MULTI MEASURING INSTRUMENTS CO.,LTD. ALCL–40H Instruction Manual

LEAKAGE CLAMP TESTER FOR ARRESTER
ALCL – 40H
INSTRUCTION MANUAL
Thank you very much for selecting our model ALCL-40H
Before use the instrument, read this instruction manual
completely and familiarize yourself thoroughly with all
functions.
Keep this instruction manual carefully to take out
whenever you need.
MULTI MEASURING INSTRUMENTS CO.,LTD.
Akihabara Murai Bldg. 7F, 1-26 Kanda Sakuma-cho,
Chiyoda-ku, Tokyo, Japan, 101-0025
TEL : +81-3-3251-7016 FAX : +81-3-3253-4278
Home Page : http://www.mutimic.com/
E-mail : multi@multimic.com
SAFETY SUMMARY observe by all means
To use this instrument safely, read this "SAFETY SUMMARY" carefully and apply
the instrument correctly.
The CAUTIONs and WARNINGs which appear on the following pages are stated to prevent the operator & other people from the dangers and their properties from the damages beforehand.
WARNING : This symbol indicates the contents "Possibilities of the death or the serious wound can be supposed" caused from mis-operations. CAUTION : This symbol indicates the contents "Possibilities of the injury or
only the material damage can be supposed" caused from mis- operations.
OPERATION ENVIRONMENT
CAUTION
Do not use or storage this instrument under the condition of direct rays of the
sun.High temperature & humidity and or condensation, as it may cause the
deformation and or the isolation defect of the instrument.
Do not use this instrument in the environment influenced by acids, alkalis, organic solutions. corrosive gas, etc.
Do not use or storage this instrument where the mechanical vibration can be directly transmitted, as it may cause defect of the instrument.
Do not use this instrument nearby the appliances which generate strong magnetic field and or electric field, as it may cause mis-movement of the instrument.
This instrument does not have the water / dust-proof structure. Do not use this instrument in the environment with a lot of dust and drops of water, as it may
cause defect of the instrument.
OPERATION CONDITION & CONNECTION
WARNING
POSSIBLE ELECTRICAL SHOCK
This instrument is for the use of low voltage circuit. Do not make measurements of power lines carrying more than AC 500V. Before use, check and confirm the voltage of circuit to be measured.
Apply only the coated cables and do not clamp bare cables.
POSSIBLE ELECTRICAL SHOCK OR ACCIDENT
Do not handle the instrument in the rain, at humid place, with a drop of water and
or with wet hands.
Do not use the instrument if the CT or CT case are damaged and if something is wrong with the CT cables.
If excessive current is applied to the CT, the instrument will be heated and
damaged. Use the CT according to the rating current.
1. GENERAL
This leakage clamp tester model ALCL-40H mainly measures quite low & sensitive leakage current very accurately.
At 300μA range, the minimum resolution is 0.1μA. Using ultra accurate CT which is hardly influenced by external magnetic field. Voltage output terminal for oscilloscope, etc. to see the wave form.
2. SPECIFICATIONS
(1) Measuring Function :Leakage Current, Harmonic Current (Dominant & Third) (2) Measuring Method : CT Clamp-on Method (3) Measuring Range : 0-300μA/3mA/30mA(3range manual) (4) Input Frequency : 45-60Hz(Dominant Wave Frequency) (5) AC Conversion : RMS Detection Method (6) A/D Conversion : Double Integration Method (7) Display : 3200 count max., LCD (8) Voltage Output : 300mV full scale for each range (9) Sampling Rate : 2 times/second (10) Over Indication : "OL" on the display (11) Low Battery Indication : "B" sign on the display (12) Data Hold Function : "DH" sign on the display (13) Auto Power Off : Approx. 10 minutes after power on (14) Max. Jaw Opening : φ37mm (15) Power Supply : 9V Alkaline Battery (6LR61) (16) Power Consumption : Approx. 20mW (17) Operating Circuit Voltage : Less than 500V AC (18) Operating Temperature : 040, less than 80%RH, w/o condensation
(19) Storage Temperature : -1060, less than 70%RH, w/o condensation (20) Dimensions/Weight : Unit:/95(W)x160(H)x34(D)mm, 260gs CT:/135(W)x166(H)x61(D)mm, 1000gs (21) Accessories : Battery 6LR61x1, CT Carrying Case, Instruction Manual BNC Connector (Option)
Accuracy (23℃±5, less than 80%RH)
(1) AC Current
Range
Resolution
Accuracy(4565Hz)
Max.Applicable Current
300μA
100nA(0.1μA)
1.2%±8digit
40A rms
3mA
1μA(0.001mA)
30mA
10μA(0.01mA)
AC Conversion : RMS Detection Method Crest Factor : 3 (050% of the range) 2(50100% of the range)
(2) Harmonic Current (Dominant Current, 3rd Harmonic Current) Detection Method : Automatic Tuned Filter Min. Dominant Current Input : more than 3% of each range Accuracy : (1%±5digit)±(AC Current Accuracy)