MTM MP25, M35, M25, MP50, M50 Original Instruction Manual

...
AIR HEATER UNIT
TYPES M / MP
Original instruction manual
v. 08/2015
EC DECLARATION OF CONFORMITY
MTM Dariusz Seferyński
I hereby declare that the oil heating unit, for the heating of industrial premises not covered by a central heating system:
model no. M / MP, manufacture no. ................., construction year 20....,
according to its design and structure, fulfils the basic requirements concerning safety and health of the EU Machinery Directive, 2006/42/EC, and is manufactured according to directives:
- no. 2006/42/EC - Machinery Directive
- no. 2006/95/EC - Low Voltage Directive
- no. 2004/108/EC - Electromagnetic Compatibility
- no. 89/106/EC - Construction Product Directive as well as in accordance with the following norms
EN 1:1998+A1:2007 - Flued oil stoves with vaporising burners EN 303-5:1999 - Heating boilers. Heating boilers with forced draught burners. Heating boilers for solid fuels, hand
and automatically fired, nominal heat output of up to 300 kW. Terminology, requirements, testing and marking
EN 953:1997+A1:2009 - Safety of machinery. Guards. General requirements for the design and construction of
fixed and movable guards
EN 60204-1:2006+A1:2009+AC:2010 - Safety of machinery. Electrical equipment of machines. General
requirements
EN ISO 12100:2010 - Safety of machinery. General principles for design. Risk assessment and risk reduction EN ISO 13732-1:2008 - Ergonomics of the thermal environment. Methods for the assessment of human
responses to contact with surfaces. Hot surfaces.
EN ISO 13857:2008 - Safety of machinery. Safety distances to prevent hazard zones being reached by upper and
lower limbs
EN ISO 14159:2008 - Safety of machinery. Hygiene requirements for the design of machinery EN 60335-1:2002+A14:2010 - Household and similar electrical appliances. Safety. General requirements EN 55014-1:2006+A1:2009 - Electromagnetic compatibility. Requirements for household appliances, electric tools
and similar apparatus. Emission
EN 55014-2:1997+A2:2008 - Electromagnetic compatibility. Requirements for household appliances, electric tools
and similar apparatus. Immunity. Product family standard
EN 61000-6-1:2007 - Electromagnetic compatibility (EMC). Part 6-1: Generic standards. Immunity for residential,
commercial and light-industrial environments
EN 61000-6-3:2007 - Electromagnetic compatibility (EMC). Part 6-3: Generic standards. Emission standard for
residential, commercial and light-industrial environments.
Manufacturer representative authorised for the drawing up of machine technical documentation:
MTM Dariusz Seferyński
Heating, Ventilation, Air conditioning 04-239 Warszawa, Młodnicka 52 c Poland Contact person: Dariusz Seferyński
This declaration applies exclusively to the machine in the condition, in which it was introduced into trade circulation, and does not cover components added by the end user or any later actions they may have undertaken. In case unauthorised changes are made to the machine, the declaration becomes void.
Warsaw, on ............... 20.......... (full name and signature of the person authorised to make the declaration)
The present instruction manual is an integral part of the device, and should always accompany it. Before start-up of the device, please read the Original Instruction Manual carefully, taking time to ensure full understanding: The manufacturer and retailer are not liable for the loss of health of persons or animals caused by:
- usage of the equipment contrary to its foreseen use,
- usage of the equipment not in line with the original instruction manual,
- usage of the equipment contrary to fire and occupational safety provisions in force.
1. General rules
1.1. Foreseen use
Type M and MP air heaters are foreseen for the heating and ventilation of rooms in which people remain or work. Type M heaters are equipped with axial ventilators, while type MP heaters are equipped with radial ventilators.
1.2. Hazards stemming from improper heater use The hot air chamber is equipped with safety devices that have been checked and tested.
Improper use of the device can be hazardous to the persons making use of it, and possibly cause damage to components connected to the same electric circuit. Persons installing, using or servicing the heater should proceed in accordance with this Original Instruction Manual.
Safety indications
WARNING! This is an indication of a potential hazard. Seeing this symbol, one should pay particular attention to information found below it. Failure to observe remarks indicated with this symbol may lead to damage to the heater or even to personal injury.
IMPORTANT! This is an indication of the requirement to read the information found after it very carefully, as this will contribute to safe use of the device.
1.3. General indications Air heaters with heat exchangers may be used in rooms, in which people remain. WARNING!
Never install the heater in any room, in which there is any risk of explosions. WARNING! Exhaust fumes may cause a fire. Always maintain a safe distance to combustible materials.
1.4. Rules of safe operation
The heater with a heat exchanger burns light fuel oil or diesel oil in a closed combustion chamber. The exhaust fumes are led to the outside through the chimney. Warm air is blown out by the ventilator. The ventilator is covered with a protective mesh on the air intake.
WARNING! Never use the heater without the ventilator safety mesh, as this may cause damage to persons and objects. IMPORTANT! The air intake and output openings must be uncovered at all times. WARNING! If the exhaust gases are directed straight towards any combustible material, this may cause a fire. WARNING! Before commencing any repairs or cleaning of the heater, remove the electric plug from the grid socket. Use the heater only as it is supposed to be used, meaning, solely and exclusively for heating and ventilation.
1.5. Recommendations for the user
The heater should be operated by a person who, before using the device, had thoroughly acquainted themselves with this Original Instruction Manual.