Multiplex 00214969, 00212135, 00217555, 00212145, 00214971 Instruction Sheet

...
MULTIPLEX
2100 FUTURE, SELLERSBURG, IN 47172
WWW.MANITOWOCBEVERAGE.COM/US
800-367-4233
Instruction Sheet
Read the following warnings before beginning an installation. Failure to do so may result in possible death or serious injury.
Warning
n
To Avoid Serious Injury
DO Adhere to all National and Local Plumbing and
Electrical Safety Codes.
DO Turn “off” incoming electrical service switches when servicing, installing, or repairing equipment.
DO Check that all flare fittings on the carbonation tank(s) are tight. This check should be performed with a wrench to ensure a quality seal.
DO Inspect pressure on regulators before starting up equipment.
DO Protect eyes when working around refrigerants.
DO Use caution when handling metal surface edges of
all equipment.
DO Handle CO2 cylinders and gauges with care. Secure cylinders properly against abrasion.
DO Store CO2 cylinder(s) in well ventilated areas.
DO NOT Throw or drop a CO2 cylinder. Secure the
cylinder(s) in an upright position with a chain.
DO NOT Connect the CO2 cylinder(s) directly to the product container. Doing so will result in an explosion causing possible death or injury. It is best to connect the CO2 cylinder(s) to a regulator(s).
DO NOT Store CO2 cylinders in temperature above 125°F (51.7°C) near furnaces, radiator or sources of heat.
DO NOT Release CO2 gas from old cylinder.
DO NOT Touch refrigeration lines inside units. Some
may exceed temperatures of 200°F (93.3°C).
Subject: Installations Instructions
Air Compressor Kits
Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed and maintained in accordance with Federal, State, and Local codes.
Warning
n
Danger of Electric Shock
Disconnect and lock out all electrical power sources before performing service or maintenance on this machine — except when electrical tests are being performed by qualified service personnel.
1 of 9 Part Number 020006402 12/2014
Air Compressor Kits
Air Compressor Kit with Change-over Valve and Dump Valve — P.N. 00212135 (120 VAC), P.N. 00214969 (120 VAC), P.N. 00217555 (230 VAC)
These instructions cover the installation and initial start-up of the Multiplex Air Compressor Kit. An appropriate 3-wire, 15 amp power receptacle must be provided within 5 ft (152.4 cm) of the left end of the refrigeration unit. This kit is for use with either the Model 44 or Model 50 Fountain Refrigeration Units and any of the Beermaster Units. Refer to appropriate section for instructions.
GROUNDING INSTRUCTIONS
This product should be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
DANGER
Improper installation of the grounding plug can result in a risk of electric shock. If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to a flat blade terminal. The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire.
Check with a qualified electrician or serviceman if the grounding instructions are not completely understood, or if in doubt as to whether the product is properly grounded. Do not modify the plug provided; if it will not fit the outlet, have the proper outlet installed by a qualified electrician. Do not use an extension cord or an adapter plug with this equipment.
FOUNTAIN SYSTEMS APPLICATIONS
Air Compressor
Mounting Channel
Stand
Refrigeration Unit
Pump
Assembly
Mounting the Air Compressor onto a
Multiplex Support Stand
Installing the air compressor onto the support stand
1. Mount the air compressor mounting channel to left end of the Multiplex Support Stand with two (2) 1/4"­20 nuts and screws provided with kit (refer to figure above).
NOTE: Compressor may be mounted to the end of the refrigeration unit.
2. Install the air compressor assembly to the support stand and mounting channel with four (4) 1/4"-20 nuts and screws provided with kit (refer to figure above).
NOTE: Do not plug in pump assembly at this time. Shut “off” the main CO2 supply to refrigeration unit.
Refrigeration
Unit
2 of 9 Part Number 020006402 12/2014
Pump Assembly
Mounting the Air Compressor onto a
Multiplex Refrigeration Unit
Air Compressor Kits
Installing the air compressor onto a refrigeration unit
1. Align the air compressor assembly over the four (4) holes on left end of the Multiplex Refrigeration Unit. Secure to unit using the four (4) 1/4" screws provided in kit (refer to figure above).
NOTE: Do not plug in pump assembly at this time. Shut “off” main CO2 supply to refrigeration unit.
2. Locate the Air/CO2 Change-over Valve Assembly supplied with kit (P.N. 00212506). Align the mounting bracket of the change-over valve over the mounting holes on the control panel (location for change-over valve will be marked “Air/CO2 Change-over Valve”). Mount the air/co2 change-over valve to the panel with the #10-32 screws provided in kit (refer to figure below).
Air/CO2 Change-over
Valve
To Outlet Fitting
of Air Pump
To Syrup Tank
Supply Manifold
To C O
Manifold
Supply
2
CO2 Control Panel
Installing the optional dump valve onto the Multiplex refrigeration unit
1. Connect the 1/4" line assembly provided in kit (P.N.
00212506) to the flare fitting on right side of air/CO2 change-over valve. Route the other end of tubing to the CO2 supply manifold. Trim excess line and connect swivel nut adapter to the remaining end of line assembly. Secure with tab clamp. Connect the line assembly to the CO2 supply manifold (refer to figure below).
2. Locate the 4-1/2" section of 1/4" tubing connected at bottom side of change-over valve. Route and connect the remaining end of tubing to the syrup tank supply manifold (refer to figure above).
3. Locate the 12 ft x 1/4" EVA line assembly provided in air compressor kit. Attach the end of this line assembly, with the swivel nut, to the outlet fitting of the air compressor tank. Use 1/4" flare washers at swivel nut connectors. Neatly route tubing under the stand top and to the left side of the control panel. Connect the line assembly with 1/4" elbow x barb (provided in kit P.N. 00212506) to the 1/4" male flare fitting of the air/ CO2 change-over valve (refer to figure above).
4. Locate the dump valve supplied with kit. Mount the dump valve with #10-32 self-tapping screws provided with kit to lower left cross channel of support stand.
5. Locate the 3 ft length of tubing supplied with kit. Neatly route and attach this line from the air tank compression elbow to the shut-off valve compression fitting located on top of the dump valve. Trim tubing to correct length. Tighten compression nuts.
6. Locate the 8 ft length of tubing supplied with kit. Route and connect this line from the 1/4" barb elbow of the dump valve to a floor drain. Place the shut-off valve handle in the “open” position (refer to figure above).
7. Plug the air pump power supply cord into the power receptacle provided on wall. Pump will begin to run immediately and shut “off” when tank pressure reaches approximately 90 psi (6.2 bar). Pump will turn “on” when tank pressure drops to 70 psi (4.8 bar). If not, adjust pressure switch according to instructions located on the inside of pressure switch cover.
8. Turn the air/CO2 change-over valve to the “Air” position. Check for leaks.
Air Tank
Compression
Elbow
3 ft Length
of Tubing
Dump Valve
8 ft Length of Tubing
to Floor Drain
Mounting the Dump Valve onto the
Multiplex Refrigeration Unit
3 of 9 Part Number 020006402 12/2014