Multi-Tech Systems, Inc. makes no representations or warranties, whether express, implied or by estoppels, with respect to the content, information,
material and recommendations herein and specifically disclaims any implied warranties of merchantability, fitness for any particular purpose and noninfringement.
Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of
Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.
Trademarks and Registered Trademarks
MultiTech, and the MultiTech logo, DeviceHQ, and MultiConnect are registered trademarks and Conduit is a trademark of Multi-Tech Systems, Inc. All other
products and technologies are the trademarks or registered trademarks of their respective holders.
Legal Notices
The MultiTech products are not designed, manufactured or intended for use, and should not be used, or sold or re-sold for use, in connection with
applications requiring fail-safe performance or in applications where the failure of the products would reasonably be expected to result in personal injury or
death, significant property damage, or serious physical or environmental damage. Examples of such use include life support machines or other life
preserving medical devices or systems, air traffic control or aircraft navigation or communications systems, control equipment for nuclear facilities, or
missile, nuclear, biological or chemical weapons or other military applications (“Restricted Applications”). Use of the products in such Restricted
Applications is at the user’s sole risk and liability.
MULTITECH DOES NOT WARRANT THAT THE TRANSMISSION OF DATA BY A PRODUCT OVER A CELLULAR COMMUNICATIONS NETWORK WILL BE
UNINTERRUPTED, TIMELY, SECURE OR ERROR FREE, NOR DOES MULTITECH WARRANT ANY CONNECTION OR ACCESSIBILITY TO ANY CELLULAR
COMMUNICATIONS NETWORK. MULTITECH WILL HAVE NO LIABILITY FOR ANY LOSSES, DAMAGES, OBLIGATIONS, PENALTIES, DEFICIENCIES, LIABILITIES,
COSTS OR EXPENSES (INCLUDING WITHOUT LIMITATION REASONABLE ATTORNEYS FEES) RELATED TO TEMPORARY INABILITY TO ACCESS A CELLULAR
COMMUNICATIONS NETWORK USING THE PRODUCTS.
The MultiTech products and the final application of the MultiTech products should be thoroughly tested to ensure the functionality of the MultiTech
products as used in the final application. The designer, manufacturer and reseller has the sole responsibility of ensuring that any end user product into
which the MultiTech product is integrated operates as intended and meets its requirements or the requirements of its direct or indirect customers.
MultiTech has no responsibility whatsoever for the integration, configuration, testing, validation, verification, installation, upgrade, support or maintenance
of such end user product, or for any liabilities, damages, costs or expenses associated therewith, except to the extent agreed upon in a signed written
document. To the extent MultiTech provides any comments or suggested changes related to the application of its products, such comments or suggested
changes is performed only as a courtesy and without any representation or warranty whatsoever.
Contacting MultiTech
Knowledge Base
The Knowledge Base provides immediate access to support information and resolutions for all MultiTech products. Visit http://www.multitech.com/kb.go.
Support Portal
To create an account and submit a support case directly to our technical support team, visit: https://support.multitech.com.
Related Documentation .............................................................................................................................................. 6
Chapter 2 – Specifications and Hardware Information ............................................................................................. 7
Connectors and LEDs..................................................................................................................................................... 9
Resetting the Device ................................................................................................................................................. 10
Power Measurements................................................................................................................................................. 10
Chapter 3 – Safety Information .............................................................................................................................. 11
Power Supply Caution ................................................................................................................................................. 11
General Safety............................................................................................................................................................. 11
Radio Frequency (RF) Safety ....................................................................................................................................... 12
Sécurité relative aux appareils à radiofréquence (RF).............................................................................................. 12
Interference with Pacemakers and Other Medical Devices ...................................................................................... 13
UL Notice .................................................................................................................................................................... 14
Spécifications UL ...................................................................................................................................................... 14
User Responsibility...................................................................................................................................................... 14
Example Labels............................................................................................................................................................ 15
Chapter 5 – Setting Up Hardware........................................................................................................................... 16
Installing a SIM Card ................................................................................................................................................... 16
Removing a SIM Card ................................................................................................................................................ 16
Cabling the Device....................................................................................................................................................... 16
Chapter 6 – Getting Started with mLinux Models................................................................................................... 17
Accessing the Terminal Interface ................................................................................................................................ 17
MultiConnect®ConduitTMAP MTCAP User Guide for Sprint3
CONTENTS
Setting Time Zone, Time, and Date............................................................................................................................. 17
Setting the Custom IP Address, Network Information, and Ethernet Internet Access .............................................. 18
Configuring the Cellular Connection ........................................................................................................................... 18
Starting Cellular Connection on Boot ......................................................................................................................... 19
Configuring the LoRa Network Server for mLinux ...................................................................................................... 21
Additional LoRa and mLinux Information ................................................................................................................... 22
Chapter 7 – Mounting the Device........................................................................................................................... 23
Mounting the Device................................................................................................................................................... 23
You will need............................................................................................................................................................. 23
Determining Location for the MTCAP....................................................................................................................... 23
Mounting the MTCAP ............................................................................................................................................... 24
47 CFR Part 15 Regulation Class B Devices ................................................................................................................. 26
Industry Canada Class B Notice................................................................................................................................... 26
Industry Canada ........................................................................................................................................................ 27
Waste Electrical and Electronic Equipment Statement .............................................................................................. 27
Registration of Substances........................................................................................................................................ 27
Substances of Very High Concern (SVHC) ................................................................................................................ 28
Restriction of the Use of Hazardous Substances (RoHS) ............................................................................................ 28
Information on HS/TS Substances According to Chinese Standards ......................................................................... 29
Information on HS/TS Substances According to Chinese Standards (in Chinese) .................................................... 30
4MultiConnect®ConduitTMAP MTCAP User Guide for Sprint
PRODUCT OVERVIEW
Chapter 1 – Product Overview
Overview
MultiConnect Conduit AP (MTCAP) connects thousands of IoT assets to the cloud using the LoRaWAN®protocol. It
expands LoRa network coverage to difficult to reach areas and is capable of packet forwarding user data between
LoRa end points and a centrally located network server on the cloud, in a data center, or a public network.
Note: Check for an updated version of this document at https://www.multitech.com/brands/multiconnect-
conduit-ap/.
Product Build Options
ProductDescription
MTCAP-LSP3-915-001LMultiConnect Conduit Access Point with LTE Cat 1, LoRa 915 MHz and
mLinux
Note:
The complete product code may end in .Rx, where R is revision and x is the revision number. For
example, MTCAP-LSP-915-001L-R1.
Package Contents
Your device ships with the following:
1 – MTCAP
1 – 5 Volt, 2.5 Amp Power supply
1 – RJ45 Ethernet cable
1 – Quick Start
Important: Contact MultiTech Systems if a replacement power supply is needed. Using a different power
supply may damage the device and voids the warranty.
Documentation Overview
The following documents are available at http://www.multitech.com/brands/multiconnect-conduit-ap. Select your
model to find the documents specific for that device.
DocumentDescriptionPart Number
MultiConnect Conduit AP MTCAP
User Guide for Sprint
MultiConnect Conduit AP MTCAP for
mLinux Quick Start
This document. Hardware, regulatory, and
getting started information.
Steps for getting started with mLinux
models. Ships with the device and is
available online.
S000704
82102350L
MultiConnect®ConduitTMAP MTCAP User Guide for Sprint5
PRODUCT OVERVIEW
DocumentDescriptionPart Number
Telit LE920x4/LE910Cx Series AT
Commands Reference Guide
For LSP3 devices, lists AT Commands and
parameters used to communicate with
80490ST10778A Rev. 4
your device.
Related Documentation
This manual provides the basics for getting started with mLinux or AEP. For addition information, visit our
developer site at http://multitech.net and select Software > mLinux.
6MultiConnect®ConduitTMAP MTCAP User Guide for Sprint
SPECIFICATIONS AND HARDWARE INFORMATION
Chapter 2 – Specifications and Hardware Information
Dimensions
MultiConnect®ConduitTMAP MTCAP User Guide for Sprint7
UL listed at 40° C, limited by AC power supply. Product has been tested to +70° C excluding power supply.
8MultiConnect®ConduitTMAP MTCAP User Guide for Sprint
SPECIFICATIONS AND HARDWARE INFORMATION
Connectors and LEDs
Note: Some features are available only on select models. The above image shows the model with all features.
For models that don't have a cellular radio, the chassis will not have a SIM slot.
ItemDescription
Connectors
Power5 Volt power jack.
EthernetRJ45 Ethernet jack.
ResetReset button. Reboots device or restores factory defaults. Refer to Resetting the Device for
details.
WPSReserved for future use.
SIMCellular models only. SIM slot. Refer to Installing SIM Card for details.
LEDs
STATUSBlinks when operating system is fully loaded.
LORALights when LoRa software is active.
CELLCellular models only. Lights when there is power to the radio. Blinks when the SIM is registered
with the carrier.
WIFIReserved for future use.
Ethernet LinkLeft LED on the Ethernet connector. Blinks when data is sent or received on the Ethernet link.
Steady light when there is a valid Ethernet connection.
Ethernet Speed Right LED on the Ethernet connector. Lit when the Ethernet is linked at 100 Mbps. If not lit, the
Ethernet is linked at 10 Mbps.
MultiConnect®ConduitTMAP MTCAP User Guide for Sprint9
SPECIFICATIONS AND HARDWARE INFORMATION
Resetting the Device
You need:
A pin, paperclip, or similar thin object that can fit into the reset hole
To reset the device:
1.Find the hole labeled RESET. The reset button is recessed into the case.
2.Use the pin to press and release the RESET button as follows:
Reset options:
To reboot, press RESET for less than 3 seconds.
To reboot and restore user-defined defaults (if previously set), press RESET for 3 to 29
seconds.
To reboot, restore factory settings, and erase user-defined defaults, press RESET for 30
seconds or longer.
The device restarts in commissioning mode. The system automatically removes all user
accounts.
Enter a new username and password to create your new administrative account. (Refer to
User Accounts for more details on username and password requirements.)
Note: The device reboots when restoring settings.
Power Measurements
MTCAP-LSP3-915
Note:
Multi-Tech Systems, Inc. recommends that you incorporate a 10% buffer into the power source
when determining product load.
Maximum Power: The continuous current during maximum data rate with the radio transmitter at
maximum power.
Tx Pulse: The average peak current during a GSM850 transmission burst period or HSDPA/LTE
connection. The transmission burst duration for GSM850 can vary, depending on what transmission
scheme is being deployed (GPRS Class 8, Class 10, GSM, etc.).
Inrush Charge: The total inrush charge at power on.
Radio ProtocolLive
Connection
(SIM Installed)
No Data
Cellular Call
Box
Connection,
No Data
Average
Measured
Current at
Maximum
Power
TX Pulse (AVG)
Amplitude
Current for
GSM850 or Peak
Current for
HSDPA/LTE
Total Inrush
Charge
Measured in
Millicoulomb
s
Total
Inrush
Charge
DURATIO
N during
Powerup
(INRUSH
Duration)
5.0 Volts
LTE168 mA268 mA1.06 A1.19 A1.57 MC1.61 mS