Multiquip DCA-220SSVU User Manual

PARTS AND OPERATION MANUAL
OPERATION AND PARTS MANUAL
WHISPERWATT
TM
SERIES
50 Hz GENERATOR
PARTS LIST NO. M4870300024A
Revision #0 (04/18/06)
THIS MANUAL MUST ACCOMPANY
THE EQUIPMENT AT ALL TIMES.
PAGE 2 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
HERE'S HOW TO GET HELP
PLEASE HAVE THE MODEL AND SERIAL
NUMBER
MQ POWER CORPORATE OFFICE
18910 Wilmington Ave. 800-421-1244 Carson, CA 90746 Email: mqpower@multiquip.com Internet: www.mqpower.com
PARTS DEPARTMENT
800-427-1244 310-537-3700
SERVICE DEPARTMENT
800-835-2551 310-537-3700
TECHNICAL ASSISTANCE
800-835-2551
WARRANTY DEPARTMENT
800-835-2551, 310-537-3700,
ON-HAND
EXT.
279
EXT.
279
WHEN CALLING
FAX:
310-632-2656
FAX:
800-672-7877
FAX:
310-637-3284
FAX:
310-638-8046
FAX:
310-638-8046
FAX:
310-638-8046
© COPYRIGHT 2006, MULTIQUIP INC. MQ Power Inc, Ultra-Silent series, and the MQ Power logo are registered trademarks of Multiquip Inc. and may not be used,
reproduced, or altered without written permission. All other trademarks are the property of thier respective owners and used with permission.
This manual should remain with the unit if resold.
The information and specifications included in this publication were in effect at the time of approval for printing. Illustrations are based on the specifications, design or the information published in this publication at any time without notice and without incurring any obligations.
MUST accompany the equipment at all times. This manual is considered a permanent part of the equipment and
DCA-220SSVU (50 Hz) WHISPERWATT AC Generator
. Multiquip Inc. reserves the right to discontinue or change
To find the latest revision of this
publication, visit our website at:
www.mqpower.com
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 3
DCA-220SSVU (50 HZ) TABLE OF CONTENTS
MQ POWER DCA-220SSVU MQ POWER DCA-220SSVU
MQ POWER DCA-220SSVU
MQ POWER DCA-220SSVU MQ POWER DCA-220SSVU
TMTM
TM
TMTM
WHISPERWHISPER
WHISPER
WHISPERWHISPER
California Proposition 65 Warning ..................................... 2
Here's How To Get Help ....................................................3
Table Of Contents ............................................................. 4
Parts Ordering Procedures ............................................... 5
Specifications ................................................................... 6
Dimensions (Top, Side, Front) ........................................... 7
Safety Message Alert Symbols .................................... 8-9
Rules for Safe Operation ........................................... 10-13
Generator Decals....................................................... 14-15
Installation ................................................................. 16-17
General Information ........................................................ 18
Major Components ......................................................... 19
Generator Control Panel ................................................. 21
Engine Operating Panel ............................................. 22-23
Output Terminal Panel Familiarization ........................ 24-26
Load Application ............................................................. 27
Generator Outputs .......................................................... 28
Gauge Reading ............................................................... 29
Output Terminal Panel Connections ........................... 30-31
Pre-Setup .................................................................. 32-35
Generator Start-up Procedure (Manual) ..................... 36-37
Generator Start-up Procedure (Auto Mode) .................... 38
Generator Shut-Down Procedure .................................... 39
Maintenance (Engine) ................................................ 40-41
Jacket Water Heater/battery Charger (Option) ................ 42
Maintenance (Trailer) ................................................. 43-46
Trailer Wiring Diagram .....................................................47
Generator Wiring Diagram ............................................... 48
Engine Wiring Diagram ................................................... 49
Generator Troubleshooting .............................................. 50
Engine Controller Troubleshooting ................................... 51
Explanation of Code in Remarks Column ....................... 52
Suggested Spare Parts .................................................. 53
WW
W
WW
AA
A
AA
TTTT
TT
TTTT
GENERATORGENERATOR
GENERATOR
GENERATORGENERATOR
(50 Hz)(50 Hz)
(50 Hz)
(50 Hz)(50 Hz)
COMPONENT DRACOMPONENT DRA
COMPONENT DRA
COMPONENT DRACOMPONENT DRA
Generator Assembly .................................................. 54-57
Control Panel Assembly ............................................ 58-59
Control Box Assembly ............................................... 60-63
Engine and Radiator Assembly ................................. 64-67
Output Terminal Assembly ......................................... 68-69
Battery Assembly ...................................................... 70-71
Muffler Assembly ......................................................
Fuel Tank Assembly .................................................. 74-75
Enclosure Assembly ................................................. 76-79
Rubber Seals Assembly ............................................ 80-81
Nameplate and Decals .............................................. 82-83
Terms and Condition of Sale — Parts ............................ 84
Specification and part
NOTE
number are subject to change without notice.
WINGSWINGS
WINGS
WINGSWINGS
72-73
PAGE 4 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ) PARTS ORDERING PROCEDURES
When ordering parts,
please supply the following information:
❒❒
Dealer account number
❒❒ ❒❒
Dealer name and address
❒❒ ❒❒
Shipping address (if different than billing address)
❒❒ ❒❒
Return fax number
❒❒ ❒❒
Applicable model number
❒❒ ❒❒
Quantity, part number and description of each part
❒❒ ❒❒
Specify preferred method of shipment:
❒❒
FedEx or UPS Ground FedEx or UPS Second Day or Third Day FedEx or UPS Next Day Federal Express Priority One DHL Tr u c k
Note: Unless otherwise indicated by customer, all orders are treated as “Standard Orders”, and will ship within 24 hours. We will make every effort to ship “Air Shipments” the same day that the order is received, if prior to 2PM west coast time. “Stock Orders” must be so noted on fax or web forms.
Here’s how to get help...
Please have the model and serial number on hand when calling.
MQ POWER CORPORATE OFFICE
18910 Wilmington Ave. 800-421-1244
FAX:
Carson, CA 90746 Email: mqpower@multiquip.com Internet: www.mqpower.com
PARTS DEPARTMENT
800-427-1244 310-537-3700
SERVICE DEPARTMENT
800-835-2551 310-537-3700
TECHNICAL ASSISTANCE
800-835-2551
WARRANTY DEPARTMENT
800-835-2551, 310-537-3700,
EXT. EXT.
279 279
310-632-2656
FAX:
800-672-7877
FAX:
310-637-3284
FAX:
310-638-8046
FAX:
310-638-8046
FAX:
310-638-8046
Place Your Parts Order Via Web or Fax
For Even More Savings!
(Domestic USA Dealers Only)
Extra Discounts!
All parts orders which include complete part numbers and are received by our automated web parts order system, or by fax qualify for the following extra discounts:
Ordered Standard Stock orders
via orders ($750 list and above)
Fax 3% 10%
Web 5% 10%
Special freight allowances when you order 10 or more line items via Web or Fax!**
FedEx Ground Service
No other allowances on freight shipped by any other carrier. **Common nuts, bolts and washers (all items under $1.00
list price) do not count towards the 10+ line items.
at no charge for freight
NOTE: DISCOUNTS ARE SUBJECT TO CHANGE
MQPOWER
A Division of Multiquip Inc.
POST OFFICE BOX 6254 CARSON, CA 90749 310-537-3700 • 800-421-1244 FAX: 310-632-2656 E-MAIL: mqpower@multiquip.com INTERNET: www.mqpower.com
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 5
Direct TOLL-FREE access
to our Parts Department:
Toll-free nationwide — 800-427-1244
Toll-free FAX — 800-6-PARTS-7
(800/672-7877)
1
DCA-220SSVU (50 HZ) — SPECIFICATIONS
ledoMUVSS022-ACD
snoitacificepSrotareneG.1elbaT
epyT
mrA gaZgiZ/lartueNhtiwratS
esahP
deepS
noitcennoCeruta
tuptuOybdnatS
tuptuOemirP
Ø1egatloV
Ø3egatloV
ycneuqerF
rotcaFrewoP
thgieWyrD
thgieWteW
,detalitnevfles,dleifgnivloveR
rotarenegsuonorhcnysepytdetcetorpnepo
3
)WK671(AVK022
)WK061(AVK002
,721,001
zH05
mpr0051
8.0
,7
V452dna002
V044dna004,022,002
).gk384,3(.sbl876
).gk298,3(.sbl085,8
snoitacificepSenignE.2elbaT
ledoM
epyT
srednilyCfo.oN
e
kortSxeroB
tnemecalpsiD
gnitratS
nalooC
yticapaCt
yticapaCliOebuL
epyTleuF
yticapaCknaTleuF
noitpmusnoCleuF
yrettaB
srednilyc6
(.lag001
EG147DATATNEPOVLOV
degrahc-obrut,noitcejnitcerid,delooc-retaw,elcyc4
)mm531xmm701(.ni13.5x.ni12.4
)sretil82.7(.ni.uc444
CDV21cirtcelE
)sretil73(.lag8.9
)sretil92(.lag7.7
leuFleseiD2#
)sretil083
tarh/)L2.83(.lag1.01 daollluf
2xHA522-V21
PAGE 6 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ) — DIMENSIONS (TOP, SIDE AND FRONT)
SNOISNEMID.3ELBAT
ecnerefeR
retteL
A).mm070,1(.ni21.24F ).mm056,3(.ni07.341
B).m
C).mm599(.ni71.93H ).mm003,1(.ni81.15
D.mm530,1(.ni47.04
E.mm599(.ni71.93
Figure 1. Dimensions
).mm(.tfnoisnemiDretteLecnerefeR).mm(.tfnoisnemiD
m530,1(.ni47.04G ).mm057,1(.ni98.86
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 7
DCA-220SSVU (50 HZ) — SAFETY MESSAGE ALERT SYMBOLS
FOR YOUR SAFETY AND THE SAFETY OF OTHERS!
Safety precautions should be followed at all times when operating this equipment. Failure to read and understand the Safety Messages and Operating Instructions could result in injury to yourself and others.
This Owner's Manual has been
NOTE
developed to provide complete instructions for the safe and efficient operation of the MQ Power
Model DCA-220SSVU
HAZARD SYMBOLS
Potential hazards associated with the operation of this equipment will be referenced with " appear throughout this manual, and will be referenced in conjunction with Safety "
WARNING - LETHAL EXHAUST GASES
(50 Hz) Whisperwatt™ Generator.
Before using this generator, ensure that the operating individual has read and understands all instructions in this manual.
SAFETY MESSAGE ALERT SYMBOLS
The three (3) Safety Messages shown below will inform you about potential hazards that could injure you or others. The Safety Messages specifically address the level of exposure to the operator, and are preceded by one of three words:
DANGER, WARNING, or CAUTION.
DANGER
You WILL be KILLED or SERIOUSLY injured if you do not follow directions.
equipment in a confined area or enclosed structure that does not provide ample free flow air.
WARNING - EXPLOSIVE FUEL
DO NOT overfill tank, since spilled fuel could ignite if it
comes into contact with hot engine parts or sparks from the ignition system. Store fuel in approved containers, in well-ventilated areas and away from sparks and flames.
NEVER use fuel as a cleaning agent.
Hazard Symbols
Message Alert Symbols
Gasoline engine exhaust gases contain poisonous carbon monoxide. This gas is colorless and odorless, and can cause
DEATH
if inhaled. NEVER operate this
Gasoline
its vapors can cause an explosion if ignited. DO NOT start the engine near spilled fuel or combustible fluids. DO NOT fill the fuel tank while the engine is running or hot.
is extremely flammable, and
" which
".
WARNING
You COULD be KILLED or SERIOUSLY injured if you do not follow directions.
CAUTION
You CAN be injured if you do not follow directions
PAGE 8 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
WARNING - BURN HAZARDS
Engine components can generate extreme heat. To prevent burns, DO NOT touch these areas while the engine is running or immediately after operations. NEVER operate the engine with heat shields or heat guards removed.
DANGER - ELECTROCUTION HAZARDS
During operation of this generator, there exists the possibility of
electrical shock or burn, severe bodily harm
electrocution,
which can cause
or even
DEATH!
DCA-220SSVU (50 HZ) — SAFETY MESSAGE ALERT SYMBOLS
WARNING - ROTATING PARTS
NEVER operate equipment with covers,
or guards removed. Keep
hair
and clothing away from all moving
parts to prevent injury.
CAUTION - ACCIDENTAL STARTING
ALWAYS place the Engine ON/OFF
switch in the OFF position and remove the ignition key when the pump is not in use.
CAUTION - OVER-SPEED CONDITIONS
NEVER tamper with the factory settings
of the engine governor or settings. Personal injury and damage to the engine or equipment can result if operating in speed ranges above maximum allowable.
fingers, hands
CAUTION - RESPIRATORY HAZARDS
,
CAUTION - SIGHT AND HEARING HAZARDS
CAUTION - EQUIPMENT DAMAGE MESSAGES
Other important messages are provided throughout this manual to help prevent damage to your generator, other property, or the surrounding environment.
ALWAYS wear approved protection.
ALWAYS wear approved
hearing
protection.
respiratory
eye
and
This generator, other property, or
NOTE
the surrounding environment could be damaged if you do not follow instructions.
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 9
DCA-220SSVU (50 HZ) — RULES FOR SAFE OPERATION
DANGER - READ THIS MANUAL!
Failure to follow instructions in this manual may lead to
serious injury
operated by trained and qualified personnel only! This equipment is for industrial use only.
The following safety guidelines should always be used when operating the
or even
DEATH
! This equipment is to be
DCA-220SSVU (50 HZ)Whisperwatt™ AC
Generator.
General Safety:
DO NOT operate or service this equipment before reading this entire manual.
The operator MUST BE familiar with proper safety precautions and operations techniques before using generator.
This equipment should not be operated by persons under 18 years of age.
NEVER operate this equipment without proper protective clothing, shatterproof glasses, steel-toed boots and other
ALWAYS check the machine for loosened threads or bolts before starting.
NEVER operate the generator in an explosive atmosphere or near combustible materials. An explosion or fire could result causing severe
NEVER touch the hot exhaust manifold, muffler or cylinder. Allow these parts to cool before servicing engine or generator.
High Temperatures – Allow the engine to cool before performing service and maintenance functions. Contact with
hot!
components can cause serious
burns.
The engine of this generator requires an adequate free flow of cooling air. enclosed or narrow area where free flow of the air is restricted. If the air flow is restricted it will cause serious damage to the generator or engine and may cause injury to people. The generator engine gives off DEADLY carbon monoxide gas.
bodily harm or even death.
NEVER
operate the generator in any
protective devices required by the job.
NEVER operate this equipment when not feeling well due to fatigue, illness or taking medicine.
NEVER operate this equipment under the influence or drugs or alcohol.
NEVER use accessories or attachments, which are not recommended by MQ Power for this equipment. Damage to the equipment and/or injury to user may result.
Manufacturer does not assume responsibility for any accident due to equipment modifications. Unauthorized equipment modification will void all warranties.
Whenever necessary, replace nameplate, operation and safety decals when they become difficult read.
DO NOT place hands or fingers inside generator engine compartment when engine is running.
NEVER run engine without air filter. Severe engine damage may occur.
DO NOT leave the generator running in the unattended.
Refer to the technical questions or information.
ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children.
VOLVO Engine Owner's Manual
manual mode
for engine
PAGE 10 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ) — RULES FOR SAFE OPERATION
Generator Grounding
DANGER - ELECTROCUTION HAZARDS
To guard against electrical shock and possible damage to the equipment, it is important to provide a good EARTH ground.
During operation of this generator, there exists the possibility of
electrical shock or burn,
Article 250 (Grounding) of the
National Electrical Code
severe bodily harm
(NEC) provides guide lines for proper grounding and specifies that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as practical.
The following safety recommendations should also be followed:
To avoid these hazards: NEVER use damaged or worn cables when connecting
equipment to the generator. Make sure power connecting cables are securely connected to the generator’s output terminals, insufficient tightening of the terminal connections may cause damage to the generator
ALWAYS make sure generator is properly grounded.
NEVER use gas piping as an electrical ground.
ALWAYS make sure that electrical circuits are properly
grounded
local codes before operating generator. Severe
DEATH!
per the
National Electrical Code
(NEC) and
injury
by electrocution can result from operating an
ungrounded generator.
ALWAYS be sure to use the ground terminal (green wire) when connecting a load to the U,V, and W output terminal lugs.
and electrical shock. NEVER grab or touch a live power
cord with wet hands. NEVER touch output terminals
or
during operation. This is extremely dangerous. ALWAYS stop the machine and place the circuit breaker in the OFF position when contact with the output terminals is required.
electrocution,
which can cause
or even
DEATH!
POWER
CORD
(POWER ON)
WET
HANDS
Electrical Safety
ALWAYS have a qualified electrician perform the generator wiring installation.
ALWAYS make sure generator installation is accordance with the
National Electrical Code
(NEC) and local codes
before operating generator.
NEVER use a defective or frayed power cable. Check the cable for cuts in the insulation.
NEVER use a extension cord that is frayed or damaged where the insulation has been cut.
ALWAYS make certain that proper extension cord has been selected for the job. See Table 6.
NEVER power cables or cords
NEVER
stand in water
while AC power from the generator
lay in wate
r.
is being transfer to a load.
Backfeed to a utility system can cause
electrocution
and or property damage. DO NOT connect to any building's electrical system except through an approved device or after building main switch is opened. ALWAYS have a licensed electrician perform the installation
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 11
DCA-220SSVU (50 HZ) — RULES FOR SAFE OPERATION
Maintenance Safety
The electrical voltage required to operate the generator can cause severe injury or even death through physical contact with live circuits. before performing maintenance on the generator.
NEVER lubricate components or attempt service on a running machine.
ALWAYS disconnect the before performing service on the generator.
Follow all Battery Safety Guidelines listed in this manual when handleing or servicing the generator.
ALWAYS allow the machine a proper amount of time to cool before servicing.
Keep the machinery in proper running condition.
Fix damage to the machine immediately and always replace broken parts.
ALWAYS service air cleaner frequently to prevent engine malfunction.
WARNING - BURN HAZARDS
To prevent burns, DO NOT touch or open any of the below mentioned components while the engine is running or immediately after operations. Always allow sufficient time for the engine and generator to cool before performing maintenance.
Radiator Cap - Removing the radiator cap while the engine is hot will result in high pressurized, boiling water to gush out of the radiator, causing severe scalding to any persons in the general area of the generator.
Coolant Drain Plug - Removing the coolant drain plug while the engine is hot will result in hot coolant gushing out of the coolant drain plug, therefore causing severe scalding to any persons in the general area of the generator.
Turn all circuit breakers OFF
NEGATIVE battery terminal
Battery Safety
Use the following guidelines when handling the battery:
The battery contains acids that can cause injury to the eyes and skin. To avoid eye irritation, glasses.
Use well insulated gloves when picking up the battery.
DANGER - EXPLOSION HAZARDS
The risk of an explosion exists when performing service on the battery. To avoid
DO NOT drop the battery. There
is the possibility of risk that the battery may explode.
DO NOT expose the battery to
open flames, sparks, cigarettes etc. The battery contains combustible gases and liquids. If these gases and liquids come in contact with a flame or spark, an explosion could occur.
ALWAYS keep the battery charged. If the battery is not charged a buildup of combustible gas will occur.
ALWAYS keep battery charging and cables in good working condition. Repair or replace all worn cables.
ALWAYS recharge the battery in an vented air environment, to avoid risk of a dangerous concentration of combustible gases.
In case the battery liquid (dilute sulfuric acid) comes in contact with immediately with plenty of water.
In case the battery liquid (dilute sulfuric acid) comes in contact with your plenty of water and contact the nearest doctor or hospital to seek medical attention.
always
clothing or skin
EYES
wear safety
severe injury
, rinse eyes immediately with
or
DEATH:
, rinse skin or clothing
Engine Oil Drain Plug - Removing the engine oil drain plug while the engine is hot will result in hot oil gushing out of the oil drain plug, therefore causing severe scalding to any persons in the general area of the generator.
PAGE 12 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ) — RULES FOR SAFE OPERATION
Towing & Transporting Safety
To reduce the possibility of an accident while transporting the generator on public roads, always make sure the trailer that supports the generator and the towing vehicle are in good operating condition and both units are mechanically sound.
The following list of safety precautions should be followed when towing your generator:
CAUTION - FOLLOW TOWING REGULATIONS
Check with your local county or state safety towing regulations, in addition to meeting
Transportation
towing your generator.
ALWAYS shutdown engine before transporting.
Tighten both fuel tank caps securely.
If generator is mounted on a trailer, make sure trailer complies with all local and state safety transportation laws. Follow the listed guidelines for basic towing techniques.
Make sure the hitch and coupling of the towing vehicle are rated equal to, or greater than the trailer "gross vehicle weight rating.”
ALWAYS inspect the hitch and coupling for wear. NEVER tow a trailer with defective hitches, couplings, chains etc.
(DOT)
Safety Towing Regulations
Towing & Transporting Safety
Department of
, before
The maximum speed for highway towing is 55 MPH unless posted otherwise. Recommended off-road towing is not to exceed 15 MPH or less depending on type of terrain.
Place while parked.
Use the trailer’s swivel jack to adjust the trailer height to a level position while parked.
Avoid sudden stops and starts. This can cause skidding, or jack-knifing. Smooth, gradual starts and stops will improve towing.
Avoid sharp turns.
Trailer should be adjusted to a level position at all times when towing.
Raise and lock trailer wheel stand in up position when transporting.
The maximum speed for highway towing is 55 MPH unless posted otherwise. Recommended off-road towing is not to exceed 15 MPH or less depending on type of terrain.
Place prevent tipping, while parked.
Avoid sharp turns to prevent rolling.
DO NOT transport generator with fuel in tank.
Emergencies
chock blocks
support blocks
underneath wheel to prevent rolling,
underneath the trailer’s bumper to
Check the tire air pressure on both towing vehicle and trailer. Also check the tire tread wear on both vehicles.
ALWAYS make sure the trailer is equipped with a "Safety Chain".
ALWAYS attach trailer’s safety chains to towing vehicle properly.
ALWAYS make sure the vehicle and trailer directional, backup, brake, and trailer lights are connected and working properly.
DOT Requirements include the following:
z z
Trailer tires should be inflated to 50 psi cold.
Connect and test electric brake operation. Secure portable power cables in cable tray with tie wraps.
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 13
ALWAYS know the location of the nearest
ALWAYS know the location of the nearest and
ALWAYS know the location of the nearest phone or
the job site,
ALWAYS have easy access to the phone
numbers of the nearest and be invaluable in the case of an emergency.
fire extinguisher
first aid kit
keep a phone on
in case of emergencies.
Fire Department
.
.
Ambulance, Doctor
. This information will
1
DCA-220SSVU (50 HZ) — GENERATOR DECALS
The DCA-220SSVU (50 HZ)generator is equipped with a number of safety decals (Figures 2 & 3). These decals are provided for operator safety and maintenance information. The illustration below and on the preceding page show the decals as they appear on the machine. Should any of these decals become unreadable, replacements can be obtained from your dealer.
Figure 2. Generator Decals
PAGE 14 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ) — GENERATOR DECALS
Figure 3. Generator Decals (Cont inued)
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 15
1
DCA-220SSVU (50 HZ) — INSTALLATION
Figure 4. Typical Generator Grounding Application
PAGE 16 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ) — INSTALLATION
Outdoor Installation
Install the generator in a area that is free of debris, bystanders, and overhead obstructions. Make sure the generator is on secure level ground so that it cannot slide or shift around. Also install the generator in a manner so that the exhaust will not be discharged in the direction of nearby homes.
The installation site must be relatively free from moisture and dust. All electrical equipment should be protected from excessive moisture. Failure to do will result in deterioration of the insulation and will result in short circuits and grounding.
Foreign materials such as dust, sand, lint and abrasive materials have a tendency to cause excessive wear to engine and alternator parts.
CAUTION - EXHAUST HAZARD
Pay close attention to ventilation when operating the generator inside tunnels and caves. The engine exhaust contains noxious elements. Engine exhaust must be routed to a ventilated area.
Indoor Installation
Generator Grounding
To guard against electrical shock and possible damage to the equipment, it is important to provide a good EARTH ground.
Article 250 (Grounding) of the National Electrical Code (NEC) provides guide lines for proper grounding and specifies that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as practical.
NEC articles 250-64(b) and 250-66 set the following grounding requirements:
1. Use one of the following wire types to connect the generator to earth ground.
a. Copper - 10 AWG (5.3 mm2) or larger. b. Aluminum - 8 AWG (8.4 mm2) or larger.
2. When grounding the generator (Figure 4) connect the ground cable between the lock washer and the nut on the generator and tighten the nut fully. Connect the other end of the ground cable to earth ground.
3. NEC article 250-52(c) specifies that the earth ground rod should be buried aminimum of 8 ft. into the ground.
Exhaust gases from diesel engines are extremely poisonous. Whenever an engine is installed indoors the exhaust fumes must be vented to the outside. The engine should be installed at least two feet from any outside wall. Using an exhaust pipe which is too long or too small can cause excessive back pressure which will cause the engine to heat excessively and possibly burn the valves.
Mounting
The generator must be mounted on a solid foundation (such as concrete) and set firmly on the foundation to isolate vibration of the generator when it is running. The generator must set at least 6 inches above the floor or grade level (in accordance to NFPA 110, Chapter 5-4.1). DO NOT remove the metal skids on the bottom of the generator. They are to resist damage to the bottom of the generator and to maintain alignment.
NOTE
When connecting the generator to any buildings electrical system ALWAYS consult with a licensed electrician.
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 17
DCA-220SSVU (50 HZ) — GENERAL INFORMATION
DCA-220SSVU (50 Hz) Whisperwatt™ Series Familiarization Generator
The MQ Power Model DCA-220SSVU (50 Hz) is a 176 kW
generator
(Figure 5) that is designed as a high quality portable (requires a trailer for transport) power source for telecom sites, lighting facilities, power tools, submersible pumps and other industrial and construction machinery.
Engine Operating Panel
Open Delta Excitation System
The DCA-220SSVU (50 Hz) generator is equipped with the state of the art " delta system consist of an electrically independent winding wound among stationary windings of the AC output section.
There are four connections of the open delta A, B, C and D. During steady state loads, the power from the voltage regulator is supplied from the parallel connections of A to B, A to D, and C to D. These three phases of the voltage input to the
The “Engine Operating Panel” is provided with the following:
■■
Tachometer
■■
■■
Water Temperature Gauge
■■
■■
Oil Pressure Gauge
■■
■■
Charging Ammeter Gauge
■■
■■
Fuel Level Gauge
■■
■■
Pre-Heat Button
■■
■■
Engine Speed Switch
■■
■■
Panel Light/Panel Light Switch
■■
■■
Auto ON/OFF Engine Controller (MPEC)
■■
■■
Coolant Level Alarm Lamp
■■
Generator Control Panel
The “Generator Control Panel” is provided with the following:
■■
Frequency Meter (Hz)
■■
■■
AC Ammeter (Amps)
■■
■■
AC Voltmeter (Volts)
■■
■■
Ammeter Change-Over Switch
■■
■■
Voltmeter Change-Over Switch
■■
■■
Voltage Regulator
■■
■■
3-Pole, 600 amp Main Circuit Breaker
■■
■■
“Control Box” (located behind the Gen. Control Panel)
■■
■■
Automatic Voltage Regulator
■■
■■
Current Transformer
■■
■■
Over-Current Relay
■■
■■
Voltage Rectifer
■■
■■
Starter Relay
■■
■■
Engine Controller (Computer Controlled)
■■
■■
Voltage Selector Switch
■■
voltage regulator are then rectified and are the excitation current for the exciter section.
When a heavy load, such as a motor starting or a short circuit occurs, the automatic voltage regulator (AVR) switches the configuration of the open delta to the series connection of B to C. This has the effect of adding the voltages of each phase to provide higher excitation to the exciter section and thus better voltage response during the application of heavy loads.
The connections of the AVR to the AC output windings are for sensing only. No power is required from these windings.
The open-delta design provides virtually unlimited excitation current, offering maximum motor starting capabilities. The excitation does not have a " according the demands of the required load.
Engine
The DCA-220SSVU (50 Hz) is powered by a 6 cylinder, water cooled, direct injection, turbocharged
PENTA TAD520GE Diesel Engine
to meet every performance requirement for the generator. Reference Table 1 for engine specifications.
In keeping with MQ Power's policy of constantly improving its products, the specifications quoted herein are subject to change without prior notice.
Electric Governor System
The electric governor system controls the RPMs of the en­gine. When the engine demand increases or decreases, the governor system regulates the frequency variation to ±.25%.
Extension Cables
Output Terminal Panel
When electric power is to be provided to various tools or
The “Output Terminal Panel” is provided with the following:
■■
Three 100/200V output receptacles (CS-6369), 50A
■■
■■
Three auxilliary circuit breakers, 50A
■■
■■
Two 100V output receptacles (GFCI), 20A
■■
■■
Two GFCI circuit breakers, 20A
■■
■■
Five output terminal lugs (3Ø power)
■■
■■
Battery Charger (Optional)
■■
■■
Water Heater (Optional)
■■
loads at some distance from the generator, extension cords are normally used. Cables should be sized to allow for distance in length and amperage so that the voltage drop between the generator and point of use (load) is held to a minimum. Use the cable selection chart (Table 6) as a guide for selecting proper extension cable size.
Open-Delta
" excitation system. The open
fixed ceiling
" and responds
VOLVO Model
. This engine is designed
PAGE 18 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ) — MAJOR COMPONENTS
4elbaT. stnenopmoCrojaMrotareneG
.ONMETINOITPIRCSED
1ylbmessAlenaPlanimreTtuptuO
2ylbmessAselcatpeceRtuptuO
3ylbmessAretliFriA
4ylbmessArelffuM
5ylbmessAknaTleuF
6ylbmessAenignE
7ylbmessAyrettaB
8ylbmessArotareneG
9ylbmessArekaerBtiucriC
01ylbmessAlenaPlor
tnoCenignE/rotareneG
Figure 5. Major Components
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 19
NOTE PAGE
PAGE 20 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ) — GENERATOR CONTROL PANEL
Figure 6. Generator Control Panel
The definitions below describe the controls and functions of the DCA-220SSVU
(50 HZ)Generator Control Panel
(Figure
6).
1. Frequency Meter – Indicates the output frequency in hertz (Hz). Normally 60 Hz.
2. AC Ammeter – Indicates the amount of current the load is drawing from the generator per leg selected by the ammeter phase-selector switch.
3. Ammeter Change-Over Switch – This switch allows the AC ammeter to indicate the current flowing to the load connected to any phase of the output terminals, or
Located behind the generator control panel is the
Control Box
electronic components required to make the generator function.
The Control Box is equipped with the following major components:
■■
Over-Current Relay
■■
■■
Voltage Rectifer (AVR)
■■
■■
Starter Relay
■■
■■
Current Transformer
■■
■■
Voltage Selector Switch
■■
■■
Three Phase Circuit Breaker
■■
to be switched off. This switch does not effect the generator output in any fashion, it is for current reading only.
NOTE
4. Voltage Regulator Control – Allows ±15% manual
adjustment of the generator’s output voltage.
5. AC Voltmeter – Indicates the output voltage present at the
U,V, and W Output Terminal Lugs
.
In the event of a short circuit or over current condition, it will automatically trip the 600 amp main breaker.
6. Voltmeter Change-Over Switch – This switch allows the AC voltmeter to indicate phase to phase voltage between any two phases of the output terminals or to be switched off.
To restore power to the
reset
button on the overcurrent relay and place the
circuit breaker in the
Generator
. This box contains some of the necessary
Remember the
relay
monitors the current
flowing from the
Output Terminal Lugs
overcurrent
U,V, and W
to the
load.
Output Terminal Panel
, press the
main
closed
position (ON).
7. Main Circuit Breaker – This three-pole, 600A main
breaker is provided to protect the the
Terminal Lugs
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 21
from overload.
U,V, and W Output
1
DCA-220SSVU (50 HZ)— ENGINE OPERATING PANEL
Figure 7. Engine Operating Panel
PAGE 22 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ)— ENGINE OPERATING PANEL
The definitions below describe the controls and functions of the DCA-220SSVU
7).
1. Panel Light – Normally used in dark areas or at night time. When activated, panel lights will illuminate. When the generator is not in use be sure to turn the panel light switch to the OFF position.
2. Panel Light Switch – When activated will turn on control panel light.
3. Oil Pressure Gauge – During normal operation this gauge be should read between 44 to 73 psi. (303~503 kPa). When starting the generator the oil pressure may read a little higher, but after the engine warms up the oil pressure should return to the correct pressure range.
4. Water Temperature Gauge – During normal operation this gauge be should read between 165° and 203°F.
5. Charging Ammeter Gauge – Indicates the current being supplied by the engine’s alternator which provides current for generator’s control circuits and battery charging system.
6. Fuel Gauge - Indicates amount of diesel fuel available.
7. Tachometer – Indicates engine speed in RPM’s for 60
Hz operation. This meter should indicate 1800 RPM’s when the rated load is applied. In addition a built in hour meter will record the number of operational hours that the generator has been in use.
8. Engine Speed Switch – This switch controls the speed of the engine (low/high).
9. Pre-Heat Button – Press and hold this button for 50 seconds to warm (cold weather) the engine glow plugs.
10. Coolant Alarm Lamp – This lamp will illuminate when the coolant level falls below a safe operating level.
11. Auto On/Off Engine Controller (MPEC) – This controller has a vertical row of status LED's (inset), that when lit, indicate that an engine malfunction (fault) has been detected. When a fault has been detected the engine controller will evaluate the fault and all major faults will shutdown the generator. During
cycle
, The MPEC will attempt to crank the engine for 10 seconds before disengaging.
(50 Hz) Engine Operating Panel
(Figure
cranking
If the engine does not engage (start) by the third attempt, the engine will be shutdown by the engine controller’s
Crank Protection
(RPM's) that is not safe, the controller will shutdown the engine by initializing the
Also the engine controller will shut down the engine in the event of low oil pressure, high coolant temperature, low coolant level, and loss of magnetic pickup. These conditions can be observed by monitoring the LED status indicators on the front of the controller module.
A. MPEC Control Switch – This switch controls the
running of the unit. If this switch is set to the OFF/RESET position, the unit will not run. When this switch is set to the MANUAL position, the generator will start immediately.
If the generator is to be connected to a building's AC power source via a transfer switch (isolation), place the switch in the AUTO position. In this position the generator will monitor the AC line output from the building's power source.
B. Low Oil Pressure – Indicates the engine pressure has
fallen below 15 psi. The oil pressure is detected using variable resistive values from the oil pressure sending unit. This is considered a
C. High Coolant Temperature – Indicates the engine
temperature has exceeded 239°F. The engine temperature is detected using variable resistive values from the temperature sending unit. This is considered a
major
D. Overcrank Shutdown – Indicates the unit has
attempted to start a pre- programmed number of times, and has failed to start. The number of cycles and duration are programmable. It is pre-set at 3 cycles with a 10 second duration. This is considered a fault.
E. Overspeed Shutdown – Indicates the engine is running
at an unsafe speed. This is considered a
F. Engine Running – Indicates that engine is running at
a safe operating speed.
Over
mode. If the engine engages at a speed
fault.
Over Speed Protection
major
fault.
mode.
major
major
fault.
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 23
DCA-220SSVU (50 HZ)— OUTPUT TERMINAL PANEL FAMILIARIZATION
Output Terminal Panel
The
Output Terminal Panel
(Figure 8) shown below is located on the right-hand side (left from control panel) of the generator. Lift up on the cover to gain access to receptacles and terminal
Output Terminal Familiarization
The “
Output Terminal Panel
following:
■■
Three (3) 100/200V output receptacles @ 50 amp
■■
lugs.
■■
Three (3) Circuit Breakers @ 50 amps
■■
■■
Two (2) 100V GFCI receptacles @ 20 amp
■■
■■
Two (2) GFCI Circuit Breakers @ 20 amps
■■
.
■■
Five (5) Output Terminal Lugs ( U, V, W, O, Ground)
■■
NOTE
Terminal legs “O” and “Ground”
are considered
bonded grounds
” (Figure 8) is provided with the
Figure 8. Output Terminal Panel
PAGE 24 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ)— OUTPUT TERMINAL PANEL FAMILIARIZATION
100 VAC GFCI Receptacles
There are two 100 VAC, 20 amp GFCI (Duplex Nema 5-20R) recepacles provided on the output terminal panel. These receptacles can be accessed in any position. Each receptacle is protected by a 20 amp circuit breaker. These breakers are located directly above the GFCI receptacles. Remember the load output (current) of both GFCI receptacles is dependent on the load requirements of the U, V, and W output terminal lugs.
Pressing the being tripped. Pressing the the center of the receptacle will check the GFCI function. Both receptacles should be tested at least once a month.
reset
button resets the GFCI receptacle after
voltage selector switch
Test Button
(See Figure 9) in
Each auxilliary receptacle is protected by a 50 amp circuit breaker. These breakers are located directly above the GFCI receptacles. Remember the load output (current) on all three receptacles is dependent on the load requirements of the
Output Terminal Lugs
Turn the control panel to obtain the desired voltage. Turning the knob clockwise will clockwise will
Removing the Plastic Face Plate (Hard Wire Hookup Panel)
The
Output Terminal Lugs
plate cover (Figure 12). Un-screw the securing bolts and lift the plastic terminal cover to gain access to the terminal enclosure.
.
voltage regulator control knob
increase
decrease
Figure 11. Voltage Regulator Control Knob
the voltage, turning the knob counter-
the voltage.
are protected by a plastic face
(Figure 11) on the
After the load wires have been securely attached to the terminal lugs, reinstall the plastic face plate.
Figure 9. G.F.C.I. Receptacle
Twist Lock Dual Voltage 100/200 VAC Receptacles
There are three 100/200V, 50 amp auxilliary twist-lock (CS-6369) recepacles (Figure 10) provided on the output terminal panel.These receptacles can when the voltage selector switch is placed in the
phase 240/120 position.
only
be accessed
single-
Figure 12. Plastic Face Plate (Output Terminal Lugs)
Figure 10. 100/200V Twist-Lock
Auxiliary Receptacles
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 25
1
DCA-220SSVU (50 HZ)— OUTPUT TERMINAL PANEL FAMILIARIZATION
Connecting Loads
Loads can be connected to the generator by the
Terminal Lugs
Make sure to read the operation manual before attempting to connect a load to the generator.
To protect the output terminals from overload, a 3-pole, 600A switch ALL circuit breakers to the OFF position prior to starting the engine.
or the convienience receptacles (Figure 13).
main
circuit breaker is provided. Make sure to
Ouput
Over Current Relay
over current relay
An circuit breaker. In the event of an overload, both the circuit breaker and the over current relay may trip. If the circuit breaker can not be reset, the rent relay must be pressed. The over current relay is lo­cated in the control box.
(Figure 14) is connected to the main
reset button
Figure 14. Over Current Relay
on the over cur-
Figure 13. Connecting Loads
PAGE 26 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ)— LOAD APPLICATION
Single Phase Load
Always be sure to check the nameplate on the generator and equipment to insure the wattage, amperage,
frequency
Three Phase Load
When calculating the power requirements for 3-phase power use the following equation:
, and voltage requirements are satisfactorily supplied by the generator for operating the equipment.
Generally, the wattage listed on the nameplate of the equipment is its rated output. Equipment may require 130— 150% more wattage than the rating on the nameplate, as the wattage is influenced by the efficiency, power factor and
NOTE
starting system of the equipment.
If wattage is not given on the equipment's name plate,
NOTE
approximate wattage may be determined by multiplying nameplate voltage by the nameplate amperage.
NOTE
WATTS = VOLTAGE x AMPERAGE
The power factor of this generator is 0.8. See Table 5 below when connecting loads.
An inadequate size connecting cable which cannot carry the required load can cause a voltage drop which can burn out
daoLyBrotcaFrewoP.5elbaT
daoLfOepyTrotcaFrewoP
srotomnoitcudniesahp-elgniS57.0-4.0
tnecsednacni,sretaehcirtcelE
spmal
m,spmaltnecseroulF9.0-4.0
tnempiuqe
slootrewopnommoC8.0
spmalyrucre
noitacinummoc,secivedcinortcelE
0.1
0.1
the appliance or tool and overheat the cable. See Table 6.
■■
When connecting a resistance load such as an
■■
incandescent lamp or electric heater, a capacity of up to the generating set’s rated output (kW) can be used.
■■
When connecting a fluorescent or mercury lamp, a
■■
capacity of up to the generating set’s rated output (kW) multiplied by 0.6 can be used.
■■
When connecting an electric drill or other power tools,
■■
pay close attention to the required starting current capacity.
If 3Ø load (kVA) is not given on the equipment nameplate, approximate 3Ø load output maybe determined by multiplying voltage by amperage by 1.732.
Motors and motor-driven equipment draw much greater current for starting than during operation.
)noitarepOesahPelgniS,zH06(noitceleSelbaC.6elbaT
nitnerruC
serepmA
5.20
50060021.tf005.tf003.tf002.tf521
5.70090081.tf053.tf002.tf521.tf001
0100210042.tf052.tf051.tf00
5100810063.tf051.tf001.tf56
0200420084.tf521.tf57.tf05
sttaWnIdaoLhtgneLelbaCelbawollAmumixaM
001tA
stloV
03006.tf0001.tf006.tf573.tf052
002tA
stloV
eriW01#eriW21#eriW41#eriW61#
1
.egatlovwolmorftlusernacegamadtnempiuqE:NOITUAC
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 27
When connecting ordinary power tools, a capacity of up to the generating set’s rated output (kW) multiplied by 0.8 can be used.
DANGER - ELECTRICAL SYSTEM HAZARDS
Before connecting this generator to any building’s electrical system, a
(transfer) switch
licensed electrician
must install an
. Serious damage to the building’s
isolation
electrical system may occur without this transfer switch.
1
DCA-220SSVU (50 HZ) — GENERATOR OUTPUTS
Generator Output Voltages
A wide range of voltages are available to supply voltage for many different applications. Voltages are selected by apply­ing jumpers (6) to the To obtain some of the voltages as listed in Table 6 (see below) will require a fine adjustment using the
lator
(VR)
control knob
Voltage Change-Over Board
The
voltage change-over board
the control box, behind the generator control panel. This board has been provided for ease of voltage selection.
voltage change-over board
(Figure 15).
voltage regu-
located on the control panel.
(Figure 15) is located on
Generator Amperage
Tables 8 describes the generator’s current output capability for 3Ø phase applications.
WKV002V004
022763
0444127
06612801
08882441
001063081
021334612
041505252
061675882
sgnitaRerepmArotareneG.8elbaT
⎯⎯⎯⎯3∅∅∅∅
Maximum Amps
Table 9 shows the
Figure 15. Voltage Change-Over Board
CAUTION - CHANGING VOLTAGES
NEVER attempt to place jumper plates on the
change-over board
There exist the possibility of
while the generator is in operation.
electrocution, electrical
voltage
vide. DO NOT exceed the maximum amps as listed.
shock or burn, which can cause severe bodily harm or even death
!
elbaliavAsegatloV.7elbaT
esahPeerhT
esahPelgniS
V002V022V042V614V044
V511V721V931V042V452
maximum
ledoMUVSS022ACD
egatloVdetaRspmAmumixaM
esahPelgniS
tloV001
lgniS
esahPe
tloV002
esahPeerhT
tloV002
esahPeerhT
tloV004
amps the generator can pro-
spmAmumixaMrotareneG.9elbaT
)eriw4(spma335
)eriw4(spma662
spma775
spma882
PAGE 28 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ)— GENERATOR OUTPUTS/ GAUGE READING
How to Read the Output Terminal Gauge.
The AC ammeter and AC voltmeter change-over switches on the control panel DO NOT effect the generator output. They are provided to help observe how much power is being supplied, produced at the UVWO terminals lugs.
When the voltage change-over board is jumpered for 240V operation (See Figures 17 and18), place the
meter Change-Over Switch
W-U position and the (Figure 19) to the U or W position to read the output on the selected leg.
Figure 16. Voltage Change-Over Board
240V Configuration
(See Figures 19 and 20) to the
AC Ammeter Change-Over Switch
3Ø,
AC Volt-
Figure 17. AC Voltmeter
Change-Over Switch
Figure 19. AC Ammeter
Change-Over Switch
Figure 18. AC Voltmeter Gauge
(Volt reading on W-U Lug)
Figure 20. AC Ammeter
(Amp reading on U lug)
The
NOTE
ammeter
show a reading when the
Output Terminal Lugs
connected to a load and in use.
gauge will only
are
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 29
DCA-220SSVU (50 HZ) — OUTPUT TERMINAL PANEL CONNECTIONS
UVWO Terminal Output Voltages
Various output voltages can be obtained using the UVWO output terminal lugs. The voltages at the terminals are de­pendent on the placement of the jumpers plates (6) on the
Voltage Change-Over Board Voltage Regulator Control Knob
and the adjustment of the
.
Figure 23. Voltage Regulator Knob
Remember the voltage change-over board determines the
range
of the output voltage and can be configured in two different positions that provide 6 different output voltages at the UVWO output terminals. The generator is shipped from the factory in the 200V configuration. The voltage regulator (VR) allows the user to increase or decrease the selected
1Ø-200V UVWO Terminal Output Voltages
1. Make sure the voltage change-over board is jumpered for 240V operation as shown in Figure 21 .
2. Connect the load wires to the UVWO terminals as shown in Figure 24.
voltage.
3Ø-220V UVWO Terminal Output Voltages
1. Jumper the voltage change-over board for 240V operation as shown in Figure 21.
Figure 21. Voltage Change-Over Board
2. Connect the load wires to the UVWO terminals as shown in Figure 22.
240V Configuration
1Ø-127V UVWO Terminal Output Voltages
1. Make sure the voltage change-over board is jumpered for 240V operation as shown in Figure 21.
2. Connect the load wires to the UVWO terminals as shown in Figure 25.
Figure 24. UVWO Terminal Lugs
1Ø-200V Connections
Figure 22. UVWO Terminal Lugs
3Ø-220V Connections
3. Turn the voltage regulator knob (Figure 23) clockwise to increase voltage output, turn counterclockwise to decrease voltage output. Use voltage regulator adjustment knob whenever fine tuning of the output voltage is required
PAGE 30 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
Figure 25. UVWO Terminal Lugs
1Ø-127V Connections
DCA-220SSVU (50 HZ) — OUTPUT TERMINAL PANEL CONNECTIONS
3Ø-440V UVWO Terminal Output Voltages
1. Jumper the voltage change-over board for 480V operation
as shown in Figure 26. This configuration uses 6 jumper plates in 3 different positions. Remember there are 2 jumper plates at every position. Every jumper plate
must
1Ø-440V UVWO Terminal Output Voltages
1. Make sure the voltage change-over board is jumpered for 480V operation as shown in Figure 26.
2. Connect the load wires to the UVWO terminals as shown in Figure 28.
be used.
Figure 26. Voltage Change-Over Board
480V Configuration
2. Connect the load wires to the UVWO terminals as shown in Figure 27.
1Ø-254V UVWO Terminal Output Voltages
1. Make sure the voltage change-over board is jumpered for 480V operation as shown in Figure 26.
Figure 28. UVWO Terminal Lugs
1Ø-440V Connections
NOTE
Figure 27. UVWO Terminal Lugs
3Ø-440V Connections
ALWAYS make sure that the
connections to the UVWO terminals are The possibility of arcing exists, that could cause a fire.
secure
2. Connect the load wires to the UVWO terminals as shown in Figure 29.
Figure 29. UVWO Terminal Lugs
1Ø-254V Connections
and tight.
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 31
DCA-220SSVU (50 HZ)— PRE-SETUP
Circuit Breakers
Fuel Check
To protect the generator from an overload, a 3-pole, 600 amp,
main
circuit breaker is provided to protect the
Output Terminals
20 amp
GFCI
from overload. In addition two single-pole,
circuit breakers are provided to protect the
GFCI receptacles from overload. Three 50 amp
U,V, and W
load
circuit
breakers have also been provided to protect the auxiliary
DANGER - EXPLOSION/FIRE HAZARDS
Fuel spillage on a If fuel spillage occurs, wipe up the spilled fuel completely to prevent fire hazards. NEVER smoke around or near the generator.
receptacles from overload. Make sure to switch ALL circuit breakers to the OFF position prior to starting the engine.
Lubrication Oil
Fill the engine crankcase with lubricating oil through the filler hole, but DO NOT overfill. Make sure the generator is level. and verify that the oil level is maintained between the two notches (Figure 30) on the dipstick. See Table 10 for proper selection of engine oil.
Refilling the Fuel System
CAUTION - REFUELING THE GENERATOR
ONLY properly trained personel who have read and
understand this section should refill the fuel tank system.
Figure 30. Engine Oil Dipstick
This generator has an internal fuel tank located inside the
When checking the engine oil, be sure to check if the oil is clean. If the oil is not clean, drain the oil by removing the oil drain plug, and refill with the specified amount of oil as outlined in the Volvo Engine Owner's Manual. Oil should be warm before draining.
Other types of motor oils may be substituted if they meet the following requirements:
■■
API Service Classification CC/SC
■■
■■
API Service Classification CC/SD
■■
■■
API Service Classification CC/SE
■■
■■
API Service Classification CC/SF
■■
trailer frame and may also be equipped with an environmental fuel tank (Figure 31). fresh
#2 diesel fuel.
capacities. Pay attention to the fuel tank capacity when replenishing
fuel.The fuel tank cap must be closed tightly after filling. Handle fuel in a safety container. If the container does not have a spout, use a funnel. Wipe up any spilled fuel immediately.
hot
engine can cause a
ALWAYS
fill the fuel tanks with clean
fire
or
explosion
DO NOT fill the fuel tanks beyond their
.
Figure 31. Internal Fuel Tank System
PAGE 32 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ)— PRE-SETUP
Refueling Procedure:
WARNING - RESPIRATORY HAZARDS
Diesel fuel and its vapors are dangerous
to your health and the surrounding environment. Avoid skin contact and/or inhaling fumes.
1. Level Tanks – Make sure fuel cells are level with the ground. Failure to do so will cause fuel to spill from the tank before reaching full capacity (Figure 32).
CAUTION - REFUELING THE GENERATOR
ALWAYS
to prevent spilling and maximize the amount of fuel that can be pumped into the tank.
place trailer on firm level ground before refueling
3. Open cabinet doors on the “right side” of the generator (from generator control panel position). Remove fuel cap and fill tank (Figure 33).
Figure 33. Fueling the Generator
Figure 32. Only Fill on Level Ground
NOTE
ONLY! use
refueling.
#2 diesel fuel
3. NEVER overfill fuel tank – It is important to read the fuel gauge when filling trailer fuel tank. DO NOT wait for fuel to rise in filler neck (Figure 34).
when
Figure 34. Full Fuel Tank
CAUTION - REFUELING THE GENERATOR
DO NOT OVER-FILL fuel system. Leave room for fuel
expansion. Fuel expands when heated (Figure 35).
Figure 35. Fuel Expansion
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 33
1
DCA-220SSVU (50 HZ)— PRE-SETUP
Coolant (ISUZU Antifreeze/Summer Coolant/Water)
VOLVO recommends VOLVO antifreeze/summer coolant for use in their engines, which can be purchased in concentrate (and mixed with 50% demineralized water) or pre-diluted. See the VOLVO Engine Owner's Manual for further details.
Cleaning the Radiator
The engine may overheat if the radiator fins become overloaded with dust or debris. Periodically clean the radiator fins with compressed air. Cleaning inside the machine is dangerous, so clean only with the engine turned off and the
negative
WARNING - BURN HAZARDS
Air Cleaner
Periodic cleaning/replacement is necessary. Inspect it in
If adding coolant/antifreeze mix to the
accordance with the VOLVO Engine Owner's Manual.
radiator, DO NOT remove the radiator cap until the unit has completely cooled. The possibility of
hot!
coolant exists which
can cause severe burns.
Fan Belt Tension
A slack fan belt may contribute to overheating, or to insufficient charging of the battery. Inspect the fan belt for damage and wear and adjust it in accordance with the VOLVO
Day-to-day addition of coolant is done from the recovery tank. When adding coolant to the radiator, DO NOT remove the radiator cap until the unit has completely cooled. See Table 11 for engine, radiator, and recovery tank coolant
Engine Owner's Manual.
The fan belt tension is proper if the fan belt bends 10 to 15 mm (Figure 36) when depressed with the thumb as shown below.
capacities. Make sure the coolant level in the recovery tank is always between the "H" and the "L" markings.
battery terminal disconnected.
yticapaCtnalooC.11elbaT
rotaidaRdnaenignE)sretil81(.laG8.4
knaTevreseR)sretil9.1(strauQ2
Operation Freezing Weather
When operating in freezing weather, be certain the proper amount of antifreeze (Table 12) has been added.
ezeerF-itnA.21elbaT
serutarepmeTgnitarepO
tnioPgnizeerF
less than 50%.
NOTE
%loV
ezeerF-itnA
C°F°
0573-43-
When the antifreeze is mixed with water, the antifreeze mixing ratio
must be
Figure 36. Fan Belt Tension
CAUTION - ROTATING PARTS
NEVER place hands near
the belts or fan while the generator set is running.
PAGE 34 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ)— PRE-SETUP
Battery
This unit is of negative ground DO NOT connect in reverse. Always maintain battery fluid level between the specified marks. Battery life will be shortened, if the fluid level are not properly maintained. Add only distilled water when replenishment is necessary.
DO NOT over fill. Check to see whether the battery cables are loose. Poor contact may result in poor starting or malfunctions. Coating the terminals with an approved battery terminal treatment compound. Replace battery with only recommended type battery. The battery type used in this generator is BCI Group 27.
The battery is sufficiently charged if the specific gravity of the battery fluid is 1.28 (at 68° F). If the specific gravity should fall to 1.245 or lower, it indicates that the battery is dead and needs to be recharged or replaced.
Before charging the battery with an external electric source, be sure to disconnect the battery cables.
Battery Cable Installation ALWAYS be sure the battery cables (Figure 37) are properly
connected to the battery terminals as shown below. The Red Cable is connected to the positive terminal of the battery,
and the Black Cable is connected to the negative terminal of the battery.
CAUTION - BATTERY SERVICING SAFETY
Always
keep the terminals firmly tightened.
When connecting battery do the following:
1. NEVER connect the battery cables to the battery
terminals when the the MANUAL position. ALWAYS make sure that the
Control Switch
connecting the battery.
2. Place a small amount of battery terminal treatment
compound around both battery terminals. This will ensure a good connection and will help prevent corrosion around the battery terminals.
NOTE
CAUTION - BATTERY SERVICING SAFETY
Inadequate battery connections may cause poor starting of the generator, and create other malfunctions.
Alternator
The polarity of the alternator is negative grounding type. When an inverted circuit connection takes place, the circuit will be in short circuit instantaneously resulting the alternator failure.
MPEC Control Switch
is in either
MPEC
is in the OFF/RESET position when
If the battery cable is connected incorrectly, electrical damage to the generator will occur. Pay close attention to the polarity of the battery when connecting the battery.
ALWAYS
reconnect negative terminal LAST.
disconnect the negative terminal FIRST and
Figure 37. Battery Connections
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 35
DO NOT put water directly on the alternator. Entry of water
into the alternator can cause corrision and damage the alternator.
Wiring
Inspect the entire generator for bad or worn electrical wiring or connections. If any wiring or connections are exposed (insulation missing) replace wiring immediately.
Piping and Hose Connection
Inspect all piping, oil hose, and fuel hose connections for wear and tightness. Tighten all hose clamps and check hoses for leaks.
If any hose ( immediately.
fuel
or
oil
) lines are defective replace them
1
DCA-220SSVU (50 HZ)— GENERATOR START-UP PROCEDURE (MANUAL)
Before Starting
CAUTION - LETHAL EXHAUST HAZARD
Starting (Manual)
1. In cold weather conditions, press and hold the
button
The engine's exhaust contains harmful emissions.
ALWAYS have adequate ventilation when operating
Direct exhaust away from nearby personnel.
WARNING - STARTING THE GENERATOR
NEVER!
or
1. Place the
manually start the engine with the
auxiliary
(Figure 38) in the OFF position prior to starting the engine.
circuit breakers in the ON (closed) position.
main, G.F.C.I.,
and
aux.
main, GFCI
circuit breakers
.
engine glow plugs.
2. Place the engine speed switch (Figure 41) in the “ (down) position.
3. Once the engine glow plugs have been warmed, place
the start the engine (Figure 42).
pre-heat
(Figure 40) for at least 50 seconds to warm the
Figure 42. Pre-Heat Button
LOW
Figure 41. Engine Speed Switch (Low)
MPEC Control Switch
in the MANUAL position to
Figure 38. Main, Aux. and GFCI
Circuit Breakers (OFF)
2. Make sure the the been configured for the desired output voltage.
3. Connect the load to the
terminal lugs
connection points can be found on the output terminal panel and the output terminal panel’s hard wire hookup panel.
4. The output terminal lugs are protected by a plastic cover. Remove this cover to gain access to the terminals. Tighten terminal nuts securely to prevent load wires from slipping out.
5. Close all engine enclosure doors (Figure 39).
voltage change-over board
receptacles or
as shown in Figure 13. These load
the
has
output
4. Once the engine starts, let it engine run for 1-2 minutes.
5. Verify that the Engine Running
Figure 42. MPEC Control Switch
(Manual Position)
Listen for any abnormal noises. If any abnormalities exists shutdown the engine and correct the problem. If the engine is running smoothly, place the engine speed switch (Figure 43) in the
Figure 43. Engine Speed Switch (High)
status LED on the MPEC unit (Figure 44) is ON (lit) after the engine has been started.
HIGH
(up) position.
Figure 39. Engine Enclosure Doors
PAGE 36 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
Figure 44. Engine Running LED (ON)
DCA-220SSVU (50 HZ)— GENERATOR START-UP PROCEDURE (MANUAL)
6. The generator's frequency meter (Figure 45) should be displaying the 60 cycle output frequency in HERTZ.
Figure 45. Frequency Meter (Hz)
7. The generator's AC-voltmeter (Figure 47) will display the generator’s output in VOLTS. If the voltage is not within the specified tolerance, use the voltage adjustment control knob (Figure 47) to increase or decrease the desired voltage.
10. The (Figure 50) will indicate the coolant temperature. Under normal operating conditions the coolant temperature should be between 165 and 203 degrees Fahrenheit (
11. The will indicate the speed of the engine when the generator is operating. Under normal operating conditions this speed is approximately 1600 RPM’s.
12. Place the
ON position (Figure 52).
coolant temperature gauge
Green Zone
tachometer gauge
main, GFCI
).
Temperature Gauge
(Figure 51)
, and
aux
. circuit breakers in the
Figure 50. Coolant
Figure 51. Engine
Tachometer Gauge
Figure 46. Voltmeter
Figure 47. Voltage Adjust Control Knob
8. The ammeter (Figure 48) will indicate applied. When a load is applied, the ammeter will indicate the amount of current that the load is drawing from the generator.
9. The engine oil pressure gauge (Figure 49) will indicate the oil pressure of the engine. Under normal operating conditions the oil pressure is approximately 44 to 73 psi. (303~503 kPa). When starting the genera
zero amps
with no load
Figure 48. Ammeter
(No Load)
Figure 49. Oil
Pressure Gauge
Figure 52. Main, Aux. and GFCI
Circuit Breakers (ON)
13. Observe the generator's ammeter (Figure 53) and verify it reads the anticipated amount of current with respect to the load. The ammeter will only display a current reading if a load is in use.
Figure 53. Ammeter
(Load)
14. The generator will run until manually stopped or an abnormal condition occurs.
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 37
DCA-220SSVU (50 HZ)— GENERATOR START-UP PROCEDURE (AUTO MODE)
Starting (Auto Mode)
DANGER - ELECTRICAL SYSTEM HAZARDS
Before connecting this generator to any building’s electrical system, a
electrician (transfer)
building’s electrical system may occur without this transfer switch.
When connecting the generator to a isolation (transfer) switch, ALWAYS have power applied to the generator's internal battery charger. This will ensure that the engine will not fail due to a dead battery.
NOTE
must install an
switch
CAUTION - BACKUP GENERATOR USE
. Serious damage to the
When the generator is set in the
AUTO mode, the generator will
automically start
comercial power falling below a prescribed level by means of a contact closure that is generated automatically by a transfer switch.
licensed
isolation
in the event of
When starting generator in AUTO mode use the " Start-up" procedure except where noted (see below).
1. Perform steps 1 through 5 in the as outlined in the
2. Place the position
3. Place the position
4. Continue operating the generator as s outlined in the
Manual Start-up
Manual
Before Starting
Manual Starting Procedure
engine speed switch
Figure 54. Engine Speed Switch (High)
MPEC Control Switch
Figure 55. MPEC Control Switch (AUTO)
procedure (start at step 5).
(Figure 54) in the HIGH
(Figure 55) in the AUTO
section .
WARNING - AUTO MODE MAINTENANCE
When running the generator in the AUTO mode, remember the generator can start up at any time without warning. NEVER attempt to perform any maintenance when the generator is in the auto mode.
CAUTION - ENGINE SPEED SWITCH
The
Engine Speed Switch
position when running in the set the switch in the proper position can result in damage to your generator when it turns on.
NOTE
must be set to the “High
Auto-Start
When the MPEC is placed in the AUTO position,
the engine glow plugs will be warmed and the engine will start automatically.
mode. Failing to
Control Switch
PAGE 38 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ)— GENERATOR SHUT-DOWN PROCEDURES
WARNING -
NEVER stop the engine suddenly except in an emergency.
Normal Shutdown Procedure
To shutdown the generator use the following procedure:
1. Place both the MAIN, GFCI and LOAD circuit breakers as shown in Figure 38 to the OFF position.
2. Place the engine speed switch (Figure 56) in the “
(down) position.
Figure 56. Engine Speed Switch (Low)
3. Let the engine cool by running it at low speed for 3-5 minutes with no load applied.
4. Place the
OFF/RESET position.
SHUTTING DOWN THE GENERATOR
MPEC Control Switch
(Figure 57) to the
LOW
Emergency Shutdown Procedure
1. To shut-down the engine in the event of an emergency, switch the breakers to OFF position.
2. Place the the OFF/RESET position.
MAIN, GFCI
MPEC Control Switch
and
LOAD
(Figure 38) circuit
switch (Figure 57) to
Figure 57. MPEC Control Switch (Off/Reset)
5. Verify that the are OFF (not lit).
6. Remove all loads from the generator.
7. Inspect entire generator for any damage or loosening of components that may have occured during operation.
all
status LED on the MPEC display
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 39
DCA-220SSVU (50 HZ)— MAINTENANCE
ECNANETNIAM/NOITCEPSNI.31ELBAT
sleveLdiulFenignEkcehC X
renaelCriAkcehC X
leveLdicAyrettaBkcehC X
noitidnoCtleBnaFkcehC X
skaeLrofkcehC X
straPfogninesooLrofkcehC X
1
*retliFdnaliOenignEecalpeR
ENIGNE
ROTARENEG
retliFriAnaelC X
lwoBrotarepeSretaW/retliFleuFkcehC X
edistuOdnaedisnI,tinUnaelC X
retliFleuFegnahC X
2
*leveLnoitcetorPtnalooCkcehCdnarotaidaRnaelC
3
*tnemelEretliFriAecalpeR
4
*spmalCdnasesoHllakcehC
knaTleuFfoedisnInaelC X
smhoM3revOecnatsiseRnoitalusnIerusaeM X
gniraeBtroppuSraeRrotoRkcehC X
.lioro/dnaerutsiomtcellocdluoctahtspidrosgason
srH01
YLIAD
.ylnoemittsrif,sruoh001taretliffnalioenigneecalpeR1*
srH052 srH005 srH0001
X
X
X
.tnaloocenigneehtegrahcerot")S'ACS(sevitaddAtnalooClatnemelppuS"ddA2*
X
H.ni52(mm526fomuccavaswohsrotacidninoitcirtsernehwtnemeleretlifriayramirpecalpeR3*
2
.)0
htiw,toofrephcni2/1atsaeltasiesohybolbehtfoepolsehttahterusne,decalperebotsdeenesohybwolbfI4*
General Inspection
Prior to each use, the generator should be cleaned and inspected for deficiencies. Check for loose, missing or damaged nuts, bolts or other fasteners. Also check for fuel, oil, and coolant leaks. Use Table 13 as a general maintenance guideline Engine Side (Refer to the Engine Instruction Manual)
Air Cleaner
Every 250 hours: Remove air cleaner element and clean the heavy duty paper element with light spray of compressed air. Replace the air cleaner as needed.
Air Cleaner with Dust Indicator
This indicator is attached to the air cleaner. When the air cleaner element is clogged, air intake restriction becomes greater and the dust indicator signal shows RED meaning the element needs changing or service. After changing the air element, press the dust indicator button to reset the
Service Daily
If the engine is operating in very conditions, a clogged air cleaner will result. This can lead to a loss of power, excessive carbon buildup in the combustion chamber and high fuel consumption. Change air cleaner more
frequently
Fuel Addition
Add diesel fuel (the grade may vary according to season and locations).
Removing Water from the Fuel Tank
After prolonged use, water and other impurities accumulate in the bottom of the tank. Occasionally inspect the fuel tank for water contamination and drain the contents if required.
During cold weather, the more empty volume inside the tank, the easier it is for water to condense. This can be reduced by keeping the tank full with diesel fuel.
indicator.
PAGE 40 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
dusty
or
if these conditions exists.
dry grass
DCA-220SSVU (50 HZ)— MAINTENANCE
Air Removal
If air enters the fuel injection system of a diesel engine, starting becomes impossible. After running out of fuel, or after disassembling the fuel system, bleed the system according to the following procedure. See the
Manual
To restart after running out of fuel, turn the switch to the “ON” position for 15-30 seconds. Try again, if needed. This unit is equipped with an automatic air bleeding system.
Check Oil Level
Check the crankcase oil level prior to each use, or when the fuel tank is filled. Insufficient oil may cause severe damage to the engine. Make sure the generator is level. The oil level must be between the two notches on the dipstick as shown in Figure 31.
Replacing Oil Filter
for details.
Remove the old oil filter. Apply a film of oil to the gasket on the new oil filter. Install the new oil filter. After the oil cartridge has been replaced, the engine oil
will drop slightly. Run the engine for a while and check for leaks before adding more oil if needed. Clean excessive oil from engine.
VOLVO Engine
Flushing Out Radiator and Replacing Coolant
Open both cocks located at the crankcase side and at the lower part of the radiator and drain coolant. Open the radiator cap while draining. Remove the overflow tank and drain.
Check hoses for softening and kinks. Check clamps for signs of leakage.
Flush the radiator by running clean tap water through radiator until signs of rust and dirt are removed. DO NOT clean radiator core with any objects, such as a screwdriver.
Tighten both cocks and replace the overflow tank. Replace with coolant as recommended by the engine
manufaturer. Close radiator cap tightly.
WARNING - BURN HAZARDS
Allow engine to radiator. Flushing the radiator while hot could cause serious burns from water or steam.
Generator Storage
cool
when flushing out
Cleaning the Fuel Strainer
Clean the fuel strainer if it contains dust or water. Remove dust or water in the strainer cap and wash it in gasoline. Securely fasten the fuel strainer cap so that fuel will not leak. Check the fuel strainer every 200 hours of operation or once a month.
Replacing Fuel Filter
Replace the fuel filter cartridge with new one every 500 hours or so.
Loosen the drain plug at the lower top of the fuel filter. Drain the fuel in the fuel body together with the mixed water. DO NOT spill the fuel during disassembly.
Vent any air.
For longe term storage of the generator the following is recommended:
Fill the fuel tank completely. Treat with a fuel stabilizer if necessary.
Completely drain the oil from the crankcase and refill if necessary with fresh oil.
Clean the entire generator, internal and external. Cover the generating set and store in a clean, dry place. Disconnect the battery. Make sure engine coolant is at proper level. If generator is mounted on a trailer, jack trailer up and
place on blocks so tires do not touch the ground or block and completely remove the tires.
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 41
DCA-220SSVU (50 HZ)— MAINTENANCE
Jacket Water Heater and Internal Battery Charger 120 VAC Input Receptacles (OPTIONAL)
This generator can be optionally equipped with two 120 VAC, 20 amp input receptacles located on the output terminal panel.
The purpose of these receptacles is to provide power via commercial power to the
battery charger
These receptacles will ONLY function when commercial power has been supplied to them (Figure 58). To apply commercial power to these receptacles, a power cord of adequate size will be required (See Table 6).
When using the generator in to apply power to jacket water heater. However, if the generator will be used in idea to apply power to the jacket water heater at all times. To apply power to the jacket water heater simply apply power to the jacket water heater receptacle via commercial power using an power cord of adequate size.
.
jacket water heater
hot
climates there is no reason
cold
climates it is always a good
and
internal
If the generator will be used daily, the battery should normally not require charging. If the generator will be idle (not used) for long periods of time, apply power to the battery charger receptacle via commercial power using an power cord of adequate size.
NOTE
To ensure adequate starting capability, always have power applied to the generator's
internal battery charger
.
Figure 56. DCA-45SIU2 Battery Charger &
Jacket Water Heater Power Connections
PAGE 42 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ)— TRAILER MAINTENANCE
Trailer Maintenance
This section is intended to provide the user with generic trailer service and maintenance information. The service and maintenance guidelines referenced in this section refer to a wide range of trailers.
Remember periodic inspection of the trailer will ensure safe towing of the generator and will prevent personal injury and damage to the equipment.
The definitions below describe some of the major components of a typical trailer that would be used with the DCA-220SSVU
(50 HZ)Whisperwatt
1. Fuel Cell - Provides an adequate amount of fuel for the equipment in use. Fuel cells must be empty when trans­porting equipment.
2. Braking System - System employed in stopping the trailer. Typical braking systems are electric, surge, hy­draulic, hydraulic-surge and air.
3. GVWR- Gross Vehicle Weight Rating (GVWR) is the maximum number of pounds the trailer can carry, in­cluding the fuel cell (empty).
4. Frame Length - Measurement is from the ball hitch to the rear bumper (reflector).
5. Frame Width - Measurement is from fender to fender
Generator.
7. Coupler - Type of hitch used on the trailer for towing.
8. Tire Size - Indicates the diameter of the tire in inches (10,12,14, etc.), and the width in millimeters (175,185,205, etc.). The tire diameter must match the diameter of the tire rim.
9. Tire Ply - The tire ply (layers) number is rated in letters; 2-ply,4-ply,6-ply, etc.
10. Wheel Hub - The wheel hub is connected to the trailer’s axle.
11. Tire Rim - Tires mounted on a tire rim. The tire rim must match the size of the tire.
12. Lug Nuts - Used to secure the wheel to the wheel hub. Always use a torque wrench to tighten down the lug nuts. See Table 16 and Figure 59 for lug nut tightening and sequence.
13. Axle - Indicates the maximum weight the axle can sup- port in pounds, and the diameter of the axle expressed in inches. Please note that some trailers have a double axle. This will be shown as 2-6000 lbs., meaning two axles with a total weight capacity of 6000 pounds.
14. Suspension - Protects the trailer chassis from shocks transmitted through the wheels. Types of suspension used are leaf, Q-flex, and air ride.
6. Jack Stand - Trailer support device with maximum pound requirement from the tongue of the trailer.
7. Coupler - Type of hitch used on the trailer for towing.
15. Electrical - Electrical connectors (looms) are provided with the trailer so the brake lights and turn signals can be connected to the towing vehicle.
16. Application - Indicates which units can be employed on a particular trailer.
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 43
DCA-220SSVU (50 HZ)— TRAILER MAINTENANCE
Brakes
Trailer brakes should be inspected the
first 200 miles
operation. This will allow the brake shoes and drums to seat properly. After the first 200 mile interval, inspect the brakes
every 3,000 miles
. If driving over rough terrain, inspect the
Hydraulic Surge Brakes
of
Hydraulic surge brakes (Figure 59) should not require any special attention with the exception of routine maintenance such as shoe and lining replacement. Brake lines should be periodically checked for cracks, kinks, or blockage.
brakes more frequently. Figure 59 displays the major hydraulic surge brake
components that will require inspection and maintenance. Please inspect these components as required using steps 1 through 8 and Table 14 as listed below:
Brake Adjustment
1. Place the trailer on jack stands. Make sure the jack stands are placed on secure level ground.
2. Check the wheel and drum for free rotation.
3. Remove the adjusting hole cover from the adjusting slot at the bottom brake backing plate.
4. With a screwdriver or standard adjusting tool, rotate the
Figure 59. Hydraulic Brake Components
star wheel of the adjuster assembly to expand the brake shoes.
Actuator
5. Adjust the brake shoes outward until the pressure of the lining against the wheel drum makes the wheel difficult to turn.
6. Adjust, rotate the star wheel in the opposite direction until the wheel rotates freely with slight lining drag.
Hydraulic surge braking requires the installation of an actuator at the tongue of the trailer. Remember the the trailer toward the tow vehicle automatically synchronizes the trailer brakes with the tow vehicle brakes. As the trailer pushes against the tow vehicle the actuator telescopes together and applies force to the master cylinder, supplying
7. Replace the adjusting hole cover and lower the trailer to
hydraulic pressure to the trailer brakes.
the ground.
Periodically check and test the surge “
8. Repeat steps 1 through 7 on the remaining brakes.
sure that it is functioning correctly. Never use an undersize actuator.
motpmyS esuaCelbissoP noituloS
sekarBoN?deknikronekorbenilekarB.ecalperroriapeR
rB.ecalperrohsinrubeR
otlluPsekarBrosekarBkaeW
ediSenO
sekarBgnikcoL
sekarBysioN
sekarBgniggarD
tsujda
?dezalggninileka
?dedaolrevoreliarT.thgiewtcerroC
?tcerroc
erusserperiT.yllauqeseritllaetalfnI
oolstnenopmocekarB.stnenopmocecalpeR
?detacirbulmetsyS.etacirbu
?yltcerrocde
gnitoohselbuorTekarBciluardyH.41elbaT
?devoorgroderocssmurdekarB.ecalperroenihcaM
?elxaemasehtnodehctamnuseriT.serithctaM
?nekorbrotneb,es
?dnuor-fo-tuosmurdekarB.ecalpeR
?tcerrocstnenopmocekarB.tcerrocdnaecalpeR
tonrotcerrocnissenkcihtgninilekarB
?diulftcerrocrodiulfekarbhguonE
surge
or
push
of
actuator
L
dnaseohswenllatsnI
.sgninil
straprebburecalpeR
.diulf4todhtiwllif
” to make
PAGE 44 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ)— TRAILER MAINTENANCE
Tires/Wheels/Lug Nuts
Tires and wheels are a very important and critical components of the trailer. When specifying or replacing the trailer wheels it is important the wheels, tires, and axle are properly matched.
Suspension
leaf suspension
The (Figure 60) should be visually inspected every 6,000 miles for signs of excessive wear, elongation of bolt holes, and loosening of fasteners. Replace all damaged parts (suspension) immediately. Torqued suspension components
CAUTION - EYESIGHT HAZARD
ALWAYS
wear safety glasses when
as detailed in Table 16.
removing or installing force fitted parts. Failure to comply may result in serious injury.
CAUTION - REPAIRING TRAILER WHEELS
DO NOT attempt to repair or modify a wheel. DO NOT
install in inner tube to correct a leak through the rim. If the rim is cracked, the air pressure in the inner tube may cause pieces of the rim to explode (break off) with great force and cause serious eye or bodily injury.
springs and associated components
Figure 60. Major Suspension Components
Tire Wear/Inflation
Tire inflation pressure is the most important factor in tire life. Pressure should be checked cold before operation DO NOT bleed air from tires when they are
hot!
. Check inflation pressure weekly during use to insure the maximum tire life and tread wear.
Table 15 (Tire Wear Troubleshooting) will help pinpoint the causes and solutions of tire wear problems.
SHACKLE BOLT
SPRING EYE BOLT
SHOULDER TYPE
SHACKLE BOLT
metI ).sbL-.tF(euqroT
TLOB-U"8/353-XAM03-NIM
TLOB-U"61/706-XAM54-NIM
TLOB-U"2/106-XAM54-NIM
SNUG FIT ONLY
LOCKING NUTS OR COTTER PINS ARE PROVIDED
TO RETAIN NUT
stnemeriuqeReuqroTnoisnepsuS.61elbaT
.
PARTS MUST ROTATE FREELY
-
BOLT ASSEMBLY
.
05-XAM03-NIM
.
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 45
DCA-220SSVU (50 HZ)— TRAILER MAINTENANCE
Lug Nut Torque Requirements
It is extremely important to apply and maintain proper wheel mounting torque on the trailer. Be sure to use only the fasteners matched to the cone angle of the wheel. Proper procedure for attachment of the wheels is as follows:
1. Start all wheel lug nuts by hand.
2. Torque all lug nuts in sequence (see Figure 61). DO NOT torque the wheel lug nuts all the way down. Tighten each lug nut in 3 separate passes as defined by Table 17.
3. After first road use, retorque all lug nuts in sequence. Check all wheel lug nuts periodically.
stnemeriuqeReuqroTeriT.71elbaT
eziSleehWssaPtsriF
SBL-TF
"2152-0204-5356-05
152-0204-5356-05
"3
"4152-0206-05021-09
"5152-0206-05021-09
"6152-0206-05021-09
ssaPdnoceS
SBL-TF
ssaPdrihT
SBL-TF
Figure 61. Wheel Lug Nuts
Tightening Sequence
NOTE
NEVER
use an pneumatic air
gun to tighten wheel lug nuts.
PAGE 46 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ)— TRAILER WIRING DIAGRAM
Figure 62. Trailer/Towing Vehicle Wiring Diagram
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 47
DCA-220SSVU (50 HZ)— GENERATOR WIRING DIAGRAM
Figure 63. Generator Wiring Diagram
PAGE 48 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ) — ENGINE WIRING DIAGRAM
Figure 64. Engine Wiring Diagram
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 49
1
DCA-220SSVU (50 HZ)— TROUBLESHOOTING (GENERATOR)
Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use Table 18 shown below for diagnosis of the Generator. If the problem cannot be remedied, consult our company's business office or service plant.
GNITOOHSELBUORTROTARENEG.81ELBAT
MOTPMYS MELBORPELBISSOP NOITULOS
tuptuOegatloVoN ?evitcefedretemtloVCA .retemtlovagnisuegatlovtuptuokcehC
?esoolnoitcennocgniriwsI .riaperdnagniriwkcehC
?evitcefedRVAsI .yrassecenfiecalpeR
?reifitceRgnitatoRevitcefeD .ecalperdnakcehC
?dleiFreticxEevitcefeD 1NCnoK&Jssorcasmho3.71rofkcehC
tuptuOegatloVwoL ?tcerrocdeepsenignesI ."hgiH"otrevelelttorhtenignenruT
?esoolsnoitcennocgniriwsI .riaperdnagniriwkcehC
?RVAevitcefeD .yrassecenfiecalpeR
tuptuOegatloVhgiH ?esoolsnoitcennocgniriwsI .riaperdnagniriwkcehC
?RVAevitcefeD .yrassecenfiecalpeR
deppirTrekaerBtiucriC ?daolnitiucriCtrohS .riaperdnadaolkcehC
?tnerrucrevO .ecuderdnastnemeriuqerdaolmrifnoC
?rekaerbtiucricevitcefeD .ecalperdnakcehC
?detautcayaleRtnerrucrevO .ecalperdnatnemeriuqerdaolmrifnoC
PAGE 50 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ)— TROUBLESHOOTING (ENGINE CONTROLLER)
Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use Table 19 (Engine Controller Troubleshooting) as a basic guideline for troubleshooting the Microprocessor Engine Controller unit (MPEC). If the problem cannot be remedied, consult our company's business office or service plant.
)CEPM(GNITOOHSELBUORTRELLORTNOCENIGNE.91ELBAT
MOTPMYS MELBORPELBISSOP NOITULOS
?levelliowoL.levelliolliF
sithgilerusserpliowoL
.no
?detrohseriW.eriwriaper/tcepsnI
?leveltnaloocwoL.leveltnalooclliF
ltnaloocwoL
.nosithgil
sithgilleve )dellatsnIyllanoitpO(.no
erutrepmettnaloochgiH
?eruliaftinugnidneS .tinugnidnesecalpeR
?egatlovyrettabwoL .yrettabegrahc/ecalpeR
?neposrooD.srood
?gnikaeltsuahxE .trapytluafrosteksagriaper/ecalpeR
?eruli
aftatsomrehT.tatsomrehtecalpeR
?dekcolbekatniriA.sekatniriallaraelC
?eruliaftinugnidneserusserpliO .tinugnidneseru
?rellortnoCninoitnuflamyaledemiT.relaedotrefeR
?tcerrocninoisnettlebnaF .t
?rotaidarhguorhtnoitalucrictonsiwolfriA .llirgrotaidarriaper/naelC
esolC
?dedaolrevogniebrotareneG.daolecuder/kcehC
?eruliafhctiwserutarepmeT .hctiwseruta
sserplioecalpeR
lebnafecalper/nethgiT
repmetecalpeR
?leuFwolrooN.levelleuflliF
.nosithgilknarcrevO
?detarbilacebotsdeenrellortnoC.relaedotrefeR
?hgihootdeepsenigneMPR.MPRtsujdA
?detsujdaebotsdeenrotautcaronrevoG .rotautcaronrevogt
.
nosithgildeepsrevO
?detsujdaebotsdeenrellortnocronrevoG .rellortnocronrevogtsujdA
E.relaedotrefeR
ro)s(thgilUPMfossoL
.no
tengaM .pukcipcitengamnaelC
?ytridpukcipci
?detarbilacebotsdeenrellortnoCenign
?tnemtsujdafotuopukcipcitengaM .pukcipcitengamtsujdA
sujdA
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 51
DCA-220SSVU (50 HZ) — EXPLANATION OF CODE IN REMARKS COLUMN
The following section explains the different symbols and remarks used in the Parts section of this manual. Use the help numbers found on the back page of the manual if there are any questions.
The contents and part numbers listed in the parts section are subject to change guarantee the availibility of the parts listed.
Sample Parts List:
NO. PART NO. PART NAME QTY. REMARKS
1 12345 BOLT ....................... 1 .... INCLUDES ITEMS W/
2
*
2*12347 WASHER, 3/8 IN. ....1 ....
3 12348 HOSE .................... A/R .. MAKE LOCALLY
4 12349 BEARING ................ 1 .... S/N 2345B AND ABOVE
NO. Column
Unique Symbols - All items with same unique symbol
, #, +, %, or >) in the number column belong to the same
(
*
assembly or kit, which is indicated by a note in the “Remarks” column.
Duplicate Item Numbers - Duplicate numbers indicate multiple part numbers are in effect for the same general item, such as different size saw blade guards in use or a part that has been updated on newer versions of the same machine.
NOTE
without notice
WASHER, 1/4 IN. ...........
When ordering a part that has more than one item number listed, check the remarks column for help in determining the proper part to order.
. Multiquip does not
NOT SOLD SEPARATELY MQ-45T ONLY
QTY. Column
Numbers Used - Item quantity can be indicated by a number,
a blank entry, or A/R. A/R (As Required) is generally used for hoses or other parts
that are sold in bulk and cut to length. A blank entry generally indicates that the item is not sold
separately. Other entries will be clarified in the “Remarks” Column.
REMARKS Column
Some of the most common notes found in the “Remarks”
*
Column are listed below. Other additional notes needed to describe the item can also be shown.
Assembly/Kit
symbol will be included when this item is purchased. Indicated by:
“INCLUDES ITEMS W/(unique symbol)”
Serial Number Break
range where a particular part is used. Indicated by:
“S/N XXXXX AND BELOW” “S/N XXXX AND ABOVE” “S/N XXXX TO S/N XXX”
Specific Model Number Use
only with the specific model number or model number variant listed. It can also be used to show a part is NOT used on a specific model or model number variant.
Indicated by:
“XXXXX ONLY” “NOT USED ON XXXX”
- All items on the parts list with the same unique
- Used to list an effective serial number
- Indicates that the part is used
PART NO. Column
Numbers Used - Part numbers can be indicated by a number,
a blank entry, or TBD. TBD (To Be Determined) is generally used to show a part
that has not been assigned a formal part number at time of publication.
A blank entry generally indicates that the item is not sold separately or is not sold by Multiquip. Other entries will be clarified in the “Remarks” Column.
PAGE 52 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
“Make/Obtain Locally”
purchased at any hardware shop or made out of available items. Examples include battery cables, shims, and certain washers and nuts.
“Not Sold Separately”
purchased as a separate item and is either part of an assembly/kit that can be purchased, or is not available for sale through Multiquip.
- Indicates that the part can be
- Indicates that an item cannot be
DCA-220SSVU (50 HZ)— SUGGESTED SPARE PARTS
DCA-220SSVU (50 HZ)WHISPER WATTGENRATOR
W/VOLVO PENTA TAD741GE DIESEL ENGINE
1 TO 3 UNITS
Qty. P/N Description
1 ......... V3827051 ............ HOSE, RADIATOR UPPER
1 ......... V3827052 ............ HOSE, RADIATOR LOWER
1 ......... V866095 .............. RADIATOR CAP
1 ......... 0605505070 ........ FUEL CAP
1 ......... V966846 .............. V-BELT SET, MAIN S/N 2071145377 AND BELOW
1 ......... V966847 .............. V-BELT SET, MAIN S/N 2071145378 AND ABOVE
1 ......... V873771 .............. ALTERNATOR 12 VDC
1 ......... V9146844 ............ V-BELT, ALTERNATOR
1 ......... V863169 .............. MONITOR, OIL PRESSURE
1 ......... V866835 .............. SENSOR, OIL PRESSURE
1 ......... V848829 .............. TEMP SENSOR UNIT
1 ......... V862154 .............. SWITCH, TEMPERATURE SENSOR
1 ......... V8488229 ............ SENSOR, TEMPERATURE
6 ......... V3825133 ............ FILTER, FUEL
6 ......... V8159975 ............ FILTER, WATER SEPARATOR
6 ......... V466634 .............. FILTER, OIL CARTRIDGE
6 ......... V477556 .............. FILTER, OIL CARTRIDGE BI-PASS
3 ......... V3827589 ............ FILTER, AIR (ELEMENT)
1 ......... 0601870420 ........ CIRCUIT BREAKER
2 ......... LY2DUS24VDC ... RELAY
Part number on this Suggested Spare Parts list
NOTE
may supercede/replace the P/N shown in the text pages of this book.
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 53
GENERATOR ASSY.
DCA-220SSVU (50 HZ)— GENERATOR ASSY.
PAGE 54 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ)— GENERATOR ASSY.
GENERATOR ASSY.
NO. PART NO. PART NAME QTY. REMARKS
1 C1110000002 ROTOR ASSEMBLY .................................. 1 ............. INCLUDES ITEMS W/
1-1
*
1-2 1-3 1-4 1-4A 0040005000 SPRING WASHER 2 1-4B 0041205000 PLAIN WASHER 2 1-5 8171070002 FAN 1 1-6 8171611003 COUPLING DISK 9 1-7 C1164200004 WASHER, COUPLING HUB 1
1-8 8171015003 BALANCING PLATE .................................. 1 ............. PURCHASE ITEM 1-11 AS A SET
1-9 012116045 HEX. HEAD BOLT 8 1-10 0042616000 SPRING WASHER 8 1-11 0601000209 BALANCING WEIGHT KIT 1 1-12 C1112500004 BEARING FLANGE 1 1-13 0071906314 BEARING, 6314DDU C3 1 2 M4163400003 COUPLING RING 1 3 0343206120 HEX. HEAD BOLT 8 4 0043606000 SPRING WSHER 8 5 0012112040 HEX. HEAD BOLT 8 6 0042512000 SPRING WASHER 8
7 C1130100103 STATOR ASSEMBLY ................................. 1 ............. INCLUDES ITEMS W/#
7-1# 0226100420 RUBBER SEAL 1 7-2# 8171323004 CLAMPER 1 7-3# 0223300120 RUBBER SEAL 1 7-4# 8171323103 CLAMPER 1 7-5# 0221200300 RUBBER SEAL 1 7-6# 0010110035 HEX. HEAD BOLT 2 7-7# 0041210000 PLAIN WASHER 2 7-8# C1132200003 COVER 1 7-9# 0226000510 RUBBER SEAL 1 7-10# 0225000470 RUBBER SEAL 1 7-11# 0017106016 HEX. HEAD BOLT 6 7-12# 0601850144 GROMMET 1 8 C1154999992 END BRACKET 1 9 C1138000003 FIELD ASSEMBLY, EXCITER 1
0601842334 RESISTOR, 80W 100K OHM 1
*
0601823282 RECTIFIER, RM50TC- 24 1
*
0018205020 HEX. SOCKET HEAD CAP SCREW 2
*
FIELD ASSEMBLY 1
*
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 55
GENERATOR ASSY.
DCA-220SSVU (50 HZ)— GENERATOR ASSY. (CONT.)
PAGE 56 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU (50 HZ)— GENERATOR ASSY. (CONT.)
GENERATOR ASSY. (CONT.)
NO. PART NO. PART NAME QTY. REMARKS
10 0012110065 HEX. HEAD BOLT 4 10A 0042610000 SPRING WASHER 4 10B 0041210000 PLAIN WASHER 4 11 0017112045 HEX. HEAD BOLT 6 12 C1154400004 COVER, BEARING 1 13 C1154300004 GASKET, BEARING 1 14 0010106060 HEX. HEAD BOLT 4 14A 0040006000 SPRING WASHER 4 14B 0041206000 PLAIN WASHER 4 15 C1154400103 SUCTION COVER 1 16 0017106016 HEX. HEAD BOLT 8 17 0343205150 HEX. HEAD BOLT 12 18 0043605000 SPRING WASHER 12 19 C1132300114 COVER, FAN 1 20 0010106030 HEX. HEAD BOLT 1 20A 0041206000 PLAIN WASHER 1 20B 0600815000 NUT 1 21 0605000012 RUBBER SUSPENSION 2 22 0030020000 HEX. NUT 4 22A 0040020000 SPRING WASHER 4 23 0070506907 BEARING, 6907ZZ 1
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 57
CONTROL PANEL ASSY.
DCA-220SSVU— CONTROL PANEL ASSY.
PAGE 58 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU— CONTROL PANEL ASSY.
CONTROL PANEL ASSY.
NO. PART NO. PART NAME QTY. REMARKS
1 M4223000013 CONTROL PANEL 1 2 M4223000203 CONTROL PANEL 1 3 0605011211 PIN 2 4 0016908035 HEX. HEAD BOLT 4 5 0601807642 FREQUENCY METER, 45 ~65 HZ 240V 1 6 0601808992 AC AMMETER, O~800A 1 7 0601801040 CHANGE- OVER SWITCH, AMMETER 1 8 0601800275 AC VOLTMETER, O~600V 1 9 0601801041 CHANGE- OVER SWITCH, VOLTMETER 1 10 0601840073 RHEOSTAT (VR), 2W 1K OHM 1 11 0601840121 KNOB 1
12 ECU9988N220V CONTROLLER, ECU ............................................ 1 ............. REPLACES P/N 0602202545
13 0601831340 SWITCH 1 14 0027104035 MACHINE SCREW 2 14A 0207004000 HEX. NUT 2 15 0601831395 ENGINE SPEED SWITCH 1 16 0601831585 PREHEAT BUTTON 1 17 0601831586 CAP 1 18 0602120096 TACHOMETER 1 19 0602122098 OIL PRESSEUR GAUGE 1 20 0602123096 WATER TEMPERATURE GAUGE 1 21 0602121080 CHARGING AMMETER 1 22 0602125091 FUEL GAUGE 1 23 0602103090 ALARM LAMP 1 24 0601810120 PANEL LIGHT 1 25 0601831330 SWITCH, PANEL LIGHT 1 26 M9220100004 SET SCREW 2 26A 0080200007 SNAP RING 2 27 0601842450 VOLTAGE DIVIDER 1 28 M4246700204 WIRE HARNESS, GENERATOR 1 29 M4357200032 WIRE HARNESS, ENGINE 1 30 0601802149 FUSE, 10A 1 31 0601802126 FUSE, 8A 1
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 59
CONTROL BOX ASSY.
DCA-220SSVU— CONTROL BOX ASSY.
PAGE 60 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU— CONTROL BOX ASSY.
CONTROL BOX ASSY.
NO. PART NO. PART NAME QTY. REMARKS
1 M4213000012 CONTROL BOX 1 2 0601809690 CURRENT TRANSFORMER 3 3 0027106016 MACHINE SCREW 6 4 0601870420 CIRCUIT BREAKER, 600A 1 5 0601815168 REAR CONNECTOR KIT 1 6 M421360024 SET PANEL, CIRCUIT BREAKER 1 7 0016908035 HEX. HEAD BOLT 4 8 M4273000003 TERMINAL BOARD, VOLTAGE CHANGE- OVER 1 9 M4276400004 CHANGE TERMINAL 10 10 0017106025 HEX. HEAD BOLT 20 11 M4276200004 TERMINAL PLATE 3 12 M4276300004 CHANGE- OVER PLATE 6 13 M9220100104 TIE BOLT 13 14 M9220100104 TIE BOLT 13 15 0040010000 SPRING WASHER 26 16 0041410000 PLAIN WASHER 26 17 0016900030 HEX. HEAD BOLT 4 18 0601820625 AUTOMATIC VOLTAGE REGULATOR 1 19 0027105016 MACHINE SCREW 4 20 0601820845 OVER CURRENT RELAY, LR2D1308 1 21 0601820846 OVER CURRENT RELAY, LA7D1064 1 22 0027104016 MACHINE SCREW 2 22A 0207004000 HEX. NUT 2 23 M4260600214 SET PANEL, ELECTRIC PARTS 1 24 0016908020 HEX. HEAD BOLT 4 25 0602202568 SPEED CONTROL UNIT 1 26 0027105016 MACHINE SCREW 4
27 0601821370 RECTIFIER ............................................................. 2 ......... REPLACES P/N 0601823240
28 0027104020 MACHINE SCREW 2
29 V1622515 COOLANT LEVEL SWITCH ................................... 1 ......... REPLACES P/N 0602202569
30 0027105035 MACHINE SCREW 1
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 61
CONTROL BOX ASSY. (CONT.)
DCA-220SSVU— CONTROL BOX ASSY. (CONT)
PAGE 62 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU— CONTROL BOX ASSY. (CONT)
CONTROL BOX ASSY. (CONT.)
NO. PART NO. PART NAME QTY. REMARKS
31 LY2DUS24VDC RELAY, 24VDC .................................................. 1 ........... REPLACES P/N 0601827655
31A 0601823109 RELAY BASE, PTF08A- E 1 31B 0601824400 RELAY CLIP, PYCA1 2 32 0601822060 TIMER RELAY, H3Y- 2 DC24V 10SEC 1 32A 0601823143 RELAY BASE, PYF08A 1 32B 0601824404 RELAY CLIP, Y92H-3 2 33 0601827684 RELAY, AHE1232 DC24V 1 34 0027104020 MACHINE SCREW 6 35 M4213600104 STOPPER, CONTROL PANEL 1 36 0041206000 PLAIN WASHER 1 37 0605010502 SNAP PIN 1 38 M4213500004 COVER, CONTROL BOX 1 39 0016908020 HEX. HEAD BOLT 8 40 M4213300004 SIDE PANEL, CONTROL BOX 1 41 0016908020 HEX. HEAD BOLT 4
42 M4213400004 BACK PANEL, CONTROL BOX ......................... 1 ...........S/N TBD
42 M4213400014 BACK PANEL, CONTROL BOX ......................... 1 ...........S/N TBD
43 0016908020 HEX.HEAD BOLT 8 44 0016910025 HEX. HEAD BOLT 4
45 0601842449 RESISTOR, 3.75KW 150 OHM .......................... 1 ...........S/N 8000001~8000019
45 0601842449 RESISTOR, 5W 150 OHM ................................. 1 ...........S/N 8000020 AND ABOVE
46 0027104010 MACHINE SCREW ............................................ 2 ........... S/N 8000020 AND ABOVE
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 63
ENGINE AND RADIATOR ASSY.
DCA-220SSVU— ENGINE AND RADIATOR ASSY.
PAGE 64 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU— ENGINE AND RADIATOR ASSY.
ENGINE AND RADIATOR ASSY.
NO. PART NO. PART NAME QTY. REMARKS
1 M4386200004 ENGINE & RAD. SET, TAD741GE ........... 1 .............. INCLUDES ITEMS W/
1-1
1-2*V466634 FILTER, OIL CARTRIDGE ....................... 1 .............. REPLACES P/N 0602041275
1-3*V477556 FILTER, OIL CARTRIDGE, BI- PASS...... 1 .............. REPLACES P/N 0602041276
1-4*V3825133 CARTRIDGE, FUEL FILTER ................... 2 .............. REPLACES P/N 0602042560
1-5*M4326200004 BREATHER PIPE 1 2 M4303200004 ENGINE FOOT 2 3 0012112040 HEX. HEAD BOLT 8 4 0030012000 SPRING WASHER 8 5 0605000011 RUBBER SUSPENSION 2 6 0030016000 HEX. NUT 4 7 0040016000 SPRING WASHER 4 8 0017112035 HEX. HEAD BOLT 4 9 0030012000 HEX. NUT 4 10 0040012000 SPRING WASHER 4 11 0041212000 PLAIN WASHER 4 12 M4310200004 BRACKET, RADIATOR 2 13 M4310200104 BRACKET, RADIATOR 2 14 0016908020 HEX. HEAD BOLT 4 15 0016910025 HEX. HEAD BOLT 4 16 0602022566 ADAPTER 1 17 0602022561 90 DEG. ELBOW 1 18 0603306590 CONNECTOR 1 19 0603300285 LOCKNUT 1 20 0605511395 VALVE 1 21 0603306395 HOSE JOINT 1 22 0602021070 CAP 1 23 0269200550 DRAIN HOSE 1 24 M4323500004 ADAPTER 1 25 0602012340 PACKING 1 26 0603306397 LONG NIPPLE 1 27 0603306497 90 DEG. ELBOW 1 28 0605511397 VALVE 1 29 0602022991 HOSE JOINT 1 30 0191300750 DRAIN HOSE 1
V3827589 ELEMENT, AIR FILTER ........................... 1 .............. REPLACES P/N 0602046620
*
*
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 65
ENGINE AND RADIATOR ASSY.
DCA-220SSVU— ENGINE AND RADIATOR ASSY.
PAGE 66 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU— ENGINE AND RADIATOR ASSY.
ENGINE AND RADIATOR ASSY.
NO. PART NO. PART NAME QTY. REMARKS
31 0605515109 HOSE BAND 1 32 0269401700 BLOWBY HOSE 1 33 0605515199 HOSE BAND 2 34 M4483600003 HOSE GUIDE 1 35 0016908020 HEX. HEAD BOLT 2 36 M4303200104 COVER 1 37 0193601700 OVER FLOW HOSE 1 40 V9146844 V-BELT, ALTERNATOR 1 41 V873771 ALTERNATOR 12 VOLT 1 42 V3183909 COOLANT PUMP 1 43 V469982 SEAL RING SET, COOLANT PUMP 1 44 V471629 SEAL RING, COOLANT PUMP 1 45 V925095 O-RING, COOLANT PUMP 1 46 V1661993 THERMOSTAT 1 47 V471788 SEALING RING, THERMOSTAT UPPER 1 48 V1544710 SEALING RING, THERMOSTAT LOWER 1 49 V925092 O-RING, THERMOSTAT HOUSING 1
50 V843869 FAN, RADIATOR ........................................... 1 ......... S/N 2071145377 AND BELOW
50 V3827492 FAN, RADIATOR ........................................... 1 ......... S/N 2071145378 AND ABOVE
51 V966846 V-BELT SET, MAIN ....................................... 1 ......... S/N 2071145377 AND BELOW
51 V966847 V-BELT SET, MAIN ....................................... 1 ......... S/N 2071145378 AND ABOVE
52 V866095 CAP, RADIATOR 1 53 V3827051 HOSE, RADIATOR UPPER 1 54 V847307 STARTER MOTOR STANDARD 1 55 V848829 SENSOR, TEMPERATURE 1 56 V11998 GASKET 2 57 V862154 SWITCH,TEMPERATURE SENSOR 1 58 V866835 SENSOR, OIL PRESSURE 1 59 V863169 MONITOR, OIL PRESSURE 1 60 V3825133 FILTER, FUEL 1 61 V3827052 HOSE, RADIATOR LOWER 1
62 V3827338 RADIATOR .................................................... 1 ......... S/N 2071145378 AND ABOVE
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 67
OUTPUT TERMINAL ASSY.
ADD THE FOLLOWING DIGITS AFTER THE PART NUMBER WHEN ORDERING ANY PAINTED PANEL TO INDICATE COLOR OF UNIT:
1-ORANGE 5-BLACK 2-WHITE 6-CATERPILLAR YELLOW 3-SPECTRUM GREY 7-CATO GOLD 4-SUNBELT GREEN 8-RED
THE SERIAL NUMBER MAY BE REQUIRED.
DCA-220SSVU— OUTPUT TERMINAL ASSY.
PAGE 68 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU— OUTPUT TERMINAL ASSY.
OUTPUT TERMINAL ASSY.
NO. PART NO. PART NAME QTY. REMARKS
1 M4230700003 TERMINAL BOARD 1 2 M9220100304 OUTPUT TERMINAL BOLT 8 3 M9220100404 TIE BOLT 8 4 0039316000 HEX. NUT 16 5 0040016000 SPRING WASHER 24 6 0041416000 PLAIN WASHER 32 7 M4233200004 TERMINAL PLATE 3 8 0016908040 HEX. HEAD BOLT 5 9 0601815194 TERMINAL BLOCK 1 10 0027104016 MACHINE SCREW 2 11 0601850275 GROMMET 1 12 0603306775 BLIND PLUG 2 13 0027104016 MACHINE SCREW 4 14 0601808803 CIRCUIT BREAKER, SINGLE-POLE 20A 2 15 0601808804 CIRCUIT BREAKER, DOUPLE-POLE 50A 3 16 M4260600104 BRACKET, CIRCUIT BREAKER 1 16-1 0222100150 RUBBER CUSHION 1 17 0016906020 HEX. HEAD BOLT 2 18 0601812598 RECEPTACLE, GFCI 20A 2 19 0601812538 RECEPTACLE, CS6369 50A 3 20 0027104016 MACHINE SCREW 10 20A 0207004000 HEX. NUT 10 21 M4236100103 TERMINAL COVER 1 22 0010112045 HEX. HEAD BOLT 2 23 0041212000 PLAIN WASHER 2 24 M9310200104 STAY RUBBER 2 25 0030012000 HEX. NUT 2 26 M9210000204 SPRING 2 27 M4236100004 COVER 1 28 0017110040 HEX. HEAD BOLT 2 29 M9116000004 COLLAR 1 30 M9310200004 STAY RUBBER 1 31 M4236100204 TERMINAL COVER 1 32 0016908020 HEX. HEAD BOLT 7
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 69
BATTERY ASSY.
DCA-220SSVU— BATTERY ASSY.
PAGE 70 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU— BATTERY ASSY.
BATTERY ASSY.
NO. PART NO. PART NAME QTY. REMARKS
1 0602220196 BATTERY 2 2 M9310500404 BATTERY SHEET 2 3 M9103000504 BATTERY BAND 2 4 0602220921 BATTERY BOLT SET 4 5 0040006000 SPRING WASHER 4 6 M4346900114 BATTERY CABLE 1 7 M4346400314 BATTERY CABLE 1 8 M4346900014 BATTERY CABLE 1
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 71
MUFFLER ASSY.
DCA-220SSVU— MUFFLER ASSY.
PAGE 72 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU— MUFFLER ASSY.
MUFFLER ASSY.
NO. PART NO. PART NAME QTY. REMARKS
1 M4330100002 MUFFLER 1 2 0016910025 HEX. HEAD BOLT 4 3 M4333000003 EXHAUST PIPE 1 4 V424628 GASKET 1 REPLACES P/N 0602320196 5 M4333200004 GASKET 1 6 0017112055 HEX. HEAD BOLT 4 7 M4330300004 COVER 2 8 0016908020 HEX. HEAD BOLT 4 9 M4333300004 BRACKET 1 10 0016908020 HEX. HEAD BOLT 4 11 0602326062 U-BOLT SET 1
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 73
FUEL TANK ASSY.
DCA-220SSVU— FUEL TANK ASSY.
PAGE 74 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU— FUEL TANK ASSY.
FUEL TANK ASSY.
NO. PART NO. PART NAME QTY. REMARKS
1 M4363000002 FUEL TANK 1 1-1 0605505070 CAP, FUEL TANK 1 2 M4363200004 TANK BAND 2 3 M9310500104 SUPPORTER SHEET 4 4 0016908020 HEX. HEAD BOLT 2 5 0207308000 HEX. NUT 2 6 0222100720 RUBBER SHEET 4 7 M9200000003 DRAIN JOINT 1 8 M9200200004 DRAIN BOLT 1 9 0150000018 O- RING 1 10 0016906020 HEX. HEAD BOLT 2 11 M1363400104 DRAIN HOSE 1 12 0605515198 HOSE BAND 2
13 V8159966 WATER SEPARATOR .................................. 1 .................. REPLACES P/N 0602042265
13A V8159975 FILTER, WATER SEPARATOR 14 0602022567 90 DEGREE ELBOW 2 15 0602022992 SWIVEL JOINT 2 16 0016910030 HEX. HEAD BOLT 2 17 0191302150 SUCTION HOSE 1 18 0191300600 SUCTION HOSE 1 19 0191302200 RETURN HOSE 1 20 0605515109 HOSE BAND 6
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 75
ENCLOSURE ASSY.
DCA-220SSVU— ENCLOSURE ASSY.
ADD THE FOLLOWING DIGITS AFTER THE PART NUMBER WHEN ORDERING ANY PAINTED PANEL TO INDICATE COLOR OF UNIT:
1-ORANGE 5-BLACK 2-WHITE 6-CATERPILLAR YELLOW 3-SPECTRUM GREY 7-CATO GOLD 4-SUNBELT GREEN 8-RED
THE SERIAL NUMBER MAY BE REQUIRED.
PAGE 76 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU— ENCLOSURE ASSY.
ENCLOSURE ASSY.
NO. PART NO. PART NAME QTY. REMARKS
1 M4413000002 BASE 1 1A M4493000004 ACOUSTIC SHEET 2 2 M1413400004 COVER 1 3 0016908020 HEX. HEAD BOLT 2 4 M4423000102 FRONT FRAME 1 4A M4493100103 ACOUSTIC SHEET 1 5 M4423000002 FRONT FRAME 1 5A M4493100103 ACOUSTIC SHEET 1 6 0016908020 HEX. HEAD BOLT 13 7 0016910030 HEX. HEAD BOLT 8 8 M4423200004 COVER, FRONT FRAME 1 8A M4493100004 ACOUSTIC SHEET 1 9 0016908020 HEX. HEAD BOLT 22 10 M4423200103 OVER COVER, FRONT FRAME 1 11 0016908020 HEX. HEAD BOLT 14 12 M4433000002 CENTER FRAME 1 13 0010114050 HEX. HEAD BOLT 4 13A 0030014000 HEX. NUT 4 13B 0040014000 SPRING WASHER 4 13C 0041214000 PLAIN WASHER 8 14 0010120050 HEX. HEAD BOLT 4 14A 0030020000 HEX. NUT 4 14B 0040020000 SPRING WASHER 4 14C 0041220000 PLAIN WASHER 8 15 M4443000002 REAR FRAME 1 15A M4493300104 ACOUSTIC SHEET 2 16 0016910030 HEX. HEAD BOLT 4 17 M4443300103 COVER, REAR FRAME 1 17A M4493300204 ACOUSTIC SHEET 1 18 M4443300003 DUCT 1 18A M4493300004 ACOUSTIC SHEET 1 19 0207008000 HEX. NUT 12 20 0016908020 HEX. HEAD BOLT 17 21 M4443200003 DOOR, REAR FRAME 1 22 M4443600004 WINDOW PLATE 1 23 0207306000 HEX. NUT 8 23A 0041206000 PLAIN WASHER 8 24 M9113000002 DOOR HANDLE 1
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 77
ENCLOSURE ASSY. (CONT.)
DCA-220SSVU— ENCLOSURE ASSY. (CONT.)
ADD THE FOLLOWING DIGITS AFTER THE PART NUMBER WHEN ORDERING ANY PAINTED PANEL TO INDICATE COLOR OF UNIT:
1-ORANGE 5-BLACK 2-WHITE 6-CATERPILLAR YELLOW 3-SPECTRUM GREY 7-CATO GOLD 4-SUNBELT GREEN 8-RED
THE SERIAL NUMBER MAY BE REQUIRED.
PAGE 78 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU— ENCLOSURE ASSY. (CONT.)
ENCLOSURE ASSY. (CONT.)
NO. PART NO. PART NAME QTY. REMARKS
25 0021806016 MACHINE SCREW 4 25A 0030006000 HEX. NUT 4 26 M9110100204 HINGE 2 26A M9116100004 WASHER 2 27 0016908020 HEX. HEAD BOLT 3 28 M9310000004 BLIND PLUG 2 29 M4463100002 ROOF PANEL 1 29A M4490600004 ACOUSTIC SHEET 1 30 M9310000103 BONNET CAP 1 31 M1483600204 CHAIN ASSEMBLY 2 32 M4463200002 ROOF PANEL 1
32A M4493500004 ACOUSTIC SHEET 1 33 0016908020 HEX. HEAD BOLT 40 34 M4453200002 SPLASHER PANEL 1 35 0016908065 HEX. HEAD BOLT 6 36 M4453000003 SIDE DOOR 1 36A M4493400004 ACOUSTIC SHEET 1 37 M4453000103 SIDE DOOR 1 37A M4493400104 ACOUSTIC SHEET 1 38 M4453000303 SIDE DOOR 1 38A M4493400304 ACOUSTIC SHEET 1 39 M4453000203 SIDE DOOR 1 39A M4493400204 ACOUSTIC SHEET 1 40 M4453300404 DUCT 2 40A M4493100204 ACOUSTIC SHEET 2 41 M4453300104 DUCT 1 41A M4493300704 ACOUSTIC SHEET 1 42 0207008000 HEX. NUT 19 43 M9113000002 DOOR HANDLE 4 44 M9113000102 DOOR HANDLE 3 45 0021806016 MACHINE SCREW 28 45A 0030006000 HEX. NUT 28 46 M4453700004 GUTTER 1 47 0016906016 HEX. HEAD BOLT 3 48 M9110100804 HINGE 6 48A M9116100004 WASHER 6 49 M9110100904 HINGE 5 49A M9116100004 WASHER 5 50 0019208020 HEX. HEAD BOLT 25 51 0601850097 STOPPER 9 52 0027208025 MACHINE SCREW 9 53 M9310000004 BLIND PLUG 11 54 M4483000002 SUPPORT LEG 1 55 0016910025 HEX. HEAD BOLT 5
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 79
RUBBER SEALS ASSY.
DCA-220SSVU— RUBBER SEALS ASSY.
PAGE 80 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU— RUBBER SEALS ASSY.
RUBBER SEALS ASSY.
NO. PART NO. PART NAME QTY. REMARKS
1 0229201300 SEAL RUBBER 4 2 0228901010 SEAL RUBBER 4 3 0228901200 SEAL RUBBER 4 4 0228901050 SEAL RUBBER 3 5 0228900600 SEAL RUBBER 2 6 0229200950 SEAL RUBBER 1 7 0228901230 SEAL RUBBER 2 8 0229201200 SEAL RUBBER 1 9 0228801070 SEAL RUBBER 2 10 0228800640 SEAL RUBBER 1 11 0228800680 SEAL RUBBER 1 12 0228100560 SEAL RUBBER 2 13 0228100370 SEAL RUBBER 2
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 81
NAMEPLATE AND DECALS ASSY.
DCA-220SSVU— NAMEPLATE AND DECALS ASSY.
PAGE 82 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
DCA-220SSVU— NAMEPLATE AND DECALS ASSY.
NAMEPLATE AND DECALS ASSY.
NO. PART NO. PART NAME QTY. REMARKS
1-1 M3552000103 DECAL; OPERATING PROCEDURES ........................ 1 ........... M35200010
1-2 M9520100304 DECAL; SAFETY INSTRUCTIONS ............................. 1 ........... M92010030
1-3 M9520100603 DECAL; CAUTION ....................................................... 2 ........... M92010060
CONTROL PANEL & BOX GROUP
2-1 M4550000012 DECAL; CONTROL PANEL .......................................... 1 ........... M45000001
2-2 M9520000104 PLATE; AMMETER CHANGE- OVER SWITCH........... 1 ........... M92000010
2-3 M9520000204 PLATE; VOLTMETER CHANGE- OVER SWITCH........ 1 ........... M92000020
2-4 M9520100004 DECAL; WARNING ELECTRIC SHOCK HAZARD ....... 2 ........... M92010000
2-5 M9520200104 DECAL; OVER CURRENT RELAY .............................. 1 ........... M92020010
2-6 M9520200303 DECAL; SETTING FOR OUTPUT VOLTAGE ............... 1 ........... M92020030
2-7 M9522000504 DECAL; CIRCUIT BREAKER ...................................... 1 ........... M92200050
ENGINE & RADIATOR GROUP
3-1 M9500000004 DECAL; OIL DRAIN PLUG .......................................... 1 ........... M90000000
3-2 M9500100004 DECAL; WATER ........................................................... 1 ........... M90010000
3-3 M9503000004 DECAL; WARNING MOVING PARTS ........................... 3 ........... M90300000
3-4 M9503000103 DECAL; WATER * OIL CHECK .................................... 1 ........... M90300010
3-5 M9503100004 DECAL; WARNING HOT COOLANT ............................ 1 ........... M90310000
3-6 M9510100004 DECAL; CAUTION HOT PARTS................................... 1 ........... M91010000
OUTPUT TERMINAL GROUP
4-1 M4550000103 DECAL; RECEPTACLE & CIRCUIT BREAKER........... 1 ........... M45000010
4-2 M9520000004 DECAL; GROUND........................................................ 1 ........... M92000000
4-3 M9520000504 DECAL; START CONTACT .......................................... 1 ........... M92000050
4-4 M9520000704 DECAL; 3- PHASE OUTPUT TERMINAL .................... 1 ........... M92000070
4-5 M9520100404 DECAL; DANGER HIGH VOLTAGE .............................. 1 ........... M92010040
4-6 M9520100503 DECAL; WARNING ...................................................... 1 ........... M92010050
BATTERY GROUP
5-1 M9500300004 DECAL; - ...................................................................... 1 ........... M90030000
5-2 M9500300104 DECAL; + ..................................................................... 1 ........... M90030010
5-3 M9510100403 DECAL; CAUTION ....................................................... 1 ........... M91010040
MUFFLER GROUP
6-1 M9503200004 DECAL; WARNING ENGINE EXHAUST ...................... 1 ........... M90320000
FUEL TANK GROUP
7-1 M9500500004 DECAL; DIESEL FUEL ................................................ 1 ........... M90050000
7-2 M9500500104 DECAL; FUEL DRAIN PLUG ....................................... 1 ........... M90050010
BONNET GROUP
8-1 M9510200002 DECAL; MQ ................................................................. 1 ........... M91020000
8-2 0600500090 EMBLEM 2
0021106016 MACHINE SCREW 4 8-3 M4560100003 STRIPE 1 8-4 M4560100103 STRIPE 1 8-5 M4560100204 STRIPE 2 8-6 M4560100303 STRIPE 1 8-7 M4560100404 STRIPE 2 8-8 M4560100503 STRIPE 1 8-9 M4560100603 STRIPE 1
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 83
Effective: October 1, 2002
TERMS AND CONDITIONS OF SALE — PARTS
PAYMENT TERMS
Terms of payment for parts are net 10 days.
FREIGHT POLICY
All parts orders will be shipped collect or prepaid with the charges added to the invoice. All shipments are F.O.B. point of origin. Multiquip’s responsibility ceases when a signed manifest has been obtained from the carrier, and any claim for shortage or damage must be settled between the consignee and the carrier.
MINIMUM ORDER
The minimum charge for orders from Multiquip is $15.00 net. Customers will be asked for instructions regarding handling of orders not meeting this requirement.
RETURNED GOODS POLICY
Return shipments will be accepted and credit will be allowed, subject to the following provi­sions:
1. A Returned Material Authorization must be approved by Multiquip prior to ship­ment.
2. To obtain a Return Material Authorization, a list must be provided to Multiquip Parts Sales that defines item numbers, quanti­ties, and descriptions of the items to be returned.
a. The par ts numbers and descriptions
must match the current parts price list.
b. The list must be typed or computer
generated.
c. The list must state the reason(s) for
the return.
d. The list must reference the sales
order(s) or invoice(s) under which the items were originally purchased.
e. The list must include the name and
phone number of the person request­ing the RMA.
3. A copy of the Return Material Authoriza­tion must accompany the return shipment.
4. Freight is at the sender’s expense. All parts must be returned freight prepaid to Multiquip’s designated receiving point.
5. Parts must be in new and resalable con-
6. The following items are not returnable:
7. The sender will be notified of any
8. Such material will be held for five
9. Credit on returned parts will be issued at
10. In cases where an item is accepted, for
11. Credit issued will be applied to future
PRICING AND REBATES
Prices are subject to change without prior notice. Price changes are effective on a spe­cific date and all orders received on or after that date will be billed at the revised price. Rebates
for price declines and added charges for price dition, in the original Multiquip package (if any), and with Multiquip part numbers clearly marked.
a. Obsolete parts. (If an item is in the
price book and shows as being replaced by another item, it is obsolete.)
b. Any parts with a limited shelf life
(such as gaskets, seals, “O” rings, and other rubber par ts) that were pur­chased more than six months prior to the return date.
c. Any line item with an extended dealer
net price of less than $5.00.
d. Special order items.
e. Electrical components.
f. Paint, chemicals, and lubricants. g. Decals and paper products.
h. Items purchased in kits.
material received that is not acceptable.
working days from notification, pending instructions. If a reply is not received within five days, the material will be re­turned to the sender at his expense.
dealer net price at time of the original purchase, less a 15% restocking charge.
which the original purchase document can not be determined, the price will be based on the list price that was effective twelve months prior to the RMA date.
purchases only.
increases will not be made for stock on hand at
the time of any price change.
Multiquip reserves the right to quote and sell
direct to Government agencies, and to Original
Equipment Manufacturer accounts who use
our products as integral parts of their own
products.
SPECIAL EXPEDITING SERVICE
A $35.00 surcharge will be added to the invoice
for special handling including bus shipments,
insured parcel post or in cases where Multiquip
must personally deliver the parts to the carrier.
LIMITATIONS OF SELLER’S LIABILITY
Multiquip shall not be liable here under for
damages in excess of the purchase price of the
item with respect to which damages are claimed,
and in no event shall Multiquip be liable for loss
of profit or good will or for any other special,
consequential or incidental damages.
LIMITATION OF WARRANTIES
No warranties, express or implied, are made in
connection with the sale of parts or trade
accessories nor as to any engine not manufac-
tured by Multiquip. Such warranties made in
connection with the sale of new, complete units
are made exclusively by a statement of war-
ranty packaged with such units, and Multiquip
neither assumes not authorizes any person to
assume for it any other obligation or liability
whatever in connection with the sale of its
products. Apart from such written statement of
warranty, there are no warranties, express,
implied or statutory, which extend beyond the
description of the products on the face hereof.
PAGE 84 — DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06)
NOTE PAGE
1
DCA-220SSVU (50 Hz) — OPERATION AND PARTS MANUAL — REV. #0 (04/18/06) — PAGE 85
PARTS AND OPERATION MANUAL
OPERATION AND PARTS MANUAL
HERE'S HOW TO GET HELP
PLEASE HAVE THE MODEL AND SERIAL
NUMBER
MQ POWER CORPORATE OFFICE
18910 Wilmington Ave. 800-421-1244 Carson, CA 90746 Email: mqpower@multiquip.com Internet: www.mqpower.com
PARTS DEPARTMENT
800-427-1244 310-537-3700
SERVICE DEPARTMENT
800-835-2551 310-537-3700
TECHNICAL ASSISTANCE
800-835-2551
WARRANTY DEPARTMENT
800-835-2551, 310-537-3700,
ON-HAND
EXT.
279
EXT.
279
WHEN CALLING
FAX:
310-632-2656
FAX:
800-672-7877
FAX:
310-637-3284
FAX:
310-638-8046
FAX:
310-638-8046
FAX:
310-638-8046
Your Local Dealer is:
Manufactured for Multiquip Inc.
by
DENYO CO., LTD, JAPAN
MQ POWER
A Division of Multiquip Inc.
POST OFFICE BOX 6254 CARSON, CA 90749 310-537-3700 • 800-421-1244 FAX: 310-632-2656 E-mail: mqpower@multiquip.com Internet: www.mqpower.com
Loading...