MTS Sensors Temposonics R- V Brief Instructions

R-Series V
Brief Instructions
Temposonics
®
Magnetostrictive Linear Position Sensors
GENERATION
V
THE NEW
Temposonics® R-Series V
Brief Instructions
I 2 I
Table of contents
1. Introduction .......................................................................................................................................................................... 3
2. Safety instructions ............................................................................................................................................................... 4
2.1 Intended use ..................................................................................................................................................................4
2.2 Foreseeable misuse........................................................................................................................................................4
2.3 Installation, commissioning and operation ....................................................................................................................5
2.4 Safety instructions for use in explosion-hazardous areas .............................................................................................. 5
2.5 Warranty ........................................................................................................................................................................5
2.6 Return ............................................................................................................................................................................ 5
2.7 Maintenance & removal .................................................................................................................................................5
3. Identification ........................................................................................................................................................................ 6
3.1 Temposonics
®
RP5 ........................................................................................................................................................6
3.2 Temposonics
®
RH5 ........................................................................................................................................................ 6
4. Installation & mounting ....................................................................................................................................................... 7
4.1 Magnet installation ......................................................................................................................................................... 7
4.2 Mounting dimensions ....................................................................................................................................................8
4.3 Multi-position measurement distances .......................................................................................................................... 9
5. Electrical connections & LED status .................................................................................................................................10
5.1 Profinet ........................................................................................................................................................................ 10
5.2 EtherNet / IP
...............................................................................................................................................................12
Temposonics® R-Series V
Brief Instructions
I 3 I
1. Introduction
1.1 Purpose and use of this manual
Before starting the operation of Temposonics
®
position sensors, read this documentation thoroughly and follow the safety information. Keep this manual for future reference!
The content of this technical documentation is intended to provide information on mounting, installation and commis­sioning by qualified automation personnel
1
or instructed service technicians who are familiar with the project planning and dealing with Temposonics
®
position sensors.
1.2 Used symbols and warnings
Warnings are intended for your personal safety and for avoid­ance of damage to the described product or connected devic­es. In this documentation, safety information and warnings to avoid danger that might affect the life and health of operating or service personnel or cause material damage are highlight­ed by the pictogram, defined below.
Symbol Meaning
NOTICE
This symbol is used to point to situations that may lead to material damage, but not to personal injury.
1/ The term “qualified technical personnel” characterizes
persons who
• are familiar with the safety concepts of automation technology applicable to the particular project and
• are competent in the field of electromagnetic compatibility (EMC) or
• have received adequate training for commissioning and service operations or
• and are familiar with the operation of the device and know the information required for correct operation provided in the product documentation
Temposonics® R-Series V
Brief Instructions
I 4 I
2.1 Intended use
This product may be used only for the applications defined under item 1 and only in conjunction with the third-party devices and components recommended or approved by MTS Sensors. As a prerequisite of proper and safe operation, the product requires correct transport, storage, mounting and commissioning and must be operated with utmost care.
1. The sensor systems of all Temposonics
®
series are intended exclu sively for measurement tasks encountered in industrial, commercial and laboratory applications. The sensors are considered as system accessories and must be connected to suitable evaluation electron ics, e.g. a PLC, IPC, indicator or other electronic control unit.
2.2 Foreseeable misuse
Manuals, Software & 3D models available at: www.mtssensors.com
2. Safety instructions
Do not alter the sensor. The sensor might be damaged.
Do not step on the sensor. The sensor might be damaged.
Foreseeable misuse Consequence
Wrong sensor connection
The sensor will not work
properly or can be damaged Operate the sensor out of the operating temperature range
No signal output
The sensor can be damaged
Power supply is out of the defi ned range
Signal output is wrong /
no signal output /
the sensor can be damaged Position measurement is infl uenced by an external magnetic fi eld
Signal output is wrong
Cables are damaged
Short circuit – the sensor can
be destroyed / sensor does not
respond Spacers are missing /
are installed in the wrong order
Error in position measurement
Wrong connection of ground / shield
Signal output is disturbed
The electronics can be damaged Use of a magnet that is not
certifi ed by MTS Sensors
Error in position measurement
Temposonics® R-Series V
Brief Instructions
I 5 I
2.3 Installation, commissioning and operation
The position sensors must be used only in technically safe conditions. To maintain this condition and to ensure safe operation, installation, connection and service, work may be performed only by qualified technical personnel. If danger of injury to persons or of damage to operating equipment is caused by sensor failure or malfunction, additional safety measures such as plausibility checks, limit switches, EMERGENCY STOP systems, protective devices etc. are required. In the event of trouble, shut down the sensor and protect it against accidental operation.
Safety instructions for commissioning
To maintain the sensor operability, it is mandatory to follow the instructions given below.
1. Protect the sensor against mechanical damage during installation and operation.
2. Do not open or dismantle the sensor.
3. Connect the sensor very carefully and pay attention to the polarity of connections and power supply.
4. Use only approved power supplies.
5. Ensure the sensor is operating within the defined limits for supply voltage, environmental conditions, etc.
6. Check the function of the sensor regularly and provide documentation of the checks.
7. Before system switch-on, ensure that nobody’s safety is jeopardized by starting machines.
2.4 Safety instructions for use in explosion-hazardous areas
The sensors are not suitable for operation in explosion­hazardous areas.
2.5 Warranty
MTS Sensors grants a warranty
2
period for the Temposonics® position sensors and supplied accessories relating to material defects and faults that occur despite correct use in accordance with the intended application. The MTS Sensors obligation is limited to repair or replacement of any defective part of the unit. No warranty can be taken for defects that are due to improper use or above average stress of the product, as well as for wear parts. Under no circumstances will MTS Sensors accept liability in the event of offense against the warranty rules, no matter if these have been assured or expected, even in case of fault or negligence of the company. MTS Sensors explicitly excludes any further warranties. Neither the company’s representatives, agents, dealers nor employees are authorized to increase or change the scope of warranty.
2.6 Return
For diagnostic purposes, the sensor can be returned to MTS Sensors or a repair facility explicitly authorized by MTS Sensors. Any shipment cost will be borne by the sender
2
. For a corresponding form, see detailed operation manual (available at: www.mtssensors.com).
2.7 Maintenance & removal
Further information about maintenance and removal is provided in the sensor specific operation manuals.
2/ See also applicable MTS Sensors sales and supply
conditions, e.g. under www.mtssensors.com
Loading...
+ 11 hidden pages