MTE RL Reactors Product Specification

RL
Reactors
Best-in class power quality units
for absorbing power line
disturbances
mtecorp.com
Best-in-class line/load reactors
Most robust, highest continuous service factor
Low watts loss
Performance and durability that is unmatched by the competition
Peace of mind included.
Our RL Line/Load Reactors are best-in class power quality units with a long history of proven performance. Rugged and robust, they are unequalled in absorbing power line disturbances that can damage or shut down variable frequency drives (VFDs) and other sensitive equipment. They work on both the line side and load side to give you an easy solution that reduces nuisance tripping, reduces harmonic distortion and minimizes long lead effects.
Improved power quality, enhanced productivity and complete peace of mind are easy with RL Line/ Load Reactors.
Power quality. Solved.
Get best-in-class performance with our RL Line/Load Reactors.
Our RL Line/Load Reactors are a robust, best-in-class
filtering solution for virtually any 4 or 6-pulse rectifier
or power conversion unit. There is no need to de-rate these reactors. They are harmonic compensated and protected to assure optimum performance in the presence of harmonics, and can help you meet
IEEE-519 requirements. There are units available for a full line of currents (1A to 1,500A) and a full line of impedance options (1.5%, 3% and 5%).
RL
Reactors
SineWave Filters
Robust design and construction for unequalled
filtering of power line disturbances.
Highest continuous service factor virtually eliminates breakdowns in the field.
Reduces audible noise.
Multiple cabinet designs help meet NEMA 1/2 and 3R.
Performance Specifications:
Impedance Levels 1.5%, 3% and 5%
Continuous Service Factor Reactors rated 1 to 750 Amps - 150%
of rating Reactors rated above 750 Amps - 125% of rating
Overload Rating 200% of rated for 30 minutes
300% of rated for 1 minute
Voltage Range 208V - 690V
Current Range 1A - 1,500A
Temperature Rise 135°C
Ambient Temperature -40 to 50°C
Altitude Maximum 1,000 meters
Fundamental Frequency 50/60 Hz
Inductance Curve 100% at 100% Current
100% at 150% Current 50% at 350% Current
Matrix® AP
Line Reactors
Ln
Line Side
Utility Power Motor
MTE
Input
Reactor
MTE
Output
Reactor
Harmonic Filters
Waveform without reactor
VFD
dV/dt Filters
Load Reactors
Ld
Load Side
Motor Protection
Waveform with reactor
Product specifications subject to change.
Power quality. Solved.
MTE Corporation
N83 W13330 Leon Road • Menomonee Falls, WI 53051
(800) 455-4MTE • (262) 253-8200 • mtecorp.com
Form RL-PSP-E 3/14
Supersedes RL-PSP-E June 2012
© 2014 MTE Corporation Printed in U.S.A.
ENCLOSURES
RL Reactors
FIGURE 1
FIGURE 2
FIGURE 3
W
D
H
W
H
H
W
D
NOTE: HOODS ONLY ON NE MA 3R ENCLOSURES
D
FIGURE 4
FIGURE 5
NOTE: HOODS ONLY ON NE MA 3R ENCLOSURES
W
D
H
W
D
H
Loading...
+ 4 hidden pages