Multiplex Channel Plus 5415 Installation Manual

Warranty
600-122
Multiplex Technology, Inc. warrants this product to be free from defects in materials and workmanship for a period of one year from the date of purchase or MTI will repair, or at its option, replace the defective product. To obtain warranty service, call MTI for a return material authorization (RMA) number and return the product prepaid to Multiplex Technology, Inc., 3001 Enterprise Street, Brea, CA 92821, Attention: Customer Service. Please put the RMA number on the outside of the carton.
Any implied warranty arising from the sale of the product including implied warranties of merchantability and fitness for purpose are limited to the warranty stated above. MTI shall not be responsible for losses or damages or expenses, whether direct, consequential or incidental arising from the use of or the inability to use this product. Some states do not allow limitations on how long the implied warranty lasts or the exclusion or limitation or incidental or consequential damages, so the above limitations and exclusions may not apply to you. This warranty gives you specific legal rights, and you may have other rights which may vary from state to state.
Multiplex Technology, Inc., Brea, CA 92821
Multiplex Technology, Inc., Brea, CA 92821
This device complies with the FCC's Part 15 Rules for TV interface devices. Any change or modification to this device without the permission of Multiplex Technology, Inc. may void the user's authority to operate this equipment.
PERFORMANCE MULTI-ROOM VIDEO
Model 5415
Frequency-Agile Video Modulator
Modulator
Installation Manual
3001 Enterprise Street, Brea, CA 92821-6213, U.S.A.
714-996-4100 * 800-999-5225 * FAX 714-996-4900 * www.channelplus.com
multiplex
technology, inc.
®
Channel
R
model 5415 digital modulator
model 5415 digital modulator
pll frequency control
pll frequency control
program
pwr
Controls and Connections
The ChannelPlus 5400 Series are digitally-tuned video modulators that convert any baseband video and audio signal to a user-selected UHF, or Ultraband CATV. An internal quartz crystal reference oscillator and PLL circuitry ensure drift-free performance. The user selects the output frequency (channel) using the "program" button to enter the number of the desired channel. Any TV connected to the output via coax canreceive the signals, whenthe TV is tuned tothe proper channel.
Model 5415 - Single channel agile modulator
RF output
Program button to enter the chann el number
Video input
Video input termination jumper (When connecting video to a local monitor, remove this jumper for hi-Z)
Power supply 15VDC 300mA
Audio inputs: Right and left are combined for monaural.
model 5415 digital modulator
model 5415 digital modulator
pll frequency control
pll frequency control
program
program
pwr
VIDEO
OUTPUT
L
R
AUDIO
AUDIO
POWER 15VDC 300mA
POWER 15VDC 300mA
LOOP
2
Cable HRC andIRC considerations
Most cable services use IRC frequency assignments. This is the default for the ChannelPlus modulators. However, if the cable service uses HRC or the TV appears to search for the "house channels," the modulator can be reprogrammed to use HRC assignments by entering the number “ 98”. Set to IRC by entering a “99”. Both of these settings are only used for settingHRC/IRC.
5400 series
Changing modulation standards
7
Specifications: typical @ 25 C ± 5 C
OO
5415 Modulator
RF output
Power supply
Physical
performance
Video
Inputs
65-125
(excluding 95-99)
14-64
channel ranges
model number
signal/noise 55 dB
-60 dBC
3 watts
+25 dBmV (90dBuV)
105-125 VAC
-45dBC @ 12MHz
300mA
15 VDC
differential phase
<4º
differential gain
L & R inputs combined for monaural
4%
audio
1 V rms @ 47k
video
UHF
350-076
CATVstandard
1Vp-p@75
output level
input power
IM distortion
power consumption
alternate channel
output voltage
output current
weight
depth 14.1 cm (5.5 in)
width 11.7 cm (4.6 in)
height 2.5 cm (1.0 in)
0lbs 11 oz (1.19kg)
Mounting hole template
To hang with connectors on the side To hang with connectors on the bottom or top