Multiplex 42M User Manual

Soda Factory™ Remote Refrigeration Units
2803•11M• 42M
2803•11M• 42M
The Soda Factory™ provides the most consistent, high-quality beverages in the industry.
2100 Future Drive
Sellersburg, IN 47172 USA
Tel: 812.246.7000
Fax: 812.246.7024
Standard Features
• Remote recirculation system keeps carbonated water and
syrup chilled from location of the refrigeration unit to
beverage dispensers.
• All water used for cooling drinks is recycled with virtually
no waste water; reduces water and sewage expenses.
• Reduced ice consumption compared to
coldplate systems.
• Durable, easy to clean stainless steel cabinet.
• Reduced counter space need compared to
coldplate systems.
• Environmentally friendly R-404A refrigerant.
ISO 9001:2000 Quality System Certi ed
www.manitowocbeverage.com/us
2803•11M• 42M
Speci cations
Standard Features Internal cold carbonation, recirculation pump, stainless steel cabinet
Electrical Requirements
Compressor 1/3 hp / .25 kw 1/2 hp / .37 kw 1.0 hp / .75 kw
Shipping Weights (Approx.)
Ice Bank Size (Normal) 28 lbs. / 12.7 kgs 60 lbs. / 27.22 kgs 140 lbs. / 63.50 kgs
Condenser (Self-contained)
Conduit (Maximum Run) 40 ft / 12.19m 100 ft / 30.48m 250 ft / 76.20m
Evaporator Rating
(20°F / -6.5°C)
Heat Rejection
(Maximum)
Carbonation System Single tank, single 100 gph pump
Syrup Coils
(Standard/Maximum)
Drink Capacity/hour* 108/60 228/150 500/288
Options
*Peak (for 2 hrs.) / sustained (12 oz. dispensed at or below 40°F / 75°F Ambient)
120V/60Hz/1/20.3
230V/50Hz/1/9.0
130 lbs. / 59 kgs 230 lbs. / 104 kgs 340 lbs. / 154 kgs
Wall mount shelf, legs, stand, condenser  lter and on the model 11 ad-
Model 2803 Model 11M Model 42M (Obsolete)
120V/60Hz/1/21.5 230V/50Hz/1/10.7
208-230/V/60/1/20.6
208/230V/50/1/22.0
Air Cooled Air Cooled Air or Water Cooled, or Remote
2,500 BTUH
630 kcal/hr
4,500 BTUH
1,134 kcal/hr
5,150 BTUH
1,298 kcal/hr
8,638 BTUH
2,177 kcal/hr
9,700 BTUH
2,444 kcal/hr
13,576 BTUH 3,421 kcal/hr
6/6 6/8 8/12
Legs, stand, additional syrup coils,
ditional syrup coils and casters
casters, and condenser  lter
2
Conduit to Dispensing Towers
Wall
Junction Box
Incoming
Wall
A B
Side View Front View Top View
Water Line
Incoming CO Supply Line
Incoming Syrup Supply Lines
Drain Connection
Dimensions
Unit Width Depth Height Leg Height
Model 2803
Model 11M
Model 42M
2100 Future Drive
Sellersburg, IN 47172 USA
27.75" 16.25" 18.50" 4" 5.5" 8"
70.5 cm 41.3 cm 46.9 cm 10.1 cm 14 cm 20.3 cm
36.25" 19.50" 21.50" 6" 9" 5"
92.07 cm 49.5 cm 54.6 cm 15.2 cm 22.9 cm 12.7 cm
39.75" 24.75" 30.25" 6" 12" 6"
101 cm 62.9 cm 76.8 cm 15.2 cm 30.5 cm 15.2 cm
Tel: 812.246.7000
Fax: 812.246.7024
www.manitowocbeverage.com/us
CO
2 Regulator Panel
(Optional)
Ceiling
Drain Connection Floor drain should be located within 6 ft. (183 cm) of unit
18" (45.7 cm)
minimum
Wall
Drain
Connection A
12" (30.5 cm) minimum
Wall
3.875" (9.8 cm) Diameter
6" (15.2 cm) Diameter Chase minimum
Drain
Connection B
Wall
6" (15.2 cm) minimum
Electrical Junction Box
Height
Leg Height
11"
(28 cm)
Air Flow
(45.7 cm) minimum
Control
Switches
Depth
18"
Wall
Width
2895G ©2012 Multiplex 5/12 Continuing product improvement may necessitate change of specifications without notice.