Icecore® Remote Refrigeration Units
44G • 50G • 44HC
NEW,
ENERGY-SAVING
FEATURES!
Icecore® Remote Refrigeration Units
44G • 50G • 44HC
The Icecore® provides the most
consistent, high-quality beverages in
the industry.
2100 Future Drive
Sellersburg, IN 47172 USA
Tel: 812.246.7000
Fax: 812.246.7024
Standard Features
• Uses up to 30% less energy than previous models.
• New, magnetic-drive circulation pump improves
reliability by eliminating pump seal.
• Patent-pending control software monitors demand and
reduces low-demand energy consumption
• All water used for cooling drinks is recycled with virtually
no waste water; reduces water and sewage expenses.
• Durable, easy-to-clean stainless steel cabinet.
ISO 9001:2000
Quality System Certified
www.manitowocbeverage.com/us
Icecore® Remote Refrigeration Units
44G • 50G • 44HC
Specications
Icecore 44G Icecore 50G Icecore 44 HC
Standard Features Internal cold carbonation, magnetic-drive circulation pump, stainless steel cabinet
Volts 208-230 208-230 208-230 340-440 220
Hz 60 50 60 50 50
Phase 1 1 3 3 1
Electrical
Minimum Circuit Amps 21 20 26 15 NA*
Maximum Breaker Size 30 30 30 20 NA*
Compressor 1.0 hp / 1.6 kW 2.2 hp / 2.2 kW 2/3 hp / 1.242 kW
Ice Bank Size (Nominal) 140 lbs / 63.3 kgs 200 lbs / 90.5 kgs 140 lbs / 63.3 kgs
Evaporator Rating
(20°F / -6.5°C)
9,700 BTUH / 2,444 kcal/hr 14,900 BTUH / 5,143 kcal/hr
Heat Rejection (Maximum) 13,576 BTUH / 3,421 kcal/hr 20,408 BTUH / 5,143 kcal/hr
16,400 BTUH /
4,132 kcal/hr
16,378 BTUH /
4,270 kcal/hr
Coolant R-404A R-290**
Condenser Types Air-cooled, water-cooled or remote Air-cooled
Drink Capacity per hour @ 75°F
Peak (max for 2 hr period) /
(24°C)
500 / 288 600 / 420 500/288
Sustained
Maximum Conduit Length 250 ft / 76 m 350 ft / 107 m 250 ft / 76 m
Syrup Coils (Standard/Maximum) 8 / 12 8 / 14 8 / 12
Shipping Weight (Approximate) 340 lbs / 154 kgs 395 lbs / 179 kgs 340 lbs / 154 kgs
Options Legs, stand, additional syrup coils, casters
* This model is not hard wired
** Check your local agencies for R290 Hydro-Carbon refrigerant acceptance
Junction Box
Wall
A B
Side View Front View Top View
Dimensions
Unit Width Depth Height
Model
44G
Model
50G
Model
44HC
2100 Future Drive
Sellersburg, IN 47172 USA
Ceiling
Conduit to
Incoming
Water Line
Incoming CO
Supply Line
Incoming Syrup
Supply Lines
Drain Connection
2
Dispensing Towers
Wall
2 Regulator Panel
CO
(Optional)
Leg
Height
18" (45.7 cm)
minimum
Drain Connection
Floor drain should
be located within
Drain
Connection A
Wall
Drain
Connection B
39.75" 24.75" 30.25" 6" 12" 6"
101 cm 62.9 cm 76.83 cm 15.2 cm 30.5 cm 15.2 cm
42.25" 28.25" 32.00" 6" 14" 8.5"
107.3 cm 71.8 cm 81.3 cm 15.2 cm 35.6 cm 21.6 cm
39.75" 24.75" 30.25" 6" 12" 6"
101 cm 62.9 cm 76.83 cm 15.2 cm 30.5 cm 15.2 cm
Tel: 812.246.7000
Fax: 812.246.7024
www.manitowocbeverage.com/us
12"
(30.5 cm)
minimum
Wall
3.875" (9.8 cm)
Diameter
6" (15.2 cm)
Diameter Chase minimum
Wall
6" (15.2 cm) minimum
Electrical
Junction Box
Depth
Height
Leg Height
11"
(28 cm)
Air Flow
18"
(45.7 cm)
minimum
Control
Switches
Width
Wall
4859C ©2015 Multiplex 11/15 Continuing product improvement may necessitate change of specifications without notice.