Multipipe 22-02403 User Manual

User Manual
Digital Programmable Thermostat 24V
Model No: 22-02403
NAVIGATION
1
Access the Main Menu by pressing the
Menu
Button.
2
Navigate through the menu by
pressing lower and higher entries.
for
+
3
for
Enter the selected topic by pressing
select
cancel
Button
.
the or leave to the previous menu without any changes by pres­sing
BASIC OPERATION
Change Display
The
Change
Menu
Display-
offers the
Screen Screen Screen
Full
,
Selected
and
Basic
view.
Program On/Off
In the
Program
Menu you can choose between
Program
or
Manual
operation
mode.
Change Profile
In the
Change
-Menu
Profile
you can choose between the
Family, Single, Office, Name 1
and
Name 2
Profile.
Key Lock
By pressing the
-
and + button for three seconds, a Key Lock can be activated to protect the device from failure operation.
Change Holiday
In the
Change
-Menu
Holiday
you can make your holidays settings and turn
On
or
Off
them
.
Manual operation
By pressing the or + buttons, the manual operation mode will be activated. Current Programs will be overwritten until the next daytime starts.
Digital Programmable Thermostat 24V
Model No: 22-02403
PROGRAM-MENU
To Enter the Program Menu, have to press + or - first. Before the follow procedure.
Program Menu
To access the
program
-menu,
open the hatch and
select
press
cancel
time for three seconds.
Profile
Enter the settings of the
and
1
You can adjust the profiles to your needs, by varying the 6 daytimes and allocate them new temerature zones. This can be done for a single day or weekday and weekend. You can rename profiles and copy settings inside a profile and from one profile to an other. In the following table, you can find the factory defaulted settings:
and
at the same
Profile
-Menu to adjust the detailed
Family, Single, Office, Name
Name 2
Profiles.
Temp. Zones
Basic Settings
Enter the
Settings
adjust
Language Maintenance
settings.
Daytimes Time Family Single Office Name 1 Name 2
Eearly Morning 06:00 - 08:00 Comfort Comfort Comfort Comfort Comfort Morning 08:00 - 12:00 Standard Standard Standard Standard Standard Noon 12:00 - 14:00 Comfort Comfort Comfort Comfort Comfort Afternoon 14:00 - 18:00 Standard Standard Standard Standard Standard Evening 18:00 - 23:00 Comfort Comfort Comfort Comfort Comfort Night 23:00 - 06:00 Reduced Reduced Reduced Reduced Reduced
Eearly Morning 06:00 - 08:00 Comfort Comfort Comfort Comfort Comfort Morning 08:00 - 12:00 Standard Standard Standard Standard Standard Noon 12:00 - 14:00 Comfort Comfort Comfort Comfort Comfort Afternoon 14:00 - 18:00 Standard Standard Standard Standard Standard
SAT - SUN MON - FRI
Evening 18:00 - 23:00 Comfort Comfort Comfort Comfort Comfort Night 23:00 - 06:00 Reduced Reduced Reduced Reduced Reduced
Basic
- Menu to
Date/ Time,
and
Enter the Menu to adjust the
temperatures of the Comfort, Standard and
Reduced zones.
The three temperature zones can be allocated to the six day times. If you modify a temperature
zone, the temperature­settings within the profiles
will change as well. The zones are factory defaulted
with these temeratures:
Comfort 24°C Standard 20°C Reduced 16°C
Temp. Zones
-
Do not dispose of batteries with general household refuse. Please take battery to municipal collection point or dispose with trade waste.
www.multipipe.co.uk
Heat/Cool Control
Enter the
Heat/Cool
Menu to activate the
Heat
control of the device.
or
-
Cool
Control
Enter the Menu to make changes on the
Span, SetBack, Frost*, Output VP
* Thermostat serves as protection against frost and prevents temperature from going below 5°C.
A
C
Control
and
settings.
Purpose and correct use:
-
This standalone mounted electronic device serves as a temperature control system only in dry and closed living and office spaces. This thermostat may be opened, installed or repaired only by qualified electricians. These professionals must observe existing standards and regulations. Clean device only with a dry and soft cloth. Do not use solvents or aggressive cleaning agents! The manufacturer accepts no responsibility for damage caused by non-observance of these instructions.
Dimensions
A - 80 mm
B - 130 mm
Changing the batteries
2 x AA Batteries
C - 30 mm
B
Multipipe Ltd
Unit 12 Great Hayes Business Park Lower Burnham Road Stow Maries Chelmsford Essex CM3 6SQ
Sales
T: 01245 227630 E: sales@multipipe.co.uk
Technical T: 01245 850799 E: technical@multipipe.co.uk
Loading...