When using your telephone equipment, basic safety precautions should
always be followed to reduce the risk of fire, electric shock and injury to
persons, including the following:
1. Do not use this product near water, for example, near a bath tub, wash
bowl, kitchen sink or laundry tub, in a wet basement or near a swimming
pool.
2. Avoid using a telephone (other than a cordless type) during an
electrical storm. There may be a remote risk of electric shock from
lightning.
3. Do not use the telephone to report a gas leak in the vicinity of the leak.
4. Use only the power cord and batteries indicated in this manual. Do not
dispose of batteries in a fire. They may explode. Check with local codes
for possible special disposal instructions.
5. Plug the adaptor to the socket-outlet that near the equipment and
shall be easily accessible.
SAVE THESE INSTRUCTIONS
Attention
This product is not an alarm system providing facilities to summon
assistance, for use by persons who can be considered to be living
at risk. This product is not intended to for use in health care signaling
equipment or directly connect to central-station (Police, Medical, Fire).
–1–
IC Statement
‘’This product meets the applicable Industry Canada technical
specifications.”
Before installing this equipment, users should ensure that it is permissible
to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method
of connection. In some cases, the company’s inside wiring associated
with a single line individual service may be extended by means of a
certified connector assembly (telephone extension cord). The customer
should be aware that compliance with the above conditions may not
prevent degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian
maintenance facility designated by the supplier. Any repairs or alterations
made by the user to this equipment, or equipment malfunctions, may give
the telecommunications company cause to request the user to disconnect
the equipment.
Users should ensure for their own protection that the electrical ground
connections of the power utility, telephone lines and internal metallic water
pipe system, if present, are connected together. This precaution may be
particularly important in rural areas.
Caution: Users should not attempt to make such connections themselves,
but should contact the appropriate electric inspection authority, or electrician, as appropriate.
Declaration of Conformity
Application of Council Directive(s) :
Radio Equipment and Telecommunication Terminal Equipment
Directive (1999/5/EC) - R&TTE
Standard(s) to which Conformity is Declared:
EMC:
EN 55022:1998+A1: 2000, EN 610000-3-2: 2000,
EN 61000-3.3: 1995 +A1:2001, EN 55024: 1998+A1: 2001,
EN 50130-4: 1995/A1: 1998, EN 300220-3: 2000,
EN 301489-3: 2002
Safety:
EN 60950-1: 2001, EN 50371: 2002
Telephony:
TBR 21: 1998
Manufacturer’s Name:Capital Prospect Limited
Manufacturer’s Address:Room 3, 13/F, Block B, Veristrong Industrial Centre,
‘’The Ringer Equivalence Number is an indication of the maximum
number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination
of devices subject only to the requirement that the sum of the Ringer
Equivalence Numbers of all the devices does not exceed five.’’
–2–
Year of Manufacture:2005
I, the undersigned, hereby declare that the equipment specified above conforms to the above
g)Should you experience trouble with this equipment, please contact
Skylink Customer Support at 1-800-304-1187 for repair or warranty
information. If the equipment is causing harm to the telephone network,
the telephone company may request that you disconnect the equipment
until the problem is resolved.
h)Please follow instructions for repairing if any (e.g. battery replacement
section); otherwise do not alternate or repair any parts of device except
specified.
i)Connection to party line service is subject to state tariffs. Contact the
state public utility commission, public service commission or corporation
commission for information.
j)NOTICE: If your home has specially wired alarm equipment connected to
the telephone line, ensure the installation of this model AM-002 does not
disable your alarm equipment. If you have questions about what will
disable alarm equipment, consult your telephone company or a qualified installer.
NOTICE: According to telephone company reports, AC electrical surges,
typically resulting from lightning strikes, are very destructive to telephone
equipment connected to AC power sources. To minimize damage from
these types of surges, a surge arrestor is recommended.
Congratulations on your purchase of a Home Smart Center. This is a security
control panel which not only functions as a security system, but also monitors
your premises by giving you alert notification when the system is not armed. It
is also a home automation center, which allows you to remotely control household appliances and lights, even when you are away from home. It can be
controlled by dialing in from any touch tone phone, which makes it even more
convenient and powerful. Additional accessories such as different kinds of
sensors and controllers can be added to suit your specific needs.
This user instructions will guide you through the whole setup procedure as well
as all the programming instructions. Please follow the instructions closely, you
should find it very easy to set up the system.
Alert
When Home (System Not Armed)
Beep Beep
Alarm
Not Home (System Armed)
Alarm
In the package, you should find the following items:
Automation
Communicator
Zone 1
Sensor 1
Triggered
•One Control Panel
a)This equipment complies with Part 68 of the FCC rules and the require-
ments adopted by the ACTA. On the bottom of this equipment is a label
that contains, among other information, a product identifier in the format
US:AAAEQ##TXXXX.
If requested, this number must be provided to the
telephone company.
b)An applicable certification jacks Universal Service Order Codes (USOC)
for the equipment is provided (i.e.,
RJ11C
) in the packaging with each
piece of approved terminal equipment.
c)A plug and jack used to connect this equipment to the premises wiring
and telephone network must comply with the applicable FCC Part 68
rules and requirements adopted by the ACTA. A compliant telephone
cord and modular plug is provided with this product. It is designed to be
connected to a compatible modular jack that is also compliant. See
installation instructions for details.
d)The REN is used to determine the number of devices that may be con-
nected to a telephone line. Excessive RENs on a telephone line may
result in the devices not ringing in response to an incoming call. In most
but not all areas, the sum of RENs should not exceed five (5.0). To be
certain of the number of devices that may be connected to a line, as
determined by the total RENs, contact the local telephone company. [For
products approved after July 23, 2001, the REN for this product is part of
the product identifier that has the format
represented by ## are the REN without a decimal point
US:AAAEQ##TXXXX
(e.g
. The digits
., 03 is a
REN of 0.3). For earlier products, the REN is separately shown on the label.]
•One Motion Sensor (For ML-100A Only)
•Two Door / Window Sensors (For ML-100A Only)
•One Keychain Remote (For ML-100A Only)
–4–
ML-001A
PS-101
WD-101
4B-101
e)If this equipment AM-002 causes harm to the telephone network, the
telephone company will notify you in advance that temporary discontinu-
ance of service may be required. But if advance notice isn’t practical, the
telephone company will notify the customer as soon as possible. Also,
you will be advised of your right to file a complaint with the FCC if you
believe it is necessary.
f) The telephone company may make changes in its facilities, equipment,
operations or procedures that could affect the operation of the equipment.
If this happens the telephone company will provide advance notice in
order for you to make necessary modifications to maintain uninterrupted
service.
–53–
SYSTEM CONFIGURATION
INTRODUCTION
Master Password____________________
Secondary Password____________________
Duress Password____________________
Sensor locations and settings
ZONESENSOR 1SENSOR 2BEEP / ALARM AUTO MUTEEVENT TRIGGER ALERT
Example
Front DoorFront WindowBeep / AlarmY / NDisabled / On / OffY / N
1
2
3
4
5
Phone number settings
PHONE MEMORYPHONE NUMBERREDIAL COUNTREPEAT COUNT
Example
1
2
3
4
5
321-123-456755
Keychain / Keypad Remotes settings
•One AC adapter
•One telephone cord
•Batteries for all sensors (For ML-100A Only)
- 1 PC 9V Alkaline Battery (PS-101)
- 1 PC 12V Alkaline Battery Type 23A
(4B-101 -installed)
Control Module SW-101U (UK), SW-101F
(French), SW-101G (German)
(3 models for 3 countries)
- To turn home appliances / lights on / off
13
12
1. Zone LEDs
2. Numeric Keypad
3. Arm button
4. Status button
5. Mute button
6. Panic button
7. Power LED
8. Arm LED
9. Program LED
10. System Low Battery LED
18
16
11. Built-in Siren and Speaker
12. Programming button
13. Buzzer Mode Selector
14. Phone Jack for external phone
15. Line Jack for telephone line
16. Adapter socket
17. Battery Compartment
18. Language Selector (only available for
models support multiple languages)
17
15
14
Emergency Dialer (AD-433S)
905-608-9223
®
AD-433
- External dialer with user programmable voice
message
- Calls up to 9 phone numbers
- One personal voice recording up to 40 seconds
- Can be installed anywhere within 100 feet from
the control panel, with a phone socket
Swing door opener (DM-100)
- Remotely open / close a swing door
- Fits most interior doors
–6–
–51–
ACCESSORIES
Audio Sensor (AS-101)
- When audio level exceeds preset limit, it will trigger the
alarm
- Place beside smoke detector, CO detector, so when these
detectors are triggered, the control panel will be triggered
Remote Control (4B-101)
- Additional keychain remotes for other family members
- To arm, disarm or trigger the panic alarm with this remote
INSTALLATION
Installing the Console
It is important determine where the control panel will be located. Please follow
the criteria below to select the ideal location for the control panel.
-Place it where electrical outlet and phone line can be accessed
-Place it where it is easily accessible by the users
-Place it away from any doors or windows which could be accessed by
non-intended users
-Place is away from extreme temperature sources such as oven, stove
and away from large metal objects which could affect the wireless
performance
After a location has been selected, you may begin the installation and connect all
the necessary wires and power up the unit.
®
- External keypad control
- To arm, disarm or trigger the the panic alarm with this
remote
- Ideal mounting locations include upper floor, backdoor, or
garage
1. Undo the 2 screws on the battery cover.
Wrist Watch Style Panic Remote (HW-101)
Keypad Control (KP-434)
- Activate the panic alarm instantly with this remote
- Wear it as a watch
- Splashproof design, can be worn during showering
Panic Transmitter (PT-101)
- Activate the panic alarm instantly with this remote
- Wear it as a pendant
- Splashproof design, can be worn during showering
®
A
A
-
4
3
3
Audio Alarm (AA-433)
- External Siren
- Powered by AC adapter with backup battery
2. For models support multiple languages,
select the desired language based on
the setting below:
1.German
2.Spanish
3.French
4.English
3. Connect the power adapter to the
socket inside the battery compartment. The power adapter should
be connected to an AC electrical
outlet. You should see all LEDs
turn on, LO BATT LED should be
off.
Language
selector
–50–
–7–
INSTALLATION
ACCESSORIES
4. Insert the rechargeable battery to the battery compartment. There are 2
different types of rechargeable battery for 2 markets:
North American Version: Lead Acid
a.
Connect the 2 wires to the battery. Red wire
connects to the “+” terminal on the battery.
Black wire connects to the “-” terminal on the
battery. Markings on the battery should face up.
b. European Version: Ni-MH
Plug in the wire from the battery to the battery
socket inside the battery compartment.
5.After inserting the rechargeable battery, the LO
BATT LED will be off if the battery is fully
charged, otherwise it will be on.
6.Connect the phone line from the wall socket to
the “LINE” socket inside the battery
compartment.
7.[OPTIONAL] If another telephone that will be
using the same telephone jack, you may
connect this telephone to “PHONE” outlet of the
control panel by a phone cord (not provided).
8.The phone line(s), cord of the power adapter
should all come out from the lower right corner
of the control panel in order to close the battery
cover properly.
9.The battery cover can now be closed, and tighten
the 2 screws to secure the battery cover.
PWR, ARM, PROG LEDs should be flashing,
zone LEDs should be off.
10. The control panel is intended to be mounted on a
flat wall. 2 screws are required to mount the
control panel securely on the wall. It should not be
mounted too high or too low. In most situations, just
below eye level is ideal.
11. Once you have selected the mounting
location, tighten 2 screws on the wall.
They should be
7-1/8" apart from each other, on the same
horizontal level. Do not tighten the screws
all the way in, leave about 1/8" from the
wall in order for the control panel to be
hanged onto the wall.
7-1/8"
–8–
(Optional)
Additional sensors and transmitters as well as add on accessories are available
to work with your system.
Door/Window Sensor (WD-101)
- Magnetic Contact Sensor
- For all doors or windows
- Batteries included
Repeater (RP-434)
- Extend the operation range between 2 wireless devices,
such as any sensors and control panel
- Doubles the operation range automatically between
sensors and control panel
Water Sensor (FS-101)
- Alerts you when water is detected
- Ideal for water detection in basement, under the sink, even
bathroom
Garage Door MonitorTM Sensor (GS-101)
(Available in US and Canada)
- Monitors your garage door
- Alerts you when the garage door is left open
Garage Door MonitorTM Sensor (GS-102)
(Available outside US and Canada)
- Monitors your garage door
- Alerts you when the garage door is left open
Indoor/Outdoor Motion Sensor (PS-101)
- Monitors area in a 110 degree ARC and up to 40 feet away
TM
from the sensor
–49–
TROUBLE SHOOTING
INSTALLATION
Sensors
When a sensor is triggered, the- Make sure the battery in the sensor is
control panel doesn’t respond at all, installed properly, pay attention to the
what is the problem? polarity.
- Make sure the sensor is learned to the
control panel. Follow instructions on
page 37 on how to learn a sensor.
- You may try to bring the sensor closer to
the control panel, ensure it is not out of
the operation range.
My motion sensor sometimes getsEnsure the motion sensor is not facing
triggered by itself, how can I preventdirect sunlight, nor any A/C or furnace
that?vents. You may also reduce the sensitivity
to low. If your motion sensor is located
outdoors, you may want to relocate it.
After mounting the door sensor, it- Please ensure the magnet is aligned with
doesn’t work anymore. the red marking on the transmitter.
- If you are mounting the sensor on to a
metal door or window, a spacer may be
required to avoid magnetic interference
caused by the metal door / window.
- Make sure the sensor is within the operation
range of the control panel by bringing it
closer to the control panel.
My motion sensor is not veryThe motion sensor is designed to detect the
responsive, sometimes when I walk“First Motion”. First Motion means no motion
by it, the control panel doesn’t respond,is detected within the past 20 seconds,
but sometimes it does.and if a motion is then detected, that is the
“First Motion”. So if you continue to walk
in front of the motion sensor, it will only
pick up the first motion. Unless you wait
for 20 seconds, then walk again, the control
panel will respond. Otherwise, the control
will only respond to the first motion.
Programming Passwords
Master Password can be used for programming, arming, disarming the
system, and telephone access. The default Master Password is [1234].
Secondary Passwordcan be used for arming, disarming the system, and
telephone access. Secondary Password cannot be used for programming.
The default Secondary Password is [0000].
Duress Password is used when you are forcibly compelled to disarm the
control panel. Entering the duress password will stop the siren from sounding
but the control panel will silently call the emergency phone numbers for help.
The default Duress Password is [3838]. You should definitely change this
password and let all the users know this password.
Changing Passwords
It is strongly recommended to change all 3 passwords when you first set
up the system.
In order to change the password, follow the procedures below.
StepKeysFunctionDescriptionNote
1
2
3
[PROG]
[MPIN]
[2]
[1] or
[2] or
[3]
Enter
Programming
mode
Select
password
programming
Select which
password to
change
Enter master3 beeps for valid
password topassword. 1 long
programming modebeep for invalid
Select any 4-digit password, each digit can be
from 0 to 9
Enter the new password3 beeps if new passagain for confirmationword is accepted. You
will hear [Password
Accepted]
–9–
INSTALLATION
TROUBLE SHOOTING
Phone Number Programming
You can program up to 6 Emergency Phone Numbers. When the system is in panic,
the control panel will call these phone numbers and announce its status.
The 6 emergency phone numbers include:
- 5 voice message phone numbers
- 1 Contact ID message phone number
Program the following for Voice Message Phone Numbers
- Phone memory (from 1 to 5), this is where the phone numbers will be stored
- Phone number, up to 29 digits.
- Redial count, this is how many times that phone number will be called, from 1
to 9 times.
- Repeat count, this is how many times the emergency message will be repeated,
from 1 to 9 times.
StepKeysFunctionDescriptionNote
1
2
3
4
5
6
[PROG]
[MPIN]
[1]
[1] to [5]
[Phone
number]
+ [Arm]
[1] to [9]
+ [Arm]
[1] to [9]
+ [Arm]
Enter
Programming
mode
Select phone
number
programming
Enter phone
memory
Enter phone
number
Enter Redial
count
Enter Repeat
count
**Note:
You may enter a 3-second pause between digits by pressing [Mute] if needed.
You may also enter consecutive multiple pause periods. For example, you may
enter a phone number: (123)-456-7890 [Mute] 1234. After the phone number
(123)-456-7890 is dialed, it will wait for 3 seconds, then dial 1234, which can be
a password to a paging system, or an access code for a phone dialing system.
Enter master password to
programming mode
During emergency, phone
memory 1 will be called first,
then phone memory 2, 3, 4, and
5. So phone memory 1 has
higher priority.
Phone number can be up to 29
digits.**
Redial is the number of times
that phone number will be
called. Each phone number
can have a different redial
count, from 1 to 9 times.
Repeat is the number of times
that voice emergency message
will be played, from 1 to 9 times.
It is recommended to set up
the repeat time to 5 or more.
3 beeps for valid
password. 1 long beep
for invalid password.
You will hear [Enterphone memory].
You will hear [Enter Redial].
You will hear [EnterRepeat].
You will hear [PhoneAccepted] indicating the
phone number and its
settings have been
programmed successfully.
Control Panel
QuestionsSolutions
Why I can’t arm my system?Make sure none of the sensors are
triggered. You can check this by the zone
LEDs, none of them should blink.
I cannot arm the system even when noYou need to disarm the system again by
sensor is triggered, and the ARM LEDeither entering the password or disarm by
is off.keychain remote. Although the ARM LED
is off, but the system is not completely
disarmed after an alarm was triggered.
Refer to page 22 on how to completely
disarm a control panel after an alarm has
been triggered.
Why the ARM LED keeps flashing?That means you have not programmed any
emergency phone numbers. For instructions
on how to program emergency phone
numbers, please see page 10.
How do I exit programming modeYou can press the programming button on
when I’m in the middle of it?the side of the unit to quit programming
anytime.
When a sensor is triggered, the alarmYou have programmed that sensor in alarm
sounds instantly even it is not armed,mode, instead of beep mode. Please refer
why is that?to page 29 for instructions of how to program
it back to beep mode.
When the alarm is triggered, whyThe control panel will stop calling when it
the control panel won’t call all theis disarmed by any one of the recipients.
programmed phone numbers? ItDisarm can also be done locally thru the
always stops before calling thekeypad on the control panel by entering a
last number.valid password.
Why the control panel doesn’t beepYou have placed the buzzer mode selector
when a sensor is triggered, whileon the side of the control panel to “II”, this
only the zone LED flashes?will disable the beeping. Placing it to “I” will
enable the beeping.
The control panel is in armed mode,If the triggered sensor is programmed in the
why activating a sensor will not causeAlert Zone (Bypass Zone), alarm will not
an alarm, or call any emergency phonesound, and emergency call will not be made
number?if this sensor is triggered. The control panel
will only respond when it is disarmed, in
alert mode.
–10–
–47–
Zone 1
®
Zone 2
Zone 3
Zone 4
Zone 5
HOME AUTOMATION
DISABLE EVENT TRIGGER
Button [1]
Button [2]
Button [3]
Button [4]
Button [5]
This row :
Buttons to Disable Event Tigger
Zone LED : Off
This row :
Buttons to Enable Event Trigger
Zone LED : 1) On (Event Trigger On)
ENABLE EVENT TRIGGER
Button [6]
Button [7]
Button [8]
Button [9]
Button [0]
Press once will enable “Event Trigger On”,
press again will enable “Event Trigger Off”.
This row of buttons operates in toggle manner,
between event trigger on and event trigger off.
2) Flash (Event Trigger Off)
INSTALLATION
Note:
- It’s not recommended to program 911, fire station or any emergency services
phone numbers into any of the phone memories without their approvals.
- Ensure to program a valid phone number and write down the programmed
phone number on the System Setting Information provide on the back of this
user's instructions.
- You may quit programming by pressing [PROG] button at any time.
- If no phone number is programmed, the ARM LED will continue to flash.
Testing Phone Numbers:
After you have programmed all the phone numbers, you should verify you have
programmed the phone numbers correctly. This can be done by triggering the
alarm silently by entering the duress password, so it dials to the programmed
phone numbers without sounding the alarm.
Note:
You must inform the recipients of the programmed phone numbers, so they know
what to expect when they receive the phone call from the control panel during an
emergency. These recipients should know the password to your control panel if
you expect them to have remote access of your control panel. For more information regarding receiving the emergency call, please refer to page 26.
1. Press [Arm], you should hear beeping from the control panel.
2. Press [3838]. Beeping will stop, and the control panel will start to dial the first number.
3. The called party should receive the call. Pick up the call and say “Hello”, an
emergency message “System Panic” will be played. If the programmed phone
doesn’t ring, ensure the phone number is programmed correctly, or reprogram
this phone number again.
4. After the emergency message has been played for several times (depending on
how many times it was programmed), the called party will hear “Enter Password”.
5. Enter either the master password or secondary password. If the correct
password is accepted, you will hear “Password Accepted”, otherwise, you will
hear “Password Failure”.
6. Press [0][#] on the telephone to hang up.
7. The control panel will start to dial the next programmed phone number.
Note:
- Refer to page 26 [Receiving the Emergency Call] for more info on how to react
to an emergency call.
- The password is treated as a confirmation of the emergency message. Once a
valid password is entered, the control panel will not call that number again, it
will proceed to the next number.
- If any one of the called parties disarms the control panel, the control panel will
not continue to dial the remaining phone numbers.
- After calling all the programmed phone numbers, the control panel will be back
to the previous operation mode.
–46–
–11–
INSTALLATION
HOME AUTOMATION
Contact ID Phone number
You can program a telephone number for calling to the central monitoring station.
When the system is in panic, the control panel will call this phone number and
will send out a Contact ID message with event code 140, which represents
“General Alarm”.
Follow the instructions below to program the necessary info in order to call a
monitoring station:
- Phone number of central monitoring station (up to 29 digits)
- Account number given by the Central Monitoring Station
Phone Number Programming (Calling to Central Monitoring Station)
Step Keys Function Description Note
1
2
3
4
Press [PROG]
Press [MPIN]
Press [1]
Press [0]
Enter [Phone
number] +
[Arm]
Enter Programming mode
Select phone
number
programming
Enter phone
memory
Enter phone
number
Enter master
password to
programming mode
During emergency,
the Contact ID phone
number has the highest
priority, it will be the
first number to call.
Phone number
can be up to 29
digits.
3 beeps for valid
password. 1 long
beep for invalid
password.
You will hear
[Enter Phone
Memory]
You will hear
[Phone Zero]
You will hear
[Phone Accepted]
indicating the phone
number has been
programmed
successfully.
–12–
Event Trigger
You can control up to 5 different devices not only manually, but also automatically. It is
called Event Trigger. That means when a sensor is triggered, the control panel will
transmit a signal to activate the designated control module. Applications include:
- Lights on when you open the front door
(walking into a room, lights on automatically),
this is called "Event Trigger on".
- Lights off when you open a door. (walk away
from a room, turns lights off), this is called
"Event Triggered off".
Event trigger is only applicable to the sensor(s)
and control module in the same zone. For
example, you can program control module 1 to
be on or off when zone 1 sensor(s) is triggered.
You can also program control module 2 to be
on / off when zone 2 sensor(s) is triggered.
Factory Default: This feature is disabled for
all zones at the factory.
To change the event trigger setting follow the instructions below.
StepKeysFunctionDescriptionNote
1
2
3
4
[PROG]
[MPIN]
[7]
Disable Event
Trigger: [1] to
[5]
Enable Event
Trigger: [6] to
[0].
[PROG]
when
finished.
Enter Programming mode
Select Event
Trigger
Select which
zone you would
like to enable /
disable event
trigger.
Terminate
programming
mode.
Enter master
password to
programming
mode
Refer to the
diagram below
to select the
appropriate
setting.
Event Trigger On
Event Trigger Off
3 beeps for valid
password. 1 long beep
for invalid password.
After [7] is entered,
some zone LEDs will be
off, on or flash. This
indicates the setting of
event trigger.
If event trigger “ON” is
enabled, that zone LED will
be on. If event trigger “OFF”
is enabled, that zone LED
will flash. If it is disabled, the
zone LED will be off. You are
allowed to make multiple
changes before terminating
programming mode.
PROG LED
will be off.
–45–
HOME AUTOMATION
INSTALLATION
ZONE LEDDESCRIPTION
OffZone is not occupied by any control module
Flashes twiceThat means a remote has occupied that zone.
Flashes onceThat zone is occupied by a control module. You may select this
Flashes once,That means this zone is occupied by a remote AND a control module.
then twiceYou may select this zone to erase the control module.
THIS IS NOT A CONTROL MODULE, THEREFORE, SHOULD NOT BE
ERASED.
zone to erase this control module.
** Table F: Zone LED status for erasing control module.
Part 2 Erase communication from Control Panel to Control Module
StepKeysFunctionDescriptionNote
1
2To erase the
Remove the
control module
from the
electrical outlet
Press and hold
the learn button
on the control
module while
plugging in the
control module
to an electrical
outlet.
memory of the
control module
Control module LED
will flash rapidly
indicating all the
memory is erased.
You may now
release the learn
button.
Once the memory of the control module is erased, all of its memory is cleared. If
you have other remotes / control panels controlling this control module, you need
to re-program those remotes / control panels.
Account Number Programming
In order to program the account number, follow the procedures follow:
Step Keys Function Description Note
1
2
3
4
5
Press [PROG]
Press [MPIN]
Press [2]
Press [0]
Enter [New 4digit Account
Number]
Enter [New 4digit Account
Number]
Enter
Programming
mode
Select
password
programming
Select to
add / change
account
number
Enter new
account
number
Enter the new
account number again for
confirmation
Enter master
password to
programming
mode
[0] = Add/change
account number
Enter the 4-digit
account number
given by the
central monitoring
station.
3 beeps for valid
password. 1 long beep
for invalid password.
This number can be a
combination of 0-9,
B,C,D,E & F.
To enter 0-9:
Enter by the keypad 0-9
directly.
To enter B,C,D,E,F:
Press [STATUS] and the
ARM light will stay on.
Then press the following
keys for the corresponding letters (1=B, 2=C, 3=D,
4=E, 5=F).
Press [STATUS] to return
back to number-mode
when you want to input
numbers. The ARM light
will turn off.
You can toggle between
the number or letter mode
by pressing [STATUS]
when entering the
account number.
3 beeps if new account
number is accepted. You
will hear [Password
Accepted]
–44–
–13–
INSTALLATION
HOME AUTOMATION
Deactivating the Digital Dialer
You can deactivate the digital dialer by erase the phone number memory for
central monitoring station.
Step Keys Function Description Note
1
2
3
4
Press [PROG]
Press [MPIN]
Press [1]
Press [0]
Press [ARM]
Enter Programming mode
Select phone
number
programming
Enter phone
memory
Confirm delete
the phone
number.
Note: If no phone number is programmed to call the central monitoring station,
the digital dialer is automatically disabled.
Enter master
password to
programming mode
3 beeps for valid
password. 1 long
beep for invalid
password.
You will hear:
[Enter Phone
Memory]
You will hear
[Phone Zero
Empty Memory]
indicating the phone
number have been
deleted, the digital
dialer is deactivated.
Operation
To turn off a light with the control panel:
1.Press the device number button on the control panel, i.e. pressing 1 will turn
off device 1, pressing 2 will turn off device 2.
2.You will hear [Device X Off], where X is the device number.
3.You will also see the PROG LED flashing, indicating the control panel is
sending out the wireless signal to control the specific device.
4.If the receiver receives the signal, the control panel will announce [DeviceOff Accepted].
To turn on a light with the control panel:
1.Press the number below the device number that you would like to turn on, i.e.
pressing 6 will turn on device 1, pressing 7 will turn on device 2.
2.You will hear [Device X On], where X is the device number.
3.You will also see the PROG LED flashing, indicating the control panel is
sending out the wireless signal to control the specific device.
4.If the receiver receives the signal, the control panel will announce [Device
On Accepted].
Erase Control Modules
To erase a control module from the control panel, it is similar to learning a
control module, which involves 2 parts.
1. Erase the memory of the control panel
2. Erase the memory of the control module
–14–
Part 1 Erase the memory of the Control Panel
StepKeysFunctionDescriptionNote
1
2
3
[PROG]
[MPIN]
[0]
To erase an
occupied
control module,
press [1] to [5].
Enter
Programming
mode
Select erase
control
module
programming
Select the
control module
location you
would like to
erase
Enter master
password to
programming mode
Refer to the table
below to select
the control
module location.
3 beeps for valid
password. 1 long beep
for invalid password.
After [0] is entered, some
zone LEDs will flash or
stay off. The zone LEDs
represent whether that zone
is occupied by any control
module. **See Table F
After you have selected the
remote location, you will
hear 3 beeps and verbal
confirmation [Device XEmpty Memory], where
X is the control module
location you have selected.
–43–
HOME AUTOMATION
INSTALLATION (ML-100A Only)
Control Module [1] is represented by zone LED 1
This row :
Buttons for
Learning Control Module
Part 2 Learn signal from Control Panel to Control Module
StepKeysFunctionDescriptionNote
1
2
Press and hold
the learn button
on the Control
Module until its
LED starts to
flash.
[6] to [0]
Enter
Programming
mode
Transmit an ON
signal for the
selected device
from the Control
Panel to the
Control Module.
Refer to the
chart below to
determine which
button [6] to [0]
to press.
You should
transmit the “ON”
command for the
selected device.
LED on the Control Module
will flash indicating it is in
learn mode.
After [X] is entered, you
will hear [Device X On]
indicating you have transmitted an ON signal for
device X, where X is the
Control Module Location.
The LED on the Control
Module should be off,
indicating it has learned
the signal, you may now
release the learn button
and the LED will stay on
again.
Installing Door / Window Sensors
Window / Door Sensor is used to monitor doors or windows that
open and close. When these doors / windows are open or
closed, the sensors will transmit a signal to the control panel
to notify the user. These sensors consist of 2 parts, one is the
transmitter, the other is the magnet.
Transmitter
Magnet
Before installing the sensor, remove the battery isolator by pulling out the yellow
tab. Once the isolator is removed, the corresponding zone LED on the control
panel will flash and buzzer will beep. If the magnetic contact is closed, the
beeping will stop.
Note:
- Both Window/Door Sensors have been programmed at the factory. They are
Zone 1 Sensor 1 and Zone 2 Sensor 1. Trigger the sensor and listen to the
beeping and zone LED to determine which one is zone 1 and which is zone 2.
Mounting the Sensor
The transmitters should be mounted on the door frame or window frame by
double sided tape. The magnet should be mounted on the door or window by
either double sided tape or screws. Make sure the magnet is aligned with the
red marking on the transmitter. If the surface of the frame is flat enough, doublesided foam tape is sufficient, otherwise, it is recommended to screw the
mounting plate to the frame, then apply double sided tape. After mounting the
sensor, if the AAA+ logo is inverted, remove the front cover and rotate it so the
AAA+ logo is in the upright position.
CONTROL MODULE
LOCATION
16
27
38
49
50
TRANSMIT
BUTTON [X]
–42–
Magnet on the left
Magnet on the right
Mounting plate
and screws
(optional)
Double-sided
foam tape
Sensor
Testing:
After mounting the sensor, test the sensor by opening and closing the door or
window. Open the door or window will result in the followng:
1. Beeping - The number of beep represents the zone number.
2. Zone LED flashing - Number of flash represents the sensor number.
–15–
INSTALLATION (ML-100A Only)
HOME AUTOMATION
2 Single flash
1. Beep___Beep___
Beep___Beep___
............
Note:
- Try to mount the sensors as far away from the floor as possible to avoid
damaging them. Mounting the sensors at a higher position will also result in
better operating range.
- Do not mount the sensor to the exterior of the door / window, always mount the
sensor to the interior side of the door / window to avoid being damaged or
stolen by non-intended users.
Installing Motion Sensor
The motion sensor is most suitable for guarding a large area such as living room,
family room, or bedroom. It can also be used to monitor a hallway or stairway.
Insert Battery
Undo the screw on the back of the motion sensor and
remove the battery cover. Connect a 9V alkaline battery
to the battery connector. Please note the polarity.
If you are planning to install the motion sensor outdoor,
you should reduce the sensitivity by placing the jumper
at location “2”.
For indoor application, if you want to reduce the
sensitivity, you can change the jumper setting to
“2” as well.
Sensitivity
Part 1 Learn signal from Control Module to Control Panel
StepKeysFunctionDescriptionNote
1
2
3
4
ZONE LEDDESCRIPTION
OffZone is not occupied by any control module
Flashes onceThis zone is occupied by another control module. Programming
Flashes twiceThis zone is occupied by a remote. You can still program a control
[PROG]
[MPIN]
[4]
[1] to [5]
Activate the
control module
by pressing its
learn button
once quickly.
Enter Programming mode
Select learn
control module
programming
Select control
module location
(Max. 5 control
modules)
Send signal
from control
module to
control panel.
another remote to this zone will overwrite the previous control
module.
module to this zone, and it will not overwrite the remote you have
in this zone.
Enter master
password to
programming
mode
Select the
location [1], [2],
[3], [4], or [5].
Once the signal
is transmitted to
the Control Panel,
that signal will be
stored.
3 beeps for valid
password. 1 long beep
for invalid password.
After [4] is entered, some
zone LEDs will flash or
stay off. The zone LEDs
represent whether that
zone is already occupied
by another control
module.**See Table E.
After you have selected
the control module location,
that zone LED will be on.
You will hear
[Device X Accepted],
where “X” is the control
module location.
Jumper Location 1High Sensitivity
Jumper Location 2Low Sensitivity
Caution:
Depending on the environment, if you experience a false trigger when the motion
sensor is placed outdoors, you should relocate it or even place it indoors. Wind
blowing at a tree, or direct sunshine could cause a false trigger. Therefore, if the
location at where the motion sensor is mounted could cause a false trigger, you
should change the mounting location for such sensor.
–16––41–
Flashes once,This zone is occupied by a remote AND a control module. If you
then twiceprogram another control module to this zone, it will overwrite the
previous control module, but not the remote.
** Table E: Zone LED status for learning control module.
HOME AUTOMATION
)
1
1
6
2
2
7
3
3
8
4
4
9
5
5
0
ARM
STATUS
MUTE
PWR
ARM
PROG
LO
BATT
INSTALLATION (ML-100A Only)
The Control Panel can be used to control lights and home applicances with a
Control Module, (Control Module is sold separately). Garage door opener can be
controlled with a Garage Door Receiver (sold separately). The Control Panel can
control up to 5 Control Modules / Garage Door Receivers.
There are 3 ways to control these modules / receivers:
1. Using the keypad on the control panel to
operate these modules / receivers manually
2. Calling in away from home using a touch tone
phone (Refer to “Remote Operation by Telephone”)
Door open
3. Setting up Event Trigger
Lights
on
(Refer to Advanced Programming)
These control modules should be programmed to the control panel as device
1 to 5. Please follow the programming instructions below to program these
control modules.
For outdoor monitoring, please refer to page 33 to program the motion sensor
to Alert Zone.
You may now close the battery cover and
re-insert the screw.
Mount the ball-head joint on the wall with
screws provided. Slide the back of the
sensor into the ball-head joint. The
mounting angle can be adjusted.
Testing
Walk test should be performed after the motion sensor is
mounted. Walk in the detected area, if motion is detected, a
red light inside the sensor will glow. If the red light does not
glow, motion has not been detected and you may need to
re-position the sensor. Ensure you walk test all the locations
that you would like the motion sensor to cover.
Note:
- Perform the walk test after you have inserted the
battery for more than 1 minute.
- Before performing the walk test, the sensor should
not detect any motion.
- After motion is detected once, the sensor will not
be triggered unless no motion is detected for 20
seconds. Therefore, wait for at least 20 seconds
during walk testing between 2 activations.
DETECTING AREA: (Unit = meter
14
12
10
8
6
4
2
M
SENSOR
012345678910111213
1.2M
55°
12°
55°
11°
27°
22°
22°
Learn Control Modules
Both control panel and control module are transceivers, meaning they can transmit
and receive signals from each other. For home automation, the user will initiate an
action from the control panel, such as sending a signal to turn on the light, then the
control module will receive such signal and respond. The control module will then
send back a confirmation to the control panel
to indicate the light has been turned on.
Therefore, during programming,
it is required to program 2 things:
1. Signal from control module to
control panel (confirmation signal)
2. Signal from control panel to
control module (command signal)
Control
Panel
®
LOBATT
Turn on
(command
signal)
Confirm on
(confirmation
signal)
–40–
Control
Module
Caution:
When installing the motion sensor, avoid placing it near heat or cold producing
devices (i.e. A/C or furnace vents, fans, ovens, space heaters, etc). Air movement,
especially caused by changes in temperature may trigger the Motion Sensor and
cause false alarms. Please carefully test your Motion Sensor so that it will only be
triggered by wanted movement.
You have now successfully installed and programmed the Control Panel and its
sensors. Please follow the rest of the instructions for operations and advanced
programming.
–17–
OPERATION
The Control Panel is always in one of the 2 operating modes:
1. Alert Mode - When the system is not armed (ARM LED off), it is in alert mode.
2. Alarm Mode - When the system is armed (ARM LED on), it is in alarm mode.
Alert Mode
The Control Panel will be in alert mode automatically if the system is not armed.
Alert mode allows users inside the premises to know what sensor is triggered.
It is intended to be used when someone stays inside the premises.
In alert mode, the control panel will give you notification of the triggered sensor(s)
by voice announcement, unique beeping and LED flashing.
1Number of beepsZone of the triggered sensor
2Number of flashes of zone LEDSensor number of the triggered sensor
Note:
- Each zone can program up to 2 sensors. There are 5 zones, so up to 10 sensors
can be programmed to the control panel. Please refer to page 37, "Sensor
Location Selection Guide" for detail information.
Alert Mode Examples (Door/Window sensor sold separately)
Zone 1 Sensor 1
Zone 3 Sensor 2 window
open
1.
Beep___Beep___
Beep___Beep .....
1.
Beep Beep Beep___
Beep Beep Beep___
2. Single flash
2. Double flash
ADVANCED PROGRAMMING
SENSOR 1
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Button [1]
Button [2]
Button [3]
Button [4]
Button [5]
Erase Sensors
Proceed to the following to erase a sensor.
StepKeysFunctionDescriptionNote
1
2
3
SENSOR 2
Button [6]
Button [7]
Button [8]
Button [9]
Button [0]
[PROG]
[MPIN]
[9]
To erase an
occupied
sensor, press
[1] to [0].
Enter
Programming
mode
Select erase
remote
programming
Select the
sensor you
would like to
erase
Enter master
password to
programming mode
Refer to the table
below to select the
remote location.
3 beeps for valid password.
1 long beep for invalid
password.
After [9] is entered, some
zone LEDs will flash or
stay off. The zone LEDs
represent whether that zone
is occupied by any sensor.
**See Table D below.
After you have selected the
sensor, you will hear 3 beeps
and verbal confirmation
[Zone X Sensor Y EmptyMemory], where X and Y
are the zone and sensor
numbers you have selected.
This row :
Buttons for
Sensor 1
Zone LED :
Flash once
This row :
Buttons for
Sensor 2
Zone LED :
Flash twice
Note:
-For Door / Window sensor, alert notification (beeping and LED flashing) will
continue until the sensor is in closed position, i.e. closing the window or door.
-For motion sensor, the alert notification was disabled at the factory default. To
perform the walk test, it requires to enable the Alert Zone (Bypass Zone) feature
in the Control Panel. After the walk test, it needs to disable this alert zone feature
otherwise it will bypass the signal in the alarm mode. Please refer to the page 33,
"Alert Zone" for detail. Please refer to information.
–18–
ZONE LEDDESCRIPTION
O ffZone is not occupied by any sensor
Flashes onceThis zone is occupied by sensor 1.
Flashes twiceThis zone is occupied by sensor 2.
Flashes once,This zone is occupied by sensors 1 and 2.
then twice
** Table D: Zone LED status for erasing sensors.
–39–
ADVANCED PROGRAMMING
OPERATION
SENSOR 1SENSOR 2
zone 1Beep / AlarmY / NDisabled / On / OffY / N
Location
zone 2Beep / AlarmY / NDisabled / On / OffY / N
zone 3Beep / AlarmY / NDisabled / On / OffY / N
zone 4Beep / AlarmY / NDisabled / On / OffY / N
zone 5Beep / AlarmY / NDisabled / On / OffY / N
Location
Beep / AlarmAuto Mute
ZONE DEPENDENT FEATURES
Event Trigger
Alert
Table C
4. Once you have filled out the table, it should look something like this.
SENSOR 1
zone 1Beep / AlarmY / NDisabled / On / OffY / N
zone 2Beep / AlarmY / NDisabled / On / OffY / N
zone 3Beep / AlarmY / NDisabled / On / OffY / N
zone 4Beep / AlarmY / NDisabled / On / OffY / N
zone 5Beep / AlarmY / NDisabled / On / OffY / N
Location
Kitchen Motion
Back Door
Backyard Motion
Basement Water
SENSOR 2
Location
Front WindowFront Door
Basement Motion
Beep / Alarm
ZONE DEPENDENT FEATURES
Auto Mute
Event Trigger
Alert
You may refer to each column representing the zone dependent feature, to program
each zone with the selected feature. For example, Auto Mute feature is only enabled
for zone 3, when you are in the auto mute programming, you should enable this
feature for zone 3 only, the rest of the zones should have this feature disabled.
Repeat this step for all 4 zone dependent features during programming.
5. You may now follow the procedure below "Learn Sensor Continue" to program
the sensor(s) to the desired zone(s).
Learn Sensors - Continue
StepKeysFunctionDescriptionNote
1
[PROG]
[MPIN]
2
[3]
Enter Programming mode
Select learn
sensor
Enter master
password to
programming mode
programming
3 beeps for valid
password. 1 long beep
for invalid password.
After [3] is entered, some
zone LEDs will flash
once, or twice, some will
be off. The zone LEDs
represent whether that
zone is already occupied
by another sensor.
**See Table D next page.
3
[0] to [9]
Select sensor
location
Refer to the diagram
below to select the
sensor location, which
After you have
selected the zone, that
zone LED will be on.
includes the zone and
sensor number.
4
Activate the
sensor you
would like to
program to
this zone.
Trigger sensor
Once the sensor is
activated, the signal
will be transmitted
to the Control Panel
which will be stored.
You will hear [Zone X
Sensor Y Accepted],
where X and Y are the
zone and sensor numbers
you have selected.
–38–
Mute
When the alert beeping becomes undesired, you can terminate the beeping in 3
different ways:
1. Mute button - Manual mute by pressing the
mute button
Pressing the mute button will temporary
disable the beeping for all the activated
sensors. For example, if a window with a
window sensor will be open for a long period
of time, the continuous beeping may become
undesired. Pressing the mute button will
temporary disable the beeping for this
sensor only, it will still beep if other sensors
Mute Button
are triggered. This sensor will beep again
if this window is closed, and then opened.
Buzzer Mode Selector
2. Change the buzzer mode - Disable Beeping
The beeping can be disabled for all
zones by changing the buzzer mode
selector.
- If the buzzer mode selector is at "
- If the buzzer mode selector is at "
II
I", beeping is enabled.
II
IIII
II", beeping is disabled.
IIII
If beeping is disabled, all sensor alert beeping will be disabled, however, the
voice announcement and LED flashing will still function.
3. Enable Auto-Mute in Advanced Programming
If this feature is enabled for that zone, beeping will be terminated automatically
after 15 seconds . Refer to "Advanced Programming" - Auto Mute" on page 32
for more information on how to enable this feature.
–19–
OPERATION
ADVANCED PROGRAMMING
System Status
The control panel continuously monitors the system status as well as all the
sensors status. It will monitor occurrences such as triggered sensors, low
battery sensors, malfunction sensors, or phone line failure etc.
In order to check the system status, user can press the “Status” button on the
control panel, voice announcement will be made regarding the system and
sensor status. When the “Status” button is pressed, you will be notified if any of
the following events is occurring:
- System armed or disarmed
- Any triggered sensors
- Any sensors with low battery warning
- Any sensors with failure warning
- Phone line failure
Refer to page 23 for more details regarding system failures.
Arming the System
You should arm the system when you are the last person to leave the house. By
arming the system, the control panel will call the preprogrammed emergency
phone numbers and the siren will sound when break-in occurs.
Caution: Only arm the system when nobody is expected to be inside the premises.
When someone is expected to be within the premises, the system should not be
armed.
To arm the system, follow the procedures below:
45 seconds later
ARM LED on.
System
Armed
OR
Exit delay 45 seconds
Beep Beep
Learn Sensors
You can program up to 10 sensors to the control panel. There are 5 zones on
the control panel, each zone can program up to 2 sensors. Before programming a sensor, you must decide which sensor location (zone number and
sensor number) you would like to program the sensor to. It is strongly recommended that you refer to “Sensor Location Selection Guide” before deciding
which sensor location you would like to program the new sensors to. Some
features you may need to consider are: 1) Beep/Alarm setting, 2) auto mute, 3)
alert zone , 4) event trigger. Explanation for each feature can be found in the
following pages in Advanced Programming:
1. Beep/Alarm Setting - Page 29
2. Auto Mute - Page 32
3. Alert Zone - Page 33
4. Event Trigger - Page 45
Sensor Location Selection Guide
You can program up to 10 sensors to the control panel. There are 5 zones and
maximum 2 sesnors per zone. The 4 features mentioned above are Zone
dependent features meaning both sensors in that zone will operate based on
the setting for that zone. So if you program 2 sensors into one zone, those 2
sensors will react in the same manner for those zone dependent features. For
example, if you enable the Auto-Mute feature for zone 1, both zone 1 sensor 1,
and zone 1 sensor 2 will have this feature enabled. It is not possible to enable a
zone dependent feature for sensor 1 only, but not sensor 2.
Therefore, the followings are some suggestions of how you should select the
sensor location.
1. Check all the zone dependent features, and determine if you would like to
enable any one of them.
2. If you decide not to enable any zone dependent features and keep the
factory default setting, you can simply program the sensor to any sensor
location based on your own preference. Omit the following steps and
proceed to "Learn Sensor - Continue".
1. Press [Arm] on the control
panel or keychain remote.
1. Press [Arm] button on the control panel when no sensors are triggered.
You can also use the keychain remote to arm the system by pressing arm
button on the remote.
2. Leave the premises
within 45 seconds.
3. After 45 seconds.
System will be armed.
–20––37–
3. If you decide to enable some of the zone dependent features, check Table C
below. Circle the zone dependent feature selections. If there are features
that you would like to enable for more than 2 sensors, you need to select
more than one zone for those features.
ADVANCED PROGRAMMING
®
ZONE LED
16
27
38
49
50
REMOTE LOCATION
Remote [6] is represented by zone LED 1
OPERATION
Note:
-
The control panel cannot be armed if there are triggered sensors. Make sure
all sensors are in closed position, i.e. (close all doors, windows, no movement
should be detected etc).
-
The control panel can be armed if there are sensors with low battery or failure
warning.
2. After pressing the “ARM” button, the “ARM” LED will flash and you will have 45
seconds to leave the premises, this is called the exit delay. You will hear
beeping during the exit delay interval. The beeping rate will change from slow
to fast, the faster the beep rate, the less time you have left to leave the premises
before the siren sounds.
Erase Keychain / Keypad Remotes
Follow the instructions below to erase keychain or keypad remotes / receivers.
StepKeysFunctionDescriptionNote
1
2
3
ZONE LEDDESCRIPTION
OffZone is not occupied by any remote
Flashes twiceThis zone is occupied by a remote. You may select this zone to
Flashes onceThis zone is occupied by a control module (Optional).
Flashes once,This zone is occupied by a remote AND a control module.
then twiceYou may select this zone to erase the remote.
[PROG]
[MPIN]
[0]
To erase
an occupied
remote, press
[6] to [0].
erase this remote.
THIS IS NOT A REMOTE CONTROL, THEREFORE, SHOULD NOT BE
ERASED. (Refer to page 43 Erase Control Module for more
information)
Enter
Programming
mode
Select erase
remote
programming
Select remote
location you
would like to
erase
** Table B: Zone LED status for erasing keychain/keypad remote(s).
* Please refer to erase control module on page 43.
Enter master
password to programming mode
Select a remote
location [6], [7],
[8], [9] or [0].
3 beeps for valid
password. 1 long beep
for invalid password.
After [0] is entered, some
zone LEDs will flash or stay
off. The zone LEDs
represent whether that zone
is occupied by any remote.
** See Table B below.
After you have selected the
remote location, you will hear 3
beeps and verbal confirmation
[Device X Empty Memory],
where X is the remote location
you have selected.
3. When the exit delay expires, the control panel will announce “System Armed”,
beeping will stop and the ARM LED will be on steadily. This indicates the
system is now armed.
Note:
The control panel can also be armed remotely when nobody is home, with a touch
tone phone. Please refer to “Remote Operation by Telephone” on page 27.
Disarming the system
If a sensor is triggered while the control panel is armed, such as entering a house
with an armed control panel, an entry delay will be triggered. User is allowed to
disarm the control panel during the 30-second entry delay. If the control panel is
not disarmed within 30 seconds, siren will sound immediately and emergency
calls will be made. To disarm the control panel, follow the instructions below.
Entry delay 30 secondsArm LED off
Beep Beep
1. Entering the premises
will trigger the entry
delay.
Arm LED flashes
Beep Beep
OR
2.Enter password within
30 seconds or press the
disarm button on the
System
Disarmed
3. Once the system is
disarmed, the Arm
LED will be off.
keychain remote.
1. During the entry delay, the system will beep for 30 seconds, the ARM LED will
flash during this entry delay interval. The faster the beep, the less time you
have left to disarm the control panel before the siren sounds.
–21––36–
OPERATION
ADVANCED PROGRAMMING
2. You must enter a valid password, either the Master Password, or Secondary
Password to disarm the system before entry delay expires.
3. When a valid password is entered, you will hear “System Disarmed” and the
entry delay beeping will stop, the ARM LED will be off.
Note:
- The control panel can also be disarmed remotely when nobody is home, with a
touch tone phone. Please refer to “Remote Operation by Telephone” on page 27.
- If 3 consecutive incorrect passwords are entered, alarm will sound immediately,
the control panel will be in panic mode, and start calling the emergency phone
numbers.
Disarming a triggered control panel
If "System Panic" is announced from the control panel after it has been disarmed,
that means the alarm was triggered when it was in armed mode. Follow the
procedures below to set the control panel back to standby mode.
1. If the alarm was caused by sensor(s), there will be flashing LEDs and
beeping indicating which sensor(s) triggered the alarm. You may want to
check the condition of the triggered sensor(s), the sensor(s) may be damaged
if there were break-ins.
2. You need to reset the sensor manually by triggering it twice, i.e. open and
then close a door / window sensor, or walk in front of the motion sensor. The
LED representing that sensor will stop flashing after it receives the signal
from the sensor.
3. You must now enter the password again on the control panel or press the
disarm button on the keychain remote, as an acknowledgement of the alarm
event. This will set the control panel back to standby mode.
Learn Keychain / Keypad Remotes
Additional keychain or keypad remotes can be programmed to the control panel.
Maximum of 5 keychain/keypad remotes can be programmed to the control panel.
- Keychain or keypad remotes should be programmed to Device 6 to Device 0.
Follow the instructions below to program remote(s) to remote location(s) 6, 7, 8,
9, or 0, which is the bottom row of the numeric keypad of the control panel.
StepKeysFunctionDescriptionNote
1
2
3
4
ZONE LEDDESCRIPTION
OffZone is not occupied by any remote
[PROG]
[MPIN]
[4]
[6] to [0]
Activate the
remote by
pressing any
one of the
buttons.
Enter Programming mode
Select learn
remote
programming
Select remote
location
(Max. 5 remotes)
Trigger remote
Enter master
password to
programming mode
Select a remote
location [6], [7],
[8], [9] or [0].
Once the signal is
transmitted to the
Control Panel, that
signal which will
be stored.
3 beeps for valid
password. 1 long beep
for invalid password.
After [4] is entered, some
zone LEDs will flash or
stay off. The zone LEDs
represent whether that
zone is already occupied
by another remote.
** See Table A below.
After you have selected
the remote location, that
zone LED will be on.
You will hear
[Device X Accepted],
where “X” is the remote
location.
Disarming under Duress
If you are forcibly compelled to disarm the control panel, you may enter the Duress
Password. Entering the duress password will terminate the entry delay, i.e. no
more entry delay beeping. But the control panel will silently call the emergency
phone numbers for help. The called party will hear the voice announcement
“System Panic”.
Note:
- The default duress password is [3838].
–22––35–
Flashes twiceThis zone is occupied by another remote. Programming another
remote to this zone will overwrite the previous remote.
Flashes onceThis zone is occupied by a control module* (Optional).
You can still program a remote to this zone, and it will not overwrite
the control module* you have in this zone. (Refer to page 40 Home
Automation for more information)
Flashes once,This zone is occupied by a remote AND a control module*.
then twiceIf you program another remote to this zone, it will overwrite the
previous remote, but not the control module*.
** Table A: Zone LED status for learning keychain/keypad remote(s).
* Please refer to learn control module on page 40.
ADVANCED PROGRAMMING
®
OPERATION
To enable alert zone feature, follow the instructions below.
StepKeysFunctionDescriptionNote
1
2
3
4
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
[PROG]
[MPIN]
[8]
Disable
Alert Zone:
[1] to [5]
Enable
Alert Zone:
[6] to [0].
[PROG]
when
finished.
DISABLE
ALERT ZONE
Button [1]
Button [2]
Button [3]
Button [4]
Button [5]
Enter Programming mode
Select Alert
Zone.
Select which
zone you
would like to
select as Alert
Zone.
Terminate
programming
mode.
ENABLE
ALERT ZONE
Button [6]
Button [7]
Button [8]
Button [9]
Button [0]
Enter master
password to
programming mode
Refer to the
diagram below to
select the
appropriate
setting.
3 beeps for valid
password. 1 long beep
for invalid password.
After [8] is entered,
some zone LEDs will
flash or stay on. This
indicates whether alert
zone is selected.
If alert zone is selected,
that zone LED will be on.
If it is not selected, the
LED will flash. You are
allow to make multiple
changes before terminating programming mode.
PROG LED will be
off.
This row :
Buttons to
Disable Alert Zone
Zone LED : Flash
This row :
Buttons to
Enable Alert Zone
Zone LED : ON
Panic
Pressing the panic button on the control
panel or keychain remote will cause the
siren to sound and outgoing calls will
be made to the preprogrammed phone
numbers, “System Panic” will also be
announced. This can be used in any
emergency situation.
To stop the siren and disarm the system, user can enter a valid password, or
press the disarm button on the keychain remote. This will terminate the siren
and the control panel from calling the rest of the emergency phone numbers.
PANIC
AUX
- Control other Skylink receiver
such as Garage Door Receiver
ARM
DISARM
OR
System Failure
Control Panel constantly monitors itself and its sensors. If there are any trouble
conditions, the control panel will advise the user. These trouble conditions include:
- Phone Line Failure
- Sensor Failure (loss of supervisory signal)
- Low Battery – Control Panel
- Low Battery – Sensors
Phone Line Failure
When the phone line is disconnected or malfunctions, the control panel will
instantly notify the user by:
1. Both Power [PWR] and Program [PROG] LEDs will flash together;
2. Voice announcement “Phone Line Failure” will be played.
When phone line failure occurs, please check the phone line connection, ensure
the phone line is plugged into both the control panel and the wall socket securely.
You should also check the phone line with a normal telephone to determine if it
can dial out to a phone number. If it cannot dial out, that indicates the phone line
is not in service, you should contact your local phone company.
–34–
–23–
Sensor Failure
OPERATION
ADVANCED PROGRAMMING
The control panel constantly monitors its sensors, if the control panel fails to
communicate with any sensors, it will notify the user by:
1. The zone LED of the failed sensor will be on steadily;
2. Voice announcement “zone X sensor Y failure” will be played.
When sensor failure occurs, try the following:
1. Check if the sensor is located at where it should be, and whether there is any
physical damage to the sensor.
2. If the failed sensor is not physically damaged, try to activate the sensor and see
if the control panel reacts to such activation.
3. If not, try to remove the sensor from its location, and bring it closer to control
panel and activate the sensor. It is possible that the sensor is installed too far
from the control panel and it cannot establish a steady communication with the
control panel. If this is the case, please install the sensor closer to the control
panel.
Low Battery
Control Panel
The control panel is powered mainly by the adapter. However, during power outage,
it will be powered by the rechargeable backup battery. Under standby conditions,
these batteries can last for 48 hours.
ENABLE
AUTO MUTE
Button [6]
Button [7]
Button [8]
Button [9]
Button [0]
This row :
Buttons to
Disable Auto Mute
Zone LED : Flash
This row :
Buttons to
Enable Auto Mute
Zone LED : ON
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
DISABLE
AUTO MUTE
Button [1]
Button [2]
Button [3]
Button [4]
Button [5]
Alert Zone (Bypass Zone)
As explained earlier, the control panel can operate in 2 different modes, 1) Alert
Mode, 2) Alarm Mode. In alarm mode, when a sensor is triggered, the control
panel will either give a 30 seconds entry delay, or siren will sound immediately
(with instant alarm). However, there are sensors that you do not want to trigger
the alarm when the system is armed. Such as an outdoor sensor, or any other
sensors that you only want to give you alert notification. Under such circumstances, zone(s) can be programed to react only when the control panel is in
alert mode, these zones will be automatically bypassed when the control panel
is in alarm mode. These zones can also be considered as "Bypass zones".
It is recommend to enable alert zone if:
When the backup battery is running low, the “LO BATT” LED on the control panel
will be on, indicating the backup battery should be recharged. To recharge the
backup battery, plug in the power adapter. It takes approx. 20 hours to fully charge
the backup battery.
Sensors (For ML-100A Only)
All of the sensors are battery powered. Depending on the operating condition
and environment, the battery life varies from 9 months to 2 years. 9V alkaline
battery is used for the motion sensor, the battery life is approximately 9 months.
Door / Window Sensor operates on a Lithium CR-2032 battery, with battery life of
approximately 2 years. For other sensors, please refer to the user’s instructions
regarding the battery life.
–24––33–
- You do not consider the sensors in that zone an emergency
- Sensors in that zone are located outdoors
- When nobody is at home, you do not want to know the status of the sensor(s) in
that zone
Factory Default: This feature was disabled for all zones at the factory.
ADVANCED PROGRAMMING
OPERATION
Auto Mute
When a sensor is triggered in alert mode, audio warning will be emitted, either
beep or alarm. For example, if a door is opened, the beep will not stop until the
door is closed. If the door is open for 2 hours, the beep will go on for 2 hours.
There are times that this is not desired. With the auto mute feature enabled, the
beep will go on for only 20 seconds. After that, even if the sensor remains open,
the beep will stop only the zone LED will flash to indicate the sensor is triggered.
Beep will go on again if the sensor is closed and opened again.
Note: Auto Mute only functions when the control panel is in alert mode (disarmed).
If the control panel is in alarm mode (armed), a triggered sensor will result in
entry delay or instant alarm.
Factory Default: This feature was disabled for all zones at the factory.
To enable auto mute feature, follow the instructions below.
StepKeysFunctionDescriptionNote
1
2
[PROG]
[MPIN]
[6]
Enter Programming mode
Select Auto Mute
Enable / Disable
Enter master
password to
programming mode
3 beeps for valid
password. 1 long beep
for invalid password.
After [6] is entered, some
zone LEDs will flash or
stay on. This indicates
whether Auto Mute is
enabled or disabled.
When the sensor is running low in battery, the sensor will send a wireless low
battery signal to the control panel. The zone LED representing that sensor will be
on steadily, indicating sensor(s) in that zone is in trouble condition. Control Panel
will also have an announcement to advise the user the trouble condition is low
battery, such as “zone X sensor Y low battery”, where X and Y represent the zone
and sensor number. Please replace the battery of that sensor.
Keychain Remote (For ML-100A Only)
The battery of the keychain remote (Alkaline, Type 23A, 12V)
needs to be replaced
when either one of the followings occurs:
1. The LED on the keychain doesn’t flash or on when a key is pressed; or
2. The operating range starts to decrease.
To replace the battery:
1. Undo the two screws on the back of the transmitter.
The bottom case will then come off.
2. Using a small screwdriver or pen, pry out the old
battery from one end.
3. Place the new battery in position. A diagram in the
battery compartment indicates which end is positive
and which is negative.
4. Close the battery cover and reinsert two screws.
-
3
4
Disable
Auto Mute:
[1] to [5]
Enable
Auto Mute:
[6] to [0].
[PROG]
when
finished.
Select which
zone you would
like to enable /
disable auto mute.
Terminate
programming
mode.
Refer to the diagram
below to select the
appropriate setting.
–32–
If auto mute is enabled,
that zone LED will be on.
If it is disabled, the LED
will flash. You are allow
to make multiple changes
before terminating
programming mode.
PROG LED will be off, and
you will hear 3 beeps.
+
–25–
COMMUNICATION
®
ADVANCED PROGRAMMING
Receiving the Emergency Call
If you are on the list as one of the recipients of the emergency call, you should read
the following instructions carefully. You should also notify all the persons you will
be calling so they know how to react when they receive the emergency call.
The control panel will call you when there are emergencies such as break-ins,
smoke, fire events, or someone at home needs assistance.
1. When the phone rings at the calling location, the person who answers the
phone will hear a message related to the emergency events, such as
“System Panic”, or “Zone 1 Sensor 1 Triggered” etc. This message may be
repeated several times depending on how it was programmed.
2. After the message has been repeated for
a certain number of times, the control panel
will ask for a valid password, you will hear
“Enter Password”.
Zone 1
Sensor 1
3. Enter the 4-digit password to have access
to the control panel. If a valid password is
accepted, you will hear “Password Accepted”,
otherwise, you will hear “Password Failure”.
4. After entering the correct password, you
can follow the “Phone Command” instructions to perform the required tasks, such
as disarm, turn on / off devices or check the
system status etc. For further information
of how to control the system remotely,
please refer to the next section, "Remote
Operation by Telephone".
Triggered
Enter
Password
-Arm
-Disarm
-Check status
-Control lighting etc.
-Disconnect
Follow the procedures below to program the beep / alarm setting.
StepKeysFunctionDescriptionNote
1
[PROG]
[MPIN]
Enter Programming
mode
Enter master
password to
programming mode
2
[5]
Select Beep /
Alarm Setting
3 beeps for valid password.
1 long beep for invalid
password.
After [5] is entered, some zone
LEDs will flash or stay on.
This indicates whether that
zone is set to beep or alarm.
3
Set to Beep:
[1] to [5]
Select which
zone you would
like to Beep or
Set to Alarm:
Alarm.
[6] to [0].
Refer to the
diagram below to
select the appropriate setting.
If Alarm is set for that zone,
that zone LED will be on. If
Beep is set, the LED will
flash. You are allowed to
make multiple changes before
terminating programming
mode.
4
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
[PROG] when
finished.
BEEP
Button [1]
Button [2]
Button [3]
Button [4]
Button [5]
Terminate programming mode.
ALARM
Button [6]
Button [7]
Button [8]
Button [9]
Button [0]
PROG LED will be off, and
you will hear 3 beeps.
This row :
Buttons for Beep
Zone LED : Flash
This row :
Buttons for Alarm
Zone LED : ON
Example:
If you would like to change the setting for zone 5 from “Beep” to “Alarm”, simply
press [0] at step 3.
This will change the zone 5 setting to “Alarm”.
–26–
–31–
ADVANCED PROGRAMMING
COMMUNICATION
System Armed (Alarm Mode)
If a zone is set to “Beep”, the control panel will give entry / exit delay.
If a zone is set to “Alarm”, the siren will sound immediately without entry delay
- Alarm Mode (System Armed): If a sensor is triggered (i.e. opening a door) with
the alarm setting on, the siren will sound immediately without entry delay, it is
called “Instant Alarm”. The siren will not stop until the siren timeout or a valid
password is entered. Control panel will call the emergency phone numbers to
notify the users of the alarm situation.
Armed (Alarm)3) Entry / Exit Delay4) Alarm sounds and calls
preprogrammed phone
numbers immediately
Factory Default: All zones were programmed to Beep at the factory.
You may consider to programming the zone(s) into Alarm mode if:
Remote Operation by Telephone
The control panel can be operated while you are away from home. You can
have access to the control panel with any touch tone phone to perform a variety
of operations, listed below.
- Arm
- Disarm
- Lights, Home Applicances on / off (Requires additonal Control Module)
- Garage door open / close (Requires additional Garage Door Receiver)
- System status
- Disconnect
There are 2 ways you can have access to the remote phone operation:
1. You can call the control panel when you are away from home; or
2. When the control panel calls you during emergency.
To access the control panel away from home
Calling in when you are away from home
1. Call your home phone number, or the number that the phone line of the control
panel is connected to.
- You need immediate attention if that sensor is triggered, such as flood sensor,
smoke sensor etc.
- The sensor will not be triggered on a daily basis, such as a door that you
normally will not open, and if it opens, you would like to know immediately.
Caution:
It is not recommended to program an outdoor sensor to Alarm mode, which may cause
false alarm. For outdoor sensors, they should be programmed into an Alert Zone,
please refer to page 33 for details.
–30–
2. Hang up after the second ring.
3. Wait at least 10 seconds, but not more than 40 seconds, then call the phone
number again.
4. The control panel will pick up the phone call and request for a valid user
password, you will hear “Enter Password”. You can enter either the Master
Password or Secondary Password. If the password is correct, you will hear
“Password Accepted”, otherwise, you will hear “Password Failure”.
5. Once the password is accepted, you can have access to all the operations
listed below.
–27–
COMMUNICATION
ADVANCED PROGRAMMING
Table 1: Remote Phone Operations
SYSTEM OPERATION
Turn on device x
[x] = 1 to 5
Turn off device x
x = [1 to 5]
Check system status
Arm
Disarm
Disconnect
PHONE COMMAND
x+[*]
x+[#]
[8]+[#]
[7]+[#]
[9]+[#]
[0]+[#]
Turn devices on will hear [Device X On]. When the
control module receives the on signal, it will turn on the
plugged in device, and send a confirmation back to the
control panel. You will then hear [Device On Accepted].
Turn devices off will hear [Device X Off]. When the
control module receives the off signal, it will turn off the
plugged in device, and send a confirmation back to the
control panel. You will then hear [Device Off Accepted].
You will hear system status announcement
You will hear [System Armed]
You will hear [System Disarmed]
Phone line disconnect
DESCRIPTION
Advanced Programming allows users to customize the control panel to react
differently under different conditions. Features such as:
- When a sensor is triggered, the control panel can beep or alarm
- Beeping can be terminated automatically after a fixed period of time for some sensors
- Some sensors can be programmed to beep only, never alarm
- When a door is open, turn lights on
- Program additional sensors and remotes
Programming Summary
COMMANDDESCRIPTION
[PROG] + [1]Program Phone Numbers
[PROG] + [2]Program Password
[PROG] + [3]Learn Sensors
[PROG] + [4]Learn Keychain or Keypad Transmitters / Control Modules
[PROG] + [5]Beep / Alarm Setting
[PROG] + [6]Auto Mute Setting
[PROG] + [7]Event Trigger Setting
[PROG] + [8]Alert Zone (Bypass) Setting
[PROG] + [9]Erase Sensors
[PROG] + [0]Erase Keychain or Keypad Transmitters / Control Modules
Follow the instructions below to have access to Advanced Programming.
Beep / Alarm
User can customize the audio warning so that when a sensor is triggered, the
control panel may beep or alarm may sound instantly. Depending on whether the
control panel is armed or disarmed, the audio warning is different.
System Disarmed (Alert Mode)
If a zone is set to “Beep”, the control panel will beep when a sensor is triggered,
until the sensor is deactivated. Motion Sensor activation will not cause any
beeping unless the zone for the motion sensor is programmed as a "Bypass
Zone" (see page 33).
If a zone is set to “Alarm”, alarm will sound instantly when a sensor is triggered.
Alarm will stop when the sensor is deactivated, or reaches a 3-minute time out period.
–29––28–
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.