Instructions
Subject: Model 146 T ower 4” Riser Kit
EI216368
8/09
TOWER LOCATION
Tower Location for Self Serve
American Disabilities Act (ADA) rules apply. Maximum distance set back from outside edge of tray rail for a 34"
counter is 12" (30.5 cm) and a 36" (91.4 cm) counter is 10" (25.4 cm)
1. Determine the location where the dispensing tower will be installed.
2. Locate the mounting template provided with the tower installation kit.
3. Using the mounting template as a guide, punch out the required holes in the counter top.
RISER MOUNTING INSTRUCTIONS
1. Using template supplied, drill mounting holes in countertop.
2. Mount riser to countertop through 3/8 diameter holes in riser with appropriate fasteners. Apply 1/4" bead of RTV
under base flange.
3. Route the rubber hose from the drai n pan to the drai n.
4. Locate the barb-stem splicers and tab-clamps in the tee kit. Attach spl icers to condu it per instructions.
5. Route the beverage conduit up through riser to the tower. If the lines of the conduit are different length s, always
connect the shortest line first. Use two (2) tabclamps per connection.
Manitowoc Foodservice Sellersburg, 2100 Future Drive, Sellersburg, IN 47172, Tel: 812-246-7000, www.manitowocbeverage.com
Model 146 Tower 4” Riser Kit EI216368
.
To Avoid Serious Injury Read the following warnings before
beginning an installation. Falure to do so may result in possible
death or serious injury.
DO Adhere to all National and Local Plumbing and Electrical Safety Codes.
DO Turn “Off” incoming electrical service switches when servicing, installing, or repairing equipment.
DO Check that all flare fittings on the carbonation tank(s) are tight. This check should be performed with a
wrench to ensure a quality seal.
DO Inspect pressure on Regulators before starting up equipment.
DO Protect eyes when working around refrigerants.
DO Use caution when handling metal surface edges of all equipment.
DO Handle C0
DO Store C0
2 cylinders and gauges with care. Secure cylinders properly against abrasion.
2 cylinder(s) in well ventilated areas.
DO NOT Throw or drop a C0
DO NOT Connect the C0
possible death or injury . Best to connect th e C0
DO NOT Store C0
DO NOT Release C0
2 cylinders in temperature above 125˚ F (51. 7˚ C) near furnaces, radiator or sources of heat.
2 gas from old cylinder.
DO NOT Touch Refrigeration lines inside units, some may exceed temperatures of 200
2 cylinder. Secure the cylinder(s) in an upright position with a chain.
2 cylinder(s) directly to the product container . Doing so will result in an explosion causing
2 cylinder(s) to a regulator(s).
˚ F (93.3˚ C).
NOTE: Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed and
maintained in accordance with Federal, State, and Local codes.
DANGER OF ELECTRICAL SHOCK - Disconnect and lock out all
electrical power sources before performing service or maintenance on
this machine -- except when electrical tests are being performed by
qualified service personnel.
Manitowoc Foodservice Sellersburg, 2100 Future Drive, Sellersburg, IN 47172, Tel: 812-246-7000, www.manitowocbeverage.com