MTE Matrix AP Catalog

Matrix® AP
Product Selector
Adapts to varying power loads
Best performance in the industry
Harmonic Filters
The key to success: adapt.
Simply put, our Matrix® AP is the most advanced passive filter on the market today. Most traditional filters work fine at 100% power load, but severely underperform at lower loads. Matrix AP is different, because we know almost no one runs at full load all the time. Its patented Adaptive Passive Technology virtually eliminates harmonic distortion by adapting to varying power loads. It delivers better THID performance, increases energy efficiency and allows you to meet IEEE-519 requirements.
Extends the service life of electrical equipment
Generator compatible
Performance guarantee
Its unique design generates less heat, and is easy to install and maintain. Plus it is generator compatible. With Matrix AP Harmonic Filters, power quality, energy efficiency and reduced downtime are easy to achieve.
Improve power quality and reduce downtime with our patented Adaptive Passive Technology.
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
7.0
7.5
8.0
8.5
9.0
9.5
10.0
10.5
11.0
11.5
12.0
12.5
13.0
13.5
0 10 20 30 40 50 60 70 80 90 100
Matrix AP - Generator Compatible Competition A - Not Generator Compatible Competition B - Not Generator Compatible Competition C
The best-in-class Matrix® AP Harmonic Filters can be specified for use on the input of your VFD or other 6-pulse rectifier power supply to enable your system to meet the IEEE-519 requirements for harmonic distortion, regardless of power load.
Features our patented Adaptive Passive Technology for superior harmonic mitigation and better THID performance over a wider load range.
MTE performance guarantee provides peace of mind that the Matrix AP will meet or exceed performance expectations - every time.
Extends service life of electrical equipment, especially transformers and motors, due to the virtual elimination of CEMF and the skin effect.
Matrix® AP
Alleviates system downtime by preventing blown fuses
and tripped circuit breakers.
Industry leading THREE year warranty because the best products deserve the best warranty.
Performance Specifications
Service Load Condition Load: 6-pulse rectifier only
380V - 415V +/- 10%; 50 + 0.75Hz; 3-phase
Input Voltage
Maximum THID 8% @ 30% load; 5% @ full load
Maximum Ambient Temperature
Insertion Loss @ Full Load <4%
Efficiency 97% - 99%
Altitude Without Derating 3,300 feet above sea level
Relative Humidity 0% to 95% non-condensing
Current Rating 150% for 1 minute duration
Final product specifications subject to change at anytime.
480V +/- 10%; 60 + 0.75Hz; 3-phase 600V +/- 10%; 60 + 0.75Hz; 3-phase 690V +/- 10%; 50 + 0.75Hz; 3-phase
-40C to +50C open panel filters;
-40C to +40C – 45C enclosed filters;
-40C to +90C storage
Utility Power
Matrix® AP
Filters
MTE vs. Competition THID [%]
Percent THID [%]
Percentage of full load [%]
Matrix AP Harmonic Filters can help ensure that your system meets the IEEE-519 requirements for harmonic current.
VFD
How to properly size your filter
• Determine voltage and frequency requirements
• Reference motor nameplate to determine motor HP or KW and Full Load Amps
• Select filter based on Motor Full Load Amps Do not exceed filter's maximum
current rating (amps)
Harmonic Filters
Matrix AP Options
Contactor Option 002: Contactor for capacitor disconnect
Includes NO/NC auxiliary contacts
Wired to customer terminal block
Pre-wired within enclosed part numbers
Requires 120V 50/60Hz power source
Contactor Option 012: Contactor with control transformer (Only available for enclosed filters)
Option 002 including a 120 VAC control transformer
• Specify enclosure style Open (No enclosure) NEMA 1/2 (General Purpose Enclosure) NEMA 3R (Outdoor Enclosure)
• Determine derating requirements Reference Performance Specifications table on previous page
• Select desired options (if applicable)
Understanding the Matrix AP Part Number:
MAP X _ _ _ _ X _ _ _
Matrix AP
Enclosure Type
P = Open Magnetics (No Enclosure) G = General Purpose (NEMA 1/2) W = Weather (NEMA 3R)
Current Rating 0006 is 6 Amps 0083 is 83 Amps 2300 is 2300 Amps
Contactor Option 009: Contactor with adjustable pick up and drop out (Only available for enclosed filters)
Includes NO/NC auxiliary contacts
Includes a 120 VAC control transformer
Includes two current operated switches
Ability to adjust pick-up and crop current levels
Switches are preset at factory
Pick-up is 35% of filter output current rating Crop out is 20% of filter output current rating
Contactor Option 013: Filter bypass and capacitor contactor with control transformer (Only available for enclosed filters)
Includes NO/NC auxiliary contacts
Includes a 120 VAC control transformer
Pilot relay provided to limit inrush current
Jumper selection allows for single contact switching
(Normal bypass control with capacitor removal)
Option - 400: Standard NEMA 3R enclosure with optional rodent/serpent screen.
Provides intake exhaust air screens with (¼ x ¼) mesh
Not available on units 1600A (480V) and above
Voltage Frequency Code C 380 – 415 Volts 50 Hz D 480 Volts 60 Hz E 600 Volts 60 Hz F 690 Volts 50 Hz
Optional Contractor Options 002 - Contactor for capacitor disconnect 012 - Contactor with control transformer 009 - Contactor with adjustable pick up and drop out 013 - Filter bypass and capacitor contactor
with control transformer
MATRIX AP SELECTION TABLES
400V 50Hz
Motor
(Ref
Filter
Only)
Amps
Rating
KW Inches Millimeters Lbs Kgs Inches Millimeters 002 009 012 013
2.2 6
3.7 8
5.5 11
7.5 14
11 21
15 27
19 34
22 44
30 52
37 66
45 83
55 103
MTE Part
Number
MAPP0006C OPEN 8.6 x 8.0 x 5.4 218 x 203 x 137 20 9 3
MAPG0006C NEMA 1/2 24.0 x 12.5 x 17.9 610 x 318 x 455 66 30
MAPW0006C NEMA 3R 24.0 x 12.5 x 23.0 610 x 318 x 584 74 34
MAPP0008C OPEN 8.7 x 8.0 x 5.4 221 x 203 x 137 20 9 3
MAPG0008C NEMA 1/2 24.0 x 12.5 x 17.9 610 x 318 x 455 68 31
MAPW0008C NEMA 3R 24.0 x 12.5 x 23.0 610 x 318 x 584 75 34
MAPP0011C OPEN 9.9 x 9.0 x 4.8 251 x 229 x 122 28 13 3
MAPG0011C NEMA 1/2 24.0 x 12.5 x 17.9 610 x 318 x 455 75 34
MAPW0011C NEMA 3R 24.0 x 12.5 x 23.0 610 x 318 x 584 83 38
MAPP0014C OPEN 9.8 x 9.0 x 5.3 249 x 229 x 135 34 15 3
MAPG0014C NEMA 1/2 24.0 x 12.5 x 17.9 610 x 318 x 455 82 37
MAPW0014C NEMA 3R 24.0 x 12.5 x 23.0 610 x 318 x 584 90 41
MAPP0021C OPEN 11.7 x 10.5 x 6.7 297 x 267 x 170 50 23 3
MAPG0021C NEMA 1/2 24.0 x 12.5 x 17.9 610 x 318 x 455 98 44
MAPW0021C NEMA 3R 24.0 x 12.5 x 23.0 610 x 318 x 584 107 49
MAPP0027C OPEN 11.8 x 10.5 x 7.2 300 x 267 x 183 56 25 3
MAPG0027C NEMA 1/2 24.0 x 12.5 x 17.9 610 x 318 x 455 103 47
MAPW0027C NEMA 3R 24.0 x 12.5 x 23.0 610 x 318 x 584 111 50
MAPP0034C OPEN 11.7 x 10.5 x 7.7 297 x 267 x 196 68 31 3
MAPG0034C NEMA 1/2 24.0 x 12.5 x 17.9 610 x 318 x 455 115 52
MAPW0034C NEMA 3R 24.0 x 12.5 x 23.0 610 x 318 x 584 123 56
MAPP0044C OPEN 11.7 x 10.5 x 8.0 297 x 267 x 203 79 36 3
MAPG0044C NEMA 1/2 24.0 x 12.5 x 17.9 610 x 318 x 455 127 58
MAPW0044C NEMA 3R 24.0 x 12.5 x 23.0 610 x 318 x 584 134 61
MAPP0052C OPEN 14.0 x 12.0 x 9.0 356 x 305 x 229 100 45 4
MAPG0052C NEMA 1/2 33.9 x 17.8 x 20.9 861 x 452 x 531 174 79
MAPW0052C NEMA 3R 33.9 x 17.8 x 26.0 861 x 452 x 660 181 82
MAPP0066C OPEN 14.0 x 12.0 x 9.0 356 x 305 x 229 112 51 4
MAPG0066C NEMA 1/2 33.9 x 17.8 x 20.9 861 x 452 x 531 186 84
MAPW0066C NEMA 3R 33.9 x 17.8 x 26.0 861 x 452 x 660 194 88
MAPP0083C OPEN 14.0 x 12.0 x 10.9 356 x 305 x 277 139 63 4
MAPG0083C NEMA 1/2 33.9 x 17.8 x 20.9 861 x 452 x 531 212 96
MAPW0083C NEMA 3R 33.9 x 17.8 x 26.0 861 x 452 x 660 219 99
MAPP0103C OPEN 14.1 x 12.0 x 11.0 358 x 305 x 279 147 67 4
MAPG0103C NEMA 1/2 33.9 x 17.8 x 20.9 861 x 452 x 531 221 100
MAPW0103C NEMA 3R 33.9 x 17.8 x 26.0 861 x 452 x 660 228 103
Enclosure
Type
Filter Dimensions
(H x W x D)
Approx Weight
Capacitor/Capacitor Panel Assembly
Ref
Watts
Fig
Loss
114
6 Preinstalled in cabinet
149
6 Preinstalled in cabinet
180
6 Preinstalled in cabinet
206
6 Preinstalled in cabinet
235
6 Preinstalled in cabinet
266
6 Preinstalled in cabinet
298
6 Preinstalled in cabinet
356
6 Preinstalled in cabinet
388
7 Preinstalled in cabinet
459
7 Preinstalled in cabinet
565
7 Preinstalled in cabinet
660
7 Preinstalled in cabinet
Dimensions (H x W x D)
7.5 x 3.0 191 x 76 1 2 S
7.5 x 3.0 191 x 76 1 2 S
7.5 x 3.0 191 x 76 1 2 S
8.0 x 3.9 203 x 99 1 2 S
8.0 x 3.9 203 x 76 1 2 S
8.3 x 4.6 211 x 117 1 2 S
9.1 x 4.6 231 x 117 1 2 S
9.1 x 4.6 231 x 117 1 2 S
10.6 x 4.6 269 x 117 1 2 S
10.6 x 4.6 269 x 117 1 2 S
10.6 x 4.6 269 x 117 1 2 S
10.6 x 4.6 269 x 117 1 2 S
Qty
Req’d
Available Options
Ref Fig
* * * *
* * * *
* * * *
* * * *
* * * *
* * * *
* * * *
* * * *
* * * *
* * * *
* * * *
* * * *
* * * *
* * * *
* * * *
* * * *
* * * *
* * * *
* * * *
* * * *
* * * *
* * * *
* * * *
* * * *
* * *
* * *
* * *
* * *
* * *
* * *
* * *
* * *
* * *
* * *
* * *
* * *
Note: Weights and dimensions are for reference only. Please visit for detailed information. S = Standard stock offering * = Call for availability
Loading...
+ 8 hidden pages