MTM 8-30 Original Manual

UNIVERSAL OIL HEATER
TYP MTM 8-30 kW
V. 08/2015
ORIGINAL MANUAL
MTM DARIUSZ SEFERYŃSKI
HEATING, VENTILATION, AIR CONDITIONING 04-239 Warsaw, ul. MŁODNICKA 52 C
I hereby declare that the oil air heater intended for heating industrial rooms
without central heating systems:
model MTM 8-30, serial no. ......................................... manufactured in the year 20……..
Rated power of 8-30 kW due to its design and structure, meets the basic safety and health requirements set forth in
the Directive 2006/42/EC on machinery and has been manufactured according to the directives as follows:
Directive 2006/42/EC - on machinery (MD)
Directive 2006/95/EC - on electrical equipment designed for use within certain voltage limits (LVD)
Directive 2004/108/EC - on electromagnetic compatibility (EMCD)
Directive 89/106/EEC - on construction products (CPD)
and the following norms:
EN 1:1998+A1:2007 Fuel oil stoves with vaporising burners and chimney connection
EN 303-5:1999 Heating boilers - Part 5: Solid fuel heating boilers with manual and automatic fuel charge
with rated power of max. 300 KW - Definitions, requirements, testing and marking and labelling.
EN 953:1997+A1:2009 Safety of machinery - Guards - General requirements for the design and construction of fixed and movable guards
EN 60204-1:2006+A1:2009+AC:2010 Safety of machinery - Electrical equipment of machines - Part 1: General requirements
EN ISO 12100:2010 Safety of machinery - General principles for design - Risk assessment and risk reduction
EN ISO 13732-1:2008 Ergonomics of the thermal environment - Methods for the assessment of human
responses to contact with surfaces - Part 1: Hot surfaces
EN ISO 13857:2008 Safety of machinery - Safety distances to prevent hazard zones being reached by upper and lower limbs
EN ISO 14159:2008 Safety of machinery - Hygiene requirements for the design of machinery
EN 60335-1:2002+A14:2010 Household and similar electrical appliances - Safety - Part 1: General
requirements
EN 55014-1:2006+A1:2009 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
EN 55014-2:1997+A2:2008 Electromagnetic compatibility (EMC) - Requirements for household appliances, electric tools and similar apparatus - Immunity - Product family standard
EN 61000-6-1:2007 Electronic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments
EN 61000-6-3:2007 Electronic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments
The authorisation to compile the machine technical documentation has been given to the representative of the producer:
MTM DARIUSZ SEFERYŃSKI
HEATING, VENTILATION, AIR CONDITIONING 04-239 Warsaw, ul. MŁODNICKA 52 C
Contact person: Dariusz Seferyński
This declaration pertains only to the machine in condition in which it was launched on the market and does not cover component parts added by the end user or later actions performed by them. This declaration expires if any changes are made to the device that have not been consulted with us.
Warsaw, on ……………………..
20.....
(full name and signature of the person authorised to make the declaration)
1. Intended application
The universal oil heater type MTM 8-30 is designed to heat up industrial rooms not covered with central heating systems (workshops, car repair shops, industrial shops, warehouses, storage buildings, basements, garages, etc.). The furnace can operate using most oils, e.g. engine, transmission, hydraulic, diesel oil, HBO I, II and III type oil, with viscosity not exceeding SAE 80.
DO NOT USE TRANSFORMER OIL
AS IT MIGHT CONTAIN SUBSTANCES HARMFUL FOR STOVE OPERATION
TECHNICAL DATA
Maximal thermal capacity*
KW
30
Minimal thermal capacity *
KW 8Maximal fuel consumption
l/h
3.0
Minimal fuel consumption
l/h
0.8
Heated air flow
m3/h
1460
Power supply
V/Hz
230/50
Maximal power consumption
W
100
Exhaust fumes outlet diameter
mm
130
Device width
cm
92
Device height
cm
135
Device length
cm
54
Device weight
kg
50
*Calorific effect specified for fuel with the following parameters:
calorific value = 42.6 MJ/kg.
3
In case of higher parameters, the calorific effect can be increased even up to 33 kW.
TEMPLATE OF THE RATING PLATE PLACED
ON THE REAR ENCLOSURE OF THE DEVICE
2. Storage environmental conditions
The universal oil heater type MTM 8-30 must be stored in the following conditions: temperature -20..85°C relative humidity 5..85% pressure 800..1200 hPa no dusting environment free from chemical contamination.
3. Use environmental conditions
The universal oil heater type MTM 8-30 must be used in the following conditions: temperature 0..30°C relative humidity 5..85% pressure 800..1200 hPa IP protection level against environmental impact IP65 good ventilation of the heated room.
4. Controller characteristics
three-stage power adjustment for the stove 8-19-30 kW,
preserving settings after blackout.
5. Safety aspects
The MTM 8-30 universal oil heater is powered by the alternating current network of 230V/50Hz. It is equipped with three sensors, ensuring safe and economic operation of the device.
1. The bimetallic sensor, placed in the furnace chamber, reacts with short circuit of the contacts in the
thermostat when the temperature exceeds 40°C and with contact opening when the temperature drops below 35°C.
2. The bimetallic sensor is located near the downcast ventilator, with threshold temperature
of 100°C, opens the contacts when the said temperature is exceeded and causes switching of the stove in to the
emergency mode, cutting off inflow of fuel, thus securing the fan against overheating or melting of its elements.
3. Microswitch - weight sensor located under the combustion chamber. Filling the pan causes immediate switching into the emergency mode, cutting off the fuel inflow, securing against leakage of the excess non-evaporated fuel outside the combustion chamber, eliminating the possibility of its ignition outside the device.
The connection of the stove controlling panel to other system components (sensors, pump, fan) is factory-made. During normal use, due to operation safety, under no circumstances should there be any interference in the covered and sealed part of the stove controller or duct integrity. Any action by an unauthorised person may result in electrocution (230V AC, 50Hz) and burning.
6. Structure of STOVE MTM 8-30
Fig. 1. MTM 8-30 heater structure
Fig. 2. MTM 8-30 heater block diagram.
BIMETALLIC OVERHEAT SENSOR (STB) RESET
CONTROLLER
FUEL TANK
FUEL FEEDING PUMP BURNER
CONTROL
THERMOSTAT
FAN
HOUSING UPPER
HOUSING OF THE COMBUSTION CHAMBER
EXHAUST FUMES OUTLET
COMBUSTION CHAMBER
TROLLEY OVERFLOW SENSOR
CONTROL THERMOSTAT FAN
CONTROLLER
FUEL PUMP MOTOR
OVERFLOW PAN
TRANSFOR
MER
FUSE