Multiplex 174BD Installation Manual

Instructions
Subject: Model 174BD Wall-mounted Faucet Plate
P.N. 00917423
EI917423
8/09
INTRODUCTION
Installation materials include #10 screws for wood panel or metal wall. For plaster board or masonry wall, use appropriate mollybolts or inserts (n ot provided).
INSTALLING THE WALL MOUNTED FAUCET PLATE
Installation materials include #10 screws for wood panel or metal wall. For plaster board or masonry wall, use appropriate mollybolts or inserts (n ot provided).
1. Position the Faucet Plate against wall in the desired location and mark holes for faucet shanks and mou nting screws.
2. Drill 1/ 8" X 3/ 4" deep pilot holes for Faucet Plate mounting screws.
3. Drill 1" through holes for faucet shanks.
4. Attach the Faucet Plate to the wall with mounting screws.
5. Install the faucet shanks and secure with flange nuts.
6. Attach the faucets and drain hose.
Manitowoc Foodservice Sellersburg, 2100 Future Drive, Sellersburg, IN 47172, Tel: 812-246-7000, www.manitowocbeverage.com
Model 174BD Wall-mounted Faucet Plate EI917423
!
Caution
!
Warning
To Avoid Serious Injury Read the following warnings before beginning an installation. Falure to do so may result in possible death or serious injury.
DO Adhere to all National and Local Plumbing and Electrical Safety Codes. DO Turn “Off” incoming electrical service switches when servicing, installing, or repairing equipment. DO Check that all flare fittings on the carbonation tank(s) are tight. This check should be performed with a
wrench to ensure a quality seal. DO Inspect pressure on Regulators before starting up equipment. DO Protect eyes when working around refrigerants. DO Use caution when handling metal surface edges of all equipment. DO Handle C0 DO Store C0
2 cylinders and gauges with care. Secure cylinders properly against abrasion.
2 cylinder(s) in well ventilated areas.
DO NOT Throw or drop a C0 DO NOT Connect the C0
possible death or injury . Best to connect th e C0 DO NOT Store C0 DO NOT Release C0
2 cylinders in temperature above 125˚ F (51. 7˚ C) near furnaces, radiator or sources of heat.
2 gas from old cylinder.
DO NOT Touch Refrigeration lines inside units, some may exceed temperatures of 200
2 cylinder. Secure the cylinder(s) in an upright position with a chain.
2 cylinder(s) directly to the product container . Doing so will result in an explosion causing
2 cylinder(s) to a regulator(s).
˚ F (93.3˚ C).
NOTE: Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed and maintained in accordance with Federal, State, and Local codes.
DANGER OF ELECTRICAL SHOCK - Disconnect and lock out all electrical power sources before performing service or maintenance on this machine -- except when electrical tests are being performed by qualified service personnel.
Manitowoc Foodservice Sellersburg, 2100 Future Drive, Sellersburg, IN 47172, Tel: 812-246-7000, www.manitowocbeverage.com