Multiquip GBP, GBS, GBWE, GBHM, BGMP User Manual

...
OPERATION AND PARTS MANUAL
GLOBUG SERIES
MODELS:
GBW/GBWE (Pentapod With Lamp)
GBP (Lamp Only)
GBHM (Hitch Mount Accessory)
GBMP (Mounting Plate)
ORIGINAL COPY
Revision #0 (07/23/09)
To fi nd the latest revision of this
publication, visit our website at:
www.multiquip.com
THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
PROPOSITION 65 WARNING
PAGE 2 — GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09)
TABLE OF CONTENTS
GBW/GBWE/GBS/GBP/ GBHM/GBMP Lighting System
Proposition 65 Warning ........................................... 2
Table Of Contents .................................................... 3
Parts Ordering Procedures ...................................... 4
Specifi cations ........................................................ 10
Dimensions (GBW/GBWE) .................................... 11
Dimensions (GBS) ................................................. 12
Dimensions (GBP) ................................................. 13
Footcandle Plot ...................................................... 14
General Information ............................................... 15
Components ..................................................... 16-17
Setup ................................................................ 18-22
Operation .......................................................... 23-25
Maintenance ..................................................... 26-31
Wiring Diagram ...................................................... 32
Explanation Of Code In Remarks Column............. 34
Suggested Spare Parts ......................................... 35
Component Drawings
Nameplates And Decals (GBW/GBWE) ........... 36-37
Nameplates And Decals (GBS) ........................ 38-39
Balloon And Lamp Assy (GBW/GBWE/GBS) ... 40-41
Mast Assy (GBW/GBWE) ................................. 42-43
Pentapod Assy (GBW/GBWE).......................... 44-45
Pole Assy (GBS) ............................................... 46-47
Hitch Mount Assy (GBHM) ............................... 48-49
Plate Mount Assy (GBMP) ................................ 50-51
Terms And Conditions Of Sale — Parts ................ 52
NOTICE
Specifi cations and part numbers are subject to change without notice.
GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09) — PAGE 3
PARTS ORDERING PROCEDURES
www.multiquip.com
Ordering parts has never been easier!
Choose from three easy options:
January 1
Effective:
st
, 2006
Best Deal!
Order via Internet (Dealers Only):
Order parts on-line using Multiquip’s SmartEquip website!
View Parts Diagrams
Order Parts
Print Specifi cation Information
Goto www.multiquip.com and click on
Order Parts
Order via Fax (Dealers Only):
All customers are welcome to order parts via Fax. Domestic (US) Customers dial: 1-800-6-PARTS-7 (800-672-7877)
Non-Dealer Customers: Contact your local Multiquip Dealer for parts or call 800-427-1244 for help in locating a dealer near you.
to log in and save!
Order via Phone:
If you have an MQ Account, to obtain a Username and Password, E-mail us at: parts@multiquip.
com.
To obtain an MQ Account, contact your District Sales Manager for more information.
Use the internet and qualify for a 5% Discount on Standard orders for all orders which include complete part numbers.*
Note: Discounts Are Subject To Change
Fax your order in and qualify for a 2% Discount on Standard orders for all orders which include complete part numbers.*
Note: Discounts Are Subject To Change
Domestic (US) Dealers Call:
1-800-427-1244
International Customers should contact their local Multiquip Representatives for Parts Ordering information.
PAGE 4 — GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09)
When ordering parts, please supply:
Dealer Account NumberDealer Name and AddressShipping Address (if different than billing address)Return Fax NumberApplicable Model NumberQuantity, Part Number and Description of Each Part
NOTICE
All orders are treated as Standard Orders and will
ship the same day if received prior to 3PM PST.
WE ACCEPT ALL MAJOR CREDIT CARDS!
Specify Preferred Method of Shipment:UPS/Fed Ex ✓ DHL
Priority One ✓ Truck
Ground
Next Day
Second/Third Day
SAFETY INFORMATION
Do not operate or service the equipment before reading the entire manual. Safety precautions should be followed at all times when operating this equipment. Failure to read and understand the safety messages and operating instructions could result in injury to yourself and others.
SAFETY MESSAGES
The four safety messages shown below will inform you about potential hazards that could injure you or others. The safety messages specifi cally address the level of exposure to the operator and are preceded by one of four words:
DANGER, WARNING, CAUTION or NOTICE.
SAFETY SYMBOLS
DANGER
Indicates a hazardous situation which, if not avoided,
WILL result in DEATH or SERIOUS INJURY.
WARNING
Potential hazards associated with the operation of this equipment will be referenced with hazard symbols which may appear throughout this manual in conjunction with safety messages.
Indicates a hazardous situation which, if not avoided,
COULD result in DEATH or SERIOUS INJURY.
CAUTION
Indicates a hazardous situation which, if not avoided, COULD result in MINOR or MODERATE INJURY.
NOTICE
Addresses practices not related to personal injury.
GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09) — PAGE 5
SAFETY INFORMATION
GENERAL SAFETY
CAUTION
NEVER operate this equipment without proper protective
clothing, shatterproof glasses, respiratory protection, hearing protection, steel-toed boots and other protective devices required by the job or city and state regulations.
NEVER operate this equipment when not feeling well due to fatigue, illness or when under medication. NEVER operate this equipment under the infl uence of drugs or alcohol.
ALWAYS check the equipment for loosened threads or bolts before starting.
DO NOT use the equipment for any purpose other than its intended purposes or applications.
NOTICE
This equipment should only be operated by trained and qualifi ed personnel 18 years of age and older.
Whenever necessary, replace nameplate, operation and safety decals when they become diffi cult read.
Manufacturer does not assume responsibility for any accident due to equipment modifi cations. Unauthorized equipment modifi cation will void all warranties.
NEVER use accessories or attachments that are not recommended by Multiquip for this equipment. Damage to the equipment and/or injury to user may result.
ALWAYS know the location of the nearest fi re extinguisher.
ALWAYS know the location of the nearest fi rst aid kit.
ALWAYS know the location of the nearest phone or keep a phone on the job site. Also, know the phone numbers
of the nearest ambulance, doctor and fi re department. This information will be invaluable in the case of an emergency.
PAGE 6 — GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09)
SAFETY INFORMATION
LIGHTING SYSTEM SAFETY
DANGER
NEVER use lighting system in rain, snow or
areas of high humidity that could generate electrical storms.
WARNING
NEVER disconnect any emergency or safety devices.
These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death. Disconnection of any of these devices will void all warranties.
CAUTION
NEVER attempt service on a running machine.
NOTICE
To prevent the lighting system from overturning, NEVER use in winds that exceed 22 mph (10 m/s).
The lighting system should only be used in temperatures between 23° to 104°F (-5° to 40° C). Failure to comply with these operating parameters could cause the lamp to malfunction and shorten the ballast life.
ALWAYS keep the lighting system in proper running condition.
Fix damage to lighting system and replace any broken parts immediately.
LAMP SAFETY
WARNING
NEVER attempt to replace lamp with the power on.
Always unplug the power cord from the generator or power source when changing the lamp.
ALWAYS allow a suffi cient amount of time for the lamp to cool before changing. The possibility exists of severe burns.
CAUTION
NEVER use force when installing the lamp. Excessive force
could cause the lamp to break, causing bodily harm.
NOTICE
NEVER leave any grease or oil residue on lamp surface when replacing or removing lamp. This can create hot spots, reducing the service life of the lamp.
ALWAYS make sure lamp surface is clean and dry.
ALWAYS replace with MQ recommended type lamp. See
parts section of this manual.
If applicable, ALWAYS make sure the lamp guard is installed correctly. NEVER deform the lamp guard.
NEVER unplug the lamp’s AC power cable during operation.
ALWAYS have a trained technician to install and remove lamp or replace any damaged fi xture wiring.
ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and unauthorized personnel.
GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09) — PAGE 7
SAFETY INFORMATION
BALLOON SAFETY
WARNING
To prevent serious burns, NEVER touch or unzip the balloon envelope when the lamp is on.
CAUTION
ALWAYS keep the balloon away from sharp objects and
excessive amounts of heat.
NOTICE
To prevent balloon deformation, NEVER use lighting system in strong winds.
DO NOT place the balloon inside its protective cover until the lamp has had a suffi cient amount of time to cool down. This will prevent the balloon’s nylon cover from being burned (touching the lamp surface).
ALWAYS place the balloon inside its protective cover after each use. This will prolong the life of the balloon material, keeping it protected from harsh environmental elements.
Replace balloon immediately if damaged. A damaged balloon will not infl ate properly, and may become more damaged by touching the hot lamp surface.
ELECTRICAL SAFETY
DANGER
Lighting system is equipped with a ground pin on the power plug. For your protection, ALWAYS complete the grounding path. NEVER insert the AC power plug into a 2-prong receptacle to operate lighting system.
When applying power to the lighting system, ALWAYS
connect the AC power plug to a 3-prong receptacle that is grounded. The possibility exists of electrical shock, electrocution and even death if the lighting system is not grounded.
NEVER operate lighting system or handle any electrical equipment while standing in water, while barefoot, while hands are wet or in the rain. A dangerous
electrical shock could occur, causing severe bodily harm or even death.
ALWAYS make sure the area above
the lighting system is open and clear of overhead power lines and other obstructions. Contact with overhead power lines or other obstructions could result in equipment damage, electrical
shock, electrocution and even death.
DO NOT use excessive force when zipping and unzipping
the balloon. Be gentle with the zipper mechanism. If the zipper is broken, the balloon will become unusable.
GENERATOR SAFETY
If using a generator to power lighting system, refer to applicable generator manual safety information section.
Power Cord/Cable Safety
DANGER
NEVER let power cords or cables lay in water.
NEVER use damaged or worn cables or cords. Inspect
for cuts in the insulation
NEVER grab or touch a live power cord or cable with wet hands. The possibility exists of electrical shock,
electrocution or death.
Make sure power cables are securely connected. Incorrect connections may cause electrical shock and damage to the lighting system.
NOTICE
ALWAYS make certain that proper power or extension cord has been selected for the job. See Cable Selection Chart in this manual.
PAGE 8 — GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09)
SAFETY INFORMATION
LOADING AND UNLOADING
Cart Type - With Lifi ting Hook
If lighting system is equipped with a transport lifting hook, refer to the following safety information.
CAUTION
Before lifting, make sure that lighting system parts are not damaged and screws are not loosened or lost.
ALWAYS make sure crane or lifting device has been properly secured to lifting hook of the equipment.
NEVER lift the equipment while lighting system is running.
Make sure the mast is completely lowered before lifting the lighting system.
Use adequate lifting cable (wire or rope) of suffi cient strength.
Use one point suspension hook and lift straight upwards.
Cart Type - No Lifi ting Hook
If lighting system is not equipped with a transport lifting hook and the mast is removable, refer to the following safety information.
Before lifting, make sure that the mast and lamp are removed as described in the manual.
The cart can be safely lifted by two persons to the transport vehicle.
TRANSPORTING SAFETY
NOTICE
When transporting the lighting system, if applicable, always place in stow position and place mast in its carrying case.
ALWAYS remove balloon/lamp assembly from the mast when transporting lighting system. This will prevent damage to the bulb due to vibration.
NEVER leave the balloon/lamp exposed during transport. Exposure to excess wind or rain could damage the balloon’s nylon cover.
Never allow any person or animal to stand underneath the equipment while lifting.
DO NOT lift machine to unnecessary heights.
ALWAYS place balloon inside its protective cover during
transport. Be sure the cover is secured tightly around the balloon/lamp assembly.
GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09) — PAGE 9
SPECIFICATIONS
Specifi cationsTable 1.
Model GBW/GBWE/GBS/GBP
Input Voltage 120 VAC
Max. Current 9.3 A @ 120 V
Frequency 50-60 Hz Single-Phase
Appropriate Generator 1700 Watts
Lamp
Lamp Type 1,000 Watt Metal Halide
Total Luminous Flux 107,000 lm
Standard Balloon Diameter 47.2 in (1200 mm)
Light Coverage (360°) 90 ft (27.4 meters)
Lamp Surface Temperature (Longitudinal) 476.6° F (247° C) max
Lamp Surface Temperature (Transversal) 417.2° F (214° C) max
Dimensions (L x W x H) Storage (Lamp)
BALLOON
Balloon Dimensions (L x W x H)
Balloon Material Polyester
Balloon Heat-Resisting Temperature 320-356° F (160-180° C)
Internal Balloon Temperature 126° F (52° C)
Balloon Water Resistance 1,500 mm H
FAN MOTOR
Fan Motor Voltage 100 VAC
Fan Motor Current 0.45/0.55 A
Fan Motor Pressure .347/.372 kPA (.050/.054 psi)
PENTAPOD (GBW/GBWE only)
Outriggers 5
Mast - Number of Stages 3 (air shock absorbers)
GBW Dimensions (L x W x H) Upper Working Position
GBWE Dimensions (L x W x H) Upper Working Position
(1,640 x 1,725 x 2,720 to 4,020 mm)
(1,640 x 1,725 x 2,720 to 4,910 mm)
8.7x 8.7 x 40 in
(700 x 1,023 x 1,212 mm)
47.2 x 47.2 x 28.3 in.
(1200 x 1200 x 720 mm)
O
2
64.6 x 67.9 x 107 to 158.3 in
64.6 x 67.9 x 107 to 193.3 in
Dimensions (L x W x H) Storage (Pentapod)
Weight 56 lb (25.6 kg)
OFFSET POLE (GBS Only)
Mast - Number of Stages 2 stages (offset and straight pole)
Dimensions (L x W x H) Upper Working Position
Dimensions (L x W x H) Storage
Weight 34 lb (15.4 kg)
Offset Pole: 26.9 x 16.7 x 2 in (683 x 425 x 52 mm)
7.9 x 8.7 x 28.3 in
(200 x 220 x 720 mm)
47.2 x 49.6 x 99 in
(1,200 x 1,260 x 2,515 mm)
Straight Pole: 35 in (890 mm)
PAGE 10 — GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09)
DIMENSIONS (GBW/GBWE)
D
B
A
C
E
GBW/GBWE DimensionsFigure 1.
GBW DimensionsTable 2.
Reference Letter Description Dimension inches (mm)
A (GBW) Total Max. Height (with Standard Balloon) 158.3 (4,020)
A (GBWE) Total Max. Height (with Standard Balloon) 193.3 (4,910)
B Standard Balloon Height 28.3 (720)
C Mast Height (without Balloon) 130 (3,302)
D Standard Balloon Diameter 47.2 (1,200)
E Mast Height (Stowed) 28.3 (720)
GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09) — PAGE 11
B
DIMENSIONS (GBS)
GB36 BALLOON
SHOWN
A
GBS DimensionsTable 3.
Reference Letter Dimension inches (mm)
A 44.68 (1,135)
B 35.43 (900)
C 33.46 (850)
D 38.38 (975)
E 85.62 (2,175)
F 26.88 (683)
G 16.73 (425)
H 39.37 (1,000)
I 8.66 (220)
J 7.87 (200)
K 28.34 (720)
C
D
F
OFFSET POLE
E
I
J
STRAIGHT POLE
G
H
K
BALLOON
ASSEMBLY
GBS DimensionsFigure 2.
PAGE 12 — GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09)
DIMENSIONS (GBP)
A
B
GBP DimensionsFigure 3.
GBP DimensionsTable 4.
Reference Letter Dimension inches (mm)
A 35.43 (900)
B 33.46 (850)
GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09) — PAGE 13
.25
FOOTCANDLE PLOT
.5
1
2
5
10
VALUES LISTED AS FOOTCANDLES
Illumination RangeFigure 4.
PAGE 14 — GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09)
SCALE: 1 GRID = 50 FT. (15.24 METERS)
GENERAL INFORMATION
The Multiquip GloBug GBW/GBWE, GBS, GBP are general- purpose, portable, glare-free lighting systems intended for emergency and remote lighting needs. It is universally adaptable to all AC power supplies and accepts 50/60 Hz, 100-240 V.
The GBP (also included with the GBW/GBWE and GBS) provides 360° glarefree illumination. The balloon is self­infl ating and easy to install and infl ate in less than 20 seconds. It uses a single 1,000 watt lamp with pure white light for maximum illumination with a light coverage of up to 150 feet. The balloon is self-infl ating and easy to install and infl ate in less than 20 seconds.
The GBW/GBWE has a three-stage mast that extends to a height of up to 13 feet and 2 inches. The GBW/GBWE has fi ve outriggers (pentapod) for great stabilization.
The GBS is designed to be attached to an external piece of equipment such as a paver. The system is easy to assemble and includes poles and mounting brackets.
The GBHM Hitch Mount can be used to attach a GBP to a hitch on a truck.
The GBMP Plate Mount can be used to attach a GBP to a trailer.
If an extension cord is necessary to connect to a power source, refer to Table 5 to select the proper length.
Extension Cord Gauge SelectionTable 5.
Ampere
Rating
Range
Volts Length of Cord in Feet
115V 25 Ft. 50 Ft. 100 Ft. 150 Ft. 200 Ft. 250 Ft. 300 Ft. 400 Ft. 500 Ft.
230V 50 Ft. 100 Ft. 200 Ft. 300 Ft. 400 Ft. 500 Ft. 600 Ft. 800 Ft. 1000 Ft.
0 - 2 181818161614141212
2 - 3 181816141412121010
3 - 4 18181614121210108
4 - 5 181814121210108 8
5 - 6 1816141210108 8 6
6 - 8 18161210108 6 6 6
8 - 10 18 14 12 10 8 8 6 6 4
10 - 12 16 14 10 8 8 6 6 4 4
12 - 14 16 12 10 8 6 6 6 4 2
14 - 16 16 12 10 8 6 6 4 4 2
16 - 18 14 12 8 8 6 4 4 2 2
18 - 20 14 12 8 6 6 4 4 2 2
GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09) — PAGE 15
GBP
COMPONENTS
20
11
10
13
12
4
19
18
5
9
8
17
16
14
15
1
2
3
7
25
GBWE/GBHM/ GBMP ONLY
6
GBW/GBWE
26
GBHM
GBW/GBWE/GBS/GBP ComponentsFigure 5.
27
GBMP
28
5
24
GBS
21
22
23
PAGE 16 — GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09)
COMPONENTS
Figure 5 shows the location of the controls and components for the GBW Lighting System. The functions of each control is described below:
Balloon Cover 1. — Stores balloon when GBW is not in use. Allow a suffi cient amount of time for the lamp to cool down before storing balloon. Possibility exists of balloon getting burned.
Balloon 2. — Made of heat resistant polyester, with a diameter of 47.2 inches (1,200 mm). Balloon is self­infl ating and infl ates in less than 20 seconds.
Velcro 3. — Used to easily attach optional message strip to the balloon.
Buckle 4. — Used to hold the balloon together when storing inside the cover.
AC Power Cable 5. — Connects to the AC power source (generator) on one end and to the lamp connector on the other end with quick-disconnect connector.
Pentapod6. — Supports and holds up the GBW.
Locking Clamps7. — To secure the generator to the cart
platform, place clamps around the pipe frame of the generator. Tighten securely to prevent movement.
Lamp Holder 14. — Holds lamp in place. Lamp is screwed into socket.
Balloon Connector 15. — Connect this connector to the AC power cable connector.
Lamp/Balloon Bolt 16. — Used to tighten mast when attached to the lamp/balloon assembly.
Fan Motor (Blower) 17. — Infl ates the balloon as soon as power is applied.
Lamp 18. — 1000 watt metal halide bulb with pure white light for maximum illumination.
Lamp Guard 19. — Protects the lamp from being hit by objects and the balloon from touching the lamp.
Carrying Case 20. — Use this case to store the pentapod when transporting or when not in use.
Offset Pole 21. — Supports lamp assembly when attached to the straight pole.
Knob 22. — Secures the offset pole to the straight pole when tightened.
Straight Pole 23. — Used in conjunction with the offset pole to support the lamp assembly.
Stay 8. — Supports the mast against the pentapod.
Mast 9. — This mast is comprised of three separate
stages. The mast can be raised in excess of 8 feet (without balloon). When raising the mast, always be on the lookout for overhead obstructions.
Mast Bolt 10. — Loosen to raise mast and tighten to keep the mast in place when raised to the desired height.
AC Power Cable Connector 11. — Connect this quick- disconnect plug to the balloon connector.
Message Strip (OPTIONAL) 12. — a 12 x 43 inch message strip (GBBALD1) may be attached to the balloon. The message strip can be purchased separately.
Zipper 13. — Zips up balloon to completely close it when lamp is in place.
Clamps 24. — Used to attach the straight pole to an external support. These clamps must be tightened securely to prevent the light assembly from falling off.
Extension Pole 25. — Extends mast height by 40 inches (GBWE). For GBHM and GBMP, 2 poles are included to support the desired balloon assembly.
Hitch Mount Assembly 26. — Used to attach balloon assembly to a hitch on a truck or similar vehicle.
Plate Mount Assembly27. — Used to attach balloon assembly to a trailer or similar vehicle.
Plate28. — Attaches directly to a trailer to hold plate mount assembly.
GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09) — PAGE 17