ADPT-NN-8
8-Electrode NeuroNexus Probe
Adapter for MPA8I Amplifier
Connecting the MPA8I to the adapter ADPT-NN-8
Adapter ADPT-NN-8
Setup with probe from NeuroNexus,
adapter ADPT-NN-8 and MPA8I.
Connect MPA8I here
Important: Connect the MPA8I with the black side
Important: Connect the MPA8I with the black side
down. Otherwise, the device does not work.
down. Otherwise, the device does not work.
Channel assignment, output pins (connected to MPA8I)
8-Electrode NN Probe
8-Electrode NN Probe Connector
Adapter ADPT-NN-8
Ground
connector
G
MPA8I
87654321R
G
Back Side
Shown are the output pins of the adapter ADPT-NN-8 that are connected to the miniature
preamplifiers MPA8I when looking from the back directly at the pins. The labeled channels
are the ground channels (G), the reference channel (R), and the 8 recording channels (1 to 8)
of the MPA8I. Please see the MPA8I manual for details.
Warning: The device may only be used together with the MPA8I from Multi Channel Systems
!
MCS GmbH and the 8-channel probe from NeuroNexus, and only for the specified purpose.
Damage of the device and even fatal injuries can result from improper use.
Multi Channel Systems
MCS GmbH
Aspenhaustrasse 21
72770 Reutlingen
Germany
Fon +49-7121-9 09 25Fax
+49-7121-9 09 25-11
info@multichannelsystems.com
www.multichannelsystems.com
0
© 2012 Multi Channel Systems MCS GmbH
Product information is subject to change
without notice.
ADPT-NN-8
8-Electrode NeuroNexus Probe
Adapter for MPA8I Amplifier
Connecting the NeuroNexus Probe to the adapter ADPT-NN-8
Complete setup with NeuroNexus probe, adapter ADPT-NN-8 and MPA8I
NeuroNexus Probe
ADPT-NN-8
MPA8I
Important:
Black side of MPA8I faced down !
MPA8I
Top View without probe
Pin Layout ADPT-NN-8
Pin Layout
MPA8I Out MC_Rack Channels
NeuroNexus Probe
Connector Pin Out
1
2
3
4
5
6
7
8
9
10
11
GND (shielding)
REF (input)
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
Channel 7
Channel 8
GND (power)
CH 4
CH 1
CH 2
CH 3
5 CH
8 CH
7 CH
6 CH
CH 4
CH 1
CH 2
ORO
CH 3
Ground
connector
5 CH
8 CH
7 CH
6 CH
GND
REF
CH 1
CH 2
CH 3
CH 4
CH 5
CH 6
CH 7
CH 8
GND
Front Side
On the left picture the input pins of the adapter ADPT-NN-8 are shown that are connected to the probe.
On the right picture the output pins of the NeuroNexus probe are shown that are connected to the
adapter. In the middle you have the pin layout of the MPA8I: The labeled channels are the ground channel
(GND shielding), the reference channel (REF input), and the 8 recording channels (1 to 8) of the MPA8I.
The ground channel connected to pin 11 of the MPA8I input pins is the power ground (GND power).
Please see the MPA8I manual for details. If you use MC_Rack for data acquisition, see Pin Layout above.
G and R have been connected together as factory-default settings to a 0 Ohm resistor (ORO).
Important: Operation of the MPA8I is differential. The reference channel R has to be used for obtaining
a proper signal. Please see the MPA8I manual for details.
Multi Channel Systems
MCS GmbH
Aspenhaustrasse 21
72770 Reutlingen
Germany
Fon +49-7121-9 09 25Fax
+49-7121-9 09 25-11
info@multichannelsystems.com
www.multichannelsystems.com
0
© 2012 Multi Channel Systems MCS GmbH
Product information is subject to change
without notice.