MTL Instruments MTL2210B Data sheet

EUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283 AMERICAS Tel: +1 603 926 0090 Fax: +1 603 926 1899 ASIA PACIFIC Tel: +65 487 7887 Fax: +65 487 7997 E-mail: enquiry@mtl-inst.com Web site: www.mtl-inst.com
Oct 2004
To earth or MTL4220
MTL2210B SWITCH OPERATED RELAY
1-channel
Link
Motor control circuits
Load, alarm or shutdown circuits
Link for latching
Stop (unlatch)
Start (latch )
MTL4220
Link
All contacts shown in alarm condition (relay de-energised)
L
N
The MTL2210B enables two 500VA safe-area loads to be controlled in separate circuits simultaneously by one light-duty on/off switch in a hazardous area. Alternatively, it can be arranged to latch for pushbutton stop/start control of an electric motor, the relay then being energised by brief closure of one switch contact and de-energised by the brief opening of another. The stop switch overrides the start switch, even if the start circuit is closed, making sure that the motor can be turned off under all conditions. In this application, the second pair of changeover output contacts enables the status of the motor to be fed to a computer or data logger.
SPECIFICATION
See also ‘Common specification’
Number of channels
One, fully floating
Location of switch(es)
Zone 0, IIC, T6 hazardous area Div 1, Group A, hazardous location
Voltage applied to switch(es)
5.6V dc from 1.5k
Input/output characteristics
Relay energised if <200between tmnls 1 & 2 and 3 & 4 Relay de-energised if >500between tmnls 1 & 2* or 3 & 4 Hysteresis, nominal 100
*Non-latching mode
Latching facility
(Enabled by linking terminals 5 & 6) Relay then latches ON when energised (shorts tmnls 1 & 2) Relay de-energised if unlatch circuit broken (latching)
Power supply failure protection
Relay de-energised if supply fails
Broken line protection
Relay de-energised if either line broken (non-latching) Relay de-energised if unlatch circuit broken (latching)
‘Fail-safe’ earth fault protection
(Enabled by connecting terminal 8 to earth) Relay de-energised if <1kto earth, total for all 3 lines Relay not de-energised if >7.5kto earth, total for all 3 lines
‘No-fail’ earth fault protection
(Enabled by connecting terminal 8 to MTL4220) Fault on any line proclaimed: unit continues working
Response time
50ms, nominal
Contacts
2-pole changeover
Contact rating
250V:5A:500VA (ac) (resistive loads, reactive loads must be suppressed) 250V:5A:250W (dc) (resistive loads, reactive loads must be suppressed)
Contact life expectancy
2 x 105operations at maximum load
LED indicator
ON when relay energised
Consumption
0.9 to 1.4W (ac versions) 60mA (24V dc version)
Load, alarm or shutdown circuits
Motor stop/start control
Fail-safe protection
No-fail protection
L
N
L
N
Ambient temperature limits
–20 to +55°C (all versions, close packed)
–20 to +60°C (all versions, at least 5mm apart)
–40 to +80°C (all versions, storage)
Safety description
7V, 300, 22mA
FM max entity parameters
Voc= 8.3V, Isc= 26mA, Ca= 7µF, La= 47mH