
ME/W-SG
Signal Generator for the ME-Systems and the Wireless-System
The ME/W-Signal Generator is a very convenient tool for users of the Wireless-System and / or for users
of ME-Systems. Use the ME/W-SG instead of setting up a complete experiment for training, controlling,
and troubleshooting purposes.
10-pin single row connector
for W4 and W8 (single row)
and MPA8I headstages.
Battery
40-pin Omnetic connector
Dip Switch
for W32 headstage and
for μPA32 preamplifier.
W8
MPA8I
Control Button
20-pin Omnetic connector
for W8 and W16 headstages
and for μPA16 preamplifier.
Connect the W8-headstage (single row connector) of the Wireless-System
to the 10-pin single row precision connector. The W4-headstage needs
an adapter to fit into the single row connector. Connect the μPA3 2
of the ME-System and the W32 headstage of the Wireless-System to
the 40-pin Omnetic connector. Connect the μPA16 of the ME-System
and the W16 and the W8 (with Omnetic connector) of the WirelessSystem to the 20-pin Omnetic connector.
Connect the wireless headstages W8 and W16 according to the guide posts
as shown on the photos beside. The orientation of the W32 does not matter.
Additionally it is possible to connect the MPA8I-System to the ME/W-SG.
Please insert the MPA8I headstage together with the adapter in correct
orientation into the 10-pin single row connector as shown on the photo
below. The MPA8I headstage is equipped with an 11-pin connector,
that is why one of the pins is not connected. The bottom of the MPA8I
headstage (black side) must show to the bottom of the signal generator.
The free pin of the 11-pin connector must be on the right side.
MPA8I headstage connected to the ME/W-SG
Please connect the MPA8I headstage with
the provided 10-pin double row adapter
in correct orientation to the ME/W-SG.
W16
W4
Multi Channel Systems
MCS GmbH
Aspenhaustrasse 21
72770 Reutlingen
Germany
W4 headstage connected to the ME/W-SG
Please connect the W4 headstage with
the provided 6-pin double row adapter
in correct orientation to the ME/W-SG.
Fon +49-7121-9 09 25Fax
+49-7121-9 09 25-11
info@multichannelsystems.com
www.multichannelsystems.com
0
© 2014 Multi Channel Systems MCS GmbH
Product information is subject to change
without notice.

ME/W-SG
Signal Generator for the ME-Systems and the Wireless-System
Switch ME/W-SG on: Press the control button. Switch off: Press control button longer than two seconds.
Switch
1
OFF
ON
Switch
2
press
Button
slowly
n times
OFF
(The ME/WSG is ON)
1
2
3
4
5
OFF
Sine Wave
1
(The ME/WSG is ON)
2
Signal Source
Artificial Sine Wave (1.75 mV) 0.005 Hz
Note: sine waves < 1 Hz might not be
visible because of the hardware filter
bandwidth.
Sine Wave
Sine Wave
Sine Wave
Hippocampal Slice
0.01 Hz
0.03 Hz
1.25 Hz
12.5 Hz
EPSP
Hippocampal Slice
Population Spike
Signal Type
OFF
ON
2
ON
Multi Channel Systems
MCS GmbH
Aspenhaustrasse 21
72770 Reutlingen
Germany
1
ON
3 Hippocampal Neurons
Spikes
1
(The ME/WSG is ON)
Heart
ECG Atrium
Heart
ECG Ventricle
3 Cardiomyocytes
Ventricle FP
(The ME/WSG is ON)
Fon +49-7121-9 09 25Fax
info@multichannelsystems.com
www.multichannelsystems.com
+49-7121-9 09 25-11
Retina
ERG with Spike
0
© 2014 Multi Channel Systems MCS GmbH
Product information is subject to change
without notice.