Multiplex WBK10 Installation Manual

Subject: Model WBK10 Water Booster Pump
!
Caution
Important

P.N. 00215639 (120 VAC, 60 HZ)

020002662
9/15
Instructions
Caution: To Avoid Serious Injury
Read the following warnings before beginning an installation. Failure to do so may result in possible death or serious injury.
DO Adhere to all National and Local Plumbing and Electrical Safety Codes.
DO Turn “off” incoming electrical service switches when servicing, installing, or repairing equipment.
wrench to ensure a quality seal.
DO Inspect pressure on Regulators before starting up equipment.
DO Protect eyes when working around refrigerants.
DO Use caution when handling metal surface edges of all equipment.
DO Handle CO2 cylinders and gauges with care. Secure cylinders properly against abrasion.
DO Store CO2 cylinder(s) in well ventilated areas.
DO NOT Throw or drop a CO2 cylinder. Secure the cylinder(s) in an upright position with a chain.
DO NOT Connect the CO2 cylinder(s) directly to the product container. Doing so will result in an explosion
causing possible death or injury. Best to connect the CO2 cylinder(s) to a regulator(s).
DO NOT Store CO2 cylinders in temperature above 125°F (51.7°C) near furnaces, radiator or sources of heat.
DO NOT Release CO2 gas from old cylinder.
DO NOT Touch Refrigeration lines inside units, some may exceed temperatures of 200°F (93.3°C).
NOTE: Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed and
maintained in accordance with Federal, State, and Local codes.
Manitowoc Foodservice, 2110 S. 26th St., P.O. Box 1720, Manitowoc, WI 54221-1720, Tel: 920-682-0161, www.manitowocfsg.com
Model WBK10 Water Booster Pump 020002662 9/15
!
Warning
!
Warning
FIG 1
Disconnect and lock out all electrical power sources before performing service or maintenance on this machine - - except when electrical tests are being performed by qualified service personnel.

Introduction

The following instructions cover the installation of a 120 VAC, 60 Hz (domestic). An appropriate 3-Wire power receptacle must be located within 6 ft (1.8 m) of the Booster Kits.
NOTE: Do not plug in Booster Pump Module at this time.

Grounding instructions

The Multiplex Model WBK10 Water Booster Pump should be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electrical current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
RISK OF ELECTRIC SHOCK: This kit is supplied with a ground conductor and grounding-type attachment plug (domestic only). To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.
Check with a qualified electrician or serviceman if the grounding instructions are not completely understood, or if in doubt as to whether the product is properly grounded. Do not modify the plug provided; if it will not fit the outlet, have the proper outlet installed by a qualified electrician.
This product is for use with a 120 VAC, 60 Hz (Domestic). CSA requires that a switch be provided to disconnect both outlets from the power supply (refer to figure 1).
Do not use an extension cord or an adapter plug with this equipment.

How to install the water booster pump to a wall

1. Locate the six (6) 5/16” lag screws and the mounting bracket.
2. Mount the J-channel to the wall using three (3) screws (provided).
NOTE: Screws must be located in a stud. If mounting to concrete wall, proper hardware (not provided) must be used.
3. Mount the booster Panel on the wall by raising the top of the panel over the J-channel. Place the panel against wall and slide the panel down until is catches on the J-channel. Mount the bottom of the panel to the wall using the remaining two (2) screws (refer to figure 2).
Manitowoc Foodservice Group, 2110 S. 26th St., P.O. Box 1720, Manitowoc, WI 54221-1720, Tel: 920-682-0161, www.manitowocfsg.com