Complete power panel. Fully covered; three-phase terminals
and single phase receptacles allow fast and convenient
hookup for most applications including temporary power
boxes, tools and lighting equipment. The GFCI receptacles
are NEMA 5-20, and the auxilillary outputs use CS6369 twistlock receptacles.
Simultaneous single and three phase power. Voltage selector switch offers the operator a wide range of
voltages that are manually selectable. Fine tuning of the
output voltage can be accomplished by adjusting the voltage
regulator control knob to obtain the desired voltage.
Heat Rejection to Coolant (per minute)2260 Btu (2.38 MJ)
Heat Rejection to Room (per minute)578 Btu (0.61 MJ)
Maximum Coolant Friction Head6.1 psi (42 kPa)
Maximum Coolant Static Head21 feet (6.4 meters)
Ambient Temperature Rating104°F (40°C)
Air
Combustion Air138 cfm (3.9 m3/min)
Maximum Air Cleaner Restriction25 in. H
Alternator Cooling Air526 cfm (14.9 m
Radiator Cooling Air2009 cfm (56.9 m
O (6.25 kPa)
2
3
/min)
3
/min)
Exhaust System
Gas Flow (full load)332 cfm (9.4 m3/min)
Gas Temperature932°F (500°C)
Maximum Back Pressure53.2 in. H
O (13.3 kPa)
2
Amperage
Rated VoltageMaximum Amps
1Ø 120 Volt
1Ø 240 Volt
155.4 Amps (4 wire)
168A x 2 (Zigzag)
77.8 Amps (4 wire)
168A (Zigzag)
3Ø 240 Volt168 Amps
3Ø 480 Volt84 Amps
Main Line Circuit Breaker Rating175 Amps
Over Current Relay Trip Set Point
480V Mode Only
84 Amps
WARRANTY*
Isuzu Engine
12 months from date of purchase with unlimited hours or 24 months
from date of purchase with 2000 hours (whichever comes first).
Generator
24 months from date of purchase or 2000 hours (whichever occurs first).
Trailer
12 months excluding normal wear items.
*Refer to the express written, one-year limited warranty sheet for additional information.
NOTICE
Generator is not intended for use in enclosed areas or where free
flow of air is restricted.
Backfeed to a utility system can cause electrocution, shock and/
or property damage. DO NOT connect to any building’s electrical
system except through an approved device.
Specifications are subject to change without notice.
DCA70USI — MQ POWER SERIES GENERATOR — REV. #8 (04/17/12)
DCA70USI
MQ POWER Series Generator
GENERATOR OUTPUT PANEL
ULTRA-SILENT FEATURES
Low Noise Muffler — Large capacity low noise muffler
minimizes exhaust sound.
Soundproof Casing — The new design divides the cabinet into
three sections, separating the engine, muffler and radiator for more
efficient cooling and reduces noise from the engine and fans.
New Cooling System — An advanced design uses two
separate air intake systems to cool the generator. The engine
fan draws air in to cool the engine and generator housing while
a second electric fan directly cools the radiator. With less air
being drawn into the generator through each fan, considerably
less noise is produced through the top of the generator.
Environmental Design — Constructed using an integrated
environmental skid and fuel tank. This design fully contains fuel
leakage and any liquid that might leak from the engine such as
lube oil or radiator coolant. All potentially hazardous liquids are
contained without contaminating the surrounding area.
OPTIONAL CONTROL FEATURES
OPTIONAL GENERATOR FEATURES
OPTIONAL OUTPUT CONNECTIONS
Emergency Stop Switch
down generator in the event of an emergency.
— when manually activated shuts
Audible alarm — alerts operator of abnormal conditions.
Electronic Governor Control (Crystal Sync) —
maintains frequency to within ±0.25% from no load to full load.
Battery Charger — provides fully automatic and self-
adjusting charging to the generator's battery system.
Jacket Water Heater — for easy starting in cold weather
climates.
Special Batteries — long life batteries provide extra engine
cranking power.
Spring Isolaters — provides extra vibration protection for
standby applications.
Low Coolant Level Shutdown — provides protection
from critically low coolant levels. Includes control panel
warning light.
Trailer Mounted Package — meets National Highway
Traffic Safety Administration (NHTSA) regulations. Trailer is
equipped with electronic or surge brakes with tandem axle
configuration.
Cam-Lok Connectors — provides quick disconnect
alternative to bolt-on connectors.
Pin and Sleeve Connectors — provides industry standard
connectors for all voltage requirements.
Output Cable — available in any custom length and size
configuration.
DCA70USI — MQ POWER SERIES GENERATOR — REV. #8 (04/17/12)
DCA70USI
MQ POWER Series Generator
DIMENSIONS
Weight
Dry Weight3,771 lbs. (1,710 kg)
Wet Weight4,553 lbs. (2,065 kg)
Max. Lifting
Point Capacity
Generator can be placed on a
MQ Power Model TRLR70XF
Tandem Axle Trailer