Multiplex RT-20-R-404A Installation Manual

Vertical Discharge
Remote Condenser
For Multiplex Chillers
Remote, air-cooled condenser system conserves energy and improves beverage cooling efficiency.
Multiplex remote condenser systems effectively dissipate heat at a convenient location, indoors or outdoors, away from the chiller. This maximizes beverage cooling capability and minimizes air conditioning loads by lowering the ambient air temperature at the chiller.
TS-0895 Remote Condenser
One size for all remote
condenser Multiplex chillers.
Vertical discharge remote
condenser is available for Multiplex Model 50 and Model 44. Refer to specification sheet for equipment dimensions, production capacities and electrical requirements.
Condenser operation range
from -20°F (-29°C) to 120°F (49°C). Can be installed with up to 15" (38.1 cm) of bottom clearance.
ISO 9001: 2000 Quality System Certified
High Volume Dispensing Solutions
Remote Recirculation Soda Systems • Long Draw Beer Systems • Pre-Chillers
Multiplex Remote Condenser
O
ptional
34.00"
(86.36 cm)
or
30.00"
(
76.20 cm)
2
4
.
5
0
" (
6
2
.
2
3
c
m
)
2
8
.
0
0
" (
7
1
.
1
2
c
m
)
2
9
.
1
6
" (
7
4
.
0
6
c
m
)
Electrical Entrance
Discharge Refrig. Line
Liquid Refrig. Line
A
A B
B
C
C
D
E
G
F
D
6.00" (15.24 cm)
3.50" (8.89 cm)
3.88" (9.85 cm)
12.13" (30.81 cm)
E F
G
1.50" (3.81 cm)
6.50" 16.51 cm) Optional
20.00" (50.80 cm)
16.00" (40.64 cm)
12.00" (30.48 cm)
I
C
E
M
A
K
E
R
S
A
U
T
O
M
A
T
I
C
C
O
M M
E
R
C
I
A
L
M
A
N
U
F
A
C
T
U
R
E
R
C
E
R
T
I
F
I
E
D
T
O
A
R
I
A
S
C
O
M
P
L
Y I
N
G
W
I
T
H
®
Installation Information and Dimensions
Maximum Location Distance—combined vertical and horizontal distances from chiller to condenser must comply with guidelines.
Maximum Line Length: 100' (30 m)* Maximum Vertical Rise: 35' (10.5 m) above chiller. Maximum Vertical Drop: 15' (4.5 m) below chiller.
To calculate other acceptable horizontal and vertical combinations, refer to remote condenser
nstallation instructions.
i
Electric
Electrical power to the remote condenser is intended to be supplied from the Multiplex chiller.
Condenser Model Electrical Service* Amperage lbs. kgs.
TS-0895 44 or 50 208-230/60/50/1 1.3 85 39
*230/50/1 available. Consult factory. HACR circuit breakers can be used in place of fuses.
Weight
Standard Interconnecting Refrigerant Lines
Line Length Weight
Model ft. cm. lbs. kgs. RT-20-R-404A 20 600 11 5 RT-35-R-404A 35 1,050 17 8 RT-50-R-404A 50 1,500 24 11