Multiplex 44M Installation Manual

Subject: 44M & 50M Energy Saver Kit
FIG 2
FIG 1
FIG 3
Installation
1. Disconnect power to chiller and turn off water and CO
NOTE: The Model 50M kit has two circulation motors / pumps.
3. Bleed water from lines and use clamps to shut off water from both circulation and carbonation lines. Failure to do so may cause electrical shock or injury.
4. Remove 2 mounting screws on ERC and let the board hang by the wires. (Fi g ure 2 ) Do not discard the mounting screws as they will be used again in step 4.
5. Installation of new ERC board:
A. Install new ERC board provided with mounting screws from step 3. B. Move connections from existing ERC board to the new ERC board, one at a
time, to get correct. (Figure 3)
6. Install front panel with screws that were removed in step 2.
7. Energy saving mode will enable once circulators are turned on, and no carbonation cycles for 30 minutes.
A. Energy savings mode is indicated by a "oXXX" (zero in left digit) B. Energy savings mode will turn agitator and circulator off for 10 minutes, then
turn on till circulation temperature is below target temperature. C. Temperatures above 38°F will not enable energy savings mode. D. First carbonation cycle will disable energy savings mode.
NOTE: This new ERC control board will change circulator LEDs to flash when ON and remain lit when controlled OFF by energy saving mode.
020003428
1/11
Instructions
2 supply.
Parts Included in Kit 020003210 for 44M
Qty Description Part Number
1 Kit Retro Circulation Pump 020003211 1 Kit Retro Agitator Motor 020003208 1 ERC Control Board 020001985 1 Energy Saver Kit Instructions 020003428
Qty Description Part Number
2 Kit Retro Circulation Pump 020003211 1 Kit Retro Agitator Motor 020003208 1 ERC Control Board 020001985 1 Energy Saver Kit Instructions 020003428
Manitowoc Beverage Systems Sellersburg, 2100 Future Drive, Sellersburg, IN 47172, Tel: 812-246-7000, www.manitowocbeverage.com
Parts Included in Kit 020003209 for 50M