-Tech Systems, Inc.
2205 Woodale Drive, Mounds View, Minnesota 55112 U.S.A.
Phone: 763-785-3500 or 800-328-9717 Fax: 763-785-9874
Internet Address: www.multitech.com
Technical Support
Business Hours: M-F, 9am to 5pm CST
Country By Email By Phone
Europe, Middle East, Africa: support@multitech.co.uk (44) 118 959 7774
U.S., Canada, all others: support@multitech.com (800) 972-2439 or (763) 717-5863
Warranty
Warranty information can be found at:
http://www.multitech.com/warranty.go
2 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Table of Contents
Table of Contents
CHAPTER 1 – INTRODUCTION AND PRODUCT DESCRIPTION ...................................... 4
Related Documentation .................................................................................................................................................................. 4
Front Panel ..................................................................................................................................................................................... 6
Cellular Information ....................................................................................................................................................................... 9
Insert the SIM Card into Holder, If required ................................................................................................................................ 11
Making the Connection ................................................................................................................................................................ 11
Optional – Attach the Router to a Flat Surface ............................................................................................................................ 11
Set Your PC’s TCP/IP Address for Ethernet Functionality ......................................................................................................... 13
Configure Ethernet Interface Using Web Management Software ................................................................................................ 15
Verifying Signal Strength............................................................................................................................................................. 17
Account Activation for Wireless Devices .................................................................................................................................... 17
CHAPTER 3 - USING THE WEB MANAGEMENT SOFTWARE .............................................. 19
Navigating the Web Management Software................................................................................................................................. 19
Web Management Software Screens ............................................................................................................................................ 21
IP Setup ........................................................................................................................................................................................ 21
Networks & Services > Service Configuration ............................................................................................................................ 34
GRE Tunnels ................................................................................................................................................................................ 40
DHCP Server ................................................................................................................................................................................ 42
Statistics & Logs > System Information ................................................................................................................................... 51
Statistics & Logs > Modem Information .................................................................................................................................. 55
Statistics & Logs > Service Status ............................................................................................................................................ 55
Statistics & Logs > TCP/UDP Client Live Log ........................................................................................................................ 55
Statistics & Logs > TCP/UDP Server Live Log ....................................................................................................................... 55
Statistics & Logs > IPSec Live Log ......................................................................................................................................... 56
APPENDIX A – COMMONLY SUPPORTED SUBNETS REFERENCE TABLE .............. 57
APPENDIX B – REGULATORY COMPLIANCE ........................................................................ 59
EMC, Safety, and R&TTE Directive Compliance ....................................................................................................................... 59
FCC Part 15 Class B Statement .................................................................................................................................................... 59
Industry Canada ........................................................................................................................................................................... 59
APPENDIX C – ENVIRONMENTAL INFORMATION ............................................................ 60
Restriction of the Use of Hazardous Substances (RoHS) ............................................................................................................. 61
China ROHS ................................................................................................................................................................................ 62
Index ............................................................................................................................................................................................ 63
Multi-Tech Systems, Inc. MultiModem rCell User Guide 3
Chapter 1 – Introduction and Product
Description
This User Guide describes the MultiModem® rCell intelligent wireless routers with an Ethernet II interface. The MultiModem
rCell Router is configured for one of three connecti vi t y m od e s: alway s - on , wake - up on ri n g, o r dial -o n demand. The always-on
network connection automatically establishes a wireless data connection and allows for around the clock surveillan ce,
monitoring or real time data acquisition of any remote Ethernet device such as a Web camera. If the data link is dropped in the
event of poor reception or a complete loss of service, it will automatically re-establish the data link. The wake-up on ring
configuration allows the router to “wake up” and initiate a connection when it detects an incoming ring. For security reasons,
you can setup the router to wake up based on a particular caller ID number. This configuration is ideal for reducing the costs
associated with the modem being online and available 24/7. When configured for dial-on demand, the router only accesses the
Internet when data is present. This configuration is ideal for sharing Internet access among networked PCs.
Model Description
MTCBA-H3-EN3-P1
MTCBA-EV1-EN3-N3
Quad-band HSPA 7.2
Quad-band EV-DO Rev A Performance
Related Documentation
MultiModem MTCBA-H3-EN3 (HSPA)
AT Commands: The MultiModem MTCBA-H3-EN3 wireless router is configured using the HSPA-H3 AT Commands.
These commands are documented in the Reference Guide number S000505x.
MultiModem MTCBA-EV1-EN3 (EV-DO)
AT Commands: The MultiModem MTCBA-EV1-EN3 wireless router is configured using the EV-DO AT Commands.
These commands are documented in the Reference Guide number S000506x.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 4
Chapter 1 – Introduction and Description
Safety Warnings
Ethernet Ports Caution
The Ethernet ports are not designed to be connected to a Public Telecommunication Network or used outside the building.
RF Safety
The remote modems are cellular devices. It is important to follow any special regulations regarding the use of radio
equipment due in particular to the possibility of Radio Frequency (RF) interference.
Caution: A separation distance of at least 20 cm must be maintained between the modem transmitter’s antenna and the body
of the user or nearby persons. The modem is not designed for or intended to be used in portable applications within 20 cm of
the body of the user.
Check your local standards regarding safe distances, etc.
● Operation of a cellular modem close to other electronic equipment may also cause interference if the equipment is
inadequately protected. Observe any warning signs and manufacturers’ recommendations.
● Different industries and businesses have their own restrictions governing the use of cellular devices. Please observe
the local restrictions of the environment where you intend to operate the cell modem.
● Under no circumstances should antenna be placed outdoors.
Internal Lithium Battery
●A lithium battery located within product provides backup power for the timekeeping capability. The battery has an
estimated life expectancy of ten years.
●When the battery starts to weaken, the date and time may be incorrect. If the battery fails, the board must be sent
back to Multi-Tech Systems for battery replacement.
●Lithium cells and batteries are subject to the Provisions for International Transportation. Multi-Tech Systems Inc.
confirms that the Lithium batteries used in the Multi-Tech product(s) referenced in this manual comply with Special
Provision 188 of the UN Model Regulations, Special Provision A45 of the ICAO-TI/IATA-DGR (Air), Special
Provision 310 of the IMDG Code, and Special Provision 188 of the ADR and RID (Road and Rail Europe).
Warning! There is danger of explosion if the battery is incorrectly replaced!
Multi-Tech Systems, Inc. MultiModem rCell User Guide 5
Chapter 1 – Introduction and Description
Front Panel
The front panel contains Power and Status LEDs, two Ethernet LEDs, two modem LEDs, and three signal LEDs. The Power
LED indicates that DC power is present and the Status LED blinks when the unit is functioning normally. The two Ethernet
LEDs indicate transmit and receive activity and connection speed of 10 or 100Mbps on the Ethernet link. The two modem
LEDs indicate carrier detection and link status. The three signal LEDs display the signal strength level of the wireless
connection. The SIM door on the right side of the router provides access to the SIM card holder on the H3 version.
LED Indicators
Power
Status
LNK
SPD
Signal
Indicates presence of DC power when lit.
The LED is a solid light when the rCell is booting up, saving the configuration, restarting, or updating the firmware.
When the Status LED begins to blink, the router is ready.
Link. Blinks when there is transmit and receive activity on the Ethernet link. It shows a steady light when there is a
valid Ethernet connection.
Speed. Lit when the Ethernet is linked at 100 Mbps. If it is not lit, the Ethernet is linked at 10 Mbps.
Carrier Detect. Lit when data connection has been established.
CD
LS Link Status Dependent on Model
H3 Version EV1 Version
Permanently On: Powered on and
connected, but not transmitting or
receiving.
Slow flashing state (5 Seconds)
Powered on searching for a connection.
Fast flashing state (0.3 seconds)
Transmitting and receiving.
ALL OFF - Unit is off, not registered on network, or extremely weak signal (0 < = RSSI < 6).
1 Bar “ON” – Very weak signal (7 < = RSSI <14)
1 Bar and 2 Bar “ON” – Weak signal (15 < = RSSI <23)
1 Bar, 2 Bar, and 3 Bar “ON” – Good signal (24 <= RSSI > = 31)
Permanently On: Not registered on network.
Flashing states:
200 ms on/2 sec off
Registered on network.
200 ms on/600 ms off
Registered on the network and communications in progress
100 ms on/200 ms off
Software downloaded is either corrupted or non-compatible (“bad
software”)
Note: If required, your wireless provider will supply the SIM card.
6 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Specifications
Features MTCBA-H3-EN3 MTCBA-EV1-EN3
Standard
Band, Frequency
Packet Data
Circuit-Switched
Data
Short Message
Services-SMS
Antenna
Connector
SIM Connector
Power Connector
Voltage
Physical
Description
Operating
Temperature *
Storage Temp
Humidity
Certifications EMC Compliance
Chapter 1 – Introduction and Description
HSPA CDMA2000 1xRTT EV-DO Rev. A
(backward compatible to EV-DO Rev. 0 and
CDMA 1x networks) SMS is based on
CS/Packet-switched (PS) domain of GSM
and WCDMA
HSPA/HSDPA/UMTS Triple-band:
2100/1900/850 MHz with Rx diversity
Dual-band 800/1900 MHz bands with
Receive Diversity support on both bands
GSM/GPRS/EDGE:
850/900/1800/1900
HSDPA data service of up to 7.2 Mbps
HSUPA data service of up to 5.76 Mbps
Peak download 3.1 Mbps, peak upload
1.8 Mbps
Up to 14.4K bps, non-transparent --
Text & PDU, Point-to-Point (MO/MT),
Point-to-Point messaging (M O/ M T)
cell broadcast
RF Antenna: 50 ohm SMA (female
RF Antenna: 50 ohm SMA (female
connector)
Standard 1.8 and 3V SIM receptacle --
2.5mm miniatu re (s cr ew -o n)
5 VDC
7”W x 1.24”H x 2.93”D 0.75lbs
17.78cmW x3.15cmH x7.44cmD 0.340Kg
-30° to +60° C* -40° to +75° C*
-40° to +85° C*
Relative humidity 20% to 90% noncondensing
EMC Compliance
FCC Part 15 Class B
EN55022 Class B
FCC Part 15 Class B
Radio Compliance
EN55024
Radio Compliance
FCC Part 22, 24
RSS132,133
Safety: UL60950-1, 2
IEC60950-1:2005 (Second Edition
with EN 60950-1:2006+A11:2009
EN301 489-1
EN489-3 (-GP only)
EN301 489-7
EN301 489-24
AS/ACIF S042.1, S042.3
Safety: UL60950-1, 2
nd
Edition
IEC60950-1:2005 (Second Edition with
EN 60950-1:2006+A11:2009
Network: PTCRB, AT&T
connector)
FCC Part 22, 24
nd
Edition
* UL Listed @ 40° C, limited by power supply. UL Certification does not apply or extend to an ambient above 40°
C and has not been evaluated by UL for ambient greater than 40° C.
“ UL has evaluated this device for use in ordinary locations only. Installation in a vehicle or other outdoor locations
has not been evaluated by UL. UL Certification does not apply or extend to use in vehicles or outdoor applications
or in ambient above 40° C.”
Note: The radio's performance may be affected at the temperature extremes. This is considered normal. The radio is
designed to automatically fallback in class and reduces transmitter power to avoid damage to th e radio. There is no
Multi-Tech Systems, Inc. MultiModem rCell User Guide 7
Chapter 1 – Introduction and Description
single cause for this function. Rather, it is the result of an interaction of several factors, such as the ambient
temperature, the operating mode and the transmit power.
8 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Power
Power Draw for MTCBA-H3-EN3 (GSM850/HSD PA) product:
Input Voltage=
5.0Volts Idle Mode Typical Maximum Peak Tx
GSM850
Current(AMPS)
Watts
HSDPA
Current(AMPS)
0.345 0.450 1.20 3.60
1.76 2.29 5.94
0.345 0.760 1.01 1.40
Chapter 1 – Introduction and Description
Peak Rst
(Inrush
Current)
Watts
1.76 3.84 5.03
Inrush Current
(AMPS)
(approx. 3ms
duration)
2.66
Power Draw for MTCBA-EV1-EN3 (US PCS/US Cellular):
Peak Rst
Input Voltage=
5.0Volts Idle ModeTypicalMaximumPeak Tx
US CELLULAR
Current(AMPS)
Watts
US PCS
Current(AMPS)
Watts
0.305 0.450 0.805 1.12
1.54 2.26 4.06
0.305 0.505 1.06 1.38
1.54 2.53 5.11
(Inrush
Current)
Inrush Current
(AMPS) (approx.
3ms duration)
NOTE: Multi-Tech Systems, Inc. recommends that the customer incorporate a 10% buffer into their power source when
869 to 894 MHz 925 to 960 MHz 1805 to 1800 MHz 1930 to 1990 MHz 869 to 894 MHz 1930 to 1990 MH z
824 to 849 MHz 880 to 915 MHz 1710 to 1785 MHz 1850 to 1910 MHz 824 to 849 MHz 1850 to 1910 MH z
2W at 12.5%
duty cycle
2W at 12.5%
duty cycle
Cellular Information
Antenna System for Cellular Devices
The cellular/wireless performance is completely dependent on the implementation and antenna design. The integ ration of the
antenna system into the product is a critical part of the design process; therefore, it is essential to consider it early so the
performance is not compromised. If changes are made to the certified antenna system of the MultiModem, then recertification
will be required by specific network carriers such as Sprint. The Antenna System is defined as the UFL connection point from
the MultiModem to the specified cable specifications and specified antenna specifications.
PTCRB Requirements for the Antenna
There cannot be any alteration to the authorized antenna system. The antenna system must maintain the same specifications.
The antenna must be the same type, with similar in-band and out-of-band radiation patterns.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 9
1W at 12.5% duty
cycle
1W at 12.5% duty
cycle
- -
Chapter 1 – Introduction and Description
FCC Requirements for the Antenna
The antenna gain, including cable loss, for the radio you are incorporating into your product design must not exceed the
requirements at 850 MHz and 1900 MHz as specified by the FCC grant for mobile operations and fixed mounted operations
as defined in 2.1091 and 1.1307 of the FCC rules for satisfying RF exposure compliance. The antenna used for transmitting
must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with
any other antenna transmitters. User and installers must be provided with antenna installation instructions and transmitter
operating conditions to satisfying RF exposure compliance.
Antenna Specifications
CDMA Antenna Requirements/Specifications
Frequency Range
Impedance
VSWR
Typical Radiated Gain
Radiation
Polarization
TRP/TIS
824 – 894 MHz / 1850 – 1990 MHz
50 Ohms
VSWR shall not exceed 2.0:1 at any point across the bands of operation
3 dBi on azimuth plane
Omni-directional
Vertical
The total radiated power (TRP) at the antenna shall be no less than
+21/20 dBm for PCS/CELL channels respectively, and the total isotropic
sensitivity (TIS) at the antenna shall be no less than -104/104 dBm for
PCS/CELL channels respectively.
GSM Antenna Requirements/Specifications
Frequency Range
Impedance
VSWR
Typical Radiated Gain
Radiation
Polarization
TRP/TIS
824 – 960 MHz / 1710 – 1990 MHz
50 Ohms
VSWR shall not exceed 2.0:1 at any point across the bands of operation
3 dBi on azimuth plane
Omni-directional
Vertical
Including cable loss the total radiated power (TRP) at the antenna shall be
no less than +22/24.5 dBm for 850/1900 MHz respectively, and the total
isotropic sensitivity (TIS) at the antenna shall be no less than -99/101.5
dBm for 850/1900 MHz respectively.
10 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Chapter 2 - Installation
Insert the SIM Card into Holder, If required
The router requires the power supply connection to begin operation. It also requires a SIM card (Subscriber Identity Module)
to operate on a GSM network. To install the SIM, do the following:
1. Open the SIM door by pressing down on the tab on the top of the door and prying it open.
Note: When changing a SIM, ensure that power is removed from the unit.
2. Insert the SIM card into the card holder. The above graphic illustrates the correct SIM card orientation.
3. Verify that the SIM card fits into the holder properly and then close the cover.
Making the Connection
1. Connect a suitable antenna to the SMA connector (see antenna specifications in Chapter 1).
2. Using an Ethernet cable, connect one end of the cable to the ETHERNET connector on the back of the router and the
other end to your pc either directly or via a switch or hub.
3. Attach the appropriate interchangeable blade piece to the power supply module.
4. Screw-on the power lead from the power supply module into the power connection on the router. Now, plug the power
supply into your power source.
Notes
The POWER LED. The POWER LED lights after power-up.
●
● The
Status LED is a solid ON when the router is booting up, saving a configuration, or updating firmware. When
Status LED begins to blink, the router is ready.
the
The Reset Button. Hold the Reset button in until the Status Light goes out. Then release it. It also will set the
username and password back to admin and admin as well as setting the IP address to the default of 192.168.2.1.
Optional – Attach the Router to a Flat Surface
Before you mount your router to a permanent surface, verify signal strength, refer to Verify Signal Strength in this Chapter.
The router can be panel mounted with screws spaced according to the measurement shown.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 11
Chapter 2 – Installation
Note: Use either #6 or #8 pan head screws for all four mount locations.
12 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Chapter 2 – Installation
Set Your PC’s TCP/IP Address for Ethernet Functionality
The following directions establish a TCP/IP connection at the pc so the PC can communicate with the router. The following
directions were written using a Windows XP/ 2003+ operating system.
1. Click Start | Control Panel. Double-click the Network Connections icon.
2. The Network Connections screen displays. Right-click the Local Area Connection icon and choose Properties from
the drop down list.
3. The Local Area Connection Properties dialog box displays.
● Select Internet Protocol [TCP/IP].
● Click the Properties button. The Internet Protocol (TCP/IP) Properties screen displays.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 13
Chapter 2 – Installation
4. The Internet Protocol (TCP/IP) Properties screen.
Important Note:
If this screen opens and displays your curren t IP configuration, we suggest you record this information for future
reference (i.e., after the router is configured, you may wish to return this PC to its original settings).
● To set a Fixed IP Address for the pc, select Use the following IP address.
● Enter the pc IP Address. Example: 192.168.2.x.
Note: The x in the address stands for numbers 101 and up.
● Enter the pc Subnet Mask. Example: 255.255.255.0
● Enter the pc Default Gateway. Example: 192.168.2. 1
Note: The pc settings must be in the same subnet range as the router.
The factory default settings for the router are:
IP Address: 192.168.2.1
Subnet Mask: 255.255.255.0
● Select Use the following DNS server addresses.
● Enter the IP Address for the Preferred DNS Server. Example: 205.171.3.65
● Click OK.
● Close the Local Area Properties screen by clicking OK.
● Close the Control Panel.
● Repeat these steps for each PC on your network.
14 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Chapter 2 – Installation
Configure Ethernet Interface Using Web Management
Software
You are now ready to configure the Ethernet interface. This is accomplished by using the router's factory-installed Web
Management software. The software is accessed through a Web browser.
1. Open a Web browser
From the pc, open a Web browser.
Note: Ensure that the Status LED is blinking, indicating that the router is ready.
2. Type the default Gateway Address: http://192.168.2.1
3. Login
After entering the Address, the Login screen displays.
● Type the default User Name: admin (all lower-case).
● Type the default password: admin (all lower-case).
Note: The User name and Password are case-sensitive (both must be typed in lower-case).
A password can be up to 12 characters. If Windows displays the AutoComplete screen, you may want to click
No to tell the Windows OS not to remember the password; this helps maintain PC security.
Password Caution: It is recommended that you change the default password to better protect the security of your
router. Use a safe password! Your first name spelled backwards is not a sufficiently safe password; a password
such as xfT35$4 is better.
●Click the Login button. The Web Management Home screen displays.
4. Use the Wizard Setup for Quick Configuration
A quick way to configure the router is to use the Wizard Setup. The Wizard Setup can be opened by clicking the words
Wizard Setup located under the Web Management software’s menu bar. The information entered here will default to
other screens that require this information.
Benefits of Using the Wizard Setup
● Saves time by allowing you to configure the basic setup in one screen.
Note: Additional features and functions can be set up using the complete Web Management software program,
described in Chapter 3.
●Provides a short way to enter and save information needed to create a connection to the Internet.
Select Wizard Setup
Multi-Tech Systems, Inc. MultiModem rCell User Guide 15
Chapter 2 – Installation
5. After clicking the Wizard Setup selection, the Wizard Setup screen displays.
Wizard Setup
A minimum router configuration is provided using the Wizard Setup. This provides a quick way to enter and save information
needed to create a connection to the Internet. The table below provides the information for the minimum configuration.
IP Configuration
IP Address The default is 192.168.2.1. To change it, simply enter your own IP addr ess.
Mask The default is 255.255.255.0
DNS Enter the primary DNS IP address for the system. The default is 0.0.0.0
PPP Configuration
PPP The default is disable. To connect to the Internet, you need to enable PPP.
Depending on the model, commands may need to be issued to the integrated cellular
modem before connecting to the wireless service. To issue commands to the integrated
cellular modem, PPP must be disabled and telnet port 5000 used.
Dial-onDemand
Idle Time Out Sets the amount of time the PPP link stays active before disconnecting. Setting the
Dial Number Enter the dial number. This number connects you to the Internet.
APN For HSPA models, enter the APN (Access Point Name). The APN is assigned by your
Init String You can set up to 4 router initialization strings.
Authentication
Type
Username Enter the PPP Username. This name authenticates the remote peer.
Password Enter the PPP Password. This password authenticates the remote peer.
The default is disable.
value to zero causes the link to stay active continuously.
For HSPA, the number is *99***1#.
For EV-DO models, the Dial Number is #777.
wireless service provider.
For EV-DO models, the APN does not apply
PPP Authentication
Click the button corresponding to the authentication protocol you want to use to
negotiate with the remote peer. PAP, CHAP, or PAP- CHAP.
Default = PAP-CHAP
16 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Chapter 2 – Installation
A Note About the Access Point Name
The APN (Access Point Name) is assigned by your wireless service provider, but you may have to ask for it. An access
point is an IP network to which a MultiModem rCell Router connects. The Web Management software asks for the
APN on the Wizard Setup screen and the PPP screen.
Important Note About Provider Fees
Your provider will charge you for your data usage. Please check with your provider to make sure you are aware of the
charges.
If you plan to use the router for large amounts of data transfers, Multi-Tech recommends an unlimited data plan with
your account. Multi-Tech will not be responsible for any charges relating to your cellular bill.
Note: Additional features and functions can be set up using the complete Web Management software program,
described in Chapter 3.
6. Click the Submit button.
7. Click the Save & Restart button (located on the Menu bar). The router will reboot.
IMPORTANT NOTE ABOUT SUBMIT AND SAVE & RESTART
Click the Submit button located at the bottom of most screens in order to save any changes you make.
Then you click the Save & Restart button, located on the Menu bar, in order for your settings to take
effect. Save & Restart does not have to be executed after each screen; you can change and Submit
Verifying Signal Strength
To communicate directly with the cellular modem to verify signal strength, telnet to the modem.
Note: Ensure that the Status LED is blinking, indicating that the router is ready. Ensure that PPP is disabled before verifying
signal strength.
1. To Telnet to the modem. You can access the modem thru the Run icon or from the Command Prompt:
Click Start I Run icon. In the Open window, enter cmd and then press ENTER.
or
Click Start I All Programs I Accessories I Command Prompt
● In the command window, type telnet 192.168.2.1 5000
● At the Login prompt, type the default user name: admin (all lower-case). Press ENTER
● At the Password prompt, type the default password: admin (all lower-case). Press ENTER
2. In the command window, type AT+CSQ . The router responds with the received signal strength (rssi).
Once you have a good signal for where you are going to place the router, either refer back to Optional Mounting in this
Chapter if you are permanently mounting your router or continue with Account Activation for Wireless Devices.
Account Activation for Wireless Devices
Please refer to Multi-Tech’s Cellular Activation Web site at http://www.multitech.com/activation.go for information on
activating your cellular modem.
Note: If you need remote access to your MultiModem over the Internet for remote configuration, you need to ensure
that your wireless network provider has provisioned mobile terminated data and fixed or dynamic public IP address in
which they can configure the network to redirect any incoming connection to that predefined IP.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 17
Chapter 3 - Using the WEB Management
Software
The Web Management software configures the Ethernet functionality of your router.
Navigating the Web Management Software
This section explains the menu structure and the navigation buttons of the router’s Web Management software.
Menu Bar
IP Setup: Sets up a General Configuration, HTTP, DDNS, SNTP, Static Routes, and Remote Configuration.
PPP: Sets up the PPP authentication,dial-on-demand, router authentication, and Wakeup on Call.
Networks & Services:Defines networks and services to make them available to other functions such as allowed packet filters,
static routes, remote configuration, DNAT, and GRE tunnels and routes.
Packet Filters: Defines filter rules, DNAT configuration, and ICMP rules.
GRE Tunnels: Generic Routing Encapsulation (GRE). Defines the remote network and the tunnel through which traffic is to
be routed.
DHCP Server:Configures the DHCP server settings.
IPSec: Allows device to support LAN-to-LAN VPN tunneling with 3DES and AES 128-192-256 encryption support
Tools: Sets DDNS Force Update, displays DDNS Status, resets the modem, and provides screens for Firmware Upgrade, Load
Configuration, and Save Configuration.
Statistics & Logs:Shows statistics and logs maintained by the router.
Save & Restart: Saves your settings and reboots your router.
Help Index: Accesses the online Help text.
IMPORTANT NOTE ABOUT USUBMITU AND USAVE & RESTART
Click the Submit button located at the bottom of most screens in order to save any changes you make.
Then you must click the Save & Restart button, located on the Menu bar, in order for your settings to take effect. Save &
Restart does not have to be executed after each screen; you can change and Submit several screens, and then click Save &
Restart.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 19
Chapter 3 – Using the Web Management Software
Screen Parts
Menu Bar Submenu Title Submenu List
Screen Buttons
Screen Name
Screen Input
Area
Screen Buttons
Home: Click this button to return to the Home screen.
Wizard Setup:Click this button to display the Wizard Setup screen on which you can quickly set up your MultiModem
rCell Router with basic configuration settings.
Logout:Click this button to Logout and return to the login screen.
Help:Click this button to display the Help text.
Submenus
The submenus display on the left side of the screen.
The following table shows the sub-menu selections under each main menu category.
Firmware Upgrade
Load Configuration
Save Configuration
SysInfo
Ethernet
PPP
PPP Trace
DHCP Statistics
GRE Statistics
Modem Info
Service Status
TCP/UDP Client Live Log
TCP/UDP Server Live Log
IPSec Live Log
IPSec Log Traces
Tunnels
GRE Tunnels
GRE Routes
20 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Chapter 3 – Using the Web Management Software
Web Management Software Screens
The rest of this chapter describes each of the Web Management software screens.
IP Setup
IP Setup > General Configuration
In the General Configuration, you will set the general system-based parameters.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 21
Chapter 3 – Using the Web Management Software
General Configuration
Date and Time: The system date and time display in these formats: MM/DD/YYYY / HH:MM:SS. A real time clock is part
of SNTP to display proper time.
IP Configuration
Enter the following addresses for the Ethernet interface.
IP Address (Default = 192.168.2.1), Mask (Default 255.255.255.0), Default Gateway (Default 0.0.0.0),
Primary DNS (Default 0.0.0.0), Secondary DNS (Default 0.0.0.0).
Note: See Appendix A – Table of Commonly Supported Subnets.
Auto Dial out Configuration
Auto Dialout: Check the box to enable/disable Auto Dialout. Default = Enable. The Auto Dialout settings allow you to use the
integrated cellular modem directly with no router functionality. This is accomplished using redirector software on your pc. This
software creates a virtual serial port allowing your pc to communicate with the integrated cellular modem over IP using telnet.
Raw Dialout: Check the box to enable/disable raw mode for an Auto Dialout session. Default = Disable.
Auto Dialout Login: Check the box to enable or disable Auto Dialout Login feature. Default = Enable. The Auto Dialout port
is the telnet port used by the redirector software on your pc to communicate to the integrated cellular modem.
Auto Dialout Port: Enter the serial Auto Dialout Port number. Default = 5000.
Handle EIA Signal: Check the box to enable/disable the EIA standard signal characteristics (time and duration) used between
different electronic devices.
Inactivity: Enter the time in seconds that the auto dialout session will stay active before going inactive.
Syslog Configuration
Syslog: Check the box to enable or disable Syslog. Default = Disable.
Syslog Server IP Address: If a Remote Syslog Server IP Address is specified, the syslog feature acts as a remote Syslog.
Auto Discovery
Auto Discovery: Check the box to enable or disable Auto Discovery to broadcast (MAC level), the MAC Address, IP Address,
and DHCP information to the configured server port. Default = Enable. The router will send a broadcast packet on the
specified server port every 10 seconds or whatever interval the broadcast timer is set to.
Server Port: Enter the Server Port Number. Default port is 1020.
Broadcast Timer: Enter the amount of time in seconds for the auto-discovery packet granularity of periodic broadcasting.
Default is 10 seconds.
Auto Reboot Timer Configuration
Auto Reboot Timer: Enter the number of hours to lapse between each automatic reboot. The default of zero deactivates the
timer. Range is 0 to 999.
Telnet Configuration
Enables/Disables the Telnet port. The default is Enable. This is specifically for telnet port 23 for technical support debug. You
can still access the integrated cellular modem using port 5000 when this is disabled. Ensure that PPP is also disabled before
telnetting to the port.
Submit Button
Click the Submit button to save these settings.
Note: You must click Save and Restart once you have completed and submitted all the screens on which you have made
changes.
22 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Chapter 3 – Using the Web Management Software
IP Setup > HTTP Configuration
HTTP Configuration
HTTP Port: Enter the port number on which the HTTP server will listen for requests. Default is 80.
HTTP Time-0ut:
Authentication
Username: Enter the Username that can access to the Web Management software. Default is admin. This username and
password are also used for telnet access to the router and integrated cellular modem.
Password: Enter the Password for access to the Web Management software. Default is admin.
Note: You should change the password to one of your choosing. I t can be up to100 characters. Use a safe password. Your
first name spelled backwards is not a sufficiently safe password; a password such as xfT35$4 is better. You can also
change the default Username to one of your choosing.
Submit Button
Click the Submit button to save these settings.
Note: You must click Save and Restart once you have completed and submitted all the screens on which you have made
changes.
Set the HTTP session in seconds. The default is 120 seconds.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 23
Chapter 3 – Using the Web Management Software
IP Setup > DDNS Configuration
DDNS (Dynamic Domain Naming System) is dependent upon cellular network/account co nfiguration. DDNS allows you to
have a static domain name with a dynamic IP address. Whenever your dynamic IP address changes, it is submitted to the
DDNS server where your domain name is updated to point to the new IP address.
Note: You have to register with a DDNS server to use this feature.
General
DDNS: Check the Enable or Disable box. This enables/disables DDNS.
Default = Disable.
Use Check IP: Check the Enable or Disable box. If enabled, the program will query the server to determine
the IP address before it performs the DDNS update (the IP address is still assigned by the
wireless provider and the DDNS will be updated based on the address returned by Check IP
Server). If disabled, the program will perform the DDNS update using the IP address that it
obtains from the PPP link. Default = Enable.
Check IP Server: Enter the Server name from which the currently assigned IP address is obtained. This check
IP server is a server the router accesses to check it’s current IP address.
Check IP Port: Enter the port number of the Check IP Server. Default is 80.
Server: Enter the Server name to which the IP Address change is registered. Example:
members.dyndns.org
Port: Enter the Server port number. Default is 80.
Max Retries: Enter the maximum number of tries that will be allowed if the update fails. Default = 5. Range is 0 – 100.
Update Interval: Enter the intervals in days that will be allowed to pass when there is no IP Address change. At
the end of this interval, the existing IP Address will be updated in the server so that it will not
expire. Default = 28 days. Range is 1 – 99 days.
System: Sets the system registration type as either Dynamic or Custom. Default = Dynamic.
Domain: Enter the registered Domain name.
Authentication
Username: Enter the Username that can access the DDNS Server. Default = NULL. You should have
received your username when you registered with the DDNS service.
Password: Enter the Password that can access the DDNS Server. Default = NULL. You should have
received your password when you registered with the DDNS service.
Submit
Click the Submit button to save these settings.
Note: You must click Save and Restart once you have completed and submitted all the screens on which you have made
changes.
IP Setup > SNTP Configuration
24 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Chapter 3 – Using the Web Management Software
General Configuration
SNTP Client: Enable or disable the SNTP Client to contact the configured server on the UDP port 123 and set the local
time. The default is Disable.
Server: Enter the SNTP server name or IP address to which the SNTP Client must contact in order to update the
time. No default.
Polling Time: Enter the polling time at which the SNTP client requests the server to update the time. Default is 300
minutes. Time must be entered in minutes.
Time Zone Configuration
Time Zone: Enter your time zone. Default = UTC (Universal Coordinated Time, Universal Time).
See the following Web site for Time Zone information:
Time Zone Offset: Enter +/- hh:mm. Default = +00:00. Offset is the amount of time varying from the standard time of a
Daylight Configuration
Daylight Saving: Enables/disables Daylight Saving mode. The default is Enable.
Daylight Saving Offset: Set the offset to use during Daylight Saving mode. Default is +60 minutes. Enter the time in + / -
Daylight Saving Start Time
Start Ordinal: Set the start ordinal to use during Daylight Saving mode. Options are first/second/third/fourth/last. Default
Start Month: Set the start month to use during Daylight Saving mode. Default is March.
Start Day: Set the start weekday to use during Daylight Saving mode. Default is Sunday.
Start Time: Set the start time to use during Daylight Saving mode. Default is 02:00 (hh:mm).
is second. Daylight Saving time usually starts at the same time on the same day of the week in the same
month every year. Each day of the week occurs four or five times a month. Therefore, you will be selecting
the week in which daylight saving time starts: the first, second, third, fourth or the last of the month.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 25
Chapter 3 – Using the Web Management Software
Daylight Saving End Time
End Ordinal: Set the end ordinal to use during Daylight Saving mode. Select the week in which daylight saving time
ends. Options are first/second/third/fourth/last. Default is first.
End Month: Set the end month to use during Daylight Saving mode. Default is November.
End Day: Set the end weekday to use during Daylight Saving mode. Default is Sunday.
End Time: Set the end time to use during Daylight Saving mode. Default is 02:00 (hh:mm).
Submit Button
Click the Submit button to save these settings.
Note: You must click Save and Restart once you have completed and submitted all the screens on which you have made
changes.
IP Setup > Static Routes
Routing information is used by every computer connected to a network to identify whether it is sending a data packet directly
to the firewall or passing it on to another network. The options to Delete or Edit a route after it has been defined and added
are available by using the table at the bottom of the screen.
Add Static Routes
IP packets destined for the network indicated in the drop down box are routed to the IP address in the box pointed to by the
arrow. The networks in the drop down box can be defined under the ‘Networks & Services’ tab.
Static Route: Select a static route from the drop down list box, and then click the Add button.
Add Button: After clicking the Add button, the new route is added and will display at the bottom of the screen.
Important Note: The Static Route screen will not display until the network is defined under Networks & Services.
IP Setup > Remote Configuration
Remote Configuration
Add Network/Host for Remote Configuration:
Select a network or host from the drop down box. You can define more networks or hosts under the Network & Services
tab. The choices are Any, LAN, and WAN Interface. Choose all that apply. Click the Add button after each selection.
Add Button: After clicking the Add button, the network or host is added and displays at the bottom of the screen.
Delete: You will have the option to delete Any and WAN Interface in the Options window once it is added. Click on
Delete in the Options window.
26 Multi-Tech Systems, Inc. MultiModem rCell User Guide
PPP
PPP > PPP Configuration
Chapter 3 – Using the Web Management Software
NAT Configuration
NAT Enable/disable NAT (Network Address Translation). The default is Enable.
If NAT is enabled:
●Your LAN can use one set of IP addresses for internal traffic and a second set of addresses for
external traffic. In other words, the router with NAT does the simple IP routing between the LAN
interface and the WAN interface. NAT hides the LAN address behind a single IP address on the
wireless side.
●Your internal addresses are shielded from the public Internet.
If NAT is disabled:
● The router functions without performing any address translation on the packets passing through it.
● Masquerading of packets originating from the LAN is disabled.
● Address translation of packets arriving from the WAN is also disabled.
● Any DNAT Configuration previously setup in the DNAT Configuration screen is disabled. This
prevents the user from adding any DNAT rules, which if allowed would defeat the purpose of
enabling Routing.
Note: For routing to take effect, the configuration must be saved after enabling it. It won’t be effective on
the fly at runtime.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 27
Chapter 3 – Using the Web Management Software
PPP General
PPP Enable/disable PPP. The default is Disable. When enabled, the unit functions as a router. PPP
must be disabled to access the integrated cellular modem directly using telnet port 5000. If
PPP is enabled, you cannot access the integrated cellular modem.
Dial-on-Demand: Enable/disable Dial-on-Demand. The default is Disable. If you disable it, the router will always
stay connected unless the Idle Time Out expires. When Dial-on-Demandis enabled, use the
‘Wakeup on Call’ settings under the PPP menu to configure the settings for re-establishment
of the connection.
Idle Time Out: Set the amount of idle time that will pass before the router will timeout. The default is 180
seconds. If the time expires, the PPP connection to the Internet will disconnect. Any IP
packets from the LAN side or IP traffic from the wireless side will reset this timer and prevent
the connection from dropping.
Connect Time Out: Set the number of seconds to wait for a connection while in receive mode before timing out.
Dialing Max Retries: Enter the number of dialing retries allowed. The default is zero, which means an infinite
number is allowed. Range 0 to 100.
Authentication
Authentication Type: Set the authentication protocol type that will negotiate with the remote peer: pap/chap/pap-
chap. Default is pap-chap.
Username: Enter the Username with which the remote peer will authenticate. You can leave this field
blank, if desired. Username is limited to 60 characters.
Password: Enter the Password with which the remote peer will authenticate. You can leave this field
blank, if desired. Password is limited to 60 characters.
ICMP Keep Alive Check
Keep Alive Check: Enable/disable Keep Alive Check. The default is Disable. This is used to periodically check
that the Internet connection is up. If it is not, the router will try to reconnect.
Keep Alive Type: Select ICMP or TCP (the protocol type for Keep Alive).
Host Name: Enter the Host Name or IP Address for Keep Alive Check. No default.
TCP Port: Enter the TCP Port number to connect with the TCP server.
Interval: Set the number of seconds for Keep Alive Check. Default is 60 seconds.
ICMP Count: Set the number of ICMP Keep Alive Checks to be sent to the specified host. Default is 10.
Modem Configuration(Refer to the Customer Activation Notices included with the product for proper information
to enter).
Dial Number: Set the dial number to be dialed. Default is NULL.
For HSPA models, the Dial Number is *99***1#
For EVDO models, the Dial Number is #777
Dial Prefix: Set the modem dial prefix. The default is ATDT.
Connect String: Set the modem Connect String. The default is CONNECT.
APN: Enter the APN (Access Point Name). The APN is assigned by your wireless service provider.
Init String 1-4: Configure the modem init strings. You can set up to 4 modem initialization strings.
Baud Rate: The Baud Rate option is only displayed on certain models and is set at 230.4K, by default.
The default setting is set for maximum performance.
Submit Button
Click the Submit button to save these settings.
Note: You must click Save and Restart once you have completed and submitted all the screens on which you have made
changes.
28 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Chapter 3 – Using the Web Management Software
PPP > Wakeup-on-Call
The Wakeup-on-Call feature allows the router to wake up and initiate a connection when there is an incoming call or LAN
activity. If you desired some security with this feature, you can set up the router to wake up based on Caller ID or SMS instead
of allowing all incoming calls to wakeup the router. Dial-on-Demand in the IP Setup menu must be enabled for these settings
to have any affect. The Wakeup-on-Call feature will reduce the cost incurred when a router is online and available 24/7.
Note: When provisioning this feature, you must allow incoming calls, sms capability, and/or caller-id.
Wakeup-on-Call Configuration
Wakeup on Call: Enable/disable the Wakeup-on-Call feature. The default is Disable. Wakeup-on-Call occurs when a
ring or caller ID is detected. This will trigger the router to reconnect after the ‘Time Delay’ expires.
Time Delay: Enter the amount of time that you want to pass between the reception of a call and the initiation of
the Wakeup-on-Call connection. A time delay is needed to make sure that the incoming call has
ended before the connection is initiated. The default is 10 seconds.
Dial-on-Demand from LAN: The default is disable. When enabled, the router will reconnect when it sees IP traffic on
the LAN that is needed to be routed. If this feature is disabled, Dial-on-Demand initiates a PPP
connection to the Internet only from the WAN, not from the LAN.
Init Strings: Configure the router initialization string. This initialization string is specific to the installed integrated
cellular modem. Some initialization may be required for the integrated cellular modem to accept the
Wakeup-on-Call feature. Init-num can range from 1-5. The default is NULL. Refer to the following
table for examples of the Init String depending on model.
ModelInit 1Init 2Init 3Init 4
MTCBA-H3-EN3 AT+CNMI=1,1
,0,1,0
MTCBA-EV1-EN3 AT+CNMI=1,1
,0,1,0
AT+CNMA Ring, for any number/call to
AT+CLIP=1 AT+CNMA Ring, for any number/call to
Submit: Click the Submit to save these settings
Caller ID Configuration
Add “Wakeup on Call” Caller ID: To add Caller ID to the Wakeup-on-Call function, enter the Caller ID to be
allowed to wakeup the router. Enter ‘RING’ (all Caps) to wake up on any call.Enter a CID phone
number or an SMS message. The SMS message string must not contain any spaces between
words.
After entering the Caller ID, click the Add button. The Caller ID displays at the bottom of the screen.
You can enter any number of IDs you desire.
A Caller ID can be edited or deleted using Options, which will be available once a Caller ID is
displayed.
Ack Comment
trigger Wakeup-on-Call.
trigger Wakeup-on-Call.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 29
Chapter 3 – Using the Web Management Software
Caller Acknowledgement Configuration
Acknowledgement String to Caller: The configured string of (0 to 40 characters) will be sent to the integrated cellular
modem upon receiving a valid caller ID from the WAN. The default is NULL string.
Note: If the string is not configured, acknowledgement to the caller will not be sent upon successful
caller ID reception.
Submit
Click the SUBMIT button to save these settings.
Note: You must click Save and Restart once you have completed and submitted all the screens on which you have made
changes.
PPP > Wakeup-On-Call Examples
Example 1 – Determine if the router Is Supporting Incoming Calls and Caller ID
1. On the PPP > PPP Configuration screen, m ake sure that PPP is Disabled.
2. On the PPP > Wakeup-on-Call screen, make sure that Wakeup-on-Call is Disabled.
3. Open a command prompt by clicking the Start button and selecting Run.
4. Type CMD to open the command window. Click OK.
5. When the command window opens, telnet to the router.
Note: 5000 is the router port number.
5.1. Enter your username and password to login.
5.2. Enter an AT command to make sure you receive a response; i.e., OK.
5.3. On HSPA modlels, enter the Command AT+CNUM to determine the dial number of your router.
6. From another phone, call your router using the number identified in Step 5.3. This will let you know if the RING
message shows.
7. To enable Caller ID, enter the AT+CLIP=1 command on the command screen and make the call again to see if it
shows Caller ID information.
Notes:
● Step 5.3 must show the RING or CALLER ID information in order for the Wakeup-on-Call function to work.
● Some wireless providers might not provide caller ID information if you have only a data plan.
Example 2 – Set Up the Ethernet Router to Activate on ALL Incoming Calls
1. On the PPP >PPP Configuration screen, set up the following parameters:
PPP General
● Make sure that PPP is Enabled.
● Make sure Dial-on-Demand is Enabled.
● Set the Idle Time Out to the number of seconds you desire.
Authentication
● Your wireless service provider may require you to have a separate PPP Use name and Password. If so,
enter them here.
Note: If a username and password are required, your wireless provider would have given them to you when
you activated your account.
Modem Configuration
●Make sure your Dial Number is entered correctly:
For HSPA models, the Dial Number is *99***1#
For EV-DO models, the Dial Number is #777
Submit
●Click the Submit button to save the changes made on this screen.
2. On the PPP > Wakeup-on-Call screen, set up the following parameters:
Wakeup-on-Call Configuration
● Select Enable for Wakeup-on-Call.
● Set the Time Delay to 3 seconds. You can use the 10 second default.
● All Init Strings should be empty.
● Submit Button
Click the Submit button to save these settings.
Caller ID Configuration
● Enter the string RING to the Caller ID list.
● Click the Add Button to save the string to the Caller ID list.
3. Save and Restart
30 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Chapter 3 – Using the Web Management Software
Click Save and Restart once you have completed and submitted all the screens on which you have made
changes. The device will save all the settings and reboot the PC.
Example 3 – Set Up the Ethernet Router to Activate on Matching Caller IDs Only:
1. On the PPP > PPP Configuration screen, set up the following parameters:
PPP General
● Make sure that PPP is Enabled.
● Make sure Dial-on-Demand is Enabled.
● Set the Idle Time Out to the number of seconds you desire.
Authentication
● Your wireless service provider may require you to have a separate PPP username and password. If so,
enter them here.
Note: If a username and password are required, your wireless provider would have given them to you
when you activated your account.
Modem Configuration
●Make sure your Dial Number is entered correctly:
For HSPA models, the Dial Number is *99***1#
For EV-DO models, the Dial Number is #777
Submit
●Click the Submit button to save the changes made on this screen.
2. On the PPP > Wakeup-on-Call screen, set up the following parameters:
Wakeup-on-Call Configuration
● Select Enable for Wakeup-on-Call.
● Set the Time Delay. You can use the 10 second default.
● Enter the Init Strings:
Set Wakeup Init String 1 by entering AT+CLIP=1 for HSPA models only.
●Submit Button
Click the Submit button to save these settings.
Caller ID Configuration
● Enter a caller’s ID that you want added to the Caller ID list.
● Add Button
Click the Add button to save each Caller ID as it is entered to the Caller ID list.
3. Save and Restart
Click Save and Restart once you have completed and submitted all the screens on which you have made
changes. The device will save all the settings and reboot the PC.
PPP > Power-On Configuration
The Power-On Configuration feature allows you to set an initializatio n string that will be sent to the router upon boot up.
Power-On Init String Configuration
Power-On Init String: You can enter a string of 0 to 40 characters that will be sent to the router upon boot up. All
commands will initialize before you proceed with regular PPP related activity.
Note: When no initialization string is configured, regular functionality of the router is retained.
Submit: Click the SUBMIT button to save this setting.
Note: You must click Save and Restart once you have completed and submitted all the
screens on which you have made changes.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 31
Chapter 3 – Using the Web Management Software
PPP > Modem Commands
Setting up certain modem commands will allow an external application to query modem information (based on the commands
entered). The application can use the URL
HUHTTP://xxx.xxx.xxx.xxx/modeminfor.htmlUH to get the IP address that is currently
assigned to the integrated cellular modem after the PPP connection is established. It also will show the results of up to ten AT
commands entered here.
Modem AT Commands Configuration
These commands will be sent every time a PPP connection to the network is initiated.
Example of Useful HSDPA AT Commands:
AT+CGSN Product Serial Number
AT+CGMR Software Version
AT+CSQ Signal Quality
AT+CNUM Wireless Subscriber Number
AT+COPS? Network Information (Operator)
AT+CREG? Network Registration
Example of Useful EV-DO AT Commands:
AT+CGSN Product Serial Number
AT+CGMR Software Version
AT+CSQ Signal Quality
Notes:
● You can also retrieve the integrated cellular modem information without using a browser:
Make a TCP connection to port 80 (same as the Web Admin port) and send data as:
GET /atinfor.html HTTP/1.1
Then press Enter twice.
● Refer to the AT Command Reference Guides you downloaded from the Multi-Tech Website for other commands.
32 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Chapter 3 – Using the Web Management Software
Networks & Services
Networks & Services > Network Configuration
Networks or Hosts can be added here. The options to Delete or Edit a network after it has been defined and added are available
by using the table at the bottom of the screen.
Network Configuration
Enter the Name, IP Address, and Mask for a new Network or Host.
Notes:
● A Network/Host Name cannot be edited.
● A Network/Host cannot be deleted if it is used in another configuration.
● Network/Host changes are reflected in all the configurations in the Web Management software where they are
used.
●A Network/Host added here will be displayed in the following sections: Static Routes, DNAT, and Packet Filters.
Name: Enter the name of the Network/Host. The same address-mask pair should not already be present
in the displayed list. The Name is limited to 15 characters maximum.
IP Address: Enter the IP Address of the Network/Host. The same address-mask pair should not already be
present in the displayed list.
Subnet Mask: Enter the Network Mask of the Network/Host. For Host addresses, the mask is entered as 32.
Note: See Appendix A -- Table of Commonly Supported Subnets.
Add Button: Click the Add button. The defined network is added and will display at the bottom of the screen.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 33
Chapter 3 – Using the Web Management Software
Networks & Services > Service Configuration
On this screen you can specify the standard set of well known services available on the system. These services enable the
configuration of the user-defined services. The options to Delete or Edit a service after it has been defined and added are
available by using the table at the bottom of the screen.
Service Configuration
Enter the Name, Protocol, Source Port/Client, and Destination Port/Server for the new Service.
● A Service Name cannot be edited.
● A Service cannot be deleted if it is used in another configuration.
● Service changes are reflected in all the configurations in the Web Management software where they are used.
● Services added here will be displayed in the following sections: DNAT, Packet Filters.
Name: Enter the name of the Service which is limited to 16 characters. It has to be unique.
Protocol: Enter the type of protocol (TCP, UDP).
Source Port: Enter the Destination Port for this service. The source and destination ports can be entered either
as a single port or a range using a colon as the separator.
Destination Port: Enter the name of the Destination Port for the service.
Add Button: Click the Add button. The new service is added and will display on the screen.
34 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Chapter 3 – Using the Web Management Software
Packet Filters > Packet Filters
You can Delete or Edit a packet filter rule after it has been defined and added by using the table at the bottom of the screen.
Packet Filter
From (Host/Networks): Enter the network/host from which the packet must originate for the filter rule to match. The
Any option, which matches all IP addresses regardless of whether they are officially assigned
addresses or private addresses, may also be entered. The network/host must be pre-defined in the
Networks section.
Service: Enter the service that is to be matched with the filter rule. These services must be pre-defined in
the Services section. These services precisely define the traffic to be filtered.
To (Host/Networks): Enter the network/host to which the packet must send for the filter rule to match. The Any option,
which matches all IP addresses regardless of whether they are officially assigned addresses or
private addresses, may also be entered. The network/host must be pre-defined in the Networks
section.
Action: Enter the action that the packet filter executes if the rule matches any traffic traversing the firewall.
Types of actions defined are:
Accept: Allows/accepts all packets that match this rule.
Reject: Blocks all packets that match this rule. The host sending the packet will be informed
that the packet has been rejected.
Drop: Blocks all packets that match this rule, but the host is not informed; i.e., this is a silent
drop.
Log: Packets matching the rule; i.e., the corresponding source address, destination
address, and service will be logged.
Add Button: Click the Add button. The defined packet filter rule is added and will display at the bottom of the
screen.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 35
Chapter 3 – Using the Web Management Software
Packet Filters > DNAT Configuration
Destination Network Address Translation (DNAT) is a process that allows the placing of servers within the protected network
and making them available for a certain service to the outside world. The DNAT process running on the router translates the
destination addres s of incoming packe ts to the address of the real network server on the LAN. The packets are then forwarded.
You can Delete or Edit a DNAT rule after it has been defined and added by using the table at the bottom of the screen.
Important Note: When adding rules, at least one host must be defined in the Network Configuration section.
DNAT Configuration
Allow Access: Select a network or host to which IP packets will be allowed and re-routed. The network/host
must be pre-defined in the Network Configuration section.
External Service: Select the External Service that you want allowed. The service must be defined in the Service
Configuration section.
LAN IP: Select the LAN IP to which the packets are to be diverted. Only one host can be defined as the
destination.
Internal Service: Select the Internal Service to be the destination.
Internal Source: Select the source address for packets that are going to be sent. If you do not want to change the
address, select NOCHANGE.
Save Button: Click the Save button. The defined DNAT configuration is added and will display at the bottom of
the screen. Entries can be deleted or edited by clicking the Edit or the Delete buttons.
Packet Filters > DNAT Example
Set Up DNAT and Port Forwarding to an Internal Device
Note: The internal device can be camera, meter, security device, etc.
Situation: Assume the device is on a LAN with an IP address of 192.168.2.100 and the port to access the device is port
7700.
1. On the Network & Services > Network Configuration screen, set up the following parameters:
Name – Enter a name for the LAN device.
IP Address and Subnet Address – Enter the IP address and subnet address of the device.
Example: Name = MeterIP
IP Address = 192.168.2.100
Subnet Address = 255.255.255.255. The subn et mask in the network configuration is not
defined using x.x.x.x notation. It uses ‘bit ’ notation. So 255.255.255.255 = 32.
Add – Click the Add button to save this configuration.
2. On the Network & Services > Service Configuration screen,define a service name. For this example, the
service will be a meter.
Name – Enter a name for the service (use a name that will identify the service for you).
Example: MeterPort
Protocol – Select a protocol.
Example: tcp or udp
S-Port / Client – Enter the source port for this service.
Example: 1:65535
D-Port / Server – Enter the destination port for this service.
Example: 7700
Add – Click the Add button to save this configuration.
36 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Chapter 3 – Using the Web Management Software
Multi-Tech Systems, Inc. MultiModem rCell User Guide 37
Chapter 3 – Using the Web Management Software
3. On the Packet Filters > DNAT Configuration screen, define the DNAT rule.
Allow Access – Select the original target network/host of the IP packets that you now want rerouted. The
original target network/host is the one previously defined in the Network Configuration section.
Example: Any
External Service – Select the External Service that you want allowed. The service must be defined in the
Service Configuration section.
LAN IP – Select the LAN IP to which the packets are to be diverted. Only one host can be defined as the
destination.
Internal Service – Select the Internal Service to be the destination.
Pre DNAT Service – Select the service for the Pre-DNAT destination. This service was just defined in the
Service Configuration section.
Example: MeterPort
Post DNAT IP – Select the destination to which the IP packets are to be diverted. Only one host can be
defined as the Post DNAT destination.
Example: MeterIP
Post DNAT Service – Select the service for the Post DNAT configuration.
Example: MeterPort
Internal Source – Select the source address for packets that are going to be sent. If you do not want to
change the address, select NOCHANGE.
Example: NOCHANGE
4. Save – Click the Save button to save this configuration.
Note: You must click Save and Restart once you have completed and submitted all the screens on
which you have made changes. The device will save all the settings and reboot the PC.
38 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Chapter 3 – Using the Web Management Software
Packet Filters > Advanced
Connection Tracking
H323: Enable/disable the forwarding of H323 packets across the firewall.
PPTP: Enable/disable PPTP Packet Pass-through (PPTP NAT support).
Note: H323 and PPTP are disabled by default.
ICMP Configuration
The Internet Control Message Protocol (ICMP) is used to test the network connections and the functionality of the
firewall and is also used for diagnostic purposes. ICMP on Firewall and ICMP Forwarding always apply to all IP
addresses; i.e., Any. When these are enabled, all IP hosts can Ping the firewall (ICMP on Firewall) or the network
behind it (ICMP Forwarding).
ICMP on LAN: Enable/disable the transfer of ICMP packets on the LAN interface.
ICMP on WAN: Enable/disable the transfer of ICMP packets on the WAN interface.
ICMP Forward: Enable/disable the forwarding of ICMP packets through the firewall into the local network.
Note: ICMP on the Lan, Wan, and Forward are enabled by default.
Submit
Click the Submit button to save these settings.
Note: You must click Save and Restart once you have completed and submitted all the screens on which you have
made changes.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 39
Chapter 3 – Using the Web Management Software
GRE Tunnels
GRE tunneling and GRE routing together are referred to Generic Routing Encapsulation (GRE). GRE Routing is an integral
part of GRE tunneling. First, the GRE Tunnels are created using the GRE Tunnel Configuration. Then the routes for the remote
networks that are to be routed through a tunnel need to be specified in the GRE Routes Configuration. Thus, all the traffic
destined to remote networks associated to a tunnel will get routed through that tunn el.
GRE Tunnels > GRE Tunnels
Tunneling allows the use of a public network to convey data on behalf of two remote private networks. It is also a way to
transform data frames to allow them to pass networks with incompatible address spaces or even incompatible protocols. If you
want to read more about how this works, see the online Help.
GRE Tunnel Configuration
Tunnel Name: Enter a name for the new tunnel.
Local IP: Select the local interface on which the tunnel is being created. Eventually, the packets destined for
this tunnel will be routed through it.
Note: When adding a tunnel, use only one of the following: Remote IP or FQDN.
Remote IP: Select the Remote IP address that marks the other end point of the tunnel (this is the one to which
the routed packets will be received).
OR
FQDN: Enter the FQDN (Fully Qualified Domain Name) for the Remote IP, which can be either the IP
Address or an FQDN.
Add Button: Click the Add button. The defined GRE tunnel configuration is added and will display at the bottom
of the screen.
40 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Chapter 3 – Using the Web Management Software
GRE Tunnels > GRE Routes Configuration
GRE Routes Configuration
Remote Network:Select the remote network for which the traffic destined to it must be routed through the given
tunnel.
Tunnel Name: Select the name of the tunnel through which the traffic will be routed.
Note: To add a tunneled route, the remote network and the tunnel must have been defined in Network
Configuration. The tunnel configuration must be completed before setting the GRE route
configuration.
Add Button: Click the Add button. The defined GRE route configuration is added and will display at the
bottom of the screen.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 41
Chapter 3 – Using the Web Management Software
DHCP Server
DHCP Server > Subnet Settings
General Configuration
DHCP (Dynamic Host Configuration Protocol) is a protocol that allows individual devices on an IP network to get their
own network configuration information (IP address, subnet mask, broadcast address, etc.) from a DHCP server. The
overall purpose of DHCP is to make it easier to administer a large network.
DHCP: Enable/disable the DHCP server.
Subnet: Enter the subnet address. If you want to change the DHCP subnet address, you first have to
delete all the subnet settings below.
Mask: Enter the subnet mask.
Gateway: Enter the gateway address.
DNS: Enter the DNS address.
Lease Time: Select the DHCP Lease Time from the selection box. Lease time is set in days, hours, and
minutes. A Lease Time of 00-00-00 is an Infinite Lease Time.
Submit Click the Submit button to save these settings.
Note: You must click Save and Restart once you have completed and submitted all the screens
on which you have made changes.
Subnet Settings
From-To Range: Enter the range of IP addresses to be assigned by DHCP.
Add: Click the Add button. The address range is added and will display in the table at the bottom of
the screen. Once the range displays, you can delete if necessary.
Note: See Appendix A – A Table of Commonly Supported Subnets.
42 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Chapter 3 – Using the Web Management Software
DHCP Server > Fixed Addresses
DHCP Fixed Configuration
The DHCP server can be made to assign a fixed IP address for a particular user by identifying the MAC address. This
binding can be made permanent by configuring it here. The same IP address will not be used for any DHCP client with a
different MAC address, even if there is no active DHCP connection with that IP address.
MAC Address: Enter the MAC address to which the specified IP address binds.
IP Address: Enter the fixed IP address to be assigned.
Add: Click the Add button. The addresses are added and will display in the table at the bottom of the
screen from where they can be deleted or changed.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 43
Chapter 3 – Using the Web Management Software
IPSec
The IPSec (IP Security) protocol suite, based on modern cryptographic technologies, provides security services like encryption
and authentication at the IP network layer. It secures the whole network traffic providing guaranteed security for any
application using the network. It can be used to create private secured tunnels between two hosts, two security gateways, or a
host and a security gateway. Up to three tunnels can be active at any given time. Beyond three active tunnels can be saved, but
they will not be active.
IPSec provides encryption and authentication services at the IP level of the protocol stack. IPSec can protect any traffic carried
over IP.
IPSec provides the following services:
● Authentication only
● Encryption only
Authentication and encryption
Transmitting and receiving data securely over an unprotected network involves deciding on the type of IPSec service, as
mentioned above, required for the connection, establishing a secure connection by a key exchange process and transferring data
using that connection.
The key exchange process is done in one of two ways:
● Manual Keying where the authentication and encryption keys are provided manually on both sides of the connection.
● Auto Keying using IKEv2 Protocol where the authentication and encryption keys are generated on either side of the
connection and exchanged by different methods.
IPSec > IPSec
IPSec
VPN Status Check the VPN Status checkbox to enable IPSec. Click the Save button.
Add a New Connection
Add IKE Connection Click the Add IKE Connection button. A screen displays for setting up an IKE connection.
Add Manual Connection Click the Add Manual Connection button. A separate screen displays for setting up a
manual connection.
44 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Add IKE Connection
Chapter 3 – Using the Web Management Software
Add an IKE Connection
Connection Name Enter a text name that will identify the connection for you.
Compression Check the compression checkbox to enable IPCOMP, the compression
algorithm.
Perfect Forward Secrecy (PFS) Check the PFS checkbox to enable PFS, a concept in which the newly
generated keys are unrelated to the older keys). This is enabled by default.
Authentication Method Authentication can be done using Pre-Shared Secrets.
Pre-Shared Key The Pre-Shared Key must be agreed upon and shared by the VPN
endpoints; it must be configured at both endpoints of the tunnel.
Select Encryption Select the encryption method. 3DES is recommended. Optio ns include:
3DES, AES-128, AES-192, AES-256
IKE Life Time The duration for which the ISAKMP SA should last is from successful
negotiation to expiration. The default value is one hour and the maximum is
8 hours.
Key Life The duration for which the IPSec SA should last is from successful
negotiation to expiration. The default value is one hour and the maximum is
24 hours.
Number of Retries Specify the number of retries for the IPSec tunnel. Enter zero for unlimited
retries.
Local WAN IP This is the interface initiating the IPSec tunnel.
Local LAN Internal subnet of the local security gateway for which the security services
should be provided. If the router acts as a host, this should be configured as
None.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 45
Chapter 3 – Using the Web Management Software
Remote Gateway IP Interface where the IPSec tunnel ends. In the case of a Road Warrior with a
Dynamic IP address, this should be configured to ANY.
FQDN FQDN is a Fully Qualified Domain Name that resolves to the Local Wan IP
of the router or in the case of GRE/IPSEC, it is used to identify the Wan IP
of the remote location. This is provided by your ISP or created by you if you
are using a Dynamic DNS service. When FQDN is selected, the Remote
Gateway IP should be left blank.
Remote LAN Internal subnet of the remote security gateway for which the security
services should be provided. If the remote en d is the host, this should be
configured as None.
UID (Unique Identifier String) Check the UID box to enable the Local ID and Remote ID. Local ID and
Remote ID are active only when UID is enabled.
Local ID
Enter a string identifier for the local security gateway.
Remote ID
Enter a string identifier for the remote security gateway.
NetBIOS Broadcast Check this option to enable broadcasts over the connection. It will allow
computers on the network to share Microsoft file and printer sharing
information.
Save Button
Click the Save button to save these settings.
46 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Add Manual Connection
Chapter 3 – Using the Web Management Software
Add a Manual Connection
Connection Name Enter a text name that will identify the connection for you.
Compression Check the compression checkbox to enable IPCOMP, the compression algorithm.
Authentication Method Select the authentication algorithms to be used for the respective security services. Options are: MD5-96 and SHA1-96.
Authentication Key The VPN firewall could use either MD5-96 or SHA1-96 for authentication. For example,
MD5-96 could have a key of abcdefgh12345678.
Authentication
Protocol
SHA1-96 Must be 20 characters Alphanumeric characters
MD5-96 Must be 16 characters Alphanumeric characters
Encryption Key The router can use any one of the methods specified in its encryption algorithm. For
example 3DES uses 24 alphanumeric characters (192 bits) as its encryption key.
Example: 1234567890abcdefabcdabcd
Encryption
Protocol
Null Must be 24 characters Alphanumeric Characters
3DES Must be 24 characters Alphanumeric Characters
AES-128 Must be 16 characters Alphanumeric Characters
AES-192 Must be 24 characters Alphanumeric Characters
AES-256 Must be 32 characters Alphanumeric Characters
Key LengthAccepted Characters
Key Length Accepted Characters
SPI Base The Security Parameter Index identifies a manual connection. The SPI is a unique
Multi-Tech Systems, Inc. MultiModem rCell User Guide 47
identifier in the SA (Secure Association – a type of secure connection) that allows the
receiving computer to select the SA under which a packet will be processed. The SPI
Base is a number needed by the manual keying code. Enter any 3-digit hexadecimal
number, which is unique for a security association. It should be in the form 0xhex
Chapter 3 – Using the Web Management Software
(0x100 through 0xfff is recommended). If you have more than one manual connection,
then the SPI Base must be different for each one.
Left Next Hop Next Hop is the address of the next device in a routing table’s path that moves a packet
to it’s destination. This setting can be configured or left as a static value: 0.0.0.0. When
not configured, the value is set to the Gateway of the Box/Gateway configured on the
Interface/Right IP. The selection is based on the Left and Right IP.
Local WAN IP Select the Interface to initiate the IPSec tunnel (Left Security Gateway).
Local LAN Select the internal subnet of the local security gateway for which the security services
are to be provided. If the router acts as a host, this should be configured as None. Other
options are: Any, LAN, LAN Interface, WAN 1, WAN 1 Interface.
Remote Gateway IP Select the interface in which the IPSec tunnel ends. In the case of Road Warriors with a
Dynamic IP addresses, this should be configured as ANY. Other options inclu de: LAN ,
LAN Interface, WAN 1, WAN 1 Interface, and None.
FQDN FQDN is a Fully Qualified Domain Name that resolves to the Local Wan IP of the
router or in the case of GRE/IPSEC, it is used to identify the Wan IP of the remote
location. This is provided by your ISP or created by you if you are using a Dynamic
DNS service. When FQDN is selected, the Remote Gateway IP should be left blank.
Remote LAN This is the internal subnet of the remote security gateway for which the security
services are to be provided. If the remote end is a host, this should be configured as None.
NetBIOS Broadcast Check this option to enable broadcasts over the connection. It will allow computers on
the network to share Microsoft file and printer sharing information.
Save Button
Click the Save button to save these settings.
48 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Tools
Tools > Tools
DDNS
DDNS Force Update: Click the Update button to update the DDNS server with your current dynamically assigned IP
address.
DDNS Status: Click the Refresh button to display the DDNS Status after a forced update.
Modem
Reset Modem: Click the Reset button to reset the integrated cellular modem.
Tools > Firmware Upgrade
Chapter 3 – Using the Web Management Software
Firmware Upgrade
The firmware for the router can be upgraded to the latest version using this feature. All Multi-Tech firmware upgrades are
posted on the Multi-Tech Web site from which they can be downloaded.
Note: Before you upgrade your firmware, you should save your present configuration. After the firmwa re upgrade is
complete, you should verify your configuration to ensure that it is as expected. Particularly, check that the DHCP scope
settings are set properly. Also, up to four IPSEC tunnels can be active at any given time. Beyond four active tunnels can
saved, but they will not be active.
Browse File for Upgrade: Click the Browse button and locate the latest firmware version to be downloaded. Select the
mtcba-EN3-u-xxx.bin file. Highlight the file name and press Enter so that the file name displays in the text box. Make
sure you select the correct BIN file; otherwise, your router can become inoperable. Then click the Upgrade button.
When upgrade is completed, the program will return to the main login screen.
Important Notes:
● The new firmware is written into the flash.
● A Firmware Upgrade will take at least 4 minutes while the firmware is downloaded. Do not cycle power during this
time.
●DO NOT perform firmware upgrade remotely via the Cellular wireless connection.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 49
Chapter 3 – Using the Web Management Software
Tools > Load Configuration
Load Configuration
Browse File for Load Configuration: Click the Browse button to open the file that allows you to locate the configuration
file. When found, highlight the file name and press Enter so that the file name displays in the text box. Then click the Load
button.
Important Notes:
● The new configuration is written into the flash.
● A Configuration Upgrade will take at least 3 seconds to download and 60 seconds to install the settings and
reboot. Reboot happens automatically.
When you click the Load button, the following screen displays. It shows the name of the file you selected.
Click the Find, Save, or Cancel buttons as desired. The More Info displays Microsoft’s Internet Explorer Help on
downloading files.
Tools > Save Configuration
Click this option to save the configuration.
50 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Statistics & Logs
Statistics & Logs > System Information
Chapter 3 – Using the Web Management Software
This is an example of the Statistics & Logs System Information
Multi-Tech Systems, Inc. MultiModem rCell User Guide 51
Chapter 3 – Using the Web Management Software
Statistics & Logs > Ethernet
This is an example of the Ethernet Statistics & Logs screen. It shows Ethernet statistics.
52 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Statistics & Logs > PPP
Chapter 3 – Using the Web Management Software
This is an example of the PPP Statistics & Logs screen. It shows PPP statistics when PPP is enabled.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 53
Chapter 3 – Using the Web Management Software
Statistics & Logs > PPP Trace
This is an example of the PPP Trace Statistics & Logs screen. It shows the PPP trace messages.
Statistics & Logs > DHCP Statistics
This is an example of the DHCP Statistics & Logs screen. It shows the statistics of DHCP leases.
Statistics & Logs > GRE Statistics
This screen displays the statistics of active tunnels.
54 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Statistics & Logs > Modem Information
This screen displays the modem commands set on the PPP > Modem Commands screen and also displays the
results of the commands.
Statistics & Logs > Service Status
This screen displays the summary of the service status.
Statistics & Logs > TCP/UDP Client Live Log
Chapter 3 – Using the Web Management Software
This screen displays the TCP/UDP Client Live Log.
Statistics & Logs > TCP/UDP Server Live Log
This screen displays the TCP/UDP Server Live Log.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 55
Chapter 3 – Using the Web Management Software
Statistics & Logs > IPSec Live Log
This screen displays the IPSec Live Log.
Statistics & Logs > IPSec Log Traces
This screen displays the IPSec Log Traces.
56 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Appendix A – Commonly Supported
Subnets Reference Table
This table lists commonly supported Subnets organized by Address.
255.255.255.128 N.N.N.0 N.N.N.1-126 N.N.N.127
/25 N.N.N.128 N.N.N.129-254 N.N.N.255
Network Number Hosts Available Broadcast Address
255.255.255.192 N.N.N.0 N.N.N.1-62 N.N.N.63
/26 N.N.N.64 N.N.N.65-126 N.N.N.127
N.N.N.128 N.N.N.129-190 N.N.N.191
N.N.N.192 N.N.N.193-254 N.N.N.255
Network Number Hosts Available Broadcast Address
58 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Appendix B – Regulatory Compliance
EMC, Safety, and R&TTE Directive Compliance
The CE mark is affixed to this product to confirm compliance with the following European Community Directives:
Council Directive 2004/108/EC of 15 December 2004 on the approximation of the laws of Member States relating to
electromagnetic compatibility;
and
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical
equipment designed for use within certain voltage limits;
and
Council Directive 1999/5/EC of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual
recognition of their conformity.
FCC Part 15 Class B Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to 47 CFR Part 15
regulations. The stated limits in this regulation are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
● Reorient or relocate the receiving antenna.
● Increase the separation between the equipment and receiver.
● Plug the equipment into an outlet on a circuit different from that to which the receiver is connected.
● Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the CFR 47 rules. Operation of this device is subject to the following conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference that may cause undesired operation.
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
Industry Canada
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Reglement Canadien sur le matériel brouilleur.
Multi-Tech Systems, Inc. MultiModem rCell User Guide 59
Appendix C – Environmental
Information
July, 2005
aste Electrical and Electronic Equipment (WEEE)
W
The WEEE directive places an obligation on EU-based manufacturers, distributors, retailers and importers to take-back
electronics products at the end of their useful life. A sister Directive, ROHS (Restriction of Hazardous Substances)
complements the WEEE Directive by banning the presence of specific hazardous substances in the products at the design
phase. The WEEE Directive covers all Multi-Tech products imported into the EU as of August 13, 2005. EU-based
manufacturers, distributors, retailers and importers are obliged to finance the costs of recovery from municipal collection
points, reuse, and recycling of specified percentages per the WEEE requirements.
Instructions for Disposal of WEEE by Users in the European Union
The symbol shown below is on the product or on its packaging, which indicates that this product must not be disposed of with
other waste. Instead, it is the user’s responsibility to dispose of their waste equipment by handing it over to a designated
collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your
waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that
protects human health and the environment. For more information about where you can drop off your waste equipment for
recycling, please contact your local city office, your household waste disposal service or where you purchased the prod uct.
REACH Statement
Registration of Substances:
After careful review of the legislation and specifically the definition of an “article” as defined in EC Regulation 1907/2006,
Title II, Chapter 1, Article 7.1(a)(b), it is our current view Multi-Tech Systems, Inc. products would be considered as “articles”.
In light of the definition in § 7.1(b) which requires registration of an article only if it contains a regulated substance that “is
intended to be released under normal or reasonable foreseeable conditions of use,” our analysis is that Multi-Tech Systems,
Inc. products constitute nonregisterable articles for their intended and anticipated use.
Substances of Very High Concern (SVHC):
Per the candidate list of Substances of Very high Concern (SVHC) published October 28, 2008 we have reviewed these
substances and certify the Multi-Tech Systems, Inc. products are compliant per the EU “REACH” requirements of less than
0.1% (w/w) for each substance.
If new SVHC candidates are published by the European Chemicals Agency, and relevant substances have been confirmed, that
exceeds greater than 0.1% (w/w), Multi-Tech Systems, Inc. will provide updated compliance status.
Multi-Tech Systems, Inc. also declares it has been duly diligent in ensuring that the products supplied are compliant through a
formalized process which includes collection and validation of materials declarations and selective materials analysis where
appropriate. This data is controlled as a part of a formal quality system and will be made available upon request.
60 Multi-Tech Systems, Inc. MultiModem rCell User Guide
Appendix C – Environmental Inf ormation
Restriction of the Use of Hazardous Substances (RoHS)
Multi-Tech Systems, Inc.
Certificate of Compliance
2002/95/EC
Multi-Tech Systems, Inc. confirms that this product now complies with the chemical concentration limitations set forth in the
directive 2002/95/EC of the European Parliament (Restriction Of the use of certain Hazardous Substances in electrical and
electronic equipment - RoHS)
These Multi-Tech Systems, Inc. products do not contain the following banned chemicals:
Lead, [Pb] < 1000 PPM