MTS Systems THIR-6780 Configuration Manual

Page 1
THIR-6780 Series
Configuration Barcode Menu
1dimensional / 2dimensional
Image Reader
12-Sep-28
1st edition
Page 2
1
Update Information】
Edition
Date
Update Contents
1st edition
2012/ 9/28
New release
Page 3
2
Table of Contents
COMMAND MANUAL USAGE NOTES .............................................................................................................. 6
ABBREVIATIONS USED .................................................................................................................................... 6
1. COMMUNICATIONS SETUP .......................................................................................................................... 7
Baud rate .................................................................................................................................................. 7
Character Framing .................................................................................................................................... 8
RS/CS Control .......................................................................................................................................... 9
Header ..................................................................................................................................................... 9
Terminator ...............................................................................................................................................10
2. SYMBOL SETUP ........................................................................................................................................... 11
2.1 COMMON SETUP ............................................................................................................................................. 11
All Symbol Types ..................................................................................................................................... 11
Mirrored Image ........................................................................................................................................ 11
Center Reading Mode ..............................................................................................................................12
Reading Digit Length ................................................................................................................................13
Maximum decodable symbols per trigger input ..........................................................................................14
Multiple symbol separator ............................................................................................................................14
Set the output order for multiple symbol reading ........................................................................................15
Set the sorting method .............................................................................................................................15
Select the output number to be programmed.............................................................................................16
Select the item to be set ...........................................................................................................................16
Add Symbol Information (Add AIM Standard Code) ...................................................................................16
Additional Symbol Information (Optional Data) ..............................................................................................18
Optional Symbol data preceding read data ...............................................................................................18
Setup Optional Symbol Data at Front........................................................................................................18
Setup Add Optional Symbol Data at End ..................................................................................................20
Setup Optional Symbol Data at End .........................................................................................................20
Additional Function of Optional Data for Prefix or Suffix .................................................................................22
Add Prefix Data .......................................................................................................................................22
Setup Prefix Data.....................................................................................................................................22
Start Setup Prefix CharacterAdd Suffix Data .............................................................................................22
Setups Suffix Data ...................................................................................................................................23
Control Character .....................................................................................................................................24
Method of Transmit Control Code .............................................................................................................24
Transmit Control Character [GS] ..............................................................................................................24
Transform optional character from GS Output ...........................................................................................25
Character Code ...........................................................................................................................................26
Character Table .......................................................................................................................................26
Character Data ............................................................................................................................................27
Symbol Type ............................................................................................................................................29
Confirm / Cancel multiple reading setting ...................................................................................................30
2.2. SYMBOL READING SETUP ................................................................................................................................31
Code39 ...................................................................................................................................................31
Page 4
3
Code39 Start / Stop Transmit ....................................................................................................................32
Code128 .................................................................................................................................................32
GS1-128(EAN128) ..................................................................................................................................32
Codabar Setup ........................................................................................................................................33
Codabar ST/SP Character Case...............................................................................................................33
Codabar Start / Stop transmission .............................................................................................................34
ITF Setup.................................................................................................................................................34
ITF Digits Setup .......................................................................................................................................35
Code93 ...................................................................................................................................................35
GS1 Databar(RSS) ..................................................................................................................................35
Setting the Application Identifier ................................................................................................................36
Composite ...............................................................................................................................................36
JAN/EAN/UPC Setup...............................................................................................................................37
JAN/EAN/UPC Standard Check Digit Transmission ...................................................................................37
JAN/EAN Shortened Check Digit Transmission .........................................................................................38
UPC-A Check Digit Transmission..............................................................................................................38
UPC-E Check Digit Transmission .............................................................................................................38
UPC-A Number System transmission .......................................................................................................38
UPC-E Number System Transmission ......................................................................................................39
UPC-E Format Conversion.......................................................................................................................40
UPC Output Digits ....................................................................................................................................40
DataMatrix Setup .....................................................................................................................................41
DataMatrix Cell Size .................................................................................................................................42
Maxi Code Setup .....................................................................................................................................42
Transmission of Primary...........................................................................................................................44
PDF417 ...................................................................................................................................................44
QR Code Setup .......................................................................................................................................45
Customer Barcode(Japan Post Code) ......................................................................................................46
Enable / Disable customer Barcode (Japan Post Code) decoding. .............................................................46
Enable / Disable the reading of incomplete customer barcodes. .................................................................46
Aztec Code ..............................................................................................................................................47
3. OPERATIONAL SETUP .................................................................................................................................48
3.1 GENERAL OPERATIONAL SETUP........................................................................................................................48
Writes Setup Values .................................................................................................................................48
Restore factory default settings .................................................................................................................48
My Settings ..............................................................................................................................................49
Registration of My Setting ........................................................................................................................49
Load registered My Settings .....................................................................................................................49
Buzzer setup ...............................................................................................................................................50
Vibration ......................................................................................................................................................50
Continuous Reading Interval Mode ...........................................................................................................51
Setting for Continuous Reading Interval Mode ..........................................................................................51
Continuous Reading Mode Interval ..............................................................................................................52
Prohibit Same Symbol decoding in Continuous Reading Mode .....................................................................53
Same Symbol prohibition duration in Continuous Reading Mode ...................................................................53
Page 5
4
Autosense Mode......................................................................................................................................54
Enable / Disable autosense mode. ...........................................................................................................54
Autosense Mode timeout .............................................................................................................................55
Decode Time out .........................................................................................................................................56
Pointer in Autosense mode ..........................................................................................................................57
Autosense sensitivity ...................................................................................................................................57
Prohibit Same Symbol decoding in Auto Detection mode. .............................................................................58
Same Symbol Prohibition duration in Auto Detection Mode ...........................................................................58
Cropping Image area ...................................................................................................................................59
Quick Setting with Function Button ...............................................................................................................60
3.2 SETTING CAMERA CONTROL ............................................................................................................................61
AGC ...........................................................................................................................................................61
Illumination ..............................................................................................................................................61
3.3 PRESET MODE SETTING ...................................................................................................................................62
Preset Mode 0 .........................................................................................................................................62
Preset Mode 1 .........................................................................................................................................62
Preset Mode 2 .........................................................................................................................................63
Preset data registration ............................................................................................................................63
Setting for Digits.......................................................................................................................................64
Setting for Verifying Character’s ................................................................................................................64
Example of Preset data ............................................................................................................................65
Transmitting Preset Status ...........................................................................................................................66
4. DIAGNOSIS ...................................................................................................................................................67
Output the Decode Time ..............................................................................................................................67
Output Actual Reading Statistics ...................................................................................................................68
Output Actual Reading Statistics2 .............................................................................................................69
Output of Bar Code Position Information ...................................................................................................70
a)Barycentric coordinates .........................................................................................................................70
b) 4 Corner Coordinate Data ....................................................................................................................70
Reference 4 Coordinate Position of Each Symbol .....................................................................................71
c) Output of Both Geometrical Center and 4 Corner Coordinates ...............................................................72
Setup Output Coordinate .........................................................................................................................72
5. SETTING REFERENCE .................................................................................................................................73
Status1 ....................................................................................................................................................73
Status 2 ...................................................................................................................................................75
Status 3 ...................................................................................................................................................79
Status 4 ...................................................................................................................................................80
Status IMG...............................................................................................................................................83
Image Area Definition ...............................................................................................................................84
Status “LF” ...............................................................................................................................................85
6. SETTING FOR HID TYPE ONLY ....................................................................................................................86
Data Transmission Interval ...........................................................................................................................86
Keyboard Selection .....................................................................................................................................87
Page 6
5
Caps Lock Setting ....................................................................................................................................87
Setting for Uppercase/Lowercase Conversion ...........................................................................................87
HID Status ...............................................................................................................................................89
7. USB DEVICE TYPE .......................................................................................................................................90
Initiate USB interface type switch ..............................................................................................................91
Select interface type.................................................................................................................................91
Save Settings ..........................................................................................................................................91
Page 7
6
Introduction
The configuration barcodes provided in this manual offer instant setup off the various scanner settings, E.G., serial communication baud rate, enabling and disabling barcodes.
Note: Default values in this guide are indicated by the notation “(*)”. Note: Barcodes may also be referred to as “symbols”. This manual may use either or both conventions.
Please read the operation Manual of this reader carefully to ensure correct use of the equipment. Keep the document near the equipment for reference in the event of problems.
The contents of this document are subject to change without notice.
Ensure to scan the “Save Settings” barcode after settings have been changed to write the settings on the scanner’s non-volatile flash memory. Without saving the settings the scanner will revert to the previously stored settings after power is reapplied.
Command manual Usage Notes
Some of the commands listed in this manual can also be set-up by sending commands from a host computer.
Abbreviations used
Check digit ……. C/D. Start stop………. ST/SP.
Page 8
7
1. Communications Setup(serial interface
Baud rate
To set the Baud rate to match the baud rate setting of the host device, scan the appropriate symbol below.
1200[bps] 2400[bps]
4800[bps] 9600[bps](*)
19200[bps] 38400[bps]
57600[bps] 115200[bps]
Page 9
8
Character Framing
To set the combination setting of Data Bits ,Parity and Stop Bits to match those settings of the Host device, scan the appropriate symbol below.
7 bits/Odd/Stop bit 1 7 bits/Odd/Stop bit 2
7 bits/Even/Stop bit 1 7 bits/Even/Stop bit 2
8 bits/None/Stop bit 1 (*) 8 bits/None/Stop bit 2
8 bits/Odd/Stop bit 1 8 bits/Odd/Stop bit 2
8 bits/Even/Stop bit 1 8 bits/Even/Stop bit 2
Save Settings
(Write into Flash ROM)
Page 10
9
RTS/CTS Hardware Handshaking
To Enable or Disable RTS/CTS Hardware Handshaking (RTS/CTS H/H) to the Host device, scan the appropriate symbol below.
Enable RTS/CTS H/H Disable RTS/CTS H/H (*)
Suffix character
A prefix character may be appended to the head of scan data for use in data editing. To set the prefix character, scan the appropriate symbol below.
None (*) [SX]
[EC]
Save Settings
(Write into Flash ROM)
Page 11
10
Suffix character
A suffix character may be appended to the end of scan data for use in data editing. To set the Suffix character, scan the appropriate symbol below.
None [EX]
[EX][CR] [CR][LF] (*)
[CR] [CR][TAB]
[TAB][CR] [TAB]
Save Settings
(Write into Flash ROM)
Page 12
11
2. Symbol Setup
2.1 Common Setup
All Symbologies
To Enable or Disable to decode symbols for all symbolories, scan the appropriate symbol below.
Note: To enable only a select number of symbologies, it is advised to disable all symbologies first and
enable only the symbology type(s) needed.
Enable All Symbologies Disable All Symbologies
Mirrored Image
To Enable or Disable to decode symbols for Mirrored symbols, scan the appropriate symbol below.
Note: 1-dimentional barcodes can be decoded in both mirrored and normal modes.
Read Normal Image (*) Read Mirrored Image
When in “Read Mirrored Image” mode, the barcode menu symbols cannot be read. Use the following symbol to switch the scanner back to “Read Normal Image” mode.
Read Normal Image (*)
Page 13
12
Center Reading Mode
To Enable or Disable to read symbols located at the central part of the field of view only, scan the appropriate symbol below.
Enable Center Reading Disable Center Reading (*)
Page 14
13
Symbol Length
To decode symbols with a specific length range for each symbology, this setting must be set through the serial command DIGIT=ab,c-d[CR] below.
Command Format: DIGIT=ab,c-d[CR]
a = code character A: Code39 C: Code128 d: DataMatrix
e: Composite, RSS E: UPC/JAN/EAN F: Codabar G: Code93 I: ITF L: PDF417 U: MaxiCode Q: QR Code z: AztecCode
p: Customer Barcode (Japan Post) b = Minimum length 1~2047 c = Maximum length 1~2047 d= Option CC: Composite Code RSS: GS1 Databar
Note: Other than Code 128, the Minimum / Maximum length includes Stop, Start, and Check Digit characters.
Note: the Minimum length must be less than the Maximum length.
Example1: Code39, 10 through 20 digits accepted.
DIGIT=A10, 20
Example2: GS1 Databar, 14 through 16 digits accepted.
DIGIT=e14, 16-RSS
For all symbologies, default values are b=1minimum), c=2047(maximum).
Page 15
14
Maximum decodable symbols per trigger input
The image reader can decode multiple symbols (u p to four symbols) in a single image with a single pull of the trigger.
To set the maximum number of symbols to be decoded for a single trigger input, scan the appropriate symbol below.
One symbol (*) Two symbols
Three symbols Four symbols
Multiple symbols separator
To set the separator character to be inserted between the symbol data when using multiple symbols reading, scan the appropriate symbol below..
None &
Comma(*) [FS] (1C hex)
[GS] (1D hex) [SP] (20 hex)
Page 16
15
Output order for multiple symbols reading
To set the output order (transmitting data order) for multiple symbols reading, scan several symbols in the proper sequence below. Unless otherwise specified, if an error occurs during a scanning sequence, just re-scan the correct parameter.
[Procedure]
(1) Set the maximum number of symbols to be decoded for a single trigger input. (previous page).
(2) Set the separator character to be inserted between the symbol data (previous page).
(3) Set the sorting method ( none, in the order of decoding, symbol lengths, specified characters, or
symbologies)
(4) Select the output sequence number to be programmed (up to 4).
(5) Set the item to be set (symbol lengths, First Character, Second Character, Type of Symbologies).
(6) Set the appropriate Data.
(a) To set the symbol lengths, use the Character Data” on page 27. (b) To set the first or second character, use the “Character Code” on page 26. (c) To set the symboogy, use the “Symbology type” on page 29 and 30.
(7) When setting is complete, scan the “Confirm” symbol to accept the changes or “Cancel” to revert back to the previous settings. These symbols can be found on page 30.
(8) Repeat steps (4) through (7) to set the remaining items.
(9) Finally scan the “Save Settings” symbol to save the settings to the unit’s non-volatile Flash memory.
Note: Multiple RSS composite codes cannot be decoded from a single image, but a single RSS composite
code may be decoded with other types of symbologies.
Sorting method
Not specified (in order of decoding) (*) Symbol lengths
Specified characters Type of symbologies
Page 17
16
・Output sequence number to be programmed
To set the output sequence number to be programmed, scan the appropriate symbol below.
Output 1 Output 2
Output 3 Output 4
Select the item to be set
To set the item to be set, scan the appropriate symbol below.
Symbol length First character
Second character Type of symbologies
Save Settings
(Write into Flash ROM)
Page 18
17
Addition of Symbology Identifier (AIM Code Identifiers)
A Symbology Identifier specifies the type of symbology of a scanned symbol. If this function is enabled, Symbol Identifier is added before the decoded data.
To Enable or Disable this function, scan the appropriate symbol below.
<Symbol Information Character> AIM Code Identifiers
Code39 ]A0 Code128 ]C0 EAN128 ]C1 Codabar ]F0 ITF ]I0 JAN/EAN/UPC (No-character) Maxi Code ]U1 Data Matrix ]d1 PDF417 ]L0 QR Code ]Q1 RSS ]e0 Code93 ]G0 Composite ]e0
Enable Disable
addition of Symbology Identifier addition of Symbology Identifier (*)
Save Settings
(Write into Flash ROM)
Page 19
18
Additional Symbol Information (Optional Data)
An optional single character (henceforth “Front Character) corresponding to the type of symbology of the decoded symbol may be inserted before the decoded data. And similarly another optional character (henceforth “End Character”) may be inserted after the decoded data.
[Procedure]
(1) Enable or Disable to activate each Front Character and End Character setting respectively.
(2) Set the Front Character and End Character respectively.
The user has to follow the procedures in order otherwise the setup will be ignored.
1) Enter the Setup procedure
2) Review Character Set (refer to Character Code section), and then confirm upper data and lower data of the Front/End Ccharacter respectively.
3) Scan the “Setup Front/End Character” for symbology type respectively.
4) Scan the “Character Data symbol corresponding to the upper data.
5) Scan the “Character Data symbol corresponding to the lower data.
Enable/Disable Front Character
To Enable or Disable Front Character, scan the appropriate symbol below.
Enable Disable
Front Character End Character (*)
Enter Setup procedure of Front character
To enter Setup procedure of Front Character, scan the appropriate symbol below.
Setup Front Character Setup Front Character
for Code39 for Code128
Setup Front Character Setup Front Character
for DataMatrix for JAN/UPC
Page 20
19
Setup Front Character Setup Front Character for Codabar for ITF
Setup Front Character Setup Front Character
for PDF417 for MaxiCode
Setup Front Character Setup Front Character
for QR-Code for EAN128
Setup Front Character Setup Front Character
for GS1 Databar for Code93
Setup Front Character Setup Front Character
for Composite for Customer Bar Code(Japan Post Code)
Setup Front Character
for AztecCode
Page 21
20
Enable/Disable End Character
To Enable or Disable End Character, scan the appropriate symbol below.
Enable Disable
End Character End Character (*)
Setup Optional End character
To enter Setup procedure of End character, scan the appropriate symbol below.
Setup End Character Setup End Character
for Code39 for Code128
Setup End Character Setup End Character
for DataMatrix for JAN/UPC
Setup End Character Setup End Character
for Codabar for ITF
Setup End Character Setup End Character
for PDF417 for MaxiCode
Page 22
21
Setup End Character Setup End Character
for QR-Code for GS1-128
Setup End Character Setup End Character
for GS1 Databar for Code93
Setup End Character Setup End Character
for Composite for Customer Barcode(Japan Post Code)
Setup End Character
for AztecCode
Page 23
22
Additional Optional Single Data
An optional single character (henceforth Front Data”) regardless to the type of symbology of the decoded symbol may be inserted before the decoded data. And similarly another optional character (henceforth “End Data”) may be inserted after the decoded data.
[Procedure]
(1) Enable or Disable to activate each Front Data and End Data setting respectively.
(2) Set the Front Data and End Data respectively.
The user has to follow the procedures in order otherwise the setup will be ignored.
1) Enter the Setup procedure
2) Review Character Set (refer to Character Code section), and then confirm upper data and lower data of Front/End Data respectively.
3) Scan the “Setup Front /End Data”.
4) Scan the “Character Data symbol corresponding to the upper data.
5) Scan the “Character Data symbol corresponding to the lower data.
Enable/Disable Front Data
To Enable or Disable Front Data, scan the appropriate symbol below.
Enable Front Data Disable Front Data(*)
Enter Setup procedure of Front Data
To enter Setup procedure of Front Data, scan the symbol below.
Setup Front Data
Save Settings
(Write into Flash ROM)
Page 24
23
Enable/Disable End Data
To Enable or Disable End Data, scan the appropriate symbol below.
Enable End Data Disable End Data(*)
Enter Setup procedure of End Data
To enter Setup procedure of End Data, scan the symbol below.
Setup End Data
Save Settings
(Write into Flash ROM)
Page 25
24
Control Code
A control code contained in a symbol may be changed to another form and then transmitted, i.e. the control code may be changed into the ASCII code enclosed in the parenthesis ( [ , ] ) and then transmitted.
Example:[SX]1234[EX] ==> [02]1234[03]
Method of Transmit Control Code
To set method of transmitting control code, scan the appropriate symbol below.
Pass Through (*) Changed to ASCII code within [ ].
Transmit Group Separator [GS]
To Enable or Disable transmitting Group Separator (GS) for GS1-128 symbology, scan the appropriate symbol below.
Enable Transmit GS (*) Disable Transmit GS
Page 26
25
Transmit Group Separator [FNC1]
Group Separator [FNC1] may be substituted to another single character. This function is available for GS-128, GS1 Databar only.
Default Setting Value:GS( 0x1D )
Setting Procedure is below to set this single character substituted for Group Separator [FNC1],
[Procedure]
The user has to follow the procedures in order otherwise the setup will be ignored.
1) Review Character Set (refer to Character Code section), and then confirm upper data and lower data of the singlel character.
2) Scan the “Setup optional character setting for GS below.
3) Scan the “Character Data symbol corresponding to the upper data from 0 through F..
4) Scan the “Character Data symbol corresponding to the lower data from 0 through F..
Setup optional character setting for GS
Page 27
26
Character Code
The Character Code is used to set the following functions: Set the Multiple symbols reading sort information Add Symbol Information Data Add optional data Transform optional character from GS
Character Set
Note: Scanners set to use the HID interface cannot output the data in the gray section.
UPPER DATA
L O W E R
D A T A
Page 28
27
Character Data
To input Character Data first, scan the upper data symbol, followed by the lower data symbol.
The same symbols can be used for both upper and lower data.
0 1
2 3
4 5
6 7
8 9
Page 29
28
A B
C D
E F
Save Settings
(Write into Flash ROM)
Page 30
29
Symbology Type
To select the symbology types to dedode, scan the appropriate symbol below.
Not specified (*) Code39
Code128 ITF
Codabar JAN/EAN/UPC
PDF417 QR-Code
DataMatrix MaxiCode
Page 31
30
GS1-128 Postal
GS1 Databar Composite Code
Code93 Aztec Code
Confirm / Cancel multiple reading setting
When setting of output order for multiple symbols reading is completed, scan the “Confirm” symbol to accept the changes or “Cancel” to revert back to the previous settings.
Confirm Cancel
Save Settings
(Write into Flash ROM)
Page 32
31
2.2. Symbol Reading setup
Code39
Code39 symbol reading Check Digit (C/D) verification: Modulus 43
To select the Code39 reading, scan the appropriate symbol below.
Read Code39 Read Code39
No C/D check (*) Check C/D
Transmit C/D
Read Code39 Read Code39
Check C/D No C/D check
No C/D transmission FULL ASCII On
Read Code39 Read Code39 Check C/D Check C/D
Transmit C/D No C/D transmission
FULL ASCII On FULL ASCII On
Disable Code39 decoding
Save Settings
(Write into Flash ROM)
Page 33
32
・Code39 Start / Stop Transmit
To Enable or Disable the transmission of ST/SP characters at the head and the end of the read data, scan the appropriate symbol below.
Transmit No transmission of
Code39 ST/SP Code39 ST/SP (*)
Code128
To Enable or Disable to decode Code128 symbol, scan the appropriate symbol below.
Enable Code128 decoding (*) Disable Code128 decoding
GS1-128(EAN128)
To Enable or Disable to decode GS1-128(EAN128) symbol, scan the appropriate symbol below.
Enable GS1-128 decoding (*) Disable GS1-128 decoding
Page 34
33
Codabar Setup
Enable / Disable CODABAR symbol decoding, Check Digit verification and transmission. C/D Verification: Modulus 16
To select tCodabar reading, scan the appropriate symbol below.
Read Codabar Read Codabar No C/D check (*) Check C/D
Transmit C/D
Read Codabar Disable Codabar decoding
Check C/D
No C/D Transmit
Codabar ST/SP Character Case
To select the Codabar Start / Stop characters to upper or lower case, scan the appropriate symbol below.
Codabar ST/SP Character Codabar ST/SP Character
Lower case Upper case (*)
Save Settings
(Write into Flash ROM)
Page 35
34
Codabar Start / Stop transmission
To Enable or Disable the transmission of the Codabar ST/SP characters, scan the appropriate symbol below
Transmit Codabar ST/SP (*) No Codabar ST/SP transmission
ITF Setup
Enables / Disables ITF (Interleaved 2 of 5) symbol decoding, Check Digit verification and transmission. C/D Verification: Modulus 10
To select ITF reading, scan the appropriate symbol below.
Read ITF Read ITF
No C/D Check (*) Check C/D
Transmit C/D
Read ITF Disable ITF decoding
Check C/D
No C/D transmission
Page 36
35
ITF Digits Setup
Set the amount of accepted number of digits for ITF symbols. The number of digits includes C/D.
To set up the number of digits for ITF symbols, scan the appropriate symbol below.
2 digits 4 digits
6 to 2047 digits (*)
Code93
To Enable or Disable Code93 symbol for decoding, scan the appropriate symbol below.
Enable Code93 decoding (*) Disable Code93 decoding
GS1 Databar(RSS)
To Enable or Disable GS1 (RSS) symbol for decoding, scan the appropriate symbol below.
Enable GS1 Databar decoding Disable GS1 Databar decoding (*)
Page 37
36
Setting the Application Identifier
Output the Application Identifier of GS1-128 and GS1 Databar by enclosed in the parenthesis. Outputs without parentheses ( Output directly ) if there are any defects in decoding data format..
To set the Application Identifier outputting type, scan the appropriate symbol below.
Output with additional parentheses Output directly (*)
Example: 010498702825577917080400104ZA38M (01)04987028255779(17)080400(10 )4ZA38M
Supported application identifier is below:
01, 10, 17, 21, 30, 7003, 91, 92, 93, 94, 95, 96, 97, 98, 99
Save Settings
(Write into Flash ROM)
Page 38
37
Composite
To Enable or Disable Composite symbol for decoding, scan the appropriate symbol below.
Enable Composite Symbol decoding Disable Composite Symbol decoding (*)
JAN/EAN/UPC Setup
To Enable or Disable JAN/EAN/UPC symbol for decoding, scan the appropriate symbol below.
Enable JAN/EAN/UPC decoding (*) Disable JAN/EAN/UPC decoding
JAN/EAN/UPC (Standard) Check Digit Transmission
To select the JAN-13/EAN-13 (Standard) C/D transmission, scan the appropriate symbol below.
JAN-13/EAN-13 (Standard) JAN-13/EAN-13 (Standard)
Transmit C/D (*) No C/D transmission
Page 39
38
JAN/EAN (Shortened) Check Digit Transmission
To select the JAN-8/EAN-8 (Shortened) C/D transmission, scan the appropriate symbol below.
JAN-8/EAN-8 (Shortened) JAN-8/EAN-8 (Shortened)
Transmit C/D(*) No C/D transmission
UPC-A Check Digit Transmission
To select the UPC-A C/D transmission, scan the appropriate symbol below.
UPC-A Transmit C/D(*) UPC-A Disable C/D Transmission
UPC-E Check Digit Transmission
To select the UPC-E C/D transmission, scan the appropriate symbol below.
UPC-E Transmit C/D(*) UPC-E No C/D transmission
Save Settings
(Write into Flash ROM)
Page 40
39
UPC-A Number System transmission
To Enable or Disable UPC-A Number System transmission, scan the appropriate symbol below.
Transmit UPC-A No transmission of UPC-A Number System (*) Number System
UPC-E Number System Transmission
To Enable or Disable UPC-E Number System transmission, scan the appropriate symbol below.
Transmit UPC-E No transmission of UPC-E Number System (*) Number System
Page 41
40
UPC-E Format Conversion
To Enable or Disable the conversion UPC-E codes to UPC-A format, scan the appropriate symbol below.
Format Conversion No Format Conversion
to UPC-A (*)
UPC Output Digits
To Enable or Disable the conversion of adding A zero(0) to the beginning of the data when UPC 12 digits symbol read , scan the appropriate symbol below.
12 digits code unchanged (*) 12 digits code converted to 13 digits
Note: If UPC-E format conversion is NOT enabled the 12 digit code is left unchanged.
Page 42
41
DataMatrix Setup
Enable / Disable DataMatrix decoding and set reading parameters. Supports ECC200 Symbology only.
To select DataMatrix reading, scan the appropriate symbol below.
Enable DataMatrix decoding Enable DataMatrix decoding
Shape: Square Shape: Square
Marking: Dark on Light (*) Marking: Light on Dark
Enable DataMatrix decoding
Shape: Square
Marking: Dark on Light & Light on Dark
Enable DataMatrix decoding Enable DataMatrix decoding Shape: Square & Rectangle Shape: Square & Rectangle
Marking: Dark on Light Marking: Light on Dark
Enable DataMatrix decoding Disable DataMatrix decoding Shape: Square & Rectangle
Marking: Dark on Light & Light on Dark
Page 43
42
DataMatrix Cell Size
To select the reading cell size for Data Matrix codes, scan the appropriate symbol below.
Normal Cell Size (*) Small Cell Size
Smaller Cell Size
Save Settings
(Write into Flash ROM)
Page 44
43
・Maxi Code Setup
Enable / Disable MaxiCode decoding and set the mode.
To select Maxi Code reading, scan the appropriate symbol below.
Enable MaxiCode decoding Enable MaxiCode decoding
All Modes (*) Mode 0
Enable MaxiCode decoding Enable MaxiCode decoding
Mode 1 Mode 2
Enable MaxiCode decoding Enable MaxiCode decoding
Mode 3 Mode 4
Enable MaxiCode decoding Disable Maxi Code decoding
Mode 5
Page 45
44
Transmission of Primary
To Enable or Disable the data transmission for decoding primary of Maxi Code (primary only), scan the appropriate symbol below.
Enable primary transmission (*) Disable primary transmission
PDF417
To Enable or Disable PDF417 symbol for decoding, scan the appropriate symbol below.
Enable PDF417 decoding (*) Disable PDF417 decoding
Save Settings
(Write into Flash ROM)
Page 46
45
QR Code Setup
Enable / Disable QR-Code decoding and set the marking type.
To select QR Code reading, scan the appropriate symbol below.
Enable QR Code decoding Enable QR Code decoding
Marking: Dark on Light (*) Marking: Light on Dark
Enable QR Code decoding Disable QR Code decoding
Marking: Dark on Light & Light on Dark
Save Settings
(Write into Flash ROM)
Page 47
46
Customer Barcode(Japan Post Code)
To Enable or Disable Customer Barcode (Japan Post Code) symbol for decoding, scan the appropriate
symbol below.
Enable Customer Disable Customer Barcode (*) Barcode decoding
To Enable or Disable the reading of incomplete Customer Barcode symbol, scan the appropriate symbol
below.
Read incomplete symbols also (*) Read complete symbols only
Save Settings
(Write into Flash ROM)
Page 48
47
Aztec Code
Enable / Disable Aztec Code decoding and set the marking type.
To select Aztec Code reading, scan the appropriate symbol below.
Enable Aztec Code decoding Enable Aztec Code decoding
Marking: Dark on Light (*) Marking: Light on Dark
Enable Aztec Code decoding Disable Aztec Code decoding
Marking: Dark on Light and Light on Dark
Save Settings
(Write into Flash ROM)
Page 49
48
3. Operational Setup
3.1 General Operational Setup
Writes Setup Values
To save all current settings into the device’s non-volatile flash memory, scan the symbol below.
Save Settings
(Write Flash ROM)
Restore factory default settings
To return all settings to their default states, scan the symbol below.
Restore Factory Default Settings
Page 50
49
My Settings
The scanner can register multiple separate configurations in non-volatile memory. This function should be utilized when multiple types of marking technologies needed to be read.
Registration of My Setting
To register the configuration in to My setting, scan the appropriate symbol below.
Register the configuration into My setting 1 Register the configuration into My Setting 2
Load registered My Settings
To load the registered My Setting into reader configuration, scan the appropriate symbol below.
Load My Setting 1 Load My Setting 2
Page 51
50
Buzzer setup
To Enable or Disable the buzzer indicator, scan the appropriate symbol below.
Enable Buzzer (*) Disable Buzzer
Vibration
To Enable or Disable the vibrator indicator, which indicates successful decoding, scan the appropriate symbol below.
Disable Vibrator Enable Vibrator (*)
Save Settings
(Write into Flash ROM)
Page 52
51
Continuous Reading Mode
Do not trigger read while the reader is on continuous reading mode. Autosense mode should be disabled when using the continuous reading mode.
Setting for Continuous Reading Mode
To Enable or Disable Continuous Reading Mode, scan the appropriate symbol below.
Enable Continuous Reading Mode Disable Continuous Reading Mode
Save Settings
(Write into Flash ROM)
Page 53
52
Continuous Reading Mode Interval
To set the interval time between successive scans in continuous reading mode, scan the appropriate symbol below.
Interval: 0 s (*) Interval: 1 s
Interval: 2 s Interval: 3 s
Interval: 4 s Interval: 5 s
Interval: 6 s Interval: 7 s
Interval: 8 s Interval: 9 s
Page 54
53
Prohibit Same Symbol decoding in Continuous Reading Mode
To Enable or Disable reading of the same symbol when in continuous reading mode, scan the appropriate symbol below.
Disable Same Symbol prohibition (*) Enable Same Symbol Prohibition
Same Symbol prohibition duration in Continuous Reading Mode
To set the Prohibit Duration time for same symbol reading in Continuous Reading Mode, scan the appropriate symbol below.
,.
Prohibit Duration: 0.5s Prohibit Duration: 1.5s
Prohibit Duration: 5s Prohibit Duration: 10s
Prohibit Duration: Prohibit Duration: Increment by 0.5s Decrement by 0.5s
Page 55
54
Autosense Mode
To Enter or Escape Autosense mode, scan the appropriate symbol below.
.
Note: Autosense mode is invalid while in Continuous Reading Mode. Continuous Reading Mode needs to be
disabled before enabling Autosense mode.
Enter Autosense Mode Escape Autosense Mode
Save Settings
(Write into Flash ROM)
Page 56
55
Autosense Mode timeout
To set the duration time limit (Time out ) to read symbol after detecting a label coming in, scan the appropriate symbol below.
Time out: 1s Time out: 2s
Time out: 3s (*) Time out: 4s
Time out: 5s Time out: 6s
Time out: 8s Time out: 10s
Page 57
56
Decode Time out
When the scanner cannot decode the symbol within the limited time, it will stop decoding. This mode needs the setting of maximum timeout time . Increasing the setting time when the symbol data size is large and needs extra time to decode. Decreasing the setting time when the data size is small that takes shorter time to decode.
To set the maximum timeout time, scan the appropriate symbol below.
0.5s 1s (*)
5s 10s
Timeout time Timeout time
Increment by 0.5s Decrement by 0.5s
Page 58
57
Pointer in Autosense mode
Enable / Disable the pointer while in Autosense mode.
Note: The pointer will blink during decode, regardless of this setting,.
To Enable or Disable the pointer blinking, scan the appropriate symbol below.
Enable pointer (*) Disable Pointer
Autosense sensitivity
Set the sensitivity of Autosense mode.
Note: High sensitivity makes detection of labels easier, but may cause unintended triggers.
To set the Autosense sensitivity , scan the appropriate symbol below.
0:Highest sensitivity 1:High sensitivity
2:Normal sensitivity (*) 3:Low sensitivity
4:Lowest sensitivity
Page 59
58
Prohibit Same Symbol decoding in Auto Detection mode.
To Enable or Disable Same Symbol prohibition in Auto Detection mode, scan the appropriate symbol below.
Disable Same Symbol prohibition Enable Same Symbol prohibition (*)
Same Symbol Prohibition duration in Auto Detection Mode
To set the prohibited time for same symbol reading in Auto Detection mode, scan the appropriate symbol below.
Prohibit Duration: 0.5s Prohibit Duration: 1s
Prohibit Duration: 5s Prohibit Duration: 10s t
Prohibit Duration Prohibit Duration Increment by 0.5s Decrement by 0.5 s
Save Settings
(Write into Flash ROM)
Page 60
59
Cropping Image area
Set the image cropping area.
Note: Vertical 25% and horizontal 25% is an invalid setting, all other combinations are possible.
To set the image cropping area size in Auto Detection mode, scan the appropriate symbol below for Horizontal size and Vertical size respectively.
Horizontal:
Full size (*) 75%
50% 25%
Vertical:
Full size (*) 75%
50% 25%
Page 61
60
Quick Setting with Function Button
Enables / disables the function button on the quick setting 1 and 2. This setting prevents the change of the mode of the operation when the operation mode is configured incorrectly.
Note: Please refer to the operation manual of THIR-6780 series for quick setting 1 and 2.
To set the function button, scan the appropriate symbol below.
Disable quick setting 1 and 2
Enable quick setting 1 (*)
Enable quick setting 1 and 2
Save Settings
(Write into Flash ROM)
Page 62
61
3.2 Setting Camera Control
AGC
Enable/Disable AGC (auto gain control) of the internal-camera.
Enabled AGC”: the camera gain is adjusted automatically whenever scanner reads symbol. Disabled AGC”: when the “Disable AGC” (below) is scanned, the camera gain is held at just its gain value.
. To Enable or Disable AGC, scan the appropriate symbol below.
Enable AGC (*) Disable AGC
Illumination
To set the illumination lights to read symbols, scan appropriate symbol below.
All illumination OFF Upper illumination ON (*)
Lower illumination ON All illumination ON
Lower illumination always ON
Save Settings
(Write into Flash ROM)
Page 63
62
3.3 Preset Mode setting
The scanner has the function of Preset Mode function that is used for verification of the decoded data. The scanner compares the decoded data with the preset data (Registered data) and will output only if the data is matched regardless of its symbology type. Preset Mode has two modes, Preset Mode 1 and Preset Mode2.
Preset Mode 1: Preset data is the first decoded one after power up. Preset Mode 2: Preset data is registered in advance by using the barcode menu or serial command.
Preset Mode 0
To cancel Preset Mode (Preset Mode : disabled), scan the symbol (Preset Mode 0 ) below.
Preset Mode 0 (*)
(Cancel Preset Mode)
・Preset Mode 1
Preset data is the first decoded one after power up. Subsequent symbols will be read and compared with the preset data, resulting, in OK if they were the same as the preset data , or NG if they were different. The preset data is cleared when the scanner is powered OFF.
To set the scanner for Preset Mode1, scan the symbol (Preset Mode 1) below and then scan the symbol ( Save of Setting ) to write into Flash ROM. Then restart (power OFF and ON) the scanner.
Preset Mode 1
Page 64
63
Preset Mode 2
This mode would registered the preset data by using the barcode menu or serial commands. Both for the perfect matching and partial matching are available on data verification. The preset data can be also stored into the non-volatile memory.
To set Preset Mode 2, scan the symbol (Preset data 2 ) below and follow the procedure below.
Preset Mode 2
Preset data registration
This registration is for complete matches only. To set the Preset data ,scan the symbol (Set Preset Data ) below, and followed by scanning the adequate symbols as preset data.
Set Preset Data
Save Settings
(Write into Flash ROM)
Page 65
64
Setting for Digits
To decode symbols with a specific length range for each symbology, this setting must be set through the serial command DIGIT=ab,c-d[CR] below.
To enable the partial match verification, transmit the serial command (SET=PRENa ) from the host
computer.
Transmit the command of digits setting from the host computer to enable the partial match verification.
Command SET=PRENa[CR] a = 0 No verification of digits a = 1~ 100
For no verification of preset data digits, read the bar code below.
No verification of preset data digits
Setting for Verifying Character’s
Transmit the command from host computer to set partial match verification of the column number setting. By typing the wild card character “?” in the preset data, the character on the column number can be omitted from the verification. With the wild card, the scanner considers every value as a matched regardless of the value of the character on the column data from the symbol data. The character “?” cannot be verified.
Command SET=PREDabcdef… [CR]abcdef…: Preset data
SET=PRED?[CR] No verification of every characters
NOTE) Read the bar code menu to set the control code ( 00[hex] ~ 1F[hex], 7F[hex] ) .
Read the bar code below for not to verify all the characters in the preset data. ( SET=PRED? )
Set Preset Characters not to be verified
Page 66
65
Example of Preset data
Example 1: Compare with preset "12345" and read data.
Result example: 12345 Match 1234 NOT match 012345 NOT match
●Preset data by barcode menu Scan the adequate symbols in following sequence.
1) Scan the “Preset Mode 2” symbol.
2) Scan the “Set preset Data” symbol.
3) Scan the “Character Data "symbols for “1”,“2”,3”,”4” and ”5" respectively.
4) Scan the “Save Settings” symbol.
●Preset data by serial command Send serial commands to the scanner from host computer as following sequence.
1) PREM=2[CR]
2) SET=PRED12345[CR]
3) WSETS[CR]
Example 2: Compare with first4 digits as “ABCD” (No specific Digits)
Result Example ABCD3333 Match ABCD7777777 NOT Match DABC3333 NOT Match ABC77777777 NOT Match
●Preset data by barcode menu
1) Scan the “Preset Mode 2” symbol.
2) Scan the “Set preset Data” symbol.
3) Scan the “Character Data "symbols for “A”,“B”,C”, and D" respectively.
4) Scan the “Save Settings” symbol.
●Preset by serial command Send serial commands to the scanner from host computer as following sequence.
1) PREM=2[CR]
2) SET=PREDABCD[CR]
3) SET=PREN0[CR]
4) WSETS[CR]
Example 3) When 10 digits are expected, and the 3rd through 6th digits should be "ALFA".
Result Example 00ALFA1234 Match AAALFAAAAA Match 00ALFA12344 NOT Match 0ALFA01234 NOT Match
Page 67
66
●Preset barcode menu
It is not capable to setup only barcode menu.
●Setup by Sending Command Send serial commands to the scanner from host computer as following sequence.
1) PREM=2[CR]
2) SET=PRED??ALFA????[CR]
3) SET=PREN10[CR]
4) WSETS[CR]
Transmitting Preset Status
Output the current preset setting status. To output the status, read the barcode menu of preset status transmission below.
Transmitting Preset Status
Command ?pre [CR]
Output Example PREM=0 (0:non 1:power on 2:saved) PRESET LENGTH:41 DATA(HEX): 31 32 33 3F 3F 3F 3F 3F 3F 3F 3F 41 42 43 43 44 45 03 04 05 3F 3F 3F 3F 3F 3F 3F 3F 46 47 48 49 3F 3F 3F 3F 3F 3F 39 31 30 DATA(ASCII): 123????????ABCCDE***????????FGHI??????910
Output Format PREM=a (0:non 1:power on 2:saved)[CR] PRESET LENGTH:b[CR] DATA(HEX):[CR] XX XX XX XX XX XX XX XX XX XX[CR] XX XX XX XX XX XX XX XX XX XX[CR] XX XX XX XX [CR] DATA(ASCII):[CR] xxxxxxxxxxxxxxxxxxxxxxxx
a : Preset mode b : The number of Preset data digits XX XX … : Preset data characters, displayed as Hexadecimal number pairs
xxxxxx… : Preset data character( ASCII/JIS Character code) Preset data is including of control character, the control characters converted by “*”.
Page 68
67
4. Diagnosis
Output the Decode Time
The actual time consumed during symbol decoding, (starting with the SYNC ON event), can be appended to the output data in the serial interface output.
Added Decode Time NOT Added Decode
Output Example 1912345678907(0238ms)[CR]
Format <Header>•<read data><aaaa>ms•<Terminator> Where <aaaa>=4 digits of decode time in mil second.
Page 69
68
Output Actual Reading Statistics
A statistical report of actual reading quality based on decode time can be output through the serial interface. The report contains minimum, maximum and average times for OK reads and Bad reads, and also the total count of SYNC events, OK reads and Bad reads. The report covers the time period since the last read barcode menu of Clear Decode Time, Output Reads Count, or else since power ON. Report explanation:
“OK” denotes the cases when bar code reading and decode were successful. “NG” denotes the cases when bar code reading or decode failed.
When multiple bar code label reading is enabled, the OK designation means that ALL labels read OK; The NG designation means that at least one label reading failed. (Multiple label symbol reading is an optional feature.)
Decode Time, Clear Decode Time,
Output Read Count Output Read Count
Output Example *** TOTAL *** NG 2:OK 175/SYNC 177 NG 1.12%:OK 98.87%
(Output Format *** TOTAL ***[CR] NGaaaaa:OKbbbbb/SYNCccccc[CR] NGddd.dd%:OKeee.ee%[CR]
aaaaa : The number of NG reads ( 0 ~ 65535, more displays 65535) bbbbb : The number of OK reads (0 65535, more displays 65535) ccccc : The number of decode trials ( 0 65535, more displays 65535) ddd.dd : The average of NG reads (0.00 ~ 100.00, displays 2 decimal places) eee.ee : The average of OK reads (0.00 100.00, displays 2 decimal places)
Page 70
69
Output Actual Reading Statistics2
The report of an actual reading which is based on the numbers of decodes attempts (shortest / longest / average decoding time and reading time can be output) after the power activation. The data will be erased when the scanner is turned off or when the bar code "Erase decoding time and reading time" is read.
“OK” denotes the cases when bar code reading and decode were successful. “NG” denotes the cases when bar code reading or decode failed.
When multiple bar code label reading is enabled, the OK designation means that ALL labels read OK; The NG designation means that at least one label reading failed. (Multiple label symbol reading is an optional feature.)
Output decoding time and numbers of reading Erase decoding time and numbers of reading
Example Output
*** DECODE TIME *** OK: min(0186ms),max(0271ms),ave(0238ms) NG: min(0382ms),max(1000ms),ave(0691ms) NG 2:OK 177/SYNC 179
Format
*** DECODE TIME ***[CR] OK: min(aaaams),max(bbbbms),ave(ccccms)[CR] NG: min(ddddms),max(eeeems),ave(ffffms)[CR] NGggggg:Okhhhhh/SYNCiiiii[CR]
aaaa : The shortest decode time for OK reads (0000~6000) bbbb : The longest decode time for OK reads ( 0000~6000 ) cccc : Average decode time for OK reads ( 0000~6000 ) dddd : The shortest decode time for NG reads ( 0000~6000 ) eeee : The longest decode time for NG reads ( 0000~6000 ) ffff : Average decode time for NG reads ( 0000~6000 ) ggggg : The number of NG reads ( 0~65535, more displays 65535 ) hhhhh : The number OK reads ( 0~65535, more displays 65535 ) iiiii : The number of SYNC events( 0~65535, more displays 65535 )
Page 71
70
Output of Bar Code Position Information
Set the output for the position information of decoded symbol.
a)Barycentric coordinates
Output the central coordinate of the decoded symbol. The origin coordinate is the upper left (000,000) on the display.
(Output example) 100000000990703(+312,+255)
(Output format)
<Header>•<read data>(abbb,accc)•<Terminator> a :+ or ­bbb: Read Symbol Center of X coordinate(-999~+999) ccc: Read Symbol Center of Y coordinate(-999~+999)
b) 4 Corner Coordinate Data
Coordinates of the four corners of the symbols are determined and added to the output data. The screen upper left corner serves as the Origin point (000, 000).
Example Output
100000000990703(+269,+011)(+455,+086)(+386,+270)(+198,+199)
Format
<Header>•<read data> (A1)(A2)(A3)(A4)•<Terminator> A1~A4:(abbb,accc) Output coordinates of points A1, A2, A3, and A4 in that order each the following format. a :+ or – bbb: = X coordinate of a bar code corner (-999~+999)
ccc: = Y coordinate of a bar code corner (-999~+999)
Page 72
71
Reference 4 Coordinate Position of Each Symbol
1 dimensional barcode
2 dimensional barcode
MaxiCode
QRCode PDF417
DataMatrix
A1 A2
A4 A3
A1 A2
A4 A3
A1 A2
A4 A3
A1 A2
A4 A3
A1 A2
A4 A3
A1 A2
A4 A3
Page 73
72
c) Output of Both Geometrical Center and 4 Corner Coordinates
Data of the geometrical center coordinates and 4 corner coordinates are both output to the serial interface with the read data. The origin coordinate is the upper left (000,000) on the display.
(Output example) 100000000990703(+140,+326)(+269,+011)(+455,+086)(+386,+270)(+198,+199)
Format
<Header>•<read data><>(A1)(A2)(A3)(A4)•Terminator B:Geometric Center
(A1)(A2)(A3)(A4):Coordinates of 4 corners
B、A1~A4:(abbb,accc) Output coordinates of points B, A1 through A4 in that order each the following format.
a :+ or ­bbb:X coordinate (-999~+999) ccc:Y coordinate (-999~+999)
Setup Output Coordinate
NOT Output Coordinate Output Geometric Center
Output 4 Corner Coordinate Output Geometric
Center and 4 Corners
Coordinate
Page 74
73
5. Setting Reference
Output the current setting of the reader (status).
Status1
Transmit Status 1
(Output example) ******** STATUS ******** THIR-XXXX SHUTT=1 (0:1/60 1:1/125 2:1/250 3:1/500 4:1/1000) (5:1/2000 6:1/4000 7:1/6000 8:1/8000) GCV=6 (1-11) AGC_ENABLE:1 (0:disable 1:enable) LIGHT=1 (0,2:OFF 1,3:ON) LABELTX=0 (0:through 1:[HEX]) ILLUM=1 (0:OFF 1:IN 2:EX 3:BOTH 4:LEAVE EX ON) SYMBOLTX=0 (0:only data 1:add symbol information to data) keep decoding:0 (0:normal decode 1:keep decoding mode) contintvl=0 (interval time[s] for keep decoding mode) HEAD=0 (0:non 1:[SX] 2:[EC]) TERM=3 (0:non 1:[EX] 2:[EX][CR] 3:[CR][LF] 4:[CR]) (5:[CR][TAB] 6:[TAB][CR]) FRAME=4 (0:7O1 1:7O2 2:7E1 3:7E2 4:8N1) (5:8N2 6:8O1 7:8O2 8:8E1 9:8E2) BAUD=9600 (1200,2400,4800,9600,19200,38400,57600,115200) ********* END ********** THIR-XXXX
Description of Status 1
SHUTT=_ Shutter speed (Second)
0:1/30 1:1/60 2:1/125 3:1/250
4:1/500 5:1/2000 6:1/4000 AGC= Transmitted AGC value to camera 0 – 255 200 AGC_ENABLE: Setting enable or disable Valuable AGC
1 Auto Control AGC Value 0 Fixed AGC Value
LIGHT=_ Illumination Setting
0: Auto Flash (After First Time Off, then AUTO) 1: Auto Flash (After First Time On, then Auto)
2: Always Off 3: Flash Every Reading LABELTX= Transmit Control Code
0: Transmit 1: Convert ASCII Code
Save Settings
(Write into Flash ROM)
Page 75
74
SYMBOLTX= Prefixed Symbol Information
0: Not Add Prefix Symbol Information
1: Add Prefix Symbol Information
keep decoding: Continuous Reading Mode
0 Dark on Light Mode 1 Continuous Reading Mode
contintvl= Continuous Reading Interval Mode (Second)
0 - 9 : Second-9Second 1Second
GOUTMODE=_ Image Output Mode
0: Disable Image output 1: Enable Image output, Protocol: XMODEM(SUM128) 2: Enable Image output, Protocol: XMODEM(CRC16)
GOUTSIZE= Image Size
0:644 pixel×494 pixel (Full image)
1:320 pixel×247 pixel (1/4 image)
2:160 pixel×123 pixel (1/16 image)
HEAD= Header
0: Non parity 1:[SX] 2:[EC]
TERM= Terminator
0: Non parity 1:[EX] 2:[EX][CR] 3:[CR][LF] 4:[CR] 5:[CR][TAB] 6:[TAB][CR]
FRAME= Frame Format (bits, parity, stop bit)
0:701 1:7O2 2:7E1 3:7E2 4:8N1
5:8N2 6:8O1 7:8O2 8:8E1 9:8E2 BAUD= Baud rate [bps]
1200 2400 4800 9600
19200 38400 57600 115200
Page 76
75
Status 2
Transmit Status 2
Output Example
******** STATUS ******** THIR-XXXX RSCS=0 (0: OFF 1: ON) C39SS=0 (0: not trans. 1: trans.) CODASS=1 (0: not trans. 1: trans.) CODACS=1 (0: small 1: capital) SEPA=2 (0:non 1:& 2:, 3:[FS] 4:[GS] 5:[SP]) UPCTX=0 (0:12-digit 1:13-digit) PREFIX=0 (0: off 1:[NUL]) SUFFIX=0 (0: off 1:[NUL]) E128GS=1 (0: non 1:[GS]) CODACHK=0 (0:standard 1:7DR) << SYMBOLOGIES MODE >> Symbology mode min max start length Head Foot Code39 1 1 2047 1 2047 0:[ A], 0:[ A] Code128 1 1 2047 1 2047 0:[ C], 0:[ C] DataMatrix 1 1 2047 1 2047 0:[ d], 0:[ d] JAN/UPC 1 1 2047 1 2047 0:[ E], 0:[ E] CODABAR 1 1 2047 1 2047 0:[ F], 0:[ F] ITF 1 6 2047 1 2047 0:[ I], 0:[ I] PDF417 1 1 2047 1 2047 0:[ L], 0:[ L] MaxiCode 3F 1 2047 1 2047 0:[ U], 0:[ U] QR-Code 1 1 2047 1 2047 0:[ Q], 0:[ Q] PostalCode 0 1 2047 1 2047 0:[ p], 0:[ p] EAN-128 1 1 2047 1 2047 0:[ e], 0:[ e] RSS 00 1 2047 1 2047 0:[ R], 0:[ R] Code93 1 1 2047 1 2047 0:[ G], 0:[ G] Composite 00 1 2047 1 2047 0:[ c], 0:[ c] AztecCode 1 1 2047 1 2047 0:[ z], 0:[ z] ********* END ********** THIR-XXXX
Description of Status 2
RSCS= RS/CS Control
0:RS/CS Control Not carries out
1:RS/CS Control carries out. C39SS= Transmit Code39 ST/SP Code
0:Not Transmit 1:Transmit
CODASS= Transmit Codabar ST/SP Code
0:Not Transmit 1:Transmit
Save Settings
(Write into Flash ROM)
Page 77
76
CODACS= Codabar ST/SP Character
0:Lower Case Letter 1:Upper Case Letter
SEPA=_ Separator Setting
UPCTX=_ Output Digits of UPC Code
0:12 digits 1:13 digits
E128GS=_ Transmit Control Character [GS]
0:Not Transmit 1:Transmit
mode Reading Mode min Reading Minimum Digits (1-2047) ma Reading Maximum Digits (1-2047) start Start Edit Digits (1-2047) length Transmit Edit Digits (1-2047)
Code39: Reading Code39 (mode)
0 Disable 1 Read, DISABLE C/D CHECK 2 Read, ENABLE C/D CHECK, C/D Transmit 3 Read, ENABLE C/D CHECK, C/D Not Transmit 4 Read, DISABLE C/D CHECK, FULL ASCII On 5 Read, ENABLE C/D CHECK, C/D Transmit、FULL ASCII On 6 Read, ENABLE C/D CHECK, C/D Not Transmit、FULL ASCII On
Code128: Read Code128 (mode)
0 Disable 1 Read, ENABLE C/D CHECK, C/D Transmit
Page 78
77
DataMatrix: Read DataMatrix (mode)
0 Disable 1 Read, Square, Dark on Light label 2 Read, Square, Light on Dark label 3 Read, Square, Dark on Light & Light on Dark label 5 Read, Square & Rectangle, Dark on Light label 6 Read, Square & Rectangle, Light on Dark label 7 Read, Square & Rectangle, Dark on Light & Light on Dark label
JAN/UPC: Read JAN/EAN/UPC (mode)
0 Disable 1 Read, ENABLE C/D CHECK,
CODABAR: Read Codabar (mode)
0 Disable
1 Read, DISABLE C/D CHECK
2 Read, ENABLE C/D CHECK, C/D Transmit
3 Read, ENABLE C/D CHECK, C/D Not Transmit
ITF: Read ITF (mode)
0 Disable
1 Read, DISABLE C/D CHECK
2 Read, ENABLE C/D CHECK, C/D Transmit
3 Read, ENABLE C/D CHECK, C/D Not Transmit
PDF417: Read PDF417 (mode)
0 Disable
1 Read,
MaxiCode: Read MaxiCode (mode)
Display Mode Base on 16 bit format, and Bit 0 through Bit 5 indicate Mode 0 through 5. (1: Enable, 0: Disable)
3F (Read All Mode)
QR-Code: Read QR Code (mode)
0 Disable
1 Read, Dark on Light label
2 Read, Light on Dark label
3 Read, Dark on Light & Light on Dark label
PostalCode: Read customer barcode (Japan Post Code) ( mode ) 0: Disable 2: Read customer bar code (Japan Post Code)
Page 79
78
EAN128: Read GS1-128 (mode) 0: Disable 1: Read
RSS: Read GS1 Databar (mode) 0: Disable 1: Read
Code93: Read Code93 (mode) 0: Disable 1: Read
Composite: Read Composite (mode) 0: Disable 1: Read
AztecCode: Read AztecCode (mode) 0: Disable
1 Read, Dark on Light label 2 Read, Light on Dark label 3 Read, Dark on Light & Light on Dark label
Page 80
79
Status 3
Transmit status 3
Output Example
******** STATUS ******** THIR-XXXX LABELS=1 (1-4:labels) OUTFORM=0 (0:no check 1:digit 2:chara 3:symbol) CheckNo. digit chara1 chara2 symbol check[1] : 0 3F 3F ? check[2] : 0 3F 3F ? check[3] : 0 3F 3F ? check[4] : 0 3F 3F ? XYTX=0 (0:non 1:add(x,y)) TXWAIT=1000 (1000-2500,step10) ********* END ********** THIR-XXXX
Description of Status 3
LABELS= Numbers of Label OUTFORM= Output Data Order Sequence check[1] Setting Label No.1 check[2] Setting Label No.2 check[3] Setting Label No.3 check[4] Setting Label No.4 digit Setting Label No.n Digits chara1 Compare Setting Label No.nCharacter (1st Byte) chara2 Compare Setting Label No.nCharacter (2nd Byte)
symbol Setting Symbol Label No.
XYTX=_ Output Read label coordinate
0: Disable
1: Output Geometric Center Coordinate
2: Output 4 Corner Coordinate
3: Output Geometric Center Coordinate and 4 Corner Coordinate
TXWAIT=_ Transmit Read Data Timeout (ms) 1000 – 2500 ms(by 10 ms)
Save Settings
(Write into Flash ROM)
Page 81
80
Status 4
Transmit status 4
(Output example)
******** STATUS ******** THIR-XXXX ILLUMINT=50,70 ( 0-80, 0-100 ) FNCBTN=1 ( 0:disable(all) 1:enable(switch) 2:enable(all) ) SENDCHAR=¥0D ( ¥00~¥FF ) SENDIMG=1 ( 1:Full 2:1/2 3:1/4 4:1/8 ) MODE=0 0:normal 1:image-out DECODELIM=1000 100-10000 step10 DTTX=0 0:non 1:add(****ms) MIRROR=0 0:normal 1:mirror JPOST=0 0:fuzzy 1:perfect UPCE=0 0:UPC-A form 1:UPC-E form UPCANS=0 UPCENS=0 0:output number system 1:strip UASUM=0 UESUM=0 0:output UPC chksum 1:strip JE13SUM=0 JE8SUM=0 0:output EAN/JAN chksum 1:strip MAXIPS=0 0:prim. or prim.+sec. 1:prim.+sec. DMSIZE=0 (0:normal 1:smaller 2:very small) POSTALD=0 typ:3500-7000 VERIFY=0 (0:OFF 1:ON) VWAIT=3(x500mS 1-20 ) GRVAREA=0 buz=1 (0:OFF 1:ON) vibrate=0 (0:OFF 1:ON) GS1AI=0 (0:disable 1:enable) ********* END ********** THIR-XXXX
Description of Status 4 ILLUMINT= The brightness of lower illumination when the lower illumination is always ON (ILLUM=4) First value:The brightness when the scanner is on standby Second value:The brightness at the reading
FNCBTN=_ Function button control 0: Disable function button 1: Enable function button (Quick setting 1 only) 2:Enable function button (Both of quick setting 1 and 2)
Save Settings
(Write into Flash ROM)
Page 82
81
SENDCHAR= Output data when the function button is pressed (Available only when the function button is set to the character string output) ¥0D ( ¥00~¥FF ) *up to 2 characters are settable. (Example: ¥0D¥OA)
SENDIMG=_ Output image size when the function button is pressed (Available only when the function button is set
to the image output)
1: Full 2: 1/2 3: 1/4 4: 1/8
MODE=_ Setting for binary output of image by command 0: No output by command 1: Output by command
DECODELIM=_ Setting Decode Timeout (ms)
100 - 10000ms
DTTX=_ Decoding time 0:Decoding time added 1: No decoding time added
MIRROR=_ Mirror Image
0: Read, Dark on Light
1: Read, Mirror Image
JPOST=_ Read Japan Post Code
1:Read Incomplete label 2:Read Perfect label
UPCE=_ UPC-E Format Convert
0: Convert UPC-A Format 1: Not Convert
UPCANS=_ Transmit UPC-A Number System
0: Transmit 1: Not Transmit
UPCENS=_ Transmit UPC-E Number System
0: Transmit 1: Not Transmit
UASUM=_ Transmit UPC-A C/D
0: Transmit 1: Not Transmit
UESUM=_ Transmit UPC-E C/D
0: Transmit 1: Not Transmit
JE13SUM=_ Transmit JAN/EAN Standard C/D
0: Transmit 1: Not Transmit
JE8SUM=_ Transmit JAN/EAN Shortened C/D
0: Transmit 1: Not Transmit
MAXIPS=_ Transmit Maxi Code Primary
0: Transmit 1: Not Transmit
Page 83
82
DMSIZE= Cell size of DataMatrix 0: Default cell size 1: Small cell size 2: Smaller cell size
VERIFY= Prohibition of continuous reading same symbol
0: Normal Continuous Reading 1: Prohibit continuous reading same symbol
VWAIT= Prohibition duration of continuous reading same symbol
1.5secs Values between 1~20(0.5 sec~10 sec)
GRVAREA= Center reading mode 0: Disable 1: Enable
buz=_ Buzzer setting 0: Buzzer OFF 1: Buzzer ON
vibrate= Vibration setting 0: Vibration OFF 1: Vibration ON
GS1AI=_Outputs with putting parenthesis around the application identifier
0: Output putting with parentheses 1: Output directly
Page 84
83
Status IMG
Check the reading area cropping status.
Transmit status IMG
(Output example)
******** STATUS ******** THIR-XXXX IMODE=0 PX=0 PY=0 WX=752 WY=480 CAPX=0 ( 0:100%, 1:75%, 2:50%, 3:25% ) CAPY=0 ( 0:100%, 1:75%, 2:50%, 3:25% ) IMGSEL=1 ( 0:captured image 1:decoded image ) ********* END ********** THIR-XXXX
(Description of status IMG)
IMODE= The coordination of image where to start capturing. 0: Full size 1: Specified
PX=_, PY=_ Specification of the starting coordinate for image transmission
WX=_, WY= The coordination of image where to end capturing (horizontal and vertical)
CAPX=_ Prefixed cropping (Horizontal) 0: 100% 1: 75% 2: 50% 3: 25%
CAPY=_ Prefixed cropping (Vertical) 0: 100% 1: 75% 2: 50% 3: 25%
Save Settings
(Write into Flash ROM)
Page 85
84
Image Area Definition
The origin point is located on the upper left of the image when the image transmitting area is specified.
Origin Point (0,0)
(PX,PY)
WX
WY
Page 86
85
Status “LF”
Transmit status LF
(Output example) ******** STATUS ******** THIR-XXXX LFMODE=0 (0:OFF 1:ON) LFMOVELIM=2 (0:1000ms 1:2000ms 2:3000ms 3:4000ms 4:5000ms 5:6000ms 6:8000ms 7:10000ms) LFDECLIM=2(x500mS 1-20 ) LFPOINTER=1 (0:OFF 1:ON) VSENS=2 (0-4) LFVERIFY=1 (0:OFF 1:ON) LFVWAIT=6(x500mS 1-20 ) LFINTVL=0 (0-5000ms) ********* END ********** THIR-XXXX
(Description of status LF) LFMODE=_ Choosing Auto Detection mode 0: OFF 1: ON
LFMOVELIM=_ Detection ignored time (ms) 0: 1000 1: 2000 2: 3000 3: 4000 4: 5000 5: 6000 6: 8000 7: 10000
LFDECLIM= Time for LFMOVELIM (within this time the scanner ignores the detection of an object) (s) 1~20: 0.5(S)~10(S) [Step: 0.5(s)]
LFPOINTER= Aiming beam during auto detection mode 0: Off 1: Blink
VSENS=_ Sensitivity against change of image 0 (Highest) 4 (Lowest)
LFVERIFY= Don’t want to read same data? 0: No 1: Yes
LFVERIFYLIM=_ Time for LFVERIFY (within this time the scanner doesn’t read same data continuously) 1~20 : 0.5 (s)~10 (s) [Step: 0.5(s)]
LFINTVL= Interval of continuous reading after the auto detection mode (ms) 0~5000 ms
Save Settings
(Write into Flash ROM)
Page 87
86
6. Setting for HID Type Only
Setting of special function for HID type (Human Interface Device), describe at below.
Data Transmission Interval
Setting for data transmission interval time
(Note)
-Reactivate the scanner after reading “Save the Setting” barcode to reflect the setting of the data transmission interval time.
-Depending on the receiving device, data receiving failure may happen in short transmission interval.
-Depending on the data receiving interval of the computer, the setting of data transmission interval cannot be reflected in the scanner’s performance.
0ms 3ms
5ms 7ms
10ms 20ms
30ms
Save Settings
(Write into Flash ROM)
Page 88
87
Keyboard Selection
1) Select Japanese or English keyboard from the bar code below and save the setting.
2) Reactivate the scanner to reflect the setting.
Select Japanese Keyboard Select English Keyboard
Caps Lock Setting
Sets Caps lock convert.
Capslock OFF Capslock ON
Capslock AUTO
Output example) Output dataAaBbCc
Setting
Result
Scanner Setting
Keyboard
Status
Output
Caps Lock OFF
Caps Lock
OFF
AaBbCc
Caps Lock ON
aAbBcC
Caps Lock ON
Caps Lock
OFF
aAbBcC
Caps Lock ON
AaBbCc
Caps Lock
AUTO
Caps Lock
OFF
AaBbCc
Caps Lock ON
AaBbCc
Save Settings
(Write into Flash ROM)
Page 89
88
・Setting for Uppercase/Lowercase Conversion
Converted alphabets can be output if there are alphabets in the output data.
No conversion Uppercase conversion
Lowercase conversion Uppercase/lowercase conversion
Output example) Output dataAaBbCc
Setting
Result
Scanner Setting
Output
No Conversion
AaBbCc
Uppercase Conversion
AABBCC
Lowercase Conversion
aabbcc
Uppercase/Lowercase
Conversion
aAbBcC
Save of Setting
(Write Flash ROM)
Page 90
89
HID Status
Display the HID status information.
Transmit HID Status
(Output example) ******** STATUS ******** THIR-XXXX HIDDELAY=1 (0:0ms 1:10ms 2:20ms 3:30ms 4:3ms 5:5ms 6:7ms) HIDKEYTYPE=0 (0:JIS 1:ISO) HIDCAPS=0 (0:OFF 1:ON 2:AUTO) STRCONV=0 (0:OFF 1:UPPER 2:LOWER 3:EXCHANGE) ********* END ********** THIR-XXXX
(Description of Status HID) HIDDELAY= Data transmitting interval (ms) 0: 0 1: 10 2: 20 3: 30 4: 3 5: 5 6: 7
HIDKEYTPYE= Keyboard 0:JIS(Japanese) 1:ISO(English)
HIDCAPS= CapsLock 0: CapsLock OFF 1: CapsLock ON 2: CapsLock Auto
STRCONV= Character conversion 0: No character conversion 1: Convert all characters into lowercase 2: Convert all characters into uppercase 3: Convert uppercase into lowercase and lowercase into uppercase
Save Setting
(Write Flash ROM)
Page 91
90
7. USB Device Type
This function switches the type of USB device when connected to a Windows computer. Available interface types:
-USB Virtual COM (VCOM) Image Reader
-Human Interface Device (HID) Image Reader
[How to switch between device types]
-Settings for both of reader and computer is necessary.
1) How to switch VCOM type into HID type How to change reader setting
1. Read the bar code to start switching.
2. Read the bar code of HID image reader.
3. Read the “Save Settings” bar code.
How to change PC setting
1. Close the application which uses virtual COM.
2. Click “Safely Remove Hardware” and select ”Tohken Virtual COM Port for USB”.
3. Unplug the USB connector of the reader from PC and re-plug it again.
2) How to switch HID type into VCOM type How to change reader setting
1. Read the bar code to start switching.
2. Read the bar code of USB image reader.
3. Read the “Save Settings” bar code.
How to change PC setting
Unplug the USB connector of the reader from PC and plug it again.
Page 92
91
Initiate USB interface type switch
Enable Switching
Select interface type
VCOM Image Reader HID Image Reader
Save Settings
Save Settings
Page 93
92
Memorandum
Page 94
93
Memorandum
Page 95
94
Memorandum
Page 96