![](/html/2b/2b55/2b55629495c22408ecea8f81d105b56c34c2e4a46d624f8afcb375b154cd5a49/bg1.png)
Electric, Spot-Sprayers Parts List
Model No.: SY15 15-Gallon, 1/4" x 25' FlexCoil Hose
Model No.: SY25 25-Gallon, 1/4" x 25' FlexCoil Hose
Ref.
No. Part No. Description Qty.
1 00022463 Spray Tip, Adjustable 1 19 00035628 Swivel Nut, Nylon 2
2 00005173 Strainer 1 20 00035627 Hose Barb, 3/8 Nylon 2
3 00017744 Adapter, 45° 1 21 see ref. 32 Hose, 3/8" x 14' —
4 00022462 Extension Wand, 15” 1 22 00035898 Tank, 15 Gallon, Polyethylene 1
5 00022449 Trigger Valve 1 00035884 Tank, 25 Gallon, Polyethylene 1
00018334 Wand Assembly (in clu de s 1 e ac h R ef.
1,Ref. 2, Ref 3. Ref. 4 and Ref. 5)
6 00035781 Hose Barb, 3/8 x 1/4 MPT 3 24 00018283 Wire Harness 1
7 01000215 Hose Clamp 8 25
8 00035816 Hose, 1/4" x 25', FlexCoil 1 26
9 00035631 Hose Barb, 3/8 x 3/8 MPT 2 27
10 00020851 Diaphragm Pump, Flojet 1 28 00035790 Conduit Strap, 1/2 1
11 00035678 Mach. Screw, # 10-24 x 3/4 Pan Hd. 4 29 00034947 Cap Screw, 5/16-18 x 1/2 Hex Hd. 1
12 00035599 Fitting, Adapter 1 30 00032078 Nipple, 3/8 MPT Close 1
13 00035601 Filter, 30 Mesh S.S. Screen 1 31 00032081 Tee, 3/8 FPT Brass 1
14 00035600 Hose Barb, 3/8 x 90° Swivel Elbow 1 32 01004805 Hose Kit, Includes 1 ea. (ref. 15 & 36) —
15 see ref. 32 Hose, 3/8"x 18' — 33 00031247 Valve, 90°, 1/4 FPT 1
16 00035626 Hose Barb, 3/8" x 90° Male Elbow 1 34 00032086 Fitting, Adapter, 1/4 MPT x 11/1 61 1
17 00035629 Washer, 11/16 Nylon 1 35 00032113 Elbow, 90°, 1/4 MPT x 3/8 Hose Barb 1
18 36 see ref. 32 Hose, 3/8" x 5" —
Ref.
No. Part No. Description Qty.
1 23 00022448 Tank Lid 1
Includes 2 ea. (ref. 21) —
![](/html/2b/2b55/2b55629495c22408ecea8f81d105b56c34c2e4a46d624f8afcb375b154cd5a49/bg2.png)
Electric, Spot-Sprayers
Operating Instructions
After Filling Tank:
1. Connect power cord red cable to positive and black cable to negative 12 volt DC power
source.
2. Turn pump power switch to "on".
3. Remove tank lid. Hold TriggerJet™ wand with nozzle pointing into fillwell. Squeeze wand
trigger allowing spray liquid to recirculate back into tank until air is purged from hoses.
Release pressure on trigger, remove wand from fillw ell and repla ce lid. You are now read
to spray.
4. Closing the 1/4" Bypass Valve stops tank agitation. Opening the valve all ows ta nk agitation
through the bypass hose. The wand output can be regulated by adjusting the Bypass
Valve.
(Note: We recommend the use of liquid products only.)
Adjusting Wand Tip:
1. The knurled body of the tip rotates a half turn to provide spray selection from a wide a ngle,
finely atomized cone spray to a straight stream spray.
Should Pump Fail to Run:
1. Check pump switch and power source connections.
2. Check 10 amp fuse in power cord.
3. Check internal pump parts for needed repairs.
Pump Runs - No Fluid:
1. Remove tank lid. Hold TiggerJet™ wand with nozzle pointing into fillwell. Squeeze wand
trigger and hold until pump primes. Allow spray liquid to recirculate into tank until air is
purged from hoses.
2. Check suction line inside tank and make certain it is not pinched or plugged.
3. Turn pump switch to "off" and check for clogged suction strainer at pump inlet. Remove
swivel hose fitting from strainer cap and remove strainer cap (one-quarter turn counterclockwise). Remove screen and clean.
We reserve the right to change designs, specifications and equipment at any time without notice and without incurring any obligations.
MTD Pro, P.O. Box 361131
Cleveland, OH 44136
Form No. 01003185 Rev. 99-4