MSTRONIC SOL10+8-24G1-24BNN+24BNN, SOL10+8-24G1-48ANN+24BNN, SOL10+8-24G1-48ANR+24BNN, SOL10+8-24G1-48BNN+24BNN, SOL10+8-24G1-56BDN+24BNN User Manual

...
Mstronic Co., Ltd.
SOL10+8-24G2 Series
Solar & PoE Battery Charger
User’s Manual SOL10+8-24G2-xxx Series
Features:
Dual Input, from solar panel and/or PoE (Solar First) to charge 24V
battery, and another triple outputs: two PoE outputs on front and rear, terminal block on rear
Built-in DC/DC converter, with various passive PoE output, 24V,
48V, 56V available. front PoE and rear PoE can be different.
Active PoE Output support 802.3at handshake (SOL10+8-24G1-
56BDN)
DIN Rail Mountable Support Gigabit Ethernet
Applications:
Remote Power Systems; Surveillance, Sensors Wireless Station; AP/Client/Repeaters UPS Systems; Lighting, Fences, Gates
Protection:
Battery Polarity Reverse Protection Battery Over Charge Protection Battery Over Discharge Protection Solar Panel Polarity Reverse Protection Solar Panel Over Charge Protection Output Short Circuit Protection Output Over Voltage Protection POE Output Short Circuit Protection Externally fused with a standard replaceable fuse
User’s Manual SOL10+8-24G2-xxx Series
Panel Description:
Item Name
Descriptions
1 POE :
PoE power input indicator: the LED lights when the PoE input jack (the lower jack) has 36V~57V input.
2 SOL :
Solar power input indicator: the LED lights when SOL terminal is connecting to a
solar panel and the solar panel input voltage is over 24V.
3 CHA :
Charging indicator: the LED lights when BAT terminal is connected to battery and
charging
4
LOA :
Loading indicator: the LED lights when the rear panel output terminal is connecting to a device and offering power. The LED always on when power ready.
5 REV :
Battery polarity reverse indicator: the LED lights when the battery polarities are reversed. (detail description see Sec. 5.1)
6 IN :
PoE Input Jack: the lower RJ45 jack, used for PoE input. Allowed input voltage 36~57V
7 OUT :
PoE Output Jack: the upper RJ45 jack, used for PoE output; Output voltage depends on what model you selected.
8 Fuse Fuse: for output over current protection, limiting the battery output current <= 10A.
9
SOL :
Solar Panel Terminal: used to connect the solar panel.
10 BAT :
Battery terminal: used to connect the battery. NOTE: ALWAYS CONNECT THIS TERMINAL FIRST. If solar panel or PoE source is installed before the battery, and if the polarities of battery are reversed, then the fuse will be burnt.)
11 LOA :
Load Terminal: for wire size up to 10AWG, the output voltage is the same as battery voltage.
12 POE2
2nd PoE Output Jack: used for PoE output; Output voltage depends on what model you selected, power only, no data. Can be different voltage with front PoE output.