Technical Specifications
perforated MEA (Microelectrode Array) for MEA2100-32- and USB-MEA32-STIM4-System
pMEA for use with
MEA2100-32- and
USB-MEA32-STIM4System
Temperature compatibility
Dimension (W x D x H)
Base material
Perforation:
Total area of perforation
Diameter of the holes
Contact pad
Track material
Electrode diameter
Interelectrode distance
Electrode height
Electrode type
Isolation type
Electrode impedance
Electrode layout grid
Number of electrodes
Ring
pMEA-32S12 Layout 1
49 x 25 mm x 180 μm
Polyimide foil on ceramic
carrier with perforation
0.8 mm
20, 30, 50, 75 and 90 μm
Titanium nitride (TiN)
Titanium (Ti)
30 μm (recording electrode)
50 μm (stimulation electrode)
90 and 150 μm (record. electrode)
100 and 125 μm (stim. electrode)
Planar
Titanium nitride (TiN)
Polyimide foil
30 – 50 k
1x10+1x12+1x10 (record. electr.)
2x6 (stimulation electrodes)
32 recording electrodes
12 stimulation electrodes
1 internal reference electrode
Without ring
Glass ring
2
10 °C – 50 °C
pMEA-32S12 Layout 2
10 °C – 50 °C
49 x 25 mm x 180 μm
Polyimide foil on ceramic
carrier with perforation
2
0.8 mm
20, 30, 50, 75 and 90 μm
Titanium nitride (TiN)
Titanium (Ti)
30 μm (recording electrode)
50 μm (stimulation electrode)
90 and 150 μm (record. electrode)
90 and 150 μm (stim. electrode)
Planar
Titanium nitride (TiN)
Polyimide foil
30 – 50 k
1x10+1x12+1x10 (record. electr.)
2x6 (stimulation electrodes)
32 recording electrodes
12 stimulation electrodes
1 internal reference electrode
Without ring
Glass ring
pMEA-32S12 Layout 3
10 °C – 50 °C
49 x 25 mm x 180 μm
Polyimide foil on ceramic
carrier with perforation
2
0.8 mm
20, 30, 50, 75 and 90 μm
Titanium nitride (TiN)
Titanium (Ti)
30 μm (recording electrode)
50 μm (stimulation electrode)
90 and 150 μm (record. electrode)
90 and 100 μm (stim. electrode)
Planar
Titanium nitride (TiN)
Polyimide foil
30 – 50 k
1x10+1x12+1x10 (record. electr.)
3x4 (stimulation electrodes)
32 recording electrodes
12 stimulation electrodes
1 with internal reference electrode
Without ring
Glass ring
pMEA-32S12 Layout 4
10 °C – 50 °C
49 x 25 mm x 180 μm
Polyimide foil on ceramic
carrier with perforation
0.8 mm
20, 30, 50, 75 and 90 μm
Titanium nitride (TiN)
Titanium (Ti)
30 μm (recording electrode)
50 μm (stimulation electrode)
100 and 100 μm (record. electrode)
100 and 100 μm (stim. electrode)
Planar
Titanium nitride (TiN)
Polyimide foil
30 – 50 k
4x8 (recording electrode)
2x6 (stimulation electrodes)
32 recording electrodes
12 stimulation electrodes
1 internal reference electrode
Without ring
Glass ring
2
© 2013 Multi Channel Systems MCS GmbH