MTL Instruments ZoneMaster Specifications

• Enhanced redundancy built into each
module
• Easy to read status indication
• Thermal and short circuit fusing
• Low let-through performance with
high current impulses
• 100k AIC short circuit current rating
• Replaceable bolt-in modules
• Large block MOV technology
• UL 1449 3rd Edition
• 15 year product warranty
technical datasheet
ZoneMaster Series
Ideally suited to protect small to medium service entrance panels from induced surges and transients
The ZoneMaster Series of surge protection devices combines unparalleled
power handling capability, application versatility, proven circuitry along with simple installation, features which make these units the ultimate mains power protection solution. With configurations suitable for all International supply voltages, ZoneMaster is truly a versatile and flexible protection range.
ZoneMaster devices are modular in construction. Individual modules are bolted
to a large surge return plate to minimise transient impedance. These colour coded, replaceable modules, with a UL 94-5V rated plastic casing are supplied mounted within a durable IP66 rated enclosure. ZoneMaster units are easy to install via simple wall mounting, although flush mounting is also an option.
Large block, 3 terminal Metal Oxide Varistor (MOV) protection technology
is utilised within the ZoneMaster range. The dual protection circuits of ZoneMaster 150 devices provide full redundancy ensuring the site is never unprotected. All ZoneMaster units also include thermal and short circuit fusing for additional safety.
Status indication is supplied as standard, normally open/ normally closed
contacts change state to indicate a fault. An optional remote monitoring unit is also available providing audio and visual indication of protector status, along with features such as a test switch for checking the monitoring circuitr y and an audio alarm silence switch.
The optional mains power filter has a noise attenuation of 75dB at 100KHz- 100MHz and will attenuate 6kV transients down to just 200V. This mains power filter is UL 1283 Listed and all ZoneMaster devices have UL 1449 Listing for added peace of mind.
901-133 Rev M 110511
www.mtl-inst.com enquiry@mtl-inst.com
SPECIFICATION
All figures typical at 77°F (25°C) unless otherwise stated
Maximum continuous operating voltage
120V — 140Vac 240V — 280Vac 277V — 320Vac
Lines protected
ZoneMaster 170 L-N 170kA, L-L 170kA, N-G 170kA ZoneMaster 200 L-N 200kA, L-L 200kA, N-G 200kA Duty cycle performance (8/20µs) 100,000A >4 impulses 10,000A >8,000 impulses 170A infinite
Impulse current for class I (I
50kA (10/350µs)
Long duration current pulse (10/1,000µs) capability
3,600A (tested)
Ambient temperature limits
-40°F to +185°F (working)
-40°C to +85°C (working)
Humidity
95% RH (non-condensing)
Enclosure
NEMA 1, 2, 3, 3S, 4, 4X, 12 & 13 (IP66)
Terminals
2 AWG (32mm2)
Mounting
Surface mount by 0.31” (8mm) diameter holes
Indication
Continuous visual status monitoring Green LED Lit = Full protection Red LED Lit = Reduced (Standby) No protection Green LED out = No power to protector
Remote contacts
NO/NC
Weight
Approx. 7 lbs (3.2 kg)
Dimensions
Enclosure — see figure 1
EMC compliance
BS EN 60950: 1992 BS EN 61000-6-2: 1999
imp
)
OR
Model Maximum
surge
current
Imax (kA)
ZM11200 170 120/240 split 600 350 446 Split phase 3 wire
ZM11201 170 120/208 600 350 446 Three phase 4 wire WYE
ZM11202 170 120/240 600/1000 350 446 Three phase 4 wire Delta
ZM11203 170 240 1000 760 886 Three phase 3 wire Delta
ZM11204 170 277/480 1000 760 886 Three phase 4 wire WY
ZM11206 170 480 1800 1480 1680 Three phase 3 wire Delta
ZM11207 170 220/380 1000 760 886 Three phase 4 wire WYE
ZM11208 170 240/415 1000 760 886 Three phase 4 wire WYE
ZM11300 200 120/240 split 600 350 446 Split phase 3 wire
ZM11301 200 120/208 600 350 446 Three phase 4 wire WYE
ZM11302 200 120/240 600/1000 350 446 Three phase 4 wire Delta
ZM11303 200 240 1000 760 886 Three phase 3 wire Delta
ZM11304 200 277/480 1000 760 886 Three phase 4 wire WYE
ZM11306 200 480 1800 1480 1680 Three phase 3 wire Delta
ZM11307 200 220/380 1000 760 886 Three phase 4 wire WYE
ZM11308 200 240/415 1000 760 886 Three phase 4 wire WYE
*Tested as per ANSI/IEEE C62.45; IEC 61643-1 Uoc = 6kV
Working
voltage
(V)
UL
VPR
3rd Edition*
Limiting voltage Phase types
@ 3kA
(V)
@10kA (In)
(V)
OPTIONAL POWER FILTER
Limiting voltage 200V (@ 3kA 8/20µs) Maximum attenuation (typical)
-75dB (100kHz to 100MHz)
TO ORDER SPECIFY -
Model number as per specification table Add suffix X for EMI/RFI filter
Add suffix F for flush mount options
OPTIONAL REMOTE MONITORING UNIT
ZM11101 — Battery operated
EUROPE (EM EA): +44 (0 )1582 723633 THE AMER ICAS: +1 800 835 7075 ASIA-PACIF IC: +65 6 645 9 888
enquiry@mtl-inst.com csinfo@mtl-inst.com sales.mtlsing@cooperindustries.com 901-133 Rev M 110511
Figure 1 Dimensions
APPROVALS
Country Standard/Authority Approved for Product
United States Canada
UL 1449 Listed AC power product ZoneMaster
The given data is only in tended as a product des cription and should not b e regarded as a legal warranty o f properties or guarantee. I n the interest of fur ther technical developme nts, we reserve the right to make design chan ges.
Loading...