Vertical Discharge
Remote Condenser
For Multiplex Chillers
Remote, air-cooled
condenser system conserves
energy and improves
beverage cooling efficiency.
Multiplex remote condenser
systems effectively dissipate
heat at a convenient location,
indoors or outdoors, away
from the chiller. This
maximizes beverage cooling
capability and minimizes
air conditioning loads
by lowering the ambient
air temperature at the chiller.
TS-0895
Remote Condenser
• One size for all remote
condenser Multiplex
chillers.
• Vertical discharge remote
condenser is available for
Multiplex Model 50 and
Model 44. Refer to
specification sheet for
equipment dimensions,
production capacities and
electrical requirements.
• Condenser operation range
from -20°F (-29°C) to 120°F
(49°C). Can be installed
with up to 15" (38.1 cm) of
bottom clearance.
ISO 9001: 2000
Quality System
Certified
High Volume Dispensing Solutions
Remote Recirculation Soda Systems • Long Draw Beer Systems • Pre-Chillers
Multiplex Remote Condenser
O
ptional
34.00"
(86.36 cm)
or
30.00"
(
76.20 cm)
2
4
.
5
0
" (
6
2
.
2
3
c
m
)
2
8
.
0
0
" (
7
1
.
1
2
c
m
)
2
9
.
1
6
" (
7
4
.
0
6
c
m
)
Electrical
Entrance
Discharge
Refrig.
Line
Liquid
Refrig.
Line
A
A
B
B
C
C
D
E
G
F
D
6.00" (15.24 cm)
3.50" (8.89 cm)
3.88" (9.85 cm)
12.13" (30.81 cm)
E
F
G
1.50" (3.81 cm)
6.50" 16.51 cm)
Optional
20.00" (50.80 cm)
16.00" (40.64 cm)
12.00" (30.48 cm)
I
C
E
M
A
K
E
R
S
A
U
T
O
M
A
T
I
C
C
O
M
M
E
R
C
I
A
L
M
A
N
U
F
A
C
T
U
R
E
R
C
E
R
T
I
F
I
E
D
T
O
A
R
I
A
S
C
O
M
P
L
Y
I
N
G
W
I
T
H
®
Installation Information and Dimensions
Maximum Location Distance—combined vertical and horizontal distances from chiller to
condenser must comply with guidelines.
Maximum Line Length: 100' (30 m)*
Maximum Vertical Rise: 35' (10.5 m) above chiller.
Maximum Vertical Drop: 15' (4.5 m) below chiller.
To calculate other acceptable horizontal and vertical combinations, refer to remote condenser
nstallation instructions.
i
Electric
Electrical power to the remote condenser is intended to be supplied from the Multiplex chiller.
Condenser Model Electrical Service* Amperage lbs. kgs.
TS-0895 44 or 50 208-230/60/50/1 1.3 85 39
*230/50/1 available. Consult factory. HACR circuit breakers can be used in place of fuses.
Weight
Standard Interconnecting Refrigerant Lines
Line Length Weight
Model ft. cm. lbs. kgs.
RT-20-R-404A 20 600 11 5
RT-35-R-404A 35 1,050 17 8
RT-50-R-404A 50 1,500 24 11
TS-0895
Remote
Condenser
3961A ©2007 Multiplex 11/07 Continuing product improvement may necessitate change of specifications without notice.
MANITOWOC BEVERAGE
EQUIPMENT, INC.
2100 Future Drive
Visit us online at www.manitowocbeverage.com
Ph: 800-367-4233 • Fax: 812-246-7024
Sellersburg, IN 47172, USA